• Title/Summary/Keyword: 일정체적

Search Result 224, Processing Time 0.021 seconds

A Preliminary Mortar Test to Minimize the Paste Volume of Concrete (콘크리트의 페이스트 체적을 최소화하기 위한 예비 모르타르 시험)

  • Choi, Jae-Jin;Choi, Doo-Sun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.741-744
    • /
    • 2008
  • There are two ways to reduce cement content for a given quality level(strength, workability etc.) in concrete. First, reducing the required paste volume by varying the shape or the grading of aggregates. Secondly, holding the paste volume constant while replacing cement volume with mineral admixtures or mineral fillers. And It will also be proved that the required minimum paste volume is independent of the paste composition, provided the paste composition is in a reasonable range. In this study, therefore, we have an object to determine the required minimum paste volume for a given workability level. For this purpose, we tried the following experiments: vary the paste volume for the three different grading of aggregates and determine the minimum paste volume to achieve a certain level of workability with high-range water reducing admixture.

  • PDF

Bladder volume variations of cervical cancer patient in radiation therapy using ultrasonography (초음파검사를 이용한 자궁경부암 환자의 방사선치료 시 방광 체적 변화)

  • Gong, Jong Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.131-137
    • /
    • 2016
  • Purpose : The bladder volume change was measured using ultrasonography for helping decrease the side effects and other organ variations in the location of radiation therapy for cervical cancer patients. An experiment was performed targeting patients who were treated with radiation therapy at PNUH within the period from September to December 2015. Materials and Methods : To maintain the bladder volume, each patient was instructed to drink 500 cc water before and after CT simulation, 60 minutes before the dry run. Also, the bladder volume was measured in each patient CT scan, and a 3D conformal therapy plan was designed. The bladder volumes measured before and after the CT simulation, dry run, and radiation treatment planning were compared and analyzed. Results : The average volume and average error of the bladder that were obtained from the measurement based on the CT scan images had the lowest standard deviation in the CT simulation. This means that the values that were obtained before and after the CT simulation were statistically relevant and correlative. Moreover, the bladder volume measured via ultrasonography was larger size, the average volume in the CT scan. But the values that were obtained Dry run and after the CT simulation were not statistically relevant. Conclusion : Drinking a certain amount of water helps a patient maintain his/her bladder volume for a dry run. Even then, it is difficult to maintain the bladder volume for the dry run. Also, whether or not the patients followed the directions for the dry run correctly is important.

  • PDF

Buckling Loads and Post-Buckling Behaviors of Shear Deformable Columns with Regular Cross-Section (전단변형을 고려한 정다각형 단면 기둥의 좌굴하중 및 후좌굴 거동)

  • Lee, Byeoung Koo;Lee, Tae Eun;Kwon, Yun Sil;Kim, Sun Gi
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.6
    • /
    • pp.683-691
    • /
    • 2001
  • Numerical methods are developed for solving the elastica and buckling load of tapered columns with shear deformation, subjected to a compressive end load. The linear, parabolic and sinusoidal tapers with the regular polygon cross-sections are considered, whose material volume and span length are always held constant. The differential equations governing the elastica of buckled column are derived. The Runge-Kutta method is used to integrate the differential equations, and the Regula-Falsi method is used to determine the rotation at left end and the buckling load, respectively. The numerical methods developed herein for computing the elastica and the buckling loads of the columns are found to be efficient and reliable.

  • PDF

Elastica of Cantilever Column with Constant Volume Subjected to Combined Loads (조합하중을 받는 일정체적 캔틸레버 기둥의 정확탄성곡선)

  • Lee, Byoung-Koo;Li, Guangfan;Yoon, Hee-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.581-592
    • /
    • 2007
  • This paper deals with the elastica of deflected cantilever column with the constant volume. The columns are subjected to combined loads consisted of an axial compressive load and a couple moment at the free end. Differential equations governing the elastica of such column are derived, in which both the effects of taper type and shear deformation are included. Three kinds of taper types are considered: linear, parabolic and sinusoidal tapers. Differential equations are solved numerically to obtain the elastica of objective columns. The effects of various system parameters on the elastica are investigated extensively. Experimental studies were carried out in order to verify the theoretical results of non-linear behavior of the elasticas.

Free Vibrations and Buckling Loads of Tapered Beam-Columns of Regular Polygon Cross-section with Constant Volume (일정체적의 정다각형 단면을 갖는 변단면 보-기둥의 자유진동 및 좌굴하중)

  • Lee, Byong Koo
    • Journal of KSNVE
    • /
    • v.6 no.5
    • /
    • pp.587-594
    • /
    • 1996
  • The differential equation governing both the free vibrations and buckling loads of tapered beam-columns of regular polygon cross-section with constant volume were derived and solved numerically. The parabolic and sinusoidl tapers were chosen as the variable depth of cross-section for the tapered beam-column. In numerical examples, the clamped-clamped, hinged-clamped and hinged-hinged end constraints were considered. The variations of frequency parameters and first buckling load parameters with the non-dimensional system parameters are reported in figures, and typical vibrating mode shapes are presented. Also, the configurations of strongest columns were determined.

