• Title/Summary/Keyword: 임상실험

Search Result 2,400, Processing Time 0.026 seconds

Group sequential testing methods for comparing cure rates (임상시험에서 치료율 비교를 위한 집단축차검정법에 관한 고찰)

  • 박경미;이재원
    • The Korean Journal of Applied Statistics
    • /
    • v.9 no.2
    • /
    • pp.95-108
    • /
    • 1996
  • There are many clinical trials where a large portion of the patients are cured of disease. In such a case, one might be more interested in testing the differences in cure rates rather than other types of differences in failure distribution. For ethical and economic reasons, clinical trials must be repeatedly monitored for evidence of treatment benefit or harm. In this article, we examined by simulation the properties of nonparametric group sequential methods for comparing the cure rates between two treatment groups during the trial in a wide range of alternatives, censoring rates and cure rates.

  • PDF

Comparison of binary data imputation methods in clinical trials (임상시험에서 이분형 결측치 처리방법의 비교연구)

  • An, Koosung;Kim, Dongjae
    • The Korean Journal of Applied Statistics
    • /
    • v.29 no.3
    • /
    • pp.539-547
    • /
    • 2016
  • We discussed how to handle missing binary data clinical trials. Patterns of occurring missing data are discussed and introduce missing binary data imputation methods that include the modified method. A simulation is performed by modifying actual data for each method. The condition of this simulation is controlled by a response rate and a missing value rate. We list the simulation results for each method and discussed them at the end of this paper.

Optimization of Flip Angle at Head & Neck MR Angiography using Gadoteridol (Gadoteridol을 이용한 Head & Neck MR Angiography에서의 적정 Flip Angle)

  • Jeong, Hyunkeun;Kim, Mingi;Song, Jaejun;Nam, Kichang;Choi, Hyunsung;Jeong, Hyundo;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.3
    • /
    • pp.151-159
    • /
    • 2016
  • In this research, we tried to suggest moderate FA(Flip Angle) for CE(Contrast Enhnaced)-Head&Neck MR Angiography with Gadoteridol. For this study, we did test MR phantom and clinical study according to FA change. After that, quantitative analysis was progressed. The results of MR phantom study were as follow: RSP(Reaction Starting Point)was recorded within 300~400 mmol. MPSI(Max Peak Signal Intensity) was 2,086, 3,705, 5,109, 6,194, 7.096, 7,192 [a.u]. MPP(Max Peak Point) was shown at 30, 50, 50, 40, 50, 40 mmol. IRMPSI(Increase Rate of MPSI) was 77.6%, 37.9%, 21.2%, 14.6%, 1.4% as increasing of FA. The results of clinical study were as follow SICB(Signal Intensity of Carotid artery Bifurcation) was recorded respectively 392.5, 4165.2, 4270, 3502.2, 3263.7, 3119.6 [a.u]. ORA(Occurence Rate of Artifact) was increased as 0, 0, 20, 40, 50, 70%. According to this research, we are not only able to assure that increase of FA can be effect on H1 spin's SI(Signal Intensity) which was combined with gadolinium agent, but also be effect on artifact rate in blood vessel. In clinical field, we expect that CE-Head&Neck MR Angiography can be performed in a practical way with this research.

연구실 탐방 - SK케미칼 생명과학연구실

  • Korean Federation of Science and Technology Societies
    • The Science & Technology
    • /
    • v.32 no.10 s.365
    • /
    • pp.30-31
    • /
    • 1999
  • SK케미칼 생명과학연구실은 9년동안의 연구 끝에 국내 최초로 백금착체 항암제인 '선플라'를 개발해 지난 7월 식품의약품안전청으로부터 발매 허가를 받았다. 81억원의 연구비를 투자하여 선플라를 개발한 이 연구실은 앞으로 1백억원 이상을 더 투자하여 임상실험을 계속키로 했으며 이미 30여국에 특허를 출원하여 22개국에서 특허를 완료했다.

  • PDF

이달의 과학자 - 가톨릭대 의대 산부인과 교수 김진우 박사

  • Korean Federation of Science and Technology Societies
    • The Science & Technology
    • /
    • v.29 no.11 s.330
    • /
    • pp.80-81
    • /
    • 1996
  • 우리나라 여성들에게서 발병 사망률이 높은 자궁경부암의 세포주를 배양하여 암의 발생원인 특성을 밝혀낸 가톨릭대 의대 김진우교수. 김교수는 난소암 자궁내막암 세포배양에도 성공하여 앞으로 임상실험을 하기 위한 재료확보와 암의 항원 전체구조를 파악하는 연구를 계속할 것이라고 한다.

  • PDF

Balance plate system to monitor and analysis the center of pressure(COP) of the body (인체 압력중심 계측과 분석을 위한 평형판 시스템의 개발)

  • Cha, Eun-Jong;Song, Chun-Hee;Lee, Tae-Soo;Lee, Kyung-Moo;Kim, Nam-Kyun;Kim, Yeon-Hee
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.63-67
    • /
    • 1995
  • 신체 자세균형의 안정도를 반영하는 압력중심(COP)을 계측하기 위해 정삼각형 모양의 평형판 시스템을 설계, 제작하였고 그 유용성을 평가하였다. 재질로는 강도와 가공성이 뛰어난 듀랄루민을 사용하였고 압력중심(COP)의 위치를 계측하는 힘센 서로는 공업용 로드셀 3개를 사용하였다. COP신호를 검출하는 전자회로를 제작하여 실험한 결과 평형판의 COP 위치측정 오차는 2% 미만이었다. 시스템의 임상응용가능성을 평가하기 위하여 정상인 10명과 이학적 평가가 정상인 환자 4명을 대상으로 임상실험을 수행하였다. 자세안정도를 반영할 척도로써 COP신호의 표준편차($SD_x,\;SD_y,\;SD_r$)를 설정하여 자세가 불안정해짐에 따라, 그리고 시각의 영향이 배제됨에 따라 이 값들이 증가하는 것을 관찰하였다. 또한 환자의 경우에는 정상인과 현저한 차이를 보였다. 즉, 본 평형판시스템이 자세안정도를 정량적이고 예민하게 계측할 수 있음을 확인하였고 임상적 실용성을 검증하였다.

  • PDF