• Title/Summary/Keyword: 입구온도

Search Result 347, Processing Time 0.187 seconds

Performance Analysis of Marine Solid Oxide Fuel Cell and Gas Turbine Hybrid Power System (under Conditions of Turbine Cooling and Constant Temperature in Cathode Inlet) (선박동력용 SOFC/GT 하이브리드시스템의 성능 평가 (터빈 냉각 및 공기극 입구온도 일정 조건을 중심으로))

  • Lim, Tae-Woo;Kil, Byung-Lea;Kim, Jong-Su;Oh, Sae-Gin;Park, Sang-Kyun;Kim, Mann-Eung;Kim, Myoung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1107-1115
    • /
    • 2009
  • The strengthened regulations for atmospheric emissions from ships like MARPOL Annex VI have caused a necessity of new, alternative power system in ships for the low pollutant emissions and the high energy efficiency. This paper attempts to investigate the configuration of SOFC/GT hybrid power system for marine applications like LNG tanker and to analyze the influence of design parameters on the system performance. The simulation results provide the basic data for the design and efficiency improvement of SOFC/GT hybrid system and indicate the guidelines for the safe system operation.

Effects of Prandtl Numbers on Heat Transfer of Backward-Facing Step Laminar Flow with a Pulsating Inlet (입구유동 가진이 있는 층류 후향계단 유동에서 열전달에 대한 프란틀수 효과해석)

  • Kim, Won-Hyun;Park, Tae-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.9
    • /
    • pp.923-930
    • /
    • 2012
  • The wall heat transfer of backward-facing step laminar flows with different Prandtl numbers and a pulsating inlet is investigated by unsteady simulations. The inlet is perturbed by the variation of frequency and amplitude. Temperature-dependent transport properties are adopted. Various characteristics of the wall heat transfer are explained by the variation of the thermal boundary layer. For Pr < 1, the wall heat transfer of temperature-dependent properties is decreased compared to that of constant properties, whereas it increases for Pr < 1. In addition, the wall heat transfer increases depending on the pulsating amplitude. However, the results of frequency variation for St < 0.2 show that the heat transfer is strongly enhanced at a specific frequency. In particular, the increase in the wall heat transfer is strongly related to the root mean square of the fluctuations of the reattachment length.

Experimental Evaluation of Hydrophilic Membrane Humidifier with Isolation of Heat Transfer Effect (친수성 막을 통한 수분 전달 특성 연구)

  • Tak, Hyun Woo;Kim, Kyoung Teck;Han, Jae Young;Im, Seok Yeon;Yu, Sang Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.9
    • /
    • pp.815-821
    • /
    • 2013
  • The efficiency and lifetime of a polymer electrolyte membrane fuel cell (PEMFC) system is critically affected by the humidity of the incoming gas, which should be maintained properly under normal operating conditions. Typically, the incoming gas of a fuel cell is humidified by an external humidifier, but few studies have reported on the device characteristics. In this study, a laboratory-scale planar membrane humidifier is designed to investigate the characteristics of water transport through a hydrophilic membrane. The planar membrane humidifier is immersed in a constant temperature bath to isolate the humidifier from the effect of temperature variations. The mass transfer capability of the hydrophilic membrane is first examined under isothermal conditions. Then, the mass transfer capability is investigated under various conditions. The results show that water transport in the hydrophilic membrane is significantly affected by the flow rate, operating temperature, operating pressure, and flow arrangement.

The Prediction of Air Flow and Pressure Loss at Inlet Duct (입구덕트 공기유량 및 압력손실 예측방법)

  • Lee, Bo-Hwa;Lee, Kyung-Jae;Yang, Soo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.1
    • /
    • pp.48-55
    • /
    • 2010
  • The purpose of this paper was to address the methodology of the air flow measurement using duct mach number that was considered area-weighed average obtained by total, static pressure and temperature measured at engine inlet duct. Without installing boundary rake, the prediction of air flow measurement was discussed. Actual air flow measurement and pressure value using pressure loss through inlet seal were described to improve the reliability and operability of altitude engine test facility.

