• Title/Summary/Keyword: 일본 재난관리

Search Result 69, Processing Time 0.028 seconds

A Fundamental Study on the Database of Response History for Historical Earthquake Records on the Korean Peninsula (한반도 과거 지진기록에 대한 응답이력 데이터베이스 구축 기초 연구)

  • Choi, Inhyeok;Ahn, Jae-Kwang;Kwak, Dongyoup
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.821-831
    • /
    • 2019
  • The 9.12 earthquake (2016.9.12., ML=5.8) and Pohang (2017.11.15., ML=5.4) caused social and economic damage, resulting in a greater public interest in earthquakes than in the past. In the U.S., Japan and Chile, which have high frequency of earthquakes, infrastructure facilities are already managed based on probabilistic seismic hazard analysis (PSHA) and ground motion prediction equation (GMPE) to prepare for and respond to seismic disasters. In South Korea, the aforementioned PSHA and GMPE models have been developed independently through individual researchers. However, the limited disclosure of basic data, calculation methods, and final results created during the model development poses a problem of deploying new data without updating the earthquake that occurs every year. Therefore, this paper describes how to create flatfile, which is the basic data of GMPE, and how to process for seismic waves, and how to create intensity measures.

A Study on the fire safety guide for notifying how to cope with the fire in the subway. - Focus on TOKYO BOUSAI safety guide in Japan - (지하철 화재 안전 가이드 방안 연구 - 일본의 도쿄방재 안전 가이드를 중심으로 -)

  • Park, Mi-Seon;Kim, Seung-In
    • Journal of Communication Design
    • /
    • v.57
    • /
    • pp.398-407
    • /
    • 2016
  • This thesis is about how to let people be aware of the importance to raise awareness of the safety by offering User-center guide line instead of staff-center guide line. That's why it is important to make clear and be aware of how to prevent and how to cope with accident because it can lead to casualties which might be a tragic. For all that the guide for the fire accident is posted on the web site of each metro administration without any standard of information or coherence. Therefore it is urgent to make and provide new User-center guideline and to make it better we need to keep the following principles. First of all, the principles of Universal design should be applied to all the User-center guide line for fire accident at the subway station based on the comprehension of public design. Secondly, every metro administration need more communication to organize one coherence in designing instead of unilateral advertisement. Lastly, campaigns and training should be expanded in everyday life, so the citizen can raise awareness of the accident by themselves.

A Comparative Study on Each Nation's Counter terrorism Organization and Function (각국의 테러대응 조직과 기능의 비교 연구)

  • Kwon, Jeong-Hoon;Kim, Tae-Hwan
    • Korean Security Journal
    • /
    • no.20
    • /
    • pp.45-69
    • /
    • 2009
  • This study is to present effective and rational strategies by comparing and analyzing plans of some nations such as the United States, Britain, Germany and Japan against terrorism. Nations mentioned above have made alliance to prevent the possible terrorism after 9.11 attack and performed various tasks efficiently. The result of this study is summarized as follows. First, it is required that there should be an integrated system which works properly. Each nation has not distinguished natural disaster from man-made one based on the damage and the abilities of authorities to deal with. On the other hand, South Korea tells two disasters according to causes and runs distributed systems in which each government division performs its duties to manage each disaster. Accordingly, in economic terms, it is much more effective to provide integrated counter terrorism, not distributed one. Second, information sharing must be stimulated. To take actions quickly when an accident occurs, the government needs to have united and integrative systems, which make it prepare for various types of terrorism well. In addition, it is necessary for a government-related organization to tie up with other channels for collecting, analyzing and sharing information. For this, integrative systems for terrorism should be taken into consideration.

