• Title/Summary/Keyword: 임상통계

Search Result 2,274, Processing Time 0.04 seconds

Pain Recovery Pattern According to the Integrity after an Arthroscopic Rotator Cuff Repair (관절경하 회전근 개 봉합술 후 파열 정도에 따른 통증 회복 양상)

  • Kim, Ju-O;Sim, Sang-Don;Noh, Kyung-Hwan;Shon, Suk-June;Kim, Sul-Jun;Yang, Yun-Hyeok
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.155-160
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the pain recovery pattern according to the integrity and to analyze the factors affecting the progress and level of pain postoperatively. Materials and Methods: We examined 153 patients, who were treated with arthroscopic rotator cuff repair. 101 rotator cuff tears were full-thickness tear and 52 were partial tear. The mean follow up duration was 20 months (12~30 months). We evaluated the visual analogue scale, range of motion, ASES (American Shoulder and Elbow Surgeons), and UCLA (University of California at Los Angeles) scores preoperatively and postoperatively. We analyzed the pain recovery pattern between partial and full thickness tear using Student T-test and the factors affecting the progress and level of postoperative pain using multiple regression analysis. Results: The change patterns of visual analogue scale after arthroscpoic repair were similar regardless of the tear integrity. The VAS showed a continuous decreasing pattern, but increased at first 3 weeks postoperatively and at 7 weeks postoperatively, and then, decreased thereafter. The average VAS was ${\leqq}2$ points by postoperative 3 months. The factor affecting the pain score at 3 months was related to the preoperative limitation in forward flexion ($r^2=0.377$, p=0.021). Conclusion: There was no differences of the pain recovery pattern according to the integrity, and the factor affecting the progress of postoperative pain was preoperative angle of forward elevation. So, the appropriate preoperative rehabilitation protocol that can improve motions of the shoulder joint would help to improve the level of postoperative pain and functional recovery.

  • PDF

The Effect of Kimchi Pill Supplementation on Plasma Lipid Concentration in healthy people (김치 보충제가 건강한 성인의 혈중 지질농도에 미치는 여향)

  • 최선혜;김현주;권명자;백영호;송영옥
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.5
    • /
    • pp.913-920
    • /
    • 2001
  • The effect of kimchi pill supplementation on plasma lipid concentration of middle aged healthy people were studied. Freeze-dried mustard leaf added (30%) Korean cabbage kimchi and powdered glutinous parch were used to prepare kimchi and placebo pill, respectively. Experimental group if six participants took 3 g of freeze-dried kimchi as a pill daily for 6 weeks which is equivalent to 30 g of fresh kimchi and control group of six people took same amount of placebo. The diet intakes for the kimchi and placebo group fairly remained unchanged during 6 weeks of trial. When the effect of kimchi pill supplementation was expressed as average percentage changes based on each individual changes, the plasma triglyceride concentration of kimchi pill group was sig-nificantly decreased by 16.8% during trial (p<0.05)while that of placebo group increased by 9.8%, But no changes in plasma and LDL cholesterol concentrations of both groups were observed. HDL cholesterol of kimchi pill group significantly increased by 11.7%(p<0.05), therefore the ratio LDL/HDL cholesterol was significantly decreased by 6.7%(p<0.05) while that for the placebo group increased. The atherogenic index at the kimchi group was also significantly decreased by 10.8%(p<0.05). Kimchi supplementation seemed to have beneficial effects on controlling plasma triglyceride and HDL cholesterol in middle aged men.

  • PDF

Synthesis of Ultrasound Contrast Agent: Characteristics and Size Distribution Analysis (초음파 조영제의 합성 및 합성된 초음파 조영제의 특성 분석)

