• Title/Summary/Keyword: 임플란트 가이드 수술

Search Result 60, Processing Time 0.029 seconds

An assessment of accuracy of half-guided implant surgery using implant surgical guide: A case report (임플란트 수술용 가이드를 사용한 부분 유도 임플란트 수술의 정확도 평가: 증례보고)

  • Kim, Choongkil;Lee, Wonsup;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.150-159
    • /
    • 2019
  • Nowadays, dental implant is one of the widely used treatment options for edentulous patients. Recently, a method of improving the accuracy of implant surgery using an implant surgical guide has been introduced and widely used in order to accurately place the implant in a proper position. Full-guided and half-guided implant surgery can be distinguished according to the level of surgical guide application during the implant surgery. It is true that full-guided implant surgery exhibits higher accuracy, but half- guided implant surgery is often performed in a clinical situation due to the factors such as the circumstances of the operation. A partially edentulous patient who lost teeth due to tooth fracture and periodontal disease was treated using implant and fixed prosthesis. Half-guided implant surgery was performed using an implant surgical guide during implant surgery, the accuracy of implant placement was analyzed.

Accuracy assessment of implant placement using a stereolithographic surgical guide made with digital scan (디지털 스캔을 이용하여 제작된 임플란트 수술가이드의 정확도)

  • Jeong, Seung-Mi;Fang, Jeong-Whan;Hwang, Chan-Hyeon;Kang, Se-Ha;Choi, Byung-Ho;Fang, Yiqin;Jeon, Hyongtae;An, Sunghun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • Purpose: The objective of this study was to evaluate the accuracy of a stereolithographic surgical guide that was made with information from intraoral digital impressions and cone beam CT (CBCT). Materials and methods: Six sets of resin maxilla and mandible models with missing teeth were used in this study. Intraoral digital impressions were made. The virtual models provided by these intraoral digital impressions and by the CBCT scan images of the resin models were used to create a surgical guide. Implant surgery was performed on the resin models using the surgical guide. After implant placement, the models were subjected to another CBCT scan to compare the planned and actual implant positions. Deviations in position, depth and axis between the planned and actual positions were measured for each implant. Results: The mean deviation of the insertion point and angulation were 0.28 mm and $0.26^{\circ}$, apex point were 0.11 mm and 0.14 mm respectively. The implants were situated at a mean of 0.44 mm coronal to the planned vertical position. Conclusion: This study demonstrates that stereolithographic surgical guides created without the use of impressions and stone models show promising accuracy in implant placement.

A case report of a surgical guide fabricated via intraoral scanning-based implant planning and wax-based rapid prototyping (구강스캐너를 이용한 임플란트 수술 계획 및 왁스 기반 쾌속조형법으로 제작한 수술용 가이드 증례)

  • Shin, Jong-Hoon;Park, Eun-Jin;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.244-249
    • /
    • 2015
  • With the recent progress of digital technology, the computer guided surgery utilizing a guide template in the placement of implant has been actively performed, and the method employing the intraoral scanner at the implant prosthesis introduced. Fabrication method of the guide template can be largely classified into design-related rapid prototyping (RP) system and vector milling system, and each of the method has its own weakness in the clinical application despite of excellent accuracy. Thus, in this case study, a working model was fabricated by the wax RP technology using images acquired by CBCT and an intraoral scanner, and the metal bushing was picked up with orthodontic resin cast upon the wax model. Using this method, a surgical guide template was fabricated and used in surgery. From this, we could obtain a satisfactory outcome clinically in the implant placement and the fabrication of the final prostheses and thus report this case herein.

Implant placement using a newly developed CT-based guide program and subtractive manufacturing: case reports (새로 개발된 3차원 영상 기반의 임플란트 가이드 프로그램과 삭제 공정을 이용한 임플란트 계획 및 식립: 증례보고)

  • Park, Jung-Wan;Kim, Kyung-Rok;Kang, Hye-Won;Lee, Kyu-Bok;Lee, Du-Hyeong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.67-74
    • /
    • 2015
  • Computer-guided surgery utilizing computed tomography is advantageous in placing implants precisely and conveniently. The purpose of the cases was to report a newly developed CT-based guide fabrication program and subtractive manufacturing using resin block. The guided surgery with the program and subtractive manufacturing allows not only precise translation of the treatment plan, but also offers additional significant benefits.

Radiographic evaluation of marginal bone level alteration around narrow implants placed in narrow alveolar ridge using guided flapless surgery (폭이 좁은 치조골에서 컴퓨터가이드를 이용한 무절개 임플란트 수술로 식립한 narrow implant의 방사선학적 평가)

  • Jeong, Seung-Mi;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.306-312
    • /
    • 2020
  • Purpose: The aim of this study was to compare radiographic outcomes around narrow-diameter implants placed using guided flapless surgery at longer than 6 month post-placement. Materials and methods: A total of 12 implants were assessed in 12 patients for the sites where 0.5 - 1.5 mm labial bone was covering the implants, using CBCT. Results: A statistically significant preservation of crestal bone was observed in the narrow-diameter implants. Conclusion: Guided flapless implant surgery may be important in preventing bone loss around the narrow-diameter implants that are placed in narrow alveolar ridges.

