• Title/Summary/Keyword: 임상실험

Search Result 2,410, Processing Time 0.026 seconds

The Changes of Serum Level of Tumor Necrosis Factor-Alpha, Gamma-Interferon and Soluble-Intercellular Adhesion Molecule-1 Relating to the Progression and Treatment of Patients with Pulmonary Tuberculosis (폐결핵의 진행정도 및 치료에 따른 혈청내 Tumor Necrosis Factor-Alpha, Gamma-Interferon 및 Soluble-Intercellular Adhesion Molecule-1의 변화)

  • Kim, Myung-Hoon;Ahn, Joong-Hyun;Moon, Hwa-Sik;Park, Sung-Hak;Song, Jeong-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.6
    • /
    • pp.1167-1177
    • /
    • 1998
  • Background : Pulmonary tuberculosis is one of the diseases characterized granuloma formation which was controlled by cellular immune reactions. In the process of granulomatous changes, activated alveolar macrophages and T lymphocytes secrete many cytokines including interleukin-1 (IL-1), tumor necrosis factor-alpha(TNF-$\alpha$), interferon-gamma(IFN-$\gamma$) which mediate inflammatory reactions. Intercelluar adhesion molecule-1(ICAM-1) also known to major role player in inflammatory processes, and increased cellular expressions when endothelial cell was stimulated by IL-1, TNF and IFN. Method : To evaluate relationships among cellular immune reactions and clinical stages, pulmonary tuberculosis patients were classified into three groups according to their clinical stages including minimal, moderate and far advanced tuberculosis. TNF-$\alpha$ IFN-$\gamma$, sICAM-1 (soluble form of ICAM-1) were measured at the time of diagnosis and after 6-months anti-tuberculosis medications by radioimmuno assay or enzyme linked immunosolvent assay. Result : TNF-$\alpha$, IFN-$\gamma$, sICAM-1 were significantly increased in moderate and far advanced pulmonary tuberculosis patients but no meaningful changes in minimal staged patients. 6-months anti-tuberculosis medications reduced serum sICAM-1 levels significantly, related to clinical improvement but no significant changes were found in the serum levels of TNF-$\alpha$ and IFN-$\gamma$. In the point of correlations. positive ones revealed between TNF-$\alpha$ and sICAM-1, also between IFN-$\gamma$ and sICAM-1 but no correlation between TNF-$\alpha$ and IFN-$\gamma$. Conclusion : Measurement of serum sICAM-1 could be useful parameter to evaluate the severity of pulmonary tuberculosis and to monitor disease activities during anti-tuberculosis medications.

  • PDF

Early Bronchoconstriction After Allergen Challenge of Nonanesthetized Guinea Pigs (Ovalbumin으로 감작된 기니픽에서 Allergen 흡입으로 인한 즉시형 기관지 수축반응에 대한 비침습적 측정)

  • Kim, Je-Hyeong;Shim, Jae-Jeong;Lee, Sung-Yong;Kwon, Young-Hwan;Lee, So-Ra;Lee, Sang-Youb;Cho, Jae-Youn;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.99-106
    • /
    • 1998
  • Background: Bronchial asthma is a complex disease, which is characterized by spontaneous exacerbations of airway obstruction and persistent bronchial hyperresponsiveness. Animal models have fallen short of reproducing the human disease, particularly in mimicking the spontaneous and persistent airflow obstruction that characterized in asthma. In animals, airflow obstruction is usually assessed by measuring airflow resistance during tidal breathing under such invasive technique as tracheostomy and anesthesia. A noninvasive technique for measuring pulmonary function in small animals is needed to evaluate long-term changes in lung function during the course of experimentally produced disease without sacrificing the animal. Purpose: The purpose of this study was to evaluate early bronchoconstrcition after allergen challenge and airway responsiveness (AR) to inhaled methacholine in nonanethetized, unrestrained guinea pigs. Method: Guinea pig model of asthma was sensitized by subcutaneous injection with ovalbumin and challenged by inhalation of aerosolized ovalbumin(1% wt/vol ovlabumin). Airflow obstruction of conscious guinea pig was measured as specific airway resistance (airway resistance $\times$ thoracic gas volume). Airway resistance and thoracic gas volume of conscious guinea pig were assessed by body plethysmography before challenge and at regular intervals for as long as 30 minutes after challenge. AR to aerosolized methacholine of asthma group was compared with that of control group in body plethysmography. Result: Asthma model<> developed in 13 (65%) among 20 guinea pigs, in which early responses occurred in the airways after the exposure to inhalation with ovalbumin. Airway challenge with ovalbumin caused increase in specific airway resistance, which peaked at 6 minutes and amounted to a $231.5{\pm}30.4%$ increase from baseline. AR to aerosolized methacholine of asthma model increased significantly compared with control group. Conclusion: These results have showed a useful animal model to evaluate early bronchoconstrcition after allergen challenge and airway responsiveness in nonanethetized, unrestrained guinea pigs.

