• Title/Summary/Keyword: 임상적 성과

Search Result 8,106, Processing Time 0.04 seconds

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

On the Study of Forest Sampling Methods in Natural Deciduous Forest (활엽수림(闊葉樹林)에 대(對)한 자원조사법(資源調査法)의 연구(硏究))

  • Kim, Kap Duk
    • Journal of Korean Society of Forest Science
    • /
    • v.17 no.1
    • /
    • pp.35-42
    • /
    • 1973
  • Deciduous trees grown naturally in the forest of Korea usually have an irregular Lee-form and their utility has been decreased. In Korea, most of the deciduous stands are distributed in the hinterland. A shortage of the total growing stock made utilization of them necessary in this country even though some difficulties to be cutted and transported are accompanied. Therefore, this study was conducted to select the suitable sampling method for surveying them. The results investigated are as follows. 1. Three locations being 10 hectares in each location for the plots were chosen and surveyed with six $20m{\times}50m$ rectangular sample plots by four types of sampling method below. And the result is shown in Table 1. A. Random sampling by grids B. Random sampling by co-ordinates C. Systematic line plot. D. Sub-sampling 2. One hundred and fifty hectares from all plots were sectioned through the application of aerial photography scaled of 1 : 15,000. The author divided forest types according to diameter class and crown density with mirror stereoscope. The forest types were divided into three classes. Seven sample plots from the area of 150 hectars are systematically arranged and the results investigated on the circular sample point of 0.1 hectare are shown in Table 4. 3. There were no significant differences between results by sampling method and by diameter measurement method (population mean) as shown in Table 3. 4. Random sampling by grid and systematic line plot are better than others. 5. There are more over-estimated values when the circular sample point is used than where the rectangular sample point. 6. As forest stands are irregular, smaller number of sample points will make many errors.

  • PDF

Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System (GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구)

  • Lee, Chung-Il;Shin, Jae-Won;Shin, Hun-Joo;Jung, Jae-Yong;Kim, Yon-Lae;Min, Jeong-Hwan;Hong, Seung-Woo;Chung, Su-Mi;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Cyberknife with small field size is more difficult and complex for dosimetry compared with conventional radiotherapy due to electronic disequilibrium, steep dose gradients and spectrum change of photons and electrons. The purpose of this study demonstrate the usefulness of Geant4 as verification tool of measurement dose for delivering accurate dose by comparing measurement data using the diode detector with results by Geant4 simulation. The development of Monte Carlo Model for Cyberknife was done through the two-step process. In the first step, the treatment head was simulated and Bremsstrahlung spectrum was calculated. Secondly, percent depth dose (PDD) was calculated for six cones with different size, i.e., 5 mm, 10 mm, 20 mm, 30 mm, 50 mm and 60 mm in the model of water phantom. The relative output factor was calculated about 12 fields from 5 mm to 60 mm and then it compared with measurement data by the diode detector. The beam profiles and depth profiles were calculated about different six cones and about each depth of 1.5 cm, 10 cm and 20 cm, respectively. The results about PDD were shown the error the less than 2% which means acceptable in clinical setting. For comparison of relative output factors, the difference was less than 3% in the cones lager than 7.5 mm. However, there was the difference of 6.91% in the 5 mm cone. Although beam profiles were shown the difference less than 2% in the cones larger than 20 mm, there was the error less than 3.5% in the cones smaller than 20 mm. From results, we could demonstrate the usefulness of Geant4 as dose verification tool.

Comparison of Direct-labeling Method of Antibody with $^{99m}Tc$ and $^{188}Re$ (농양이식백서에서 $^{99m}Tc,\;^{188}Re$ 직접표지항체의 비교)

