• Title/Summary/Keyword: 입구온도

Search Result 347, Processing Time 0.019 seconds

Analysis of temperature distribution per length in highway tunnel (공용중인 고속도로 터널내 연장별 온도 조사 분석)

  • Hong, Seung-Ho;Lee, Kyung-Ha;Kim, Nag-Young;Yun, Kyong-Ku
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.3
    • /
    • pp.259-267
    • /
    • 2005
  • This paper analyzed characteristic of temperature change as well as bottom of tunnel with thermometer according to tunnel length and region during one year. And it measured temperature distribution near tunnel portal. In the paper it was known that tunnel entrance and exit have different characteristic temperature distribution in accordiance with bottom of tunnel per tunnel length. Temperature of tunnel changed from tunnel exit to fifty meter and distribution of tunnel temperature was established uniform regardless of tunnel length. But temperature distribution of tunnel changed in tunnel entrance differ from tunnel exit in the location of one hundred twenty five meter and one hundred fifty meter. Cold air inflowed from tunnel entrance have influenced with the location of one hundred twenty five meter and one hundred fifty meter.

  • PDF

A Study on Real Time Linear Simulation and Turbine Inlet Temperature Control of Aircraft Turbojet Engine (항공기용 터보제트 엔진의 실시간 선형모사와 터빈 입구온도 제어에 관한 연구)

  • 기자영;김석균;공창덕
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.97-104
    • /
    • 1996
  • DYGABCD 프로그램을 이용해 선형모델의 구성에 필요한 시스템 행렬을 구하고 최소자승법을 이용하여 실시간 선형모사를 행한 후 DYNGEN 프로그램을 이용한 비선형 모사와 비교하여 그 타당성을 입증하였다. 그리고 가제어성과 가안정성을 시험하여 시스템에 대해 제어기설계가 가능한지 확인하고 엔진의 성능과 직결되는 터빈입구 온도의 Overshoot 제어를 위해 고전적 제어기법인 PI제어기와 현대적 최적제어기법인 LQR 제어기를 설계하여 각각의 성능을 비교해 보았다.

  • PDF

Study on Effect of Increase in Inlet Temperature on Nafion Membrane Humidifier (입구온도 변화가 중공사형 나피온 막가습기의 성능에 미치는 영향에 대한 연구)

  • Hwang, Jun-Young;Chang, Hyo-Sun;Kang, Kyung-Tae;Kang, Heui-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.361-369
    • /
    • 2011
  • The effect of an increase in the temperature of inlet air on the performance of a membrane humidifier for a PEMFC (Polymer Electrolyte Membrane Fuel Cell) vehicle was investigated both experimentally and numerically. A shell-and-tube type gas-to-gas humidifier with Nafion membrane was tested. The experimental result showed that water transfer varies nonlinearly with the temperature elevation. Numerical analysis based on detailed modeling was also conducted in simplified geometry of a single tube to explain this nonlinear behavior. The simulation revealed that the local water flux varies nonlinearly and dramatically along the tube. The analysis was based on the inverse relationship between the increase in temperature and decrease in relative humidity, both of which seriously affect the water conductivity of the membrane.

Flow and Heat Transfer Characteristics of a Circular Cylinder with the Periodic Inlet Velocity (주기적인 입구 속도 변동에 따른 원관 주위 유동 및 열전달 특성)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.27-32
    • /
    • 2019
  • In this study, the vorticity distribution and the temperature distribution change around a circular cylinder were compared and analyzed with time for constant inlet velocity and periodic inlet velocity. Also, the frequency characteristics of the flow were analyzed by analyzing the time variation of lift and drag and their PSD(power spectral density). In the case of constant inlet velocity, the well known Karman vorticity distribution was shown, and vortices were alternately generated at the upper and lower sides of the circular cylinder. In case of periodic inlet velocity, it was observed that vortex occurred simultaneously in the upper and lower sides of the circular cylinder. In both cases, it was confirmed that the time dependent temperature distribution changes almost the same behavior as the vorticity distribution. For the constant inlet velocity, the vortex flow frequency is 31.15 Hz, and for the periodic inlet velocity, the vortex flow frequency is equal to the preriodic inlet velocity at 15.57 Hz. The mean surface Nusselt number was 99.6 for the constant inlet velocity and 110.7 for the periodic inlet velocity, which showed 11.1% increase in surface heat transfer.