Implant-supported milled bar overdenture with two implant surgical guides (두 개의 수술용 가이드와 Milled-bar를 이용한 임플란트 피개 의치 수복 증례)

  • Pill-Sang Yun;Sunjai Kim;Se-Wook Pyo;Jae-Seung Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.55-62
    • /
    • 2023
  • For fully edentulous patients, implant-supported overdenture can be considered to enhance chewing efficiency and denture stability. Implant planning software can be used to fabricate a surgical guide for a more precise consideration of anatomic factors and prediction of the shape of definitive prosthesis. Though there are many possible attachments for implant overdenture, milled bar can be useful due to its splinting effect of implants and rigid support of overdenture. This report presents a case of implant-supported milled bar overdenture after guided implant surgery performed with two surgical guide that was fabricated before and after bone reduction.

Flapless implant placement with digital 3D imaging and planning system in fully edentulous patient: A case report and 5-year follow-up (완전무치악 환자에서 디지털 가이드 수술 방식을 이용한 무피판절개 임플란트 식립증례: 증례보고 및 5년 추적관찰)

  • Shin, Mi-sun;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.312-320
    • /
    • 2019
  • One of the fastest growing segments of implant dentistry is the utilization of computed tomography (CT) scan data and treatment planning software in conjunction with guided surgery for implant reconstruction cases. Computer assisted planning systems and associated surgical templates have established a predictable, esthetic, functional technique for placing and restoring implants. Especially, a philosophy of restoratively driven implant placement has been generally adopted. Recently, a variety of commercial dental fields have released their scanning and fabricating protocols and methods for restorations. This process is still being investigated and developed for the most precise and predictable outcome. This case report describes a female patient who wanted dental implants in fully edentulous areas. Restoratively driven implant placements were performed with surgical guide and the patient was fully satisfied with the clinical results, and at 5-year post restorative follow-up assessment, both implant and prosthesis were proved clinical success.

The use of surgical guide stent for implant placement (임플란트 식립을 위한 수술 가이드의 사용)

  • Lee, Ji-Yeon;Yoon, Ji-Young;Oh, Namsik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.366-375
    • /
    • 2014
  • Surgical guide not only provide diagnosis and treatment plan, but even location and direction of implantation. Surgical guide could be divided into non-limited design, partially limited design, and completely limited design. Partially limited design is easily manufactured and inexpensive but less accuracy, compared to completely limited design. From this approach, partially limited design may be particularly effective in patients who present with a single missing tooth or partially edentulous teeth. Completely limited design is anatomically accuracy, esthetical and functional, optimized treatment for prosthetic and biomechanical perspective, and also minimizes discomfort for post-treatment. The purpose of this study is to review previous studies of various surgical guides and applying in clinic.

The effect of guided flapless implant procedure on heat generation from implant drilling (수술가이드를 이용한 무피판 임플란트 술식에서 임플란트 드릴링이 열발생에 미치는 효과)

  • Yoo, Je-Hyeon;Jeong, Seung-Mi;Choi, Byung-Ho;Joo, Sang-Don
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.11-19
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the heat generation in bone in vitro during the guided flapless drilling procedure and the effect of drilling methods on the heat generation. Materials and methods: A model that has missing the first and second mandibular molars bilaterally was used. In group A, classical flap implant surgery was performed. In group B, flapless implant surgery using surgical guide was performed. In group C, flapless implant surgery using surgical guide without up-and-down pumping motion was performed. Temperature was measured with k-type thermocouple and a real-time digital thermometer. The thermocouples were placed at 0.5 mm away from the osteotomy area at the depths of 3 mm and 6 mm. The measured values were evaluated with independent t-test. Results: The mean temperature generated was $27.2^{\circ}C$ ($SD{\pm}2.1^{\circ}C$) and $27.5^{\circ}C$ ($SD{\pm}2.3^{\circ}C$) for groups A and B, respectively. These differences were not statistically significant. In group C, the mean temperature was $37.0^{\circ}C$ ($SD{\pm}3.4^{\circ}C$). There were statistically significant differences between groups B and C with respect to the mean temperature. Conclusion: These findings suggest that guided flapless drilling with up-and-down pumping motion may not significantly increase the bone temperature.

Consideration of computer-guided implant surgery (임플란트 가이드 수술시 고려사항)

  • Kim, Hyun Dong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.4-17
    • /
    • 2019
  • Nowadays, Cone-Beam CT is widely supplied in dental clinics, the distribution rate in south korea is highly ranked worldwidely. Recently, The number of Cone-Beam CTs reached 10 thousands according to national healthcare system report. Also, dental manufacturers released many kinds of In-house 3D digital printers, the distribution rate of which rises rapidly in dental clinics. Accordingly, using Cone-Beam CT data and Intraloral scan data, the application of implant guide surgery is widespread in a unit of private clinic. Through the previous articles, the latest methods of computer-guided implant surgery are reviewed, and also the considerations for precise and reliable guide surgery are summarized.