• Title/Summary/Keyword: 임용규

Search Result 96, Processing Time 0.024 seconds

Shear bond strength of brackets bonded with different self etching primers (Self etching primer를 사용하여 부착된 교정용 브라켓의 전단결합강도의 비교)

  • Yang, Jin-Young;Kim, Min-Ji;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.37 no.4
    • /
    • pp.283-292
    • /
    • 2007
  • The purpose of this study was to evaluate the clinical usefulness of 4 self etching primers by measuring the shear bond strength of orthodontic brackets and examining the failure pattern of bracket-tooth interfaces. Methods: Seventy-five, defect-free, premolars were randomly assigned into five groups: control group (37% phosphoric acid + Transbond XT primer) and self etching primer treated groups (Transbond Plus self etching primer, Unifil bond, Clearfil SE bond, and Adhese). The shear bond strength was measured with a universal testing machine and the amount of residual adhesive remaining on the brackets after debonding was assessed by the adhesive remnant index (ARI). Results: The results showed that the groups conditioned with self etching primer had significantly lower shear bond strength than the control group (p < 0.05), although clinically acceptable. However, there were no significant differences in shear bond strength among the self etching primer groups (p > 0.05). Evaluation of the ARI scores indicated there was less resin remnant on the teeth in the groups conditioned with self etching primers, although not statistically significant. Conclusion: The results of this study suggest that all four of the self etching primers have shown acceptable bond strength for clinical use.

Fracture resistance of ceramic brackets to arch wire torsional force (토오크 양에 따른 세라믹 브라켓의 파절 저항성)

  • Han, Jung-Heum;Chang, Minn-Hii;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.37 no.4
    • /
    • pp.293-304
    • /
    • 2007
  • The purpose of this study was to estimate the fracture resistance of commercially available ceramic brackets to torsional force exerted from arch wires and to evaluate the characteristics of bracket fracture. Methods: Lingual root torque was applied to maxillary central incisor brackets with 0.022-inch slots by means of a $022\;{\times}\;028-inch$ stainless steel arch wire. A custom designed apparatus that attached to an Instron was used to test seven types of ceramic brackets (n = 15). The torque value and torque angle at fracture were measured. In order to evaluate the characteristics of failure, fracture sites and the failure patterns of brackets were examined with a Scanning Electron Microscope. Results: Crystal structure and manufacturing process of ceramic brackets had a significant effect on fracture resistance. Monocrystalline alumina (Inspire) brackets showed significantly greater resistance to torsional force than polycrystalline alumina brackets except InVu. There was no significant difference in fracture resistance during arch wire torsional force between ceramic brackets with metal slots and those without metal slots (p > 0.05). All Clarity brackets partially fractured only at the incisal slot base and the others broke at various locations. Conclusion: The fracture resistance of all the ceramic brackets during arch wire torsion appears to be adequate for clinical use.

A Study on Performance of Indirect-contact Driven-right-leg Ground in Indirect-contact ECG Measurement (간접접촉 심전도 측정에서의 간접접촉 오른발 구동 접지 성능에 대한 연구)

  • Lim, Yong-Gyu;Kim, Ko-Keun;Park, Kwang-Suk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.4
    • /
    • pp.280-287
    • /
    • 2008
  • For the reduction of common-mode noise level in Indirect-contact ECG (IDC-ECG) measurement a driven-right-leg grounding method was a lied to the IDC-ECG. Because the IDC-ECG does not require any direct contact between the electrodes and the human skin. it is adequate for un-constraining long-term ECG measurement at home and its various applications are now under development. However, larger 60 Hz noise induced by power line a ears in IDC-BCG than in conventional ECG, that is a restriction of IDC-ECG a application. In this study, the driven-right-leg ground which has been used in conventional direct-contact ECG, was adapted to the IDC-ECG measurement by feedback of the inversion of amplified common-mode noise to the body through the conductive fertile laid on the chair seat By this study, indirect-contact driven-right-leg ground was developed and it was shown to work stably. It was shown that the level of 60Hz power line noise was reduced to about -40 dB when the driven-right-leg gain was 1000. This study shows that we can extend the upper limit of the frequency band of IDC-ECG to 100Hz from 30Hz which is conventional upper limit in IDC-ECG, and we can raise the ground impedance between the body and conductive textile. So it is expected that the application area of the IDC-ECG will be extended by the results of this study.