  • Choi, Tae-Hyun;Lim, Sang-Moo;Choi, Chang-Woon;Woo, Kwang-Sun;Chung, Wee-Sup;Lim, Soo-Jeong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.84-93
    • /
    • 1999
  • Purpose: We investigated the direct labeling method of antibody with $^{99m}Tc$ and $^{188}Re$ and examined the stability and function of these labeled compounds in in vitro and in vivo. Materials and Methods: Disulfide bond of nonspecific human IgG was reduced to -SH group by 2-mercaptoethanol. Stannous ion was used to reduce $^{99m}Tc$ and $^{188}Re$. The stability of $^{99m}Tc$-IgG and $^{188}Re$-IgG was estimated upto 24 hrs. Biodistribution was evaluated in abscess bearing rats at 4 and 24 hr post-injection of $^{99m}Tc$ or $^{188}Re$ labeled IgG. Results: The number of -SH group per reduced IgG molecule was 2.34. The labeling yield of $^{99m}Tc$-IgG and $^{188}Re$-IgG were 90% and 95%, respectively The stability of $^{99m}Tc$-IgG at 1, 4, 6 and 24 hr was 91%, 83%, 78%, 7% and that of $^{188}Re$-IgG at 1, 4, 16 and 24 hr was 94%, 80%, 47%, 42%, respectively. At 4 hr post-injection of $^{99m}Tc$-IgG, high uptake was found on kidney, blood, stomach and abscess ($9.42{\pm}0.68,\;1.43{\pm}0.24,\;0.86{\pm}0.18,\;0.72{\pm}0.10$ %ID/g, respectively). The uptakes at 24 hr were kidney, abscess,.itomach, and blood in descending order. In case of $^{188}Re$-lgG, high uptake at 4 hr post injection appeared on kidney, blood, abscess and stomach ($3.92{\pm}0.62,\;1.32{\pm}0.08,\;0.88{\pm}0.01,\;0.26{\pm}0.06$, respectively). The uptakes at 24 hr were kidney, abscess, blood and stomach in descending order. The abscess to blood uptake ratio of $^{99m}Tc$-IgG was 0.5 at 4 hr and 2.02 at 24 hr and that of $^{188}Re$-IgG was 0.67 and 1.29. Conclusion: $^{99m}Tc$-IgG and $^{188}Re$-IgG canbe labeled efficiently with direct labeling method. However, $^{99m}Tc$-IgG and $^{188}Re$-IgG, labeled with direct method, was unstable. Further study is needed to enhance the stability of the antibody labeling.

  • PDF

Dosimetric Characteristics on Penumbra Regions of the Multileaf Collimator as Compared with the Lead Alloy Block (다엽 콜리메이터(Multileaf Collimator)와 합금납 차폐물(Lead Alloy Block)의 반 그림자영역의 선량 분포상의 특성 비교)

  • Lee Sang Wook;Oh Young Tack;Kim Woo Cheol;Keum Ki Chang;Yoon Seong Ick;Kim Hyun Soo;Park Won;Chu Seong Sil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.391-396
    • /
    • 1995
  • Purpose : The Conformal Radiation Therapy has bee widely used under favour of development of computer technologies. The delivery of a large number of static radiation fields are being necessary for the conformal irradiation. In this paper we investigate dosimetric characteristics on penumbra regions of a multileaf collimator(MLC), and compare to those of lead alloy block for the optimal use of the system in 3-D conformal radiotherapy. Materials and Methods : The measurement of penumbra by MLC or lead alloy block was performed with 6 or 10 MV X-rays. The film was positioned at a dmax depth and 10 cm depth, and its optical density was determined using a scanning videodensitometer. The effective penumbra, the distance from $80{\%}$ to $20{\%}$ isodose lines and $90{\%}$ to $10{\%}$ were analyzed as a function of the angle between the direction of leaf motion and the edge defined by leaves. Results : Increasing MLC angle ($0-75^{\circ}$) was observed with increasing the penumbra widths and the scalloping effect. There was no definite differences of penumbra width from $80{\%}$ to $20{\%}$ isodose lines, while being the small increase of penumbra width from $90{\%}$ to $10{\%}$ isodose line varing the depth and energy. The effective penumbra width of lead alloy block are agree resonably with those of MLC within 4.8mm. Conclusion : The comparative qualitative study of the penumbra between MLC and lead alloy block demonstrate the clinical acceptability and suitability of the multileaf collimator for 3-D conformal radiotherapy.

  • PDF

Analysis of Surgical Results for the Patients with Pulmonary Metastasis from Colorectal Carcinoma (대장암의 전이성 폐암의 수술 결과에 대한 분석)

  • Sim, Hyung-Tae;Kim, Yong-Hee;Shin, Hong-Ju;Chun, Mi-Sun;Bae, Chi-Hoon;Lee, Eung-Sirk;Park, Seung-Il;Kim, Dong-Kwan
    • Journal of Chest Surgery
    • /
    • v.39 no.11 s.268
    • /
    • pp.838-843
    • /
    • 2006
  • Background: The lung is the most common site of metastatic colorectal cancer comprising 10% of all curative resection of colorectal cancer. The reported 5 year survival rate varies among institutions. The purpose of the present study was to present the retrospective analysis of colorectal metastatic lung cancer surgery at our institution. Material and Method: A total of 61 patients undergoing surgery for metastatic colorectal lung cancer between July 1996 and December 2003 were included in the present study. The stage of the primary colorectal cancer, site of pulmonary metastasis, method of lung resection, the number and size of the metastatic nodules, the recurrence rate, and survival were assessed. Result: The 3 and 5 year survival rates were 66% and 41%, respectively. No significant risk factors were identified among the studied variables by either univariate or multivariate analysis. The mean disease free survival rate was 17 months. The most common recurrent site was lung, and among these patients, 3 underwent a second operation and two are still alive. Conclusion: The results of the above data suggest that pulmonary resection of metastatic lung cancer in select patients after curative resection of colon cancer may be a good therapeutic option with the potential for excellent results.

