• 제목/요약/키워드: 일사열 차폐

검색결과 7건 처리시간 0.019초

하절기 내측 블라인드의 유형별 일사차폐성능 비교 실측연구 (An Experimental Study on Comparing Solar Heat Shading Performances in Accordance with the Type of Internal Blinds in the Summer)

  • 박은미;최동호
    • 한국태양에너지학회 논문집
    • /
    • 제36권4호
    • /
    • pp.1-9
    • /
    • 2016
  • The purpose of this study was to compare heat shading performance of various blind types in summer. 4 types of blinds were employed and the results are summarized as follows: 1) There were significant differences in indoor thermal environment and heat shading performance between different heat shading devices, and functional blinds demonstrated relatively superior heat shading performance. 2) Indoor long wave radiation influx measures were lowest for the coating roll blind (Blind B), followed by the coating venetian blind (Blind C), the venetian blind (Blind A), the roll blind, and not having any blinds at all. 3) Such examination results carry implications to reduce cooling load and enhance the indoor environment.

내측 블라인드의 하절기 일사열 차폐 성능 비교 (Comparing Solar Heat Shading Performances of Internal Blinds in the Summer)

  • 박은미;최동호;박민용;이경희
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.75-83
    • /
    • 2014
  • Heat loss through windows and doors occupies 20 to 45% of the total heat loss in building. It accounts for a large proportion of the total heat loss in building. In order to suppress the amount of heat flow through the windows and doors were considered actions such as reinforcement of insulation performance of window, adoption of low-e glass, and installation of solar heat shading device. The Purpose of this study is to compare solar heat shading performances of 3 types of internal blinds in the summer. In order to verify the solar heat shading performances of the blinds, a roll blind, blind A(Venetian blind) and blind B(Daylight guiding venetian blind)were installed in the four rooms with the same environmental conditions. As a result of the experiment, the blind B, blind A, roll blind showed an excellent performance in that order. Its because the blind B is made of aluminum materials coated with special paints on surface. It doesn't converted to long wave by short wave light. and it is reflected to short wave to outside.

일사차단용 설비를 이용한 냉방 에너지 절약 방안 (Cooling Energy Saving System using Solar Heat Protection Dvices)

  • 정기범;최상곤
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.108-115
    • /
    • 2010
  • Global warming and heat island make the outdoor air temperature ascend. Tall office buildings are covered with glass window facades as a design aspect and the portion of window area to facade area is increasing. Hence, cooling load for solar radiation passing through glass window is rising. Cooling air to a certain room is supplied equally despite the face of the room in most office buildings. Especially, the west part of the office cannot maintain the required temperature that occupant needs because of the solar heat coming through windows.?In this study, we projected the water spray system to reduce the solar heat transfer and to reflect the solar ray through windows. We perform the experiments to evaluate the performance of the solar heat protection devices. We measured the room temperature of two separated office rooms for solar heat control devices. The investigation's results show that the water spray system is sufficient to the coated glass and the venetian blinds for the decrease of the solar heat inflow.

옥상녹화에 따른 콘크리트 건축물의 열환경 개선효과 -일사차폐블록과 잔디를 대상으로- (Study on Improvement of Thermal Environment by Green Roof Systems on RC Building - utilization of solar insulating block and the grass -)

  • 박찬필;후루가와 노부히사
    • 한국환경복원기술학회지
    • /
    • 제7권1호
    • /
    • pp.1-9
    • /
    • 2004
  • Caused on the excessive heat accumulation of concrete material, the indoor thermal environment of reinforced concrete building is so bad in Okinawa. As the interruption of solar radiation could be one of the methods to improve it, the purpose of this study is to find out the effect of adopting solar radiation interrupting materials -Solar insulating block, Grass, and both of them- for the improvement of thermal environment. As the result, it was found that grass on the solar insulating block which has an air layer obviously improved the indoor thermal environment of RC building which was applied to. And it was found that the systems have an effectuality on heat island phenomenon simultaneously. It could be proposed as a good system which improve the indoor thermal environment of the existent houses.