  • PDF

AN EXPERIMENTAL STUDY ON THE VASCULAR CHANGES OF RAT MOLAR PERIODONTAL LIGAMENT FOLLOWING ORTHODONTIC TOOTH MOVEMENT USING VASCULAR CORROSION CASTING METHOD (백서구치의 실험적 치아이동시 치근막 혈관변화에 관한 혈관주형법을 이용한 연구)

  • Lim, Yong-Kyu;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.24 no.1 s.44
    • /
    • pp.37-62
    • /
    • 1994
  • This study was undertaken to investigate the three dimensional vascular changes of periodontal ligament following orthodontic tooth movement. Experimental tooth movement was carried out in 96 Sprague-Dawley rats with the weight of 250g. They were divided into four experimental groups (each 24 rats). The left maxillary first molar was moved mesially with 25g force in group I, and with 75g force in group II. Each three animals were sacrificed after 1, 6, 12, 24 hours, and 3, 7, 14, 21 days. In group III, 25g mesial force was applied for 3 days, and in group IV, 75g mesial force was applied for 3 days. Then the appliances were removed, and each three animals were sacrificed after 1, 6, 12, 24 hours, and 3, 7, 14, 21 days from removal of appliance. The contralateral molars were used for control group. Casting media was injected via left ventricle and polymerized in warm water. After corrosion of surrounding soft tissue, three dimensional vascular changes were examined using scanning electron microscopy. The findings of this study were as follows: 1. Pressure side of group I and II showed degenerative vascular changes such as vascular compression, reduction of vasculature, leakage of casting media. But, regenerative changes were dominant after 7 days of tooth movement. Although the degenerative vascular changes were more severe in group II, which was exposed to heavy force, the timing of these changes was not different between two groups. 2. Periodontal vasculature was reestablished by the growth of new capillaries and their differentiation and union from the remaining periodontal vessels and vessels of alveolar bone marrow. Although vascular regeneration was more rapid in group I, which was exposed to light force, the vasculature was not fully normalized in both groups even after 21 days. 3. There was no remarkable changes in tension side of group I and II, but looping of capillary, new capillary growth, dilation of vessels, redirection of vessels in the direction of tensile force were occurred. 4. In pressure side of group III and IV, in which appliance was removed after 3 days of orthodontic force, bone resorption was continued even after removal of appliance. Regeneration of vasculature was initiated after 1-6 hours, and it was more rapid in group III than group IV. In both groups, the vasculature was not fully normalized even after 21 days. 5. After removal of appliance, tension side of group III and IV showed vascular compression and loss of vasculature.

  • PDF

The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods (브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교)

  • Shin, Jai-Ho;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.333-342
    • /
    • 2004
  • The purpose of this study was to evaluate the clinical effectiveness of a plasma arc light and light emitting diode (LED), compared with shear bond strength and the failure pattern of brackets bonded with visible light in direct bonding. Brackets were bonded with Transbond XT to 60 human premolars embedded in the resin blocks according to different light-curing methods. Then, the shear bond strength of each group was measured using a universal testing machine (Instron) and the adhesive failure pattern after debonding was visually examined by light microscope. The results were as follows: 1. The shear bond strength showed no significant difference between the visible light and light emitting diode, but the plasma arc light exhibited a significantly lower shear bond strength compared with the visible light and light emitting diode. 2. In the visible light and light emitting diode, adhesive failure patterns were similar. Bond failure occurred more frequently at the enamel-adhesive interface. 3. The bonding failure of brackets bonded with plasma arc light occurred more frequently at the bracket-adhesive interface. The results of this study suggest that plasma arc light, light emitting diode and visible light are all clinically useful in the direct bonding of orthodontic brackets.

