• Title/Summary/Keyword: 임플란트 환자

Search Result 504, Processing Time 0.025 seconds

A Prospective Clinical Trial on the Mg Oxidized Clinical Implants (마그네슘 양극산화 임플란트의 성공률에 관한 전향적 임상연구)

  • Im, So-Min;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra;Um, Heung-Sik;Lee, Jae-Kwan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.25-39
    • /
    • 2011
  • In animal studies, Magnesium (Mg) - incorporated oxidized implants showed significant enhancement of the bone response. This prospective clinical trial was performed to investigate the success rate, implant stability and marginal bone loss of Mg oxidized clinical implant. The experimental protocol was approved by Institutional Review Board of the Gangneung-Wonju National University Dental Hospital. Fifty healthy patients had partial edentulism were included in this study. Mg oxidized clinical implants (Implant M, Shinhung, Korea) were installed and restored with conventional protocol. The patients were recalled at 1, 3, 6 months after functional loading. Implant stability quotient (ISQ) was measured and periapical radiographic images were obtained. Amount of marginal bone loss was calculated with calibrated images from periapical radiographs. Repeated measured analysis of variance and post hoc Tukey test were used to compare the mean ISQ and bone level. A total of 101 implants were analyzed. The mean ISQ values increased continuously with time lapse from 68.4 at fixture installation to 71.5 at 6 months after loading. Implant stability was correlated with gender, fixture diameter, bone quality and implant sites. The mean marginal bone loss during 6 months after loading was 0.26 mm. There was no failed implant and six-month success rate was 100%. Within the limitations of this study, the six-month success rate of Mg oxidized implant was satisfactory. The implant stability and marginal bone level were excellent. However, further longer clinical studies will be needed to confirm the success of Mg oxidized clinical implant.

Various solutions of open interproximal contact (OIC) (OIC (open interproximal contact)의 다양한 해결 방법)

  • Park, Jong-Hyun;Cho, Lee-Ra
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.18-26
    • /
    • 2019
  • Open interproximal contact (OIC) is a phenomenon that can be observed to occur between an implant restoration and the adjacent tooth Food packing is very uncomfortable for patients. Efforts to relieve discomfort in various ways seem necessary.

Digital impression taking for full-arch implant restoration to a patient with microstomia (디지털 인상채득을 이용한 소구증을 가진 환자의 전악 임플란트 수복)

  • Shim, Ji Suk;Ryu, Jae Jun
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.616-621
    • /
    • 2018
  • This clinical case highlights the failure of long length implants, and the prosthodontic procedures necessary to rehabilitate the maxillary dentition of a patient with microstomia. The integrated digital technology of intra-oral scanning, computer-aided design, and three-dimensional printing can provide an alternative method to make conventional impressions for patients with microstomia who cannot insert the appropriate tray in their mouths.

  • PDF

Digital workflow for prosthetic restoration in the pan facial fracture patient: A case report (다발성 안면 골절 환자의 보철 수복을 위한 디지털 워크플로우: 증례보고)

  • Kim, Seung-Wan;Park, Geun-Taek;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra;Ko, Kyung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.395-403
    • /
    • 2022
  • In the fracture operation of pan facial fracture, there are many cases where the shape and position of the occlusal and oral structures are abnormally changed because the index for repositioning to the original position is insufficient. And trismus and gag reflex in patients with pan facial fractures increase the difficulty of dental treatment, and the difference in the position of the jaw bone makes it difficult to restore aesthetically and functionally. In this case, digital workflows for minimal intraoral work could be selected to reduce patient discomfort and the difficulty of dental treatment. This case is using a digital workflow from implant planning to final prosthesis production in a patient with acquired skeletal grade III, trismus, and gag reflex due to pan facial fracture 15 years ago. In this case report, the use of digital workflow in a patient who has difficulty in dental treatment was able to minimize patient discomfort and obtain esthetic and functionally appropriate results.

Using implants for worn dentition with the altered vertical dimension of occlusion based on shortened dental arch concept: a case report (과도한 마모를 보이는 환자에서, 임플란트를 활용해 수직 고경을 증가시키며 shortened dental arch 개념을 적용한 보철 수복 증례)

  • Lee, Jae Hyun;Kim, Tae Su;Lee, Chul Won;Lee, Won Sup;Lee, Su Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • Excessive occlusal wear can result in unacceptable damage to the residual teeth structure, anterior guidance and masticatory function. An 86-year-old man presented with worn dentition and anterior deep bite due to loss of the posterior support. Two implants covered by Korean national health insurance, fixed partial denture and direct composite resin were used to restore the dentition, instead of removable prosthesis. The occlusal vertical dimension was increased by 2 mm in the premolar area and shortened dental arch concept was applied. This treatment was a less expensive alternative to full-mouth rehabilitation with positive esthetic and functional outcomes after 7 months of follow-up.