  • PDF

Protective Effect of Saengshik Supplementation on Lead Induced Toxicity in Rats (생식의 섭취가 납중독 흰쥐의 피해 경감에 미치는 영향에 관한 연구)

  • Oh, Young-Joo;Kim, Jae-Min;Song, Si-Wan;Ha, Hyo-Cheol;Kim, Hyun-Su
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.7
    • /
    • pp.959-967
    • /
    • 2005
  • Lead is a ubiquitous environmental and industrial pollutant that causes a major health concerns. It is known to induce a broad range of physiological, biochemical, and behavioral dysfunctions in laboratory and humans, including hematopoietic system, kidneys, liver, and reproductive system. This study was conducted to investigate the effect of Saengshik supplementation on the lead-induced toxicity in rats. Five week old male Sprague­Dawley rats were randomly assigned to five groups for six weeks as followings: control group (CT), lead acetate treated group (PT), and lead acetate groups administered with three different dosages of Saengshik $(SI2.5-12.5\%,\;S25-25\%,\;and\;S50-50\%).$ Lead acetate (12 mg/rat) was intragastrically administered daily for 6 weeks. The results were summarized as follows; Weight gain and food efficiency ratio were significantly lower (p<0.05) in lead administered group compared with those of the control group. Also, significant lead-induced alteration in blood hemoglobin (HGB), hematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and reticulocyte distribution width (RDW) were observed. In the liver of lead-exposed animals, there was an increase in the lipid peroxidation (MDA) and the level of glutathione (GSH), but superoxiede dismutase (SOD) activity did not change. Lead-exposed animals with $25\%\;and\;50\%$ Saengshik supplementation showed marked improvements in the values of MCH, MCV, and RDW. Also, the level of HCT was significantly increased by $50\%$ Saengshik supplementation. The levels of liver MDA in $12.5\%\;and\;50\%$ Saengshik administered groups and GSH level in $50\%$ Saengshik administered group were significantly decreased compared to the lead administered group. Also, hepatic SOD activity tended to increase in the presence of Saengshik supplementation. Furthermore, the accumulation of lead in liver and kidney was reduced by presence of Saneghshik supplementation. Liver lead concentration was significantly reduced by both $25\%\;and\;50\%$ Saengshik supplementations and kidney lead concentration was significantly reduced by the $25\%$ Saengshik supplementation. These results show that Saengshik may have a protective effect against lead intoxication but the mechanism of their effects remains unclear.

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters (유방촬영술에서 유리선량계를 이용한 납치마의 선량차폐 효과 측정)

