• Title/Summary/Keyword: 입구조건

Search Result 374, Processing Time 0.029 seconds

Comparison of Gas Exchange Parameters between Same Volume of $N_2-O_2$ and Heliox Inhalation (동일한 상시 호흡량의 $N_2-O_2$ 및 Heliox 투여 시 가스교환지표의 비교)

  • Sohn, Jang-Won;Lim, Chae-Man;Koh, Youn-Suck;Lee, Jong-Deog;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.169-175
    • /
    • 1998
  • Background: Heliox is known to decrease $PaCO_2$ in patients with increased airway resistance by increasing minute ventilation and reducing work of breathing(WOB). Besides these effect, heliox is expected to decrease functional anatomic dead space owing to improvement of peak expiratory flow rate(PEFR) and enhancement of gas distribution. We investigated whether heliox can decrease $PaCO_2$ even at the same minute ventilation (VE) and WOB with $N_2-O_2$ to speculate the effect of the heliox on the anatomic dead space. Material and Method: The subjects were 8 mechanically ventilated patients with asthma or upper airway obstruction(M : F=5 : 3, $68{\pm}10$years) who were under neuromuscular paralysis. The study was consisted of three 15-minutes phases: basal $N_2-O_2$ heliox and washout Heliox was administered via the low pressure inlet of servo 900C, and respiratory parameters were measured by pulmonary monitor(CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). To obtain the same tidal volume(Vt) in heliox phase, the Vt on monitor was adjusted by the factor of relative flow rate of heliox to $N_2-O_2$. Dead space was calculated by Bohr equation. Results: 1) Vt, VE, peak inspiratory pressure(PIP) and peak inspiratory flow rate(PIFR) were not different between $N_2-O_2$ and heliox. 2) PEFR was higher on heliox($0.52{\pm}0.19$L/sec) than $N_2-O_2$($0.44{\pm}0.13$L/sec)(p=0.024). 3) $PaCO_2$(mmHg) were decreased with heliox($56.1{\pm}14.1$) compared to $N_2-O_2$($60.5{\pm}15.9$)(p=0.027). 4) Dead space ventilation(%) were decreased with heliox($73{\pm}9$ with $N_2-O_2$ and $71{\pm}10$ with heliox)(p=0.026). Conclusion: Heliox decreased $PaCO_2$ even at the same VE and WOB with $N_2-O_2$, and the effect was considered to be related with the reduction of anatomic dead space.

  • PDF

Comparison of Seawater Exchange Rate of Small Scale Inner Bays within Jinhae Bay (수치모델을 이용한 진해만 내 소규모 내만의 해수교환율 비교)

  • Kim, Nam Su;Kang, Hoon;Kwon, Min-Sun;Jang, Hyo-Sang;Kim, Jong Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.1
    • /
    • pp.74-85
    • /
    • 2016
  • For the assessment of seawater exchange rates in Danghangpo bay, Dangdong bay, Wonmun bay, Gohyunsung bay, and Masan bay, which are small-scale inner bays of Jinhae bay, an EFDC model was used to reproduce the seawater flow of the entire Jinhae bay, and Lagrange (particle tracking) and Euler (dye diffusion) model techniques were used to calculate the seawater exchange rates for each of the bays. The seawater exchange rate obtained using the particle tracking method was the highest, at 60.84%, in Danghangpo bay, and the lowest, at 30.50%, in Masan bay. The seawater exchange rate calculated based on the dye diffusion method was the highest, at 45.40%, in Danghangpo bay, and the lowest, at 34.65%, in Masan bay. The sweater exchange rate was found to be the highest in Danghangpo bay likely because of a high flow velocity owing to the narrow entrance of the bay; and in the case of particle tracking method, the morphological characteristics of the particles affected the results, since once the particles get out, it is difficult for them to get back in. Meanwhile, in the case of the Lagrange method, when the particles flow back in by the flood current after escaping the ebb current, they flow back in intact. However, when a dye flows back in after escaping the bay, it becomes diluted by the open sea water. Thus, the seawater exchange rate calculated based on the dye diffusion method turned out to be higher in general, and even if a comparison of the sweater exchange rates calculated through two methods was conducted under the same condition, the results were completely different. Thus, when assessing the seawater exchange rate, more reasonable results could be obtained by either combining the two methods or selecting a modeling technique after giving sufficiently consideration to the purpose of the study and the characteristics of the coastal area. Meanwhile, through a comparison of the degree of closure and seawater exchange rates calculated through Lagrange and Euler methods, it was found that the seawater exchange rate was higher for a higher degree of closure, regardless of the numerical model technique. Thus, it was deemed that the degree of closure would be inappropriate to be used as an index for the closeness of the bay, and some modifications as well as supplementary information would be necessary in this regard.