$^{18}F$-FDG PET/CT in Patients with Initially Diagnosed Adenoid Cystic Carcinoma of the Head and Neck: Clinicoplathologic Correlation (처음 진단된 두경부 선양낭성암종에서 $^{18}F$-FDG PET/CT: 임상상 및 병리소견과의 상관성)

  • Lee, Ji-Young;Choi, Joon-Young;Ko, Young-Hyeh;Baek, Chung-Hwan;Son, Young-Ik;Cho, Suk-Kyong;Cheon, Mi-Ju;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.395-401
    • /
    • 2009
  • Purpose: We evaluated $^{18}F$-FDG PET/CT findings in initially diagnosed adenoid cystic carcinoma (ACC) of the head and neck in association with pathological subtype, staging, uptake comparison with squamous cell carcinoma (SqCC) and prognosis. Materials and Methods: The subjects were 16 patients with initially diagnosed ACC of head and neck who underwent pretreatment $^{18}F$-FDG PET/CT. Histological subtype (solid pattern vs. tubular/cribriform pattern), $SUV_{max}$ of size-matched SqCC of the head and neck as control group, disease-free survival (DFS) were compared with the $SUV_{max}$ of ACC of the head and neck. Results: Of total 16 patients, 6 had solid pattern and the remaining 10 had tubular/cribriform pattern. The $SUV_{max}$ were significantly higher in solid pattern group than in tubular/cribriform pattern group ($6.7{\pm}3.2$ vs. $4.2{\pm}0.9$, p=0.03). PET/CT found unexpected distant metastasis in 18.7% of patients (3/16) and changed the therapeutic plan in those patients. The $SUV_{max}$ of ACC was significantly lower than that of size-matched SqCC ($5.1{\pm}2.4$ vs. $13.6{\pm}6.0$, p<0.001). DFS was not significantly different according to the histological subtype. In contrast, patients with high $^{18}F$-FDG uptake ($SUV_{max}$ ${\geq}$6.0) had significantly shorter DFS than those with low $^{18}F$-FDG uptake ($SUV_{max}$ <6.0). Conclusion: $^{18}F$-FDG uptake of ACC of the head and neck is significantly associated with histological subtype and DFS. $^{18}F$-FDG PET/CT may be useful for detecting unexpected metastasis. Since $^{18}F$-FDG uptake of tubular/cribriform ACC compared with SqCC is relatively low, it is necessary to interpret PET images carefully in patients without alleged ACC.

The Effect of Surface Defects on the Cyclic Fatigue Fracture of HEROShaper Ni-Ti rotary files in a Dynamic Model: A Fractographic Analysis (Fractographic 분석을 통한 HEROShaper 니켈티타늄 전동 파일의 피로파절에 미치는 표면결함의 역할)

  • Lee, Jung-Kyu;Kim, Eui-Sung;Kang, Myoung-Whai;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.130-137
    • /
    • 2007
  • This in vitro study examined the effect of surface defects on cutting blades on the extent of the cyclic fatigue fracture of HEROShaper Ni-Ti rotary files using fractographic analysis of the fractured surfaces. A total of 45 HEROShaper (MicroMega) Ni-Ti rotary flies with a #30/.04 taper were divided into three groups of 15 each. Group 1 contained new HEROShapers without any surface defects. Group 2 contained HEROShapers with manufacturing defects such as metal rollover and machining marks. Croup 3 contained HEROShapers that had been clinically used for the canal preparation of 4-6 molars A fatigue-testing device was designed to allow cyclic tension and compressive stress on the tip of the instrument whilst maintaining similar conditions to those experienced in a clinic. The level of fatigue fracture time was measured using a computer connected the system. Statistical analysis was performed using a Tukey's test. Scanning electron microscopy (SEM) was used for fractographic analysis of the fractured surfaces. The fatigue fracture time between groups 1 and 2, and between groups 1 and 3 was significantly different (p<0.05) but there was no significant difference between groups 2 and 3 (p>0.05). A low magnification SEM views show brittle fracture as the main initial failure mode At higher magnification, the brittle fracture region showed clusters of fatigue striations and a large number of secondary cracks. These fractures typically led to a central region of catastrophic ductile failure. Qualitatively, the ductile fracture region was characterized by the formation of microvoids and dimpling. The fractured surfaces of the HEROShapers in groups 2 and 3 were always associated with pre-existing surface defects. Typically, the fractured surface in the brittle fracture region showed evidence of cleavage (transgranular) facets across the grains, as well as intergranular facets along the grain boundaries. These results show that surface defects on cutting blades of Ni-Ti rotary files might be the preferred sites for the origin of fatigue fracture under experimental conditions. Furthermore this work demonstrates the utility of fractography in evaluating the failure of Ni-Ti rotary flies.