  • Yu, Su-Jeong;Lim, Sangwook;Ma, Sun Young;Seo, Sun-Youl;Kim, Young-Jae;Kang, Young-Nam;Keum, Ki Chang;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.93-98
    • /
    • 2015
  • The purpose of this study is to see the usefulness of lead apron for critical organs near the breast under examining. For clinical experiment, 30 female volunteers who agreed to their participation in the experiments, were chosen and divided into two groups, 15 in group A and 15 in group B respectively. group A is to see whether each side of breast under mammography affects to other side glandular on the critical organs is same, because it is not allowed to scan the both breast for same person or to scan repeatedly. Group B is to see the effectiveness of lead apron during the mammography of right breast. Glass dosimeters were placed on the thyroid, the contralateral breast, and lower abdomen where near the breast during examining. The average glandular doses on the surface in mammography of the thyroid gland, the contralateral breast, the lower abdomen were 0.0692 mGy, 0.6790 mGy, and 0.0122 mGy, respectively, which was an extremely low level of glandular dose. In group B, as to the thyroid gland, average dose was decreased from 0.0922 mGy to 0.0158 mGy. The average dose of contralateral breast was decreased from 0.8575 mGy to 0.0286 mGy. The average doses of lower abdomen was decrease 0.0150 mGy to 0.0173 mGy. As to the lower abdomen, dose decreased from 0.0150 mGy before the use of an apron down to 0.0173 mGy after the use. As p-value was under 0.05, statistically significant difference was observed between the two groups. Wearing an apron can have the protective effects on the thyroid gland up to 20 times lower than not wearing one. Besides, it is also necessary to protect the other breast during the examination by wearing one.

Comparison of Digital Mammography and Digital Breast Tomosynthesis (디지털 유방촬영기기와 3차원 디지털 유방단층영상합성기기의 비교연구)

  • Kim, Ye-Seul;Park, Hye-Suk;Choi, Jae-Gu;Choi, Young-Wook;Park, Jun-Ho;Lee, Jae-Jun;Kwak, Su-Bin;Kim, Eun-Hye;Kim, Ju-Yeon;Jung, Hyun-Jung;Lee, Haeng-Hwa;Bae, Gyu-Won;Lee, Mi-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.261-268
    • /
    • 2012
  • Breast cancer is the second leading cause of women cancer death in Korea. The key for reducing disease mortality is early detection. Although digital mammography (DM) has been credited as one of the major reasons for the early detection to decrease in breast cancer mortality observed in the last 20 years, DM is far from perfect for several limitations. Digital breast tomosynthesis (DBT) is expected to overcome some inherent limitations of conventional mammography caused by overlapping of normal tissue and pathological tissue during the standard 2D projections for the improved lesion margin visibility and early breast cancer detection. In this study, we compared a DM system and DBT system acquired with different thickness of breast phantom. We acquired breast phantom data with same average glandular dose (AGD) from 1 mGy to 4 mGy under same experimental condition. The contrast, micro-calcification measurement accuracy and observer study were conducted with breast phantom images. As a result, the higher accuracy of lesion detection with DBT system compared to DM system was demonstrated in this study. Furthermore, the pain of patients caused by severe compression can be reduced with DBT system. In conclusion, the results indicated that DBT system play an important role in breast cancer detection.

A Study of Various Filter Setups with FBP Reconstruction for Digital Breast Tomosynthesis (디지털 유방단층영상합성법의 FBP 알고리즘 적용을 위한 다양한 필터 조합에 대한 연구)

  • Lee, Haeng-Hwa;Kim, Ye-Seul;Lee, Youngjin;Choi, Sunghoon;Lee, Seungwan;Park, Hye-Suk;Kim, Hee-Joung;Choi, Jae-Gu;Choi, Young-Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.271-280
    • /
    • 2014
  • Recently, digital breast tomosynthesis (DBT) has been investigated to overcome the limitation of conventional mammography for overlapping anatomical structures and high patient dose with cone-beam computed tomography (CBCT). However incomplete sampling due to limited angle leads to interference on the neighboring slices. Many studies have investigated to reduce artifacts such as interference. Moreover, appropriate filters for tomosynthesis have been researched to solve artifacts resulted from incomplete sampling. The primary purpose of this study is finding appropriate filter scheme with FBP reconstruction for DBT system to reduce artifacts. In this study, we investigated characteristics of various filter schemes with simulation and prototype digital breast tomosynthesis under same acquisition parameters and conditions. We evaluated artifacts and noise with profiles and COV (coefficinet of variation) to study characteristic of filter. As a result, the noise with parameter 0.25 of Spectral filter reduced by 10% in comparison to that with only Ramp-lak filter. Because unbalance of information reduced with decreasing B of Slice thickness filter, artifacts caused by incomplete sampling reduced. In conclusion, we confirmed basic characteristics of filter operations and improvement of image quality by appropriate filter scheme. The results of this study can be utilized as base in research and development of DBT system by providing information that is about noise and artifacts depend on various filter schemes.

Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method (Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법)

  • Han, Yong-Hee;Kim, Tae-Hyung;Chun, Song-I;Kim, Dong-Hyeuk;Lee, Kwang-Sig;Eun, Choong-Ki;Jun, Jae-Ryang;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • Purpose : This study proposes the keyhole method in order to improve the time resolution of the proton resonance frequency(PRF) MR temperature monitoring technique. The values of Root Mean Square (RMS) error of measured temperature value and Signal-to-Noise Ratio(SNR) obtained from the keyhole and full phase encoded temperature images were compared. Materials and Methods : The PRF method combined with GRE sequence was used to get MR temperature images using a clinical 1.5T MR scanner. It was conducted on the tissue-mimic 2% agarose gel phantom and swine's hock tissue. A MR compatible coaxial slot antenna driven by microwave power generator at 2.45GHz was used to heat the object in the magnetic bore for 5 minutes followed by a sequential acquisition of MR raw data during 10 minutes of cooling period. The acquired raw data were transferred to PC after then the keyhole images were reconstructed by taking the central part of K-space data with 128, 64, 32 and 16 phase encoding lines while the remaining peripheral parts were taken from the 1st reference raw data. The RMS errors were compared with the 256 full encoded self-reference temperature image while the SNR values were compared with the zero filling images. Results : As phase encoding number at the center part on the keyhole temperature images decreased to 128, 64, 32 and 16, the RMS errors of the measured temperature increased to 0.538, 0.712, 0.768 and 0.845$^{\circ}C$, meanwhile SNR values were maintained as the phase encoding number of keyhole part is reduced. Conclusion : This study shows that the keyhole technique is successfully applied to temperature monitoring procedure to increases the temporal resolution by standardizing the matrix size, thus maintained the SNR values. In future, it is expected to implement the MR real time thermal imaging using keyhole method which is able to reduce the scan time with minimal thermal variations.

  • PDF

Effect of Tightening Torque on Abutment-Fixture Joint Stability using 3-Dimensional Finite Element Analysis (임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구)

  • Eom, Tae-Gwan;Suh, Seung-Woo;Jeon, Gyeo-Rok;Shin, Jung-Wook;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2009
  • Statement of problem: Loosening or fracture of the abutment screw is one of the common problems related to the dental implant. Generally, in order to make the screw joint stable, the preload generated by tightening torque needs to be increased within the elastic limit of the screw. However, additional tensile forces can produce the plastic deformation of abutment screw when functional loads are superimposed on preload stresses, and they can elicit loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum tightening torque that maximizes a fatigue life and simultaneously offer a reasonable degree of protection against loosening. Purpose: The purpose of this study was to present the influence of tightening torque on the implant-abutment screw joint stability with the 3 dimensional finite element analysis. Material and methods: In this study, the finite element model of the implant system with external butt joint connection was designed and verified by comparison with additional theoretical and experimental results. Four different amount of tightening torques(10, 20, 30 and 40 Ncm) and the external loading(250 N, $30^{\circ}$) were applied to the model, and the equivalent stress distributions and the gap distances were calculated according to each tightening torque and the result was analyzed. Results: Within the limitation of this study, the following results were drawn; 1) There was the proportional relation between the tightening torque and the preload. 2) In case of applying only the tightening torque, the maximum stress was found at the screw neck. 3) The maximum stress was also shown at the screw neck under the external loading condition. However in case of applying 10 Ncm tightening torque, it was found at the undersurface of the screw head. 4) The joint opening was observed under the external loading in case of applying 10 Ncm and 20 Ncm of tightening torque. 5) When the tightening torque was applied at 40 Ncm, under the external loading the maximum stress exceeded the allowable stress value of the titanium alloy. Conclusion: Implant abutment screw must have a proper tightening torque that will be able to maintain joint stability of fixture and abutment.

