• Title/Summary/Keyword: 임시부착물

Search Result 16, Processing Time 0.029 seconds

Evaluation of the heat affection according to the gouging height for low alloy steel structures (가우징 높이에 따른 구조물의 열영향 평가)

  • Ha, Joon-Wook;Yang, Byong-Il;Park, Seong-Jin;Lee, Ki-Hak
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.477-482
    • /
    • 2001
  • A study was performed to determine the optimum height for an arc air gouging of temporary attachments, which were attached at the pressure vessel made of low alloy steel. Frequently, the crack occurred in the base metal by the excessive heat input during an arc air gouging process to remove the temporary attachments. A numerical analysis by 2-dimensional finite element method was performed to calculate the temperature distribution in the base metal during the removal of temporary attachments. And then the mock-up test was performed to verify the numerical results. Numerical values showed good agreement with the experimental results. These results indicated that the defects due to the excessive heat input during an arc air gouging were dependent on the height of temporary attachments remained above hie main products.

  • PDF

Construction Method Improvement of the FRP-plate Strengthening Method using the Velcro (벨크로를 이용한 FRP 플레이트 보강공법의 시공공법 개선)

  • Hong, Geon-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.225-232
    • /
    • 2008
  • The object of this paper is to study the flexural strengthening effectiveness on the construction method of bonding of the FRP. The existing FRP flexural strengthening methods were divided into FRP sheet strengthening and FRP plate strengthening according to the FRP condition. For improving the existing construction method, this paper proposed the velcro type anchorage system for temporary bonding material, and flexural strengthening effects were tested. Test variables were bonding methods of the FRP strengthening materials, and total 4 specimens were tested. Following to the test results, it is shown that FRP-plate strengthening method using the velcro can get better workability than existing construction methods, and have excellent strengthening performance including flexural strength, stiffness, ductility and failure aspect.

Structural behavior on the steel beam with strengthening bonded carbon plate (카본판을 접착보강한 강재의 거동분석)

  • Sung, Ikhyun
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.1
    • /
    • pp.54-61
    • /
    • 2016
  • The use of advanced composite materials in strengthening and repair of existing structures is increasing rapidly. This paper describes an effectiveness of a bonding of carbon fiber reinforced sheets to corroded steel members for the repair. Three types of surface treatment, what we call cleaning, of corroded plate are chosen as parameters. They are "without cleaning","removal of painting by brushing" and "complete removal of painting". From the experimental study, the following findings are obtained. 1) When the steel plate is subjected to tensile force, carbon fiber sheets adhered to the painted steel gives a higher strength against peeling compared to that of the plate without painting, 2) The grade of surface treatment, or cleaning of the corroded steel plate affects the strengthening effect.

A Study on Library Sign System: Focusing on the National Library of Korea (도서관 사인시스템에 관한 연구 - 국립중앙도서관 사례를 중심으로 -)

  • Choi, Man-Ho;Kim, Tae-Kyung;Kim, Bo-il
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.51 no.2
    • /
    • pp.73-93
    • /
    • 2017
  • The National Library of Korea installs and operates various signs for the purpose of efficient use of visitor and information transmission. In this study, the present status of the existing signatures of the National Library of Korea was surveyed and the satisfaction survey was conducted for the patron and staff. Based on this, we suggested the improvement of visual continuity (connectivity), changing the installation location, reduction of excess sign, limitations of temporary attachment signatures, and easy to understand contents as user's guide to efficient library use and improvement of National Central Library sign system.

Conversion of implant overdenture to an implant assisted removable partial denture in maxilla: case report (상악 임플란트 피개의치에서 임플란트 보조 국소의치로의 전환: 증례보고)

  • Seong-Soo Cho;Min-Gyu Song;Yoon-Hyuk Huh;Chan-Jin Park;Lee-Ra Cho;Kyung-Ho Ko
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.54-63
    • /
    • 2024
  • The long-term use of an implant overdenture shows problems, such as wear of attachment, concentrated occlusal forces on the anterior teeth, fracture of artificial teeth and rotation of denture. By transitioning to an Implant-assisted removable partial denture (IARPD) using additional implant placement, the problems can be solved. In this case report, a transition was made from implant overdenture to IARPD utilizing surveyed crowns to distribute occlusal forces concentrated on anterior teeth and to prevent denture rotation in a skeletal Class III patient. Design of definitive prosthesis with appropriate function and aesthetics was determined through several stages of provisional restorations. In this case, appropriate posterior occlusion and maintenance of peri-implant bone level of definitive prosthesis were observed.