하절기 조경용 녹음수 수관 하부의 일사와 평균복사온도 비교 (The Comparison of the Solar Radiation and the Mean Radiant Temperature (MRT) under the Shade of Landscaping Trees in Summertime)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제42권5호
    • /
    • pp.22-30
    • /
    • 2014
  • 조경용 녹음수가 하절기 옥외공간에서 인간이 느끼는 열쾌적성에 미치는 효과를 객관적으로 검증하기 위하여 수형이 서로 다른 미국참나무, 배롱나무, 참느릅나무 등 세 종의 수목를 선정하여 일사차단율과 평균복사온도 저감 효과를 비교분석하였다. 또한, 주기적으로 수관부 사진을 촬영하여 수관부의 변화특성도 비교 검토하였다. 일사량과 건구온도, 흑구온도를 현장에서 자동으로 계측 기록할 수 있는 시스템을 구축하여 각 수목의 수관 하부에 지면으로부터 1.1m 위치에 설치하고, 2013년 4월 1일부터 동년 11월 30일까지 매 분 단위로 기록될 수 있도록 설정하였다. 수관의 천공차폐율 분석결과, 비교적 일정한 상태를 유지한 것으로 나타난 2013년 6월 1일부터 동년 8월 30일까지의 자료 중, 우천과 이상 기상일 자료를 제외한 오전 10시에서 오후 2시까지의 자료를 통계 분석에 이용하였다. 10분 단위 평균값으로 환산된 총 6,640건의 흑구온도와 건구온도를 바탕으로 평균복사온도를 환산하였으며, 이를 각 시험구의 일사량과 비교 분석하였다. 분석 대상 기간 중 미국참나무와 배롱나무, 참느릅나무 수관부의 평균 천공차폐율은 각각 99%, 98%, 97%였으며, 각 수관하부에 도달한 평균 태양 복사량은 $106W/m^2$, $163W/m^2$, $202W/m^2$로 대조구의 $823W/m^2$와 비교했을 때, 최소 75%이상이 차단된 것으로 나타났다. 또한, 평균복사온도의 경우, 각각 $30.34^{\circ}C$, $33.34^{\circ}C$, $34.77^{\circ}C$로 계산되어 대조구의 $46.0^{\circ}C$와 비교했을 때, 적게는 $10^{\circ}C$에서 많게는 $16^{\circ}C$까지 수목의 수관부에 의해서 저감된 것으로 나타났다. 일사량과 평균복사온도의 관계를 회귀분석한 결과, 매우 밀접한 선형관계를 형성하고 있었으며, 설명력도 매우 높게 분석되었다. 결론적으로 본 연구를 통해서 하절기 옥외공간에서 녹음수의 수관은 일사량의 상당부분을 차단함으로써 인간이 체감하는 열쾌적성을 개선하는데 매우 중요한 역할을 하고 있다는 점을 객관적으로 확인할 수 있었다. 따라서, 옥외공간에 더 많은 녹음수와 숲을 조성하여 그늘 지역을 증가시킴으로써 인간의 하절기 옥외활동에 부정적 영향을 주고 있는 불필요한 열에너지를 현격하게 저감시켜 쾌적한 열환경을 효과적으로 조성할 수 있을 것이다.

교통량을 고려한 열수지법에 의한 노면온도 예측모형의 구축 (Developing a Model to Predict Road Surface Temperature using a Heat-Balance Method, Taking into Traffic Volume)

  • 손영태;전진숙;황준문
    • 한국ITS학회 논문지
    • /
    • 제14권2호
    • /
    • pp.30-38
    • /
    • 2015
  • 본 연구는 동절기 도로관리서비스 향상과 도로의 안전성을 제고하기 위하여, 기존의 입력자료인 기상자료와 더불어 추가적으로 교통자료를 적용하여 노면온도를 예측할 수 있는 모형의 개발을 목표로 하였다. 노면온도 예측모형은 열수지법을 적용하였으며, 모형에서 교통량에 대한 고려는 차량 복사열, 타이어 마찰열로 구성하여 모형화하였다. 이 최종모형과 기상 조건을 기초로 한 초기 모형과 비교하여 노면온도에 미치는 교통량의 영향을 검토하였다. 제3경인고속도로의 실제 관측치과 두 모형에서 계산된 노면온도를 실제 노면온도 관측치와의 비교로 검증하였는데, 관측치와 예측치의 오차인 RMSE은 $1.97^{\circ}C$였다. 관측된 노면온도는 오전 6시부터 일사의 영향을 받아 급격히 상승하여 14시에 최대가되고, 그 후에는 감소한다. 모형 예측값은 관측값보다 오후에는 낮고, 야간에는 높게 나타났다. 이는 오후의 경우는 차량으로 인한 태양 복사열의 차폐, 야간의 경우는 차량열에 의한 열 공급이 주요 원인인 것으로 판단된다.