The stability in the adolescent Class III malocclusion treated by fixed appliances (성장기 III급 부정교합의 고정식 교정 치료 후의 안정성)

  • Lim, Yong-Kyu;Lee, Joo-Na;Kim, Joeng-Il;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.313-324
    • /
    • 2004
  • The Purpose of this study was to investigate the predictors of relapse in orthodontic treatment of skeletal Class III malocclusion in growing patients. A total of 55 patients were studied and all subjects were divided into two groups according to their stability in the post-treatment stage. Of the sample, 33 patients were included in the stable group and the remaining 22 were assigned to the relapse group. Cephalometric data of the pre-treatment stage was taken and compared between the stable and relapse group. The following results were obtained through t-test: 1. This study presented statistical evidence to show that the major skeletal determinant of prognosis in Class III orthodontic treatment was not anteroposterior discrepancy .but vertical discrepancy, especially within the AB-maxillo mandibular triangle. Vertical angular measurements that showed statistically significant differences were AB-MP and ODI(P<0.01) and the vortical ratio measurements were MP-P/AL and PP-P/AL(P<0.05). 2. Relapse tendency increased with the steep occlusal Plane, especially the steep lower occlusal plane. As to occlusal plane, there were statistically significant differences in OP(L)-PP, OP-PP, AB-OP(L) and Wits appraisal(P<0.05). This study claimed that anteroposterior discrepancy was not necessarily the proper criteria to predict relapse. Vertical discrepancy had a significant effect on post-treatment stability.

Effect of Plug Cell Size and Variety on the Production of Onion Set for Pickle (플러그 셀 크기와 품종이 절임용 양파 자구 생산에 미치는 영향)

  • Ahn, Su-Ran;Im, Kyung-Ran;Kim, Do-Hun;Suh, Jun-Kyu
    • Journal of Bio-Environment Control
    • /
    • v.21 no.1
    • /
    • pp.28-32
    • /
    • 2012
  • This study was conducted to improve year round production of onion sets for pickles and increase their yield by using different cell sizes of plug trays. 'Josaeng sseondeobol' and 'Daeji' were seeded in 105-cell tray, 128-cell tray, and 162-cell tray on March 27, 2010. 'Josaeng sseondeobol' showed the maximum number of leaves on May 23, but 'Daeji' showed the maximum in late June. Bulbing of 'Josaeng sseondeobol' was already initiated on May 23, but 'Daeji' was initiated on June 6. Growth of both varieties was better in 105-cell tray than the others. There wasn't a difference in bulbing between two varieties by the number of cells, but bulb size was larger in the low number of cells than high ones. 'Josaeng sseondeobol' was all harvested in July, but more than 50% of 'Daeji' was harvested in August. The result of this study is as follows. Harvest time was delayed as the number of cells is increasing. There was a wide range of small onion sets distribution in both varieties as the number of cells is increasing.

Evaluation of friction of esthetic brackets according to different bracket-wire angulations (심미 브라켓의 종류와 브라켓-호선 각도에 따른 마찰 저항에 대한 연구)