Full mouth rehabilitation with dental implant utilizing 3D digital image and CAD/CAM system: case report (3차원 디지털 영상과 CAD/CAM 시스템을 활용한 전악 임플란트 수복 증례)

  • Kang, Se-Ha;Jeong, Seung-Mi;Shin, Jae-Ok;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.158-168
    • /
    • 2015
  • This article describes how to use digital system in a fully edentulous case that diagnosis to definitive prosthesis fabrication. While proceeding oral scan and CBCT taking, digital markers were attached on maxillary palate and lower existing denture. Using CBCT image and oral scan image, the bone contour and anatomical structures were analyzed and flapless surgical guide, customized abutment and prosthesis were made. After the osseointegration, the definitive prosthesis was fabricated using the oral scan image with scan body. It provides clinicians with a fast workflow and improves clinical efficiency.

Stress Variation Characteristics of Temporary Fixed Steel Rod in FCM Bridge Construction Method (FCM 교량 가설 공법에서 임시 고정 강봉의 응력 변화 특성 )

  • Hyun-Euk Kang;Wan-Shin Park;Young-Il Jang;Sun-Woo Kim;Hyun-Do Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.21-29
    • /
    • 2023
  • In this study, the stress characteristics of temporary fixed steel rods were analyzed in the "temporary fixing system using internal prestressing tension", which is mainly applied to the construction of superstructures by FCM. It was difficult to confirm the changes in initial tensile force in this system because the steel rod was internally connected to the pier and the PSC BOX. Therefore, measurement was performed before and after the completion of each segment using an FBG sensor to measure the change in the micro length of the steel rod. The results of the analysis showed that 75% to 90% of the maximum vertical contraction of the steel rod that occurred until the completion of the cantilever segment occurred in the fixing ~ 1segment, and the maximum loss of initial prestressing force was 39%. Such excessive loss of tension force to 1 segment means that tension is needed to improve the precision of construction during the fixation, and re-tension is needed to secure stability for conduction of cantilever segments after the completion of 1segment. In the 2 ~ last segment, the stress of the steel rod decreased gradually, and in the summer, the decrease in stress tended to partially recover due to the increase in the length of the steel rod corresponding to the increase in the vertical volume of PSC BOX. The dominant factor in the stress change in 2~ last segment in this phenomenon is judged to be the change in the length of the steel rod according to the temperature. Unlike the change in length, the relaxation was 1.2-2.7%, which was mostly offset by the opposite stress corresponding to the temperature stress. Therefore, a plan was proposed to improve the internal stress, such as adjusting the fixation time.

Finite Element Analysis of Transfer Length in Pretensioned Prestressed Concrete Members (프리텐션 PSC부재의 전달길이 해석 및 예측에 관한 연구)

  • Oh Byung-Hwan;Lim Si-Nae;Choi Young-Cheol
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.293-302
    • /
    • 2004
  • The transfer of prestress force in pretensioned prestressed concrete (PSC) members is of great concern because it affects directly the distribution of stress around the transfer zone. The design provision of current design code on the transfer length considers only the prestress intensity and the diameter of prestressing steels. However, other factors such as concrete compressive strength and concrete cover may affect greatly the transfer length. The purpose of the present paper is to explore the various factors that affect the transfer length in pretensioned PSC members. The bond stress-slip relation between prestressing steel and concrete was modeled first from experimental data and then this model was incorporated into the interface element. The interface element was used to perform the finite element analysis for pretensioned PSC members. The results indicate that the compressive strength and concrete cover are also very important parameters which affect the transfer length greatly. This means that the current design code, which considers only the effective prestress and diameter of prestressing steel, must be improved to take into account the other important variables of compressive strength and concrete cover. The present study allows more realistic analysis and design of pretensioned PSC members.

Characteristics of Resin on Antimicrobial Properties of Calibration Devices. (교정장치의 항균에 따른 레진상의 특성)

  • Jo, Jeong-Ki
    • Journal of Digital Convergence
    • /
    • v.18 no.4
    • /
    • pp.309-314
    • /
    • 2020
  • Polymethyl methacrylate (PMMA) is concerned with promoting oral infection due to its low antibacterial activity. To overcome this, the nanoparticles of Ag-MSN, nGO, and CNP were mixed with MMA liquid in a weight ratio of 0, 0.25, 0.5, 1.0, 2.0% compared to resin powder using Orthocryl from Dentarum, a calibration resin, and then instructed by the manufacturer. Accordingly, a specimen for calibration was prepared by mixing PMMA: MMA (1.2: 1) ratio, and physical properties of the calibration resin, antifungal experiments, and statistical analysis were performed. As a result of antibacterial experiments, the antibacterial properties of Ag-MSN increased. In nGO, the antibacterial adhesive effect increased hydrophilicity, not a change in surface roughness. The higher the CNP concentration, the higher the antibacterial activity. This suggests its potential usefulness as an antibacterial dental material for orthodontic devices and temporary restorations.

Implant prosthesis for fully edentulous patients using intra-oral scanning and abutment merging technique: A case report (무치악 환자에서 구강 스캔과 지대주 중첩을 이용한 임플란트 보철수복 증례)

  • Hwang, Chan-Hyeon;Jeong, Seung-Mi;Kim, Yong-Jun;Kim, Kyeong-Hee;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.61-70
    • /
    • 2017
  • In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.