  • Lee, Hak Jong;Yoon, Tae Jong;Yoon, Young Il
    • Ultrasonography
    • /
    • v.32 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • Purpose: The purpose of this study is to establish the methodology regarding synthesis of ultrasound contrast agent imaging, and to evaluate the characteristics of the synthesized ultrasound contrast agents, including size or degradation interval and image quality. Materials and Methods: The ultrasound contrast agent, composed of liposome and SF6, was synthesized from the mixture solution of $21{\mu}mol$ DPPC (1, 2-Dihexadecanoyl-sn-glycero-3-phosphocholine, $C_{40}H_{80}NO_8P$), $9{\mu}mol$ cholesterol, $1.9{\mu}mol$ of DCP (Dihexadecylphosphate, $[CH_3(CH_2)_{15}O]_2P(O)OH$), and chloroform. After evaporation in a warm water bath and drying during a period of 12-24 hours, the contrast agent was synthesized by the sonication process by addition of buffer and SF6 gas. The size of the contrast agent was controlled by use of either extruder or sonication methods. After synthesis of contrast agents, analysis of the size distribution of the bubbles was performed using dynamic light scattering measurement methods. The degradation curve was also evaluated by changes in the number of contrast agents via light microscopy immediate, 12 hours, 24 hours, 36 hours, 48 hours, 60 hours, 72 hours, and 84 hours after synthesis. For evaluation of the role as an US contrast agent, the echogenicity of the synthesized microbubble was compared with commercially available microbubbles (SonoVue, Bracco, Milan, Italy) using a clinical ultrasound machine and phantom. Results: The contrast agents were synthesized successfully using an evaporation-drying-sonication method. The majority of bubbles showed a mean size of 154.2 nanometers, and they showed marked degradation 24 hours after synthesis. ANOVA test revealed a significant difference among SonoVue, synthesized contrast agent, and saline (p < 0.001). Although no significant difference was observed between SonoVue and the synthesized contrast agent, difference in echogenicity was observed between synthesized contrast agent and saline (p < 0.01). Conclusion: We could synthesize ultrasound contrast agents using an evaporation-drying-sonication method. On the basis of these results, many prospective types of research, such as anticancer drug delivery, gene delivery, including siRNA or microRNA, targeted molecular imaging, and targeted therapy can be performed.

Severity of Comorbidities among Suicidal Attempters Classified by the Forms of Psychiatric Follow-up (자살시도자의 정신건강의학과 치료 연계 형태에 따른 동반질병 심각도의 차이)

  • Lee, Hyeok;Oh, Seung-Taek;Kim, Min-Kyeong;Lee, Seon-Koo;Seok, Jeong-Ho;Choi, Won-Jung;Lee, Byung Ook
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.24 no.1
    • /
    • pp.74-82
    • /
    • 2016
  • Objectives : Suicide attempters have impaired decision making and are at high risk of reattempt. Therefore it is important to refer them to psychiatric treatment. Especially, People with medical comorbidity are at higher risk of suicidal attempt and mortality. The aim of this study was to investigate the characteristics of suicidal attempters and to analyze the influence of the medical comorbidity on decision to receive psychiatric treatment after visit to an emergency department. Methods : One hundred and thirty two patients, who visited the emergency room of a general hospital in Gyeonggi-do between January, 2012 and December, 2012 were enrolled as the subjects of this study. After reviewing each subject's medical records retrospectively, demographic and clinical factors were analyzed. Results : Regardless of the engagement type, either via admission or outpatient clinic, the determinant factors of psychiatric treatment engagement were psychiatric diagnosis, employment status, previous psychiatric treatment history, and previous attempt history. Comparison of severity of medical comorbidity(Charlson Comorbidity Index) showed that suicide attempters who received psychiatric treatment via admission or refused the treatment tended to have higher level of medical comorbidity than who received psychiatric treatment via outpatient department. Conclusions : Our findings showed that medical comorbidity of suicide attempters affected the decision to accept psychiatric treatment. All psychiatrists should evaluate the presence and the severity of medical comorbidity of the suicide attempters and consider implementing more intervention for the medically ill attempters who are willing to discharge against advice.

A Study on the Necessity Verification of Convex Probe Disinfection (Convex Probe 소독 필요성 검증에 관한 연구)