3D analysis of soft tissue around implant after flap folding suture (Flap folding suture를 활용한 판막의 고정에 따른 임플란트 주변 연조직 3차원 부피 변화 관찰)

  • Jung, Sae-Young;Kang, Dae-Young;Shin, Hyun-Seung;Park, Jung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.130-137
    • /
    • 2021
  • Purpose: The various suture techniques can be utilized in order to maximize the keratinized tissue healing around dental implants. The aim of this study is to compare the soft tissue healing pattern between two different suture techniques after implant placement. Materials and Methods: 15 patients with 18 implants were enrolled in this study. Simple implant placement without any additional bone graft was performed. Two different suture techniques were used to tug in the mobilized flap near the healing abutment after paramarginal flap design. Digital intraoral scan was performed at baseline, post-operation, stitch out, and 3 months after operation. The scan data were aligned using multiple points such as cusp, fossa of adjacent teeth, and/or healing abutment. After subtracting scan data at baseline with other time-point results, closed space indicating volume increment of peri-implant mucosa was selected. The volume of the close space was measured in mm3. The volume between two suture techniques at three time-points was compared using nonparametric rank-based analysis. Results: Healing was uneventful in both groups. Both suture technique groups showed increased soft tissue volume immediately after surgery. The amount of volume increment significantly decreased after 3 months (P < 0.001). Flap folding suture group showed higher median of volume increment than interrupted suture group after 3 months without any statistical significance (P > 0.05). Conclusion: After paramarginal flap reflection, the raised flaps stabilized by flap folding suture showed relatively higher volume maintenance after 3-month healing period. However, further studies are warranted.

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

Gingival mask using 3D Printer for a patient with palatally installed implant in maxillary anterior area (구개측으로 식립된 상악 전치부 임플란트 환자에서 3D 프린터를 이용한 Gingival mask 수복 증례)

  • Jeong, Kyong-Sik;Kim, Na-Hong;Kim, Sung-Yong;Lee, Yong-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.363-368
    • /
    • 2020
  • The prosthesis of the implant installed in inappropriate positions presents aesthetic and functional problems. If the implants are placed in the wrong position, re-implantation is often limited. There are surgical and non-surgical methods for resolving complications without re-implantation. The surgical costs, healing time, discomfort and unpredictability make this choice unpopular. On the other hand, a gingival mask has the advantage of solving complications quickly and simply. The patient was a 80-year-old male with palatally installed implant in maxillary anterior region and dissatisfied with his unesthetic philtrum and food impaction between the upper lip and the prosthesis. It was difficult to predict the prognosis of surgical operation, and the patient wanted treatment economically and physically burdenless because of his age and financial situation. Thus, the gingival mask was planned and the results were satisfactory.

The Effective Utilization of GBR and VIP-CT(Vascularized Interpositional Periosteal Connective Tissue) graft in the Anterior Maxillary Immediate Implantation : A Clinical Case Report (상악 전치부 발치 즉시 식립시 골유도재생술과 혈관개재 골막-결합조직 판막술(VIP-CT graft)의 활용)

  • Lim, Pil
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.74-85
    • /
    • 2019
  • The aesthetic restoration of dental implants in the anterior maxilla is a challenge for clinicians because it requires proper harmony in three following conditions; reconstruction of hard tissue, soft tissue, and aesthetic prosthesis. A newer technique, VIP-CT (Vacularized Interpositional Periosteal Connective Tissue) graft has been introduced as an alternative to these technique which allows the clinicians perform large volume soft tissue augmentation in esthetic sites with a single procedure. The advantages of the VIP-CT graft technique are that it allows the reconstruction of large soft tissue deficiency, with little constriction postoperatively. Furthermore, it facilitates improved hard tissue augmentation due to the additional blood supply and improved bone healing by mesenchymal cells. Moreover, this technique reduces patient discomfort and treatment time. This clinical report describes the procedure of bone augmentation during immediate implantation in facial dehiscence defect, especially Vascularized Interpositional Periosteal Connective Tissue(VIP-CT) graft for aesthetic anterior soft tissue.