  • Je, Young-Ji;Chang, Minn-Hii;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.37 no.5
    • /
    • pp.341-350
    • /
    • 2007
  • The purpose of this study was to evaluate how the friction that occurs during the sliding movement of the archwire through esthetic brackets is differently affected by bracket materials, slot designs, and tip angulations of the archwire. Methods: Eight types of brackets with 0.018 inch slots (composite: Brillant (BR); composite with metal slot: Spirit MB (SP); ceramic: Inspire (IN), Signature (SI), Cristaline V (CR); ceramic with metal slot: Clarity (CL), Luxi II (LU); and metal bracket: Integra (IT)), and placed into groups of 20 brackets in each group, were tested in artificial saliva with 0.018 inch stainless steel wire. The wire tip angulations were given as 0, 4 and 8 degrees. Results: CR group significantly showed the lowest frictional force with all wire tip angulations of 0,4, and 8 degrees. IN significantly showed the highest frictional force (p < 0.001). BR (polyoxymethylene) had significantly less frictional force than SP (polycarbonate) (p < 0.001) and showed no significant difference between metal brackets. Friction was increased as the wire tip angulations were increased, but no notches were observed on any parts of the archwire. Conclusions: According to the results of this study, esthetic brackets are superior or similar to 55 brackets from a frictional point of view.

Shear bond strength of orthodontic adhesive to amalgam surface using light-cured resin (광중합형 레진으로 아말감 면에 브라켓 접착 시 전단결합강도)

  • Cho, Ji-Young;Lee, Dong-Yul;Lim, Yong-Kyu
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.443-450
    • /
    • 2005
  • This study was performed to compare the shear bond strength of orthodontic adhesive to amalgam according to different light sources (halogen-based light and light emitting diode (LED)) and amalgam surface treatments. Ninety extracted human premolars were randomly divided into 6 groups (4 experimental and 2 control groups) of 15 by light sources and surface treatments. Orthodontic brackets were bonded and shear bond strength was measured with an Instron universal testing machine. The findings were as follows: The bond strength of adhesive to amalgam surface was 3-5.5 MPa which was lower than that of acid-etched enamel (19 MPa) control. In the sandblasted amalgam surface, the shear bond strength of the halogen light group was higher than that of the LED group (p < 0.05) but. in the non-treated amalgam surface. there was no significant difference in the shear bond strength according to the light sources (p> 0.05). Within the same light source. sandblasting had no significant effect on the shear bond strength of the adhesive bonded to amalgam surface (p > 0.05). There was no significant difference in shear bond strength according to the light sources in acid-etched enamel control groups. This results suggest that there can be a limit in using light curing adhesives when brackets are bonded to an amalgam surface. Additional clinical studies are necessary before routine use of halogen light and LED light curing units can be recommended in bonding brackets to an amalgam surface.

Fabrication and Characterization of High Performance Green OLEDs using $Alq_3$-C545T Systems ($Alq_3$-C545T시스템을 이용한 고성능 녹색 유기발광다이오드의 제작과 특성 평가)

  • Jang Ji-Geun;Kim Hee-Won;Shin Se-Jin;Kang Eui-Jung;Ahn Jong-Myong;Lim Yong-Gyu
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.1 s.38
    • /
    • pp.51-55
    • /
    • 2006
  • The green emitting high performance OLEDs using the $Alq_3$-C545T fluorescent system have been fabricated and characterized. In the device fabrication, 2-TNATA [4,4',4'-tris(2-naphthylphenyl-phenylamino)-triphenylamine] as a hole injection material and NPB [N,N'-bis(1-naphthyl)-N,N'-diphenyl-1,1'-biphenyl-4,4'-diamine] as a hole transport material were deposited on the ITO(indium thin oxide)/glass substrate by vacuum evaporation. And then, green color emission layer was deposited using $Alq_3$ as a host material and C-545T[10-(2-benzothiazolyl)-1,1,7,7- tetramethyl-2,3,6,7-tetrahydro-1H,5H,11H-[1]/benzopyrano[6,7,8-ij]-quinolizin-11-one] as a dopant. Finally, small molecule OLEDs with structure of ITO/2-TNATA/NPB/$Alq_3$:C545T/$Alq_3$/LiF/Al were obtained by in-situ deposition of $Alq_3$, LiF and Al as the electron transport material, electron injection material and cathode, respectively. Green OLEDs fabricated in our experiments showed the color coordinate of CIE(0.29, 0.65) and the maximum power efficiency of 7.3 lm/W at 12 V with the peak emission wavelength of 521 nm.

  • PDF