  • Choi, Kwan-Yong;Yoo, Se-jong;Lee, Jun-ho;Hong, Sung-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.193-200
    • /
    • 2019
  • The study was conducted surveying ultrasound room workers on hospital infection awareness in Daejeon and Choong-chunng region. The contamination of ultrasonic probes used in clinical trials was measured using ATP, and the results were verified after using 70% alcohol sterilization. It was measured on the group's general characteristics and the specific categories such as academic background, job type, having professional certificate and infection education. After the examination, the gel removal and method, disinfection status of the probe and variable correlation analysis were performed to analyze the recognition of the ultrasonic probe disinfection. After examination in ultrasound room, it was found that towels were used the most for cleaning, and the gel container was not replaced for more than three months. After 70% alcohol disinfection, ATP contamination was reduced from $1055.4{\pm}944.2$ to $133.5{\pm}93.2$ and the result was analyzed to be statistically significant.(${\rho}<0.01$) The found bacteria were CNS, Gram positive bacillus, and Micrococcus specs. In order to solve this problem, 70% alcohol sterilization was applied and the bacteria were not detected after the treatment. The research shows that regular training on infection control and efforts to prevent infection are necessary, and that 70% alcohol is effective in disinfect the bacteria. Therefore, the medical institution should provide active hospital infection control education to improve the awareness of hospital infection among workers and contribute to the prevention of patient infection. It is also understood that proper use of the results of this study will help prevent infection by means of ultrasonic probes.

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

Long-Term Trend Analysis in Nuclear Medicine Examinations (핵의학 영상 검사의 중장기 추세 분석 - 서울 소재 일개 상급 종합병원을 중심으로 -)

  • Jung, Woo-Young;Shim, Dong-Oh;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.15-28
    • /
    • 2019
  • Purpose Nuclear medicine was initially introduced in Korea in 1969 and widely applied to treat hyperthyroidism with $^{131}I$. Also, gamma camera was adopted in 1969 in the first place and its application has been growing continually in many ways. We analyzed long-term trend in nuclear medicine examinations for the last 2 decades. The purpose of this paper is to make predictions and to set both plans and directions on the development of nuclear medicine. Materials and Methods We analyzed the performance of nuclear medicine examinations and therapies performed in Asan Medical Center from 1998 to 2017. Results Results from the last 20 years regarding Bone scan, Renal scan, MUGA scan and $^{18}F$-FPCIT, Bone Mineral Density were on a increase. And Myocardium perfusion SPECT, Thyroid scan, Lung scan were on a decrease while $^{18}F-FDG$ PET maintained on a steady course. Until 2010 there was a positive performance with the therapy but after the excessive medical care in thyroid examination performance is at status quo. Key events such as a medical strike(2000), Middle-East Respiratory Syndrome (2015) influenced the overall performance of the therapy. Conclusion In order to promote a long-term growth in nuclear medicine examination and therapy, it is inevitable to respond to the changes in current medical environment. Furthermore, it is strongly suggested to put efforts to maintain and develop new examinations and clinical indicators.

Comparison of Thyroid Doses for Shielding Material Changes in Neck Computed Tomography (Neck CT에서 차폐체 재료 변화에 따른 Thyroid 선량 비교 연구)

  • Kang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.65-71
    • /
    • 2019
  • With regard to current Neck CT, Bismuth shielding boards are often being used to reduce exposure to superficial organs such as the thyroid. However, beam hardening often occurs near superficial organs with Bismuth shielding boards and variations in CT Number, Noise, and Uniformity values occur severely. This study looked into the usefulness of shielding boards made from aluminum and silicone that can be easily obtained and have good machinability by comparing them to the existing Bismuth shielding board. An Aluminum 7.3mm and a Silicone 21.5mm were made with shielding ratios similar to that of the Bismuth(0.06 mmPb). TLD (TLD-100) was placed on the thyroid area of the Phantom (RS-108T) and 5 doses were measured for each. To compare image quality, CT Number and Noise variations in axial images of the thyroid area in Neck CT images were compared. Also, variations in CT Number, Noise, and Uniformity were measured in the AAPM phantom images and compared. In the results, when thyroid doses for each shielding board were compared, the Bismuth shielding board showed a 14% reduction, the Silicone 21.5mm showed a 15% reduction, and the Aluminum 7.3mm showed a 13% reduction compared to the Non-Shield. Statistically, there were no significant differences in comparison with the Bismuth shielding board. In CT Number variations of thyroid area images, variations were largest for the Bismuth shielding board. With Uniformity evaluations of the AAPM phantom, the Bismuth shielding board was found unsuitable and the Aluminum 7.3mm and Silicone 21.5mm satisfied the acceptance criteria. Research results show that the Aluminum 7.3mm and Silicone 21.5mm have a similar shielding ratio to the high-priced Bismuth shielding board that is currently being used clinically and in comparison tests of CT Number attenuation coefficient variations, Noise, and Uniformity which are phantom image evaluation items, they proved to be better than Bismuth shielding boards. If various shielding boards are made using aluminum and silicone, sized appropriately for superficial organs, it would be useful in decreasing patient doses.