Feasibility Study on Double Path Capacitive Deionization Process for Advanced Wastewater Treatment (이단유로 축전식 탈염공정의 하수고도처리 적용가능성 평가)

  • Cha, Jaehwan;Shin, Kyung-Sook;Lee, Jung-Chul;Park, Seung-Kook;Park, Nam-Su;Song, Eui-Yeol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.295-302
    • /
    • 2014
  • This study demonstrates a double-path CDI as an alternative of advanced wastewater treatment process. While the CDI typically consists of many pairs of electrodes connected in parallel, the new double-path CDI is designed to have series flow path by dividing the module into two stages. The CFD model showed that the double-path had uniform flow distribution with higher velocity and less dead zone compared with the single-path. However, the double-path was predicted to have higher pressure drop(0.7 bar) compared the single-path (0.4 bar). From the unit cell test, the highest TDS removal efficiencies of single- and double-path were up to 88% and 91%, respectively. The rate of increase in pressure drop with an increase of flow rate was higher in double-path than single-path. At 70 mL/min of flow rate, the pressure drop of double-path was 1.67 bar, which was two times higher than single-path. When the electrode spacing was increased from 100 to $200{\mu}m$, the pressure drop of double-path decreased from 1.67 to 0.87 bar, while there was little difference in TDS removal. When proto type double-path CDI was operated using sewage water, TDS, $NH_4{^+}$-N, $NO_3{^-}$-N and $PO_4{^{3-}}$-P removal efficiencies were up to 78%, 50%, 93% and 50%, respectively.

A Study on the Establishment Process and Spatial Composition of TaiSho Park in Modern Busan (근대 부산에서 대정공원의 성립 과정과 공간 구성에 관한 연구)

  • Kang, Young-Jo
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.2
    • /
    • pp.92-102
    • /
    • 2013
  • This study aimed to reveal the establishment process and spatial composition of TaiSho park in modern Busan. The TaiSho park is an athletic park which combines a playground and a rest facilities. The arguments on construction of playground commenced for commemorating Kameyama, Busan director official, when he moved to Taiwan in 1910. First Proposers which construct to sport park were businessman in that time. However, construction of playground was progress as a commemoration business of accession of Taisho Tenno. Playground construction got into stride by the proposal of the Busan mayor Wakamatsu in 1917. When it looks into process of discussion about a site selection candidate, norms of playground site selection are the paly ground which appropriate with effective site area and distance between park and a section of a city, in other hand, those are accessibility and budget. As a result of several arguments and actual site investigation, it was decide to select a site which enters to elementary school, after the isolation hospital relocates. The cost of construction of the TaiSho park is prepared by donation of the Busan civil. The donation fund raising committee was constituted by local commerce and industry people, a company, government, municipal offices and area, and funds was raised systematically. As a result, total amount of construction cost was made from the donation of local civil. The TaiSho park is broadly into two sectors; exercise area and rest and pleasure space. Entrance was set up in three aspects of the park and the subcontract planted. The baseball field took the seat in the central part of the park, and also prepared two tennis courts. Japanese Sumo field was also prepared for the north side of the park. The significance of the TaiSho park in Korea Park history can be summarized in South Korea's first sports park and which was made from the donation of local civil. The remained subjects from this study are to clarify the disappearance process of TaiSho park and a reason why modern Busan people want to get playground.