Change of FDG Uptake According to Radiation Dose on Squamous Cell Carcinoma of the Head and Neck (두경부종양에서 방사선조사량에 타른 FDG-PET의 변화양상)

  • Lee Sang-wook;Kim Jae-Seung;Im Ki Chun;Ryu Jin Sook;Lee Hee Kwan;Kim Jong Hoon;Ahn Seung Do;Shin Seong Soo;Yoon Sang Min;Song Siyeol;Park Jin-hong;Moon Dae Hyuk;Choi Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.98-105
    • /
    • 2004
  • Purpose : To evaluate whether positron omission tomography (PET) with 2-[F-18]fluoro-2-deoxy-D-giucose(FDG) can be used to predict of early response to definitive aim radlotherapy (RT) in squamous cell carcinoma of the head and neck using response rate and locoreglonal control as study endpoints. Materials and Methods : Twenty-two patients with head and neck cancer underwent a FDG-PET study before RT, after a flrst dose of 45 Gy, and after a second dose on more 4han 70 Gy. Standard uptake value (SUV) was calculated for primary tumor (n=22) and neck lymph node (n:10). Attenuation corrected PET scans acquired 60 min after tracer injection were used for evaluation of FDG uptake In tumors. A quantitative FDG uptake index was expressed as Suvlean (corrected for iean body mass). The follow-up time was at least 5 months (range S-1 S months). Results : A total of 22 primary tumors and 10 metastatic lymph nodes were analyzed In FDG-PET. In the first PET study the mean SUVlean the primary tumors and nodes were 5.4 (SD, 2.5) and 4.6 (SD, 2.3), respectively. In the second PET, study peformed after 46 Gy RT the mean SUV in primary tumor and node decreased to 2.9 (SD, 1.9, p<0.001) and 1.7 (SD, 1.3) respectively. in the third PET study peformed at the full dose (more than 70 Gy), RT the mean SUV In the primary tumors and nodes decreased to 2.3 (SD, 1.5, p<0.001) and 1.5 (SD, 1 .1) respectively. Conclusions: FDG uptake In tumors showed a significant decrease after the 45 Gy and more than 70 Gy of RT for squamous cell carcinoma of the head and neck. Reduction of metabolic activity after 46 Gy of radiotherapy Is closely correlated with radiation response.

MMP-2, MMP-8 Expression in gingival tissue of Chronic Periodontitis associated to Type 2 Diabetes Mellitus (2형 당뇨병을 동반한 만성 치주염 환자의 치은조직에서 MMP-2, MMP-8의 발현 양상 비교)

  • Kang, Min-Gu;Cha, Hyun-Jeong;Song, Sun-Hee;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.661-674
    • /
    • 2005
  • The purpose of this study was to quantify and compare the level of MMP-2, MMP-8 in the healthy, inflammed gingival tissue and inflammed gingival tissue associated with type 2 DM. We investigate whether expression of MMP-2, MMP-8 is increased by chronic periodontitis associated with type 2 DM. Gingival tissue samples were obtained during periodontal surgery or tooth extraction. Based on patient's systemic condition & clinical criteria of gingiva, each gingival samples were divided into three groups. Group l(n=8) is clinically healthy gingiva without bleeding and no evidence of bone resorption or periodontal pockets, obtained from 8 systemically healthy patients. Group 2(n=8) is inflammed gingiva from patients with chronic periodontitis. Group 3(n=8) is inflammed gingiva from type 2 diabetic patients with chronic periodontitis. Tissue samples were prepared and analyzed by Western blotting. The quantification of MMP-2, MMP-8 was performed using a densitometer and statistically analyzed by ANOVA. MMP-2, MMP-8 was expressed in all samples including healthy gingiva and increased in group 3 compared to group 1 and 2, and showed that significant variation was observed between group 1 & 3 in MMP-8 results. In conclusion, this study demonstrated that human gingival tissue with chronic periodontitis associated to type 2 diabetes showed slightly elevated MMP-2, MMP-8 levels compared to healthy gingiva and non-diabetic inflamed gingiva.