Non-gray Radiation with Turbulent Convection in the Entrance Region of a Smooth Tube (매끈한 튜브의 입구 영역에서 난류유동에 의한 대류와 비회복사)

  • Seo, T.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.667-680
    • /
    • 1995
  • 튜브 내의 입구영역에서 난류 유동에 의한 대류와 비회복사(non-gray radiation)가 동시에 일어날 때의 열전달특성을 수치해석적으로 연구하였다. 작동유체는 이산화탄소, 수증기, 질소의 혼합가스라고 가정하였다. 지배방정식을 계산하기 위해 유한차분법이 이용되었고, 복사전달방정식을 이차편미분방정식으로 바꾸기 위해 P-1 근사법이 사용되었다. 그리고 혼합가스의 비회흡수계수(non-gray absorption coefficient)는 지수광폭밴드모형(exponential wide band model)을 이용해서 구하였다. 열전달특성에 대한 온도조건의 영향을 조사하기 위해 튜브의 축방향에 대한 평균 온도와 뉴셀트수(Nusselt number)의 변화를 몇 가지 다른 온도조건에 대해 나타내었다. 또한, 가스의 성분조성에 대한 영향을 조사하였으며, 이러한 결과에 기초해서 튜브 내에서 난류유동에 의한 대류와 비화복사가 동시에 일어날 때의 복사 뉴셀트수를 쉽게 예측할 수 있는 방법을 제시하였다.

  • PDF

Optimal Condition of Specific Impulse for a Liquid Rocket Engine with Film Cooling (막냉각이 적용된 액체로켓엔진의 비추력 최적조건)

  • Cho, Won-Kook;Park, Soon-Young;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.135-140
    • /
    • 2007
  • An analysis has been conducted of the optimal condition to maximize the specific impulse for a liquid rocket engine with film cooling. The present engine performance has been compared with the published conceptual design to be verified satisfactorily accurate. The optimal combination of film coolant flow rate and the regenerative cooling capacity has been found for maximum specific impulse. The optimal fuel pump pressure increases and the optimal film coolant flow decreases for a larger thrust engine. Higher turbine inlet temperature increases both the fuel pump pressure and the film coolant flow rate as the optimal condition. The coking temperature has the same qualitative effect as the turbine inlet temperature.

  • PDF

Heat Recovery System from Chamber of Agricual Products Dryer (농산물건조기의 배풍열 재이용 기술에 관한 연구)

  • Paek, Y.;Kim, Y.J.;Kang, G.C.;Ryou, Y.S.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.07a
    • /
    • pp.241-246
    • /
    • 2002
  • 본 연구는 농산물을 건조할 때 배풍구로 버려지는 열을 회수하여 건조열원으로 재이용할 수 있는 배풍열 회수장치를 개발하여 연료절감 및 열회수장치의 성능을 분석한 연구 결과 다음과 같은 결론을 얻었다. 가. 농산물건조기의 열수지를 분석한 결과 투입열량을 100%로 하였을 경우, 배기열은 13.2%, 배풍역량 77.7%, 관류열량은 9.1%로 나타났다. 나. 고추를 건조시 배풍구입구온도가 55-6$0^{\circ}C$일 때 배풍구 출구온도 41-43$^{\circ}C$, 일때 흡입구 입구온도는 25-28$^{\circ}C$, 흡입구 출구온도는 41-43$^{\circ}C$로 나타나 건조실로 41-43$^{\circ}C$의 높은 온도를 투입할 수 있었다. 다. 배풍열 량이 단위 시간당 4700kca1에서 6000kca1로 증가할 때, 흡입 열량은 2200kca1에서 3000kca1로 나타났다. 라. 고추의 초기함수율이 80%에서 15%까지 떨어지는데 관행건조는 약 27시간이 경과했으며, 배풍연회수건조를 할 경우는 약 24시간이 경과했으며 그 결과 배풍열 회수건조가 약 3시간정도 소요시간이 단축되었음을 알 수 있었음. 마. 배풍열 회수장치를 사용하여 농산물건조기 투입량의 47%, 배풍열량의 64%의 열량을 회수할 수 있었다. 바. 배풍열 회수 농산물건조기 성능시험 결과 고추 100kg 건조시 연료소모량은 43%, 건조 소요비용은 21% 감소시킬 수 있었다.