Correlation between fish consumption and the risk of mild cognitive impairment in the elderly living in rural areas (농촌지역에 거주하는 노인의 생선 섭취량과 인지기능저하 위험도 간의 상관성)

  • Yu, Areum;Kim, Jihye;Choi, Bo Youl;Kim, Mi Kyung;Yang, Yoonkyoung;Yang, Yoon Jung
    • Journal of Nutrition and Health
    • /
    • v.54 no.2
    • /
    • pp.139-151
    • /
    • 2021
  • Purpose: This study examines the correlation between fish consumption and the risk of mild cognitive impairment in the elderly living in rural areas. Methods: The Yangpyeong cohort data collected from Yangpyeong in July 2009 and August 2010 was used as the data set. Adults greater than or equal to 60 years who have completed the Korean version of the Mini-Mental State Examination (MMSE-KC) were selected for the study. After excluding participants with less than 500 kcal of energy intake (n = 2), a total of 806 adults were enrolled as the final subjects. Cognitive function was assessed using the MMSE-KC, and dietary intake was collected using the quantitative food frequency questionnaire comprising 106 foods or food groups. Results: The educational level, proportion of people who exercise, fruits and vegetable intake, and energy intake, tended to increase with fish intake among men, while increasing age resulted in decreased fish consumption. Among women, the educational level, proportion of subjects who exercise, proportion of subjects currently taking dietary supplements, fruits and vegetable intake, and energy intake, tended to increase with fish consumption, whereas increasing age showed decreasing fish consumption. Increased fish intake resulted in a higher MMSE-KC score after adjusting for the confounding variables in women (p for trend = 0.016), but no significant trend was observed between fish intake and MMSE-KC score in men. Fish intake was inversely related to the risk of mild cognitive impairment after adjusting for covariates in women (Q1 vs. Q4; odds ratio, 0.46 [0.23-0.90]; p for trend = 0.009). Conclusion: This study determined that increased fish consumption is correlated with reduced risk of mild cognitive impairment in the female elderly. Further longitudinal studies with larger samples are required to determine a causal relationship between fish intake and cognitive function.

Marginal and internal fit of interim crowns fabricated with 3D printing and milling method (3D 프린팅 및 밀링 방법으로 제작된 임시 보철물 적합도 비교 분석)

  • Son, Young-Tak;Son, KeunBaDa;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.254-261
    • /
    • 2020
  • Purpose: The purpose of this study was to assess the marginal and internal fit of interim crowns fabricated by two different manufacturing method (subtractive manufacturing technology and additive manufacturing technology). Materials and Methods: Forty study models were fabricated with plasters by making an impression of a master model of the maxillary right first molar for ceramic crown. On each study model, interim crowns (n = 40) were fabricated using three types of 3D printers (Meg-printer 2; Megagen, Zenith U; Dentis, and Zenith D; Dentis) and one type milling machine (imes-icore 450i; imes-icore GmbH). The internal of the interim crowns were filled with silicon and fitted to the study model. Internal scan data was obtained using an intraoral scanner. The fit of interim crowns were evaluated in the margin, absolute margin, axial, cusp, and occlusal area by using the superimposition of 3D scan data (Geomagic control X; 3D Systems). The Kruskal-wallis test, Mann-Whitney U test and Bonferroni correction method were used to compare the results among groups (α = 0.05). Results: There was no significant difference in the absolute marginal discrepancy of the temporary crown manufactured by three 3D printers and one milling machine (P = 0.812). There was a significant difference between the milling machine and the 3D printer in the axial and occlusal area (P < 0.001). The temporary crown with the milling machine showed smaller axial gap and higher occlusal gap than 3D printer. Conclusion: Since the marginal fit of the temporary crown produced by three types of 3D printers were all with in clinically acceptable range (< 120 ㎛), it can be sufficiently used for the fabrication of the temporary crown.