The Air Flow Measurement and Prediction of Pressure Loss at Engine Inlet Duct (엔진 입구 덕트에서 공기유량 측정 및 압력손실 예측방법)

  • Lee, Bo-Hwa;Yang, In-Young;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.29-34
    • /
    • 2007
  • The purpose of this paper was to address the methodology of the air flow measurement using duct mach number that was considered area-weighed average obtained by total pressure and temperature measured at engine inlet duct. Without installing boundary rake, the prediction of air flow measurement was discussed. Actual air flow measurement and pressure value using pressure loss through inlet seal were described to improve the reliability and operability of altitude engine test facility.

  • PDF

Temperature Variation of Exhaust Gas in Diesel Generator for Low Pressure SCR (저압 SCR을 위한 디젤발전기 배기가스 온도 변화)

  • Hong, Chul Hyun;Lee, Chang Min;Lee, Sang Duk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.2
    • /
    • pp.355-362
    • /
    • 2021
  • To facilitate low-pressure selective catalyst reduction (L.P SCR), a high exhaust-gas temperature of a four-stroke diesel engine for a ship's generator is required. This study aimed at reducing the exhaust-gas temperature by adjusting the valve open-close timing and fuel injection timing to satisfy the operating conditions of L.P SCR and prevent accidents associated with the generator engine due to high temperature. To lower exhaust-gas temperature, the angle of the camshaft was adjusted and the shim of the fuel injection pump was added. As a result, the maximum explosion pressure increased and the average of the turbocharger outlet temperature dropped. Considering the heat loss from the turbocharger outlet to the SCR inlet, the operation condition for L.P SCR was satisfied with 290 ℃. The study demonstrates that safe operation of a diesel generator can be achieved by lowering the exhaust-gas temperature.

Heat Transfer Characteristics of Cost Effective Plate Fin-tube Condenser for Household Refrigerator (가정용 냉장고의 응축기 비용저감을 위한 판형 핀-관 열교환기의 열전달 특성)

  • Son, Young-Woo;Lee, Jang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.323-327
    • /
    • 2008
  • 본 연구는 판형 핀-관 열교환기의 열전달 특성을 상용 CFD 코드인 SC/Tetra를 사용하여 해석한 내용에 관한 것이다. 해석조건은 입구속도 0.63 m/s, 튜브온도 $44.5^{\circ}C$이다. 해석 열교환기는 총6가지로 검토하였으며 각각의 온도분포와 유동패턴을 해석하고 판형 핀-관 열교환기의 열전달 특성을 비교 검토하였다.

  • PDF

Numerical Study of Hydrogen/Air Combustion in Combustion Chamber of Ultra Micro Gas Turbine by Change of Flow Rate and Equivalence Ratio (공급 유량 및 당량비 변화에 따른 초소형 가스터빈 연소실 내 수소/공기 연소의 수치해석 연구)

  • Kwon, Kilsung;Hwang, Yu Hyeon;Kang, Ho;Kim, Daejoong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.103-109
    • /
    • 2013
  • In this study, we performed a numerical study of hydrogen/air combustion in the combustion chamber of an ultra micro gas turbine. The supply flow rate and equivalence ratio are used as variables, and the commercial computational fluid dynamic program (STAR-CCM) is used for the numerical study of the combustion. The flow rate significantly affects the flame position, flame temperature, and pressure ratio between the inlet and the outlet. The flame position is close to the outlet in the combustion chamber, and the flame temperature and pressure ratio monotonously increases with the supply flow rate. The change in the equivalence ratio does not affect the flame position. The maximum flame temperature occurs under stoichiometric conditions.