Photoelastic stress analysis of the mandibular unilateral free-end removable partial dentures according to the design (하악 편측 유리단 가철성 국소의치의 설계에 따른 광탄성 응력 분석)

  • Park, Cheol-Woo;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.206-214
    • /
    • 2009
  • Statement of problem: There are common clinical cases in which the mandibular first and second molars are missing unilaterally. Purpose: This study was designed to compare and evaluate the magnitude and distribution of stress produced by four kinds of mandibular unilateral free-end removable partial dentures that could be applied clinically in Kennedy class II cases. Material and methods: Four unilateral free-end removable partial dentures using clasp, Konus crown, resilient attachment, and flexible resin were fabricated on the photoelastic models of the Kennedy class II cases. The vertical load of 6㎏ was applied on the central fossa of the first molar of every removable partial denture in the stress freezing furnace and the photoelastic models were frozen according to the stress freezing cycle. After these models were sliced mesio-distally to a thickness of 6mm, the photoelastic isochromatic white and black lines of the sliced specimens were examined with the transparent photoelastic experiment device and photographs were taken with a digital camera. The fringe order numbers at eight measuring points in the photograph were measured with the naked eye. Results: The maximum fringe order number of each sliced specimen and the fringe order number at the residual ridge just below the loading point were in the decreasing order of the unilateral removable partial dentures using flexible resin followed by clasp, resilient attachment, and Konus crown. The fringe order number at the root apex of the second premolar was in the decreasing order of the unilateral removable partial dentures using clasp followed by flexible resin, Konus crown, and resilient attachment. Conclusion: The removable partial denture using Konus crown showed the most equalized stress distribution to the supporting alveolar bone of abutment teeth and residual ridge under the vertical loads. The removable partial denture using flexible resin can be applied to the case that has a better state of residual ridge than abutment teeth.

Tensile bond strength of chairside reline resin to denture bases fabricated by subtractive and additive manufacturing (적층가공과 절삭가공으로 제작한 의치상과 직접 첨상용 레진 간의 인장결합강도 비교)

  • Kim, Hyo-Seong;Jung, Ji-Hye;Bae, Ji-Myung;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.177-184
    • /
    • 2020
  • Purpose: The purpose of this study was to compare and evaluate the tensile bond strength of chairside reline resin to denture base resin fabricated by different methods (subtractive manufacturing, additive manufacturing, and conventional heat-curing). Materials and methods: Denture base specimens were fabricated as cuboid specimens with a width of 25 mm × length 25 mm × height 3 mm by subtractive manufacturing (VITA VIONIC BASE), additive manufacturing (NextDent Base) and conventional heat-curing (Lucitone 199). After storing the specimens in distilled water at 37℃ for 30 days and drying them, they were relined with polyethyl methacrylate (PEMA) chairside reline resin (REBASE II Normal). The subtractive and additive manufacturing groups were set as the experimental group, and the heat-curing group was set as the control group. Ten specimens were prepared for each group. After storing all bound specimens in distilled water at 37℃ for 24 hours, the tensile bond strength between denture bases and chairside reline resin was measured by a universal testing machine at a crosshead speed of 10 mm/min. The fracture pattern of each specimen was analyzed and classified into adhesive failure, cohesive failure, and mixed failure. Tensile bond strength, according to the fabrication method, was analyzed by 1-way ANOVA and Bonferroni's method (α=.05). Results: Mean tensile bond strength of the heat-curing group (2.45 ± 0.39 MPa) and subtractive manufacturing group (2.33 ± 0.39 MPa) had no significant difference (P>.999). The additive manufacturing group showed significantly lower tensile bond strength (1.23 ± 0.36 MPa) compared to the other groups (P<.001). Most specimens of heat-curing and subtractive manufacturing groups had mixed failure, but mixed failure and adhesive failure showed the same frequency in additive manufacturing group. Conclusion: The mean tensile bond strength of the subtractive manufacturing group was not significantly different from the heat-curing group. The additive manufacturing group showed significantly lower mean tensile bond strength than the other two groups.