  • PDF

Dynamic Optimal Shapes of Simple Beam-Columns with Constant Volume (일정체적 단순지지 보-기둥의 동적 최적단면)

  • Lee, Byoung Koo;Park, Kwang Kyou;Mo, Jeong Man;Lee, Sang Jin
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.221-228
    • /
    • 1997
  • The main purpose of this paper is to determine the dynamic optimal shapes of simple beam-columns with the constant volume. The parabolic function is chosen as the variable equation for the depth of regular polygon cross-section. The ordinary differential equation including the effect of axial load is applied to calculate the natural frequencies. The Runge-Kutta and Regula-Falsi methods are used to integrate the differential equation and compute the frequencies, respectively. Then the dynamic optimal shape whose lowest natural frequency is highest is determined by reading the critical value of the frequency versus section ratio curve plotted by the frequency data. In the numerical examples, the simple beam-columns are analysed and the numerical results of this study are shown in tables and figures.

  • PDF

Static and Dynamic Optimal Shapes of Both Clamped Columns with Constant Volume (일정체적 양단고정 기둥의 정·동적 최적형상)

  • Lee, Byoung Koo;Kim, Suk Ki
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.99-106
    • /
    • 2007
  • This paper deals with the static and dynamic optimal shapes of both clamped columns with constant volume. The parabolic taper with the regular polygon cross-section is considered, whose material volume and column length are held constant. Numerical methods are developed for solving natural frequencies and buckling loads of columns subjected to an axial compressive load. Differential equations governing the free vibrations of such column are derived. The Runge-Kutta method is used to integrate the differential equations, and the Regula-Falsi method is used to determine natural frequencies and buckling loads, respectively. From the numerical results, dynamic stability regions, dynamic optimal shapes and configurations of strongest columns are presented in figures and tables.

Strongest Static Arches with Constant Volume (일정체적 정적 최강아치)

  • Lee, Byoung Koo;Oh, Sang Jin;Lee, Tae Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.477-486
    • /
    • 2009
  • This paper deals with the strongest static arches with the solid regular polygon cross-section. Both span length and volume of arch are always held constant regardless the shape functions of cross-sectional depth of regular polygon. The normal stresses acting on such arches are calculated when both static vertical and horizontal point loads are subjected. By using the calculating results of stresses, the optimal shapes of strongest static arches are obtained, under which the maximum normal stress become to be minimum. For determining the redundant of such indeterminate arches, the least work theorem is adopted. As the numerical results, the configurations, i.e. section ratios, of the strongest static arches are reported in tables and figures. The results of this study can be utilized in the field of the minimum weight design of the arch structures.

Static and Dynamic Stability Analyses of Simple Tapered Columns with Constant Volume (일정체적 단순지지 변단면 기둥의 정·동적 안정해석)

  • Lee, Byoung Koo;Kim, Suk Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3A
    • /
    • pp.533-538
    • /
    • 2006
  • This study deals with the static and dynamic stability analyses of simple tapered columns with constant volume. The crosssections of column taper are the regular polygons whose depths are varied with the parabolic functional fashion. The hingedhinged end constraint is chosen as the boundary condition of the column. The non-dimensional ordinary differential equation governing free vibrations of such column subjected to an axial load is derived and solved numerically. From numerical results, the relationships between natural frequencies and section ratios are obtained, from which the configurations of dynamic optimal shapes of columns and the strongest columns are extracted.

Bladder Volume Variations in Patients Receiving Conformal Radiotherapy to Prostate (전립선암 환자의 방사선 치료 시 방광 체적 변화)

  • Lee, Re-Na;Lee, Ji-Hye;Lee, Kyung-Ja;Ji, Young-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.61-65
    • /
    • 2008
  • Objective: To reduce urinary side effects in prostate cancer patients receiving radiation, patients were asked to drink certain amount of water to maintain bladder volume constant and the bladder volumes were measured weekly using ultrasound scanner. Materials and Methods: Twenty-six patients with prostate cancer who received radiation between December 2002 and August 2007 were enrolled in this study. Thirteen patients were enrolled in experimental group. These patients were asked to drink 450 cc of water, one hour prior to simulation, CT scan, and treatment. The other thirteen patients were given no information about bladder filing. Bladder, prostate, and rectum were contoured on CT and volumes were calculated. 3D conformal treatment planning was performed and effective volumes of bladder were calculated when a prescription dose of 70.2 Gy was delivered. For the patients in experimental group, bladder volumes were measured weekly using ultrasound scanner for 6-8 weeks and the bladder volume variations were analyzed. Results: Average bladder volumes and standard deviations obtained at CT scanning were $283.5{\pm}114.0\;cc$ (40%) and $181.2{\pm}120.1\;cc$ (66%) in experimental and control groups, respectively. Although it was not statistically significant, there was correlation between the bladder volumes measured from CT and ultrasound. The volumes measured using ultrasound scanner were 62% lower than the volumes using CT images on average. There was significant variations in volumes measured weekly for 6-8 weeks. It ranged between 33 - 75 %. Conclusion: Our results showed that it is possible to obtain larger bladder volume if they are asked to drink certain amount of water prior to CT scan. However, patients were unable to maintain constant bladder volumes over the 6-8 weeks of treatment period although they were asked to drink constant amount of water.