ITER HCCR TBM 헬륨냉각계통 개발을 위한 헬륨공급장치 구축 및 실험계획

  • Lee, Eo-Hwak;Kim, Seok-Gwon;Jin, Hyeong-Gon;Yun, Jae-Seong;Jo, Seung-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.465-465
    • /
    • 2014
  • 증식블랑켓모듈(TBM, Test Blanket Module)을 개발하여 왔다. 이 두 증식블랑켓모듈은 모두 헬륨냉각을 기반으로 개발 되어왔으며 이에 따라, 헬륨순환기, 헬륨히터 및 헬륨열교환기 등에 대한 기본적인 연구가 수행되었다. 이후 2012년 고체형 증식블랑켓모듈을 ITER TBM 개념으로 주도하기로 결정함에 따라, HCCR (Helium Cooled Ceramic Reflector) TBM의 보조계통인 하나인 헬륨냉각계통(HCS, Helium Cooling System)에 대한 개발이 본격적으로 이루어졌다. 한국원자력연구원에서는 HCCR TBM의 냉각성능을 만족하기 위하여 8 MPa, 1.5 kg/s 및 $300/500^{\circ}C$ (입구/출구 온도)의 운전조건을 갖는 헬륨냉각계통의 설계를 완료하였다. 설계된 헬륨냉각계통은 HCCR TBM에서 회수된 약 $450^{\circ}C$의 헬륨을 열회수기(recuperator)기와 냉각기를 통해 상온으로 냉각시킨 후, 필터를 통해 헬륨을 여과시킨다. 여과된 헬륨은 헬륨순환기에 의해 가압되어 열회수기를 다시 지나 $300^{\circ}C$ 이상으로 가열된다. 가열된 헬륨은 열회수기를 지나지 않는 상온의 헬륨과 혼합되어 최종적으로 HCCR TBM의 입구온도 조건인 $300^{\circ}C$로 맞추어 HCCR TBM에 공급된다. 이러한 열회수기 중심으로 '${\infty}$' 모양의 자가 교차로 설계된 헬륨냉각계통은 고온영역과 저온영역으로 냉각회로를 구분하여 순환기, 필터 및 각종 계측기의 운전온도 환경을 상온으로 유지시킬 수 있어 운전 및 유지보수 관점에서 이점이 있다. HCCR TBM의 헬륨냉각계통 설계 및 핵심 기기를 실증하고, 운전 경험을 쌓기 위하여 헬륨공급장치(HeSS, Helium Supply System)를 헬륨유량기준 1/3 규모(0.5 kg/s)로 구축하였으며, '14년까지 HeSS를 실증규모로 업그레이드 하기 위하여 80기압 환경에서 압축비 1.1, 유량 1.5 kg/s의 성능을 내는 헬륨순환기를 설치할 예정이다. 현재 구축된 1/3 규모 HeSS는 국내 구축된 전자빔 고열부하 시험 장비인 KoHLT-EB (Electron Beam)와 연계되어 HCCR TBM의 일차벽(플라즈마 대향부품)을 검증할 예정이며, 이를 통해 얻어진 열수력 DB는 현재 개발중인 핵융합로 안전해석코드인 GAMMA-FR 검증에 활용될 계획이다.

  • PDF

A Dynamic Simulation for Small Turboshaft Engine with Free Power Turbine Using The CMF Method (CMF 기법을 이용한 소형 분리축 방식 터보축 엔진의 동적모사)

  • 공창덕;기자영
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.1
    • /
    • pp.13-20
    • /
    • 1998
  • A steady-state and dynamic simulation program for a small multi-purpose turboshaft engine with the free power turbine was developed. In order to reduce developing cost, time and risk, a turbojet engine whose performance was well-known was used for the gas generator, and life time was improved by replacing turbine material and by using Larson-Miller curves. The component characteristic of the power turbine was derived from scaling the gas generator turbine. Equilibrium equations of mass flow rate and work were used for the steady-state performance analysis, and the Constant Flow Method(CMF) was used for the dynamic performance simulation. The step fuel scheduling was carried out for acceleration in the dynamic simulation. Through this simulation, it was found that the overshoot of the turbine inlet temperature exceeded over the compressor turbine limit temperature.

  • PDF