  • PDF

Flow and Heat Transfer Characteristics of Heat Exchanger Tube Bank with the Sinusoidal Inlet Velocity (정현파 입구 속도 변동에 따른 열교환기 관군의 유동 및 열전달 특성)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.1
    • /
    • pp.14-19
    • /
    • 2021
  • The change of the vorticity and the temperature distribution in heat exchanger tube bank were analyzed for the flows with the constant inlet velocity and the sinusoidal inlet velocity. The flow frequency characteristics were examined by analyzing power spectral density of lift and drag at a typical circular tube in the tube bank. Karman vortex street could be seen at the upstream region of tube bank for the case of constant inlet velocity. It could be seen that the Karman vortex street was affected by the change of inlet velocity near the circular tubes for the case with the sinusoidal inlet velocity. It was observed that the unsteady temperature distributions for both inlet velocity conditions had almost the same motion as the flow vorticity behavior. The flow frequency for the case with the constant inlet velocity is 37.25Hz, and that with the sinusoidal inlet velocity, the flow frequency is 18.63Hz, which is equal to the sinusoidal inlet velocity. The mean surface Nusselt number(Nu) for overall heat exchanger tube bank was 1051 for the case with the constant inlet velocity and 1117 for the case with the sinusoidal inlet velocity. From the result of heat transfer analysis, it could be seen that Nu with the sinusoidal inlet velocity showed 6.3% increase than that with the constant inlet velocity.

밀봉수주입 열교환기의 비정상 열전달 특성

  • 장근선;진승령;손용수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.352-357
    • /
    • 1995
  • 원자력발전소 화학 및 체적제어계통의 일부인 밀봉수주입계통은 원자로 냉각재펌프 밀봉장치로 일정한 온도 범위의 밀봉수를 공급하여 밀봉장치의 건전성 및 원자로 냉각재 계통의 압력경계를 유지한다. 그러나 발전소 과도상태시 밀봉수 주입온도가 허용범위를 벗어나게 되면 온도조절기 폐쇄신호에 의해 밀봉장치로의 밀봉수 주입이 차단될 수 있다. 본 연구에서는 발전소 과도시에도 밀봉수 주입이 지속적으로 가능한 설계개선 방안으로 밀봉수주입 열교환기 주위에 우회라인을 설치하는 방안을 제시하고 밀봉수주입 열교환기 내에서의 비정상 열전달 현상을 수치해석을 이용하여 분석하였다. 계산은 속도장을 정상 상태인 power-law분포로 가정하고 시간 t=0에서 입구온도가 급격히 변하는 과도시 우회 유량 및 시간 변화에 대한 온도분포, 국부 Nusselt 수, 평균온도 등을 구하였다.

  • PDF

Study on the Energy Separation Characteristics of the $20Nm^3$/hr Level Vortex Tube ($20Nm^3$/hr급 볼텍스튜브의 에너지 분리 특성 연구)

  • Kim, Chang-Su;Park, Sung-Young
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.687-690
    • /
    • 2009
  • 고압의 가스를 이용하여 고온 가스와 저온 가스를 분리하거나 입자상 물질의 분리에 사용할 수 있는 장치인 볼텍스 튜브의 에너지 분리 특성을 파악하기 위하여 $20Nm^3$/hr급 볼텍스 튜브를 제작하고 이에 대한 실험을 진행하였다. 입구 압력, 저온측의 유량비가 온도에 미치는 영향을 분석하였다. 입구 압력이 높아질수록 고온측의 온도는 증가하고, 저온측의 온도는 강하하였다. 저온 유량비 80%를 전후하여 고온측 온도가 최고점을 나타냈고, 저온유량비 40%를 전후하여 저온측 온도가 최저점을 나타냈다.

  • PDF