  • PDF

Assessment of Precipitation Characteristics and Synoptic Pattern Associated with Typhoon Affecting the South Korea (우리나라 내습태풍 유형에 따른 강우특성 및 종관기후학적 분석)

  • Kim, Tae-Jeong;Park, Kun-Chul;Kwon, Hyun-Han
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.6
    • /
    • pp.463-477
    • /
    • 2015
  • The recent unusual climate and extreme weather events have frequently given unexpected disaster and damages, facing difficulties in the management of water resources. In particular, climate change could result in intensified typhoons, and this would be the worst case scenario that can happen. The primary objective of this study is to identify the patterns of typhoon-induced precipitation and the associated synoptic pattern. This study focused on analyzing precipitation patterns over the South Korea using historic records as opposed to a specified season or duration, and further investigates the potential connection with heavy rainfall to synoptic patterns. In this study, we used the best track data provided by the Regional Specialized Meteorological Center of Japan for 40 years from 1973 to 2012. The patterns of the typhoon-induced precipitation were categorized into four groups according to a given typhoon track information, and then the associated synoptic climatology patterns were further investigated. The results demonstrate that the typhoon-induced precipitation patterns could be grouped and potentially simulated according to the identified synoptic patterns. Our future work will focus on developing a short-term forecasting model of typhoon-induced precipitation considering the identified climate patterns as inputs.

The Improvement Measures for the Establishment of Emergency Management System in Private Security (위험사회의 전개에 따른 민간경비 산업의 대응과제 - 위기관리를 중심으로)

  • Park, Dong-Kyun
    • Korean Security Journal
    • /
    • no.10
    • /
    • pp.103-125
    • /
    • 2005
  • Hazard are defined here as threat to life, well-being, material goods and environmental from the extremes of natural processes or technology. The challenges of natural and technology in increasing the exposure of people and property to risk pose a dilemma for any government seeking the fullest protection for its people and their property. As society progresses and as technology improves and becomes ever more intricate and far reaching, the human species is confronted with increasingly diverse and numerous catastrophic events. Not so infrequently, unfortunately, the impact of either a man-made or natural disaster is compounded by the fact that policy makers have neither prepared themselves or the public to respond appropriately to a disaster once the tragedy has struck. Many concerns have been raised for importance of emergency management after 1990's numerous urban disasters in Korea. Emergency management is the discipline and profession of applying science, technology, planning, and management to deal with extreme events that can injure or kill large numbers of people, cause extensive damage to property, and disrupt community life. When the primary function of private security is to protect lives and property of clients, emergency management should be included in the security service and many countermeasures should be carried out for that purpose. The purpose of this study is to establish ways and means needed to improve the private security emergency management system in Korea. This study is spilt into four chapters. Chapter I is the introduction part. Chapter II introduces the reader to a private security and emergency management theory, and Chapter III deals with the establishment of an effective emergency management system in Korea private security, Chapter IV is a conclusion. Policy makers and private security industry employers in Korea has not concerned with the importance of training and education by lack of recognition and has been passive about qualified guards. And the authorities supervising and the administrating the guards has not recognized the importance of private security and has neglected the training of the guards. In theses contexts, private security should develop and maintain a educational program of emergency management to meet their responsibilities to provide the protection and safety of the clients. Today's modern corporate security director, is, first of all, a competent, well-rounded business executive and, second, a 'service expert'. And, emergency management personnel in private security industry need continuous training.

  • PDF

A Study on the Flammability and Combustion Risk of Biodiesel Mixture (바이오디젤 혼합물의 인화 및 연소 위험성에 관한 연구)

  • Kim, Ju Suk;Ko, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.10-24
    • /
    • 2021
  • Purpose: The purpose of this study is to determine the dangers of biodiesel and general diesel mixtures currently used as alternative fuels by equipment (tag method and penski Marten method) and to determine the difference between flash point and combustion point (closed, open) according to test methods. It is intended to be used as a reference material for identification and evaluation of firecausing substances by confirming the risk of mixtures by comparative analysis and measurement, and establishing a risk assessment method for chemical substances. Method: Flash point test method and result treatment were tested based on ASTM and KS M mode, which are tag sealing and pen schematense test methods used as flash point and combustion point test methods for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was a test equipment that satisfies the test standards of KS M 2010 with equipment produced by TANAKA of Japan. The flash point and combustion point were measured, and the flash point according to the test method of biodiesel and general diesel mixture ( Closed, open), and the ignition point of a mixture of biodiesel and general diesel was compared and analyzed for ignition risk compared with conventional diesel. Results: Looking at the experimental results, first, as an analysis of the risk of flammability of the mixture, the flash point of a substance containing 70% biodiesel was found to be about 92℃ based on general diesel with a flash point of 64.5℃, and gasoline and biodiesel or When the biodiesel mixture was synthesized, it was confirmed that the flash point tends to decrease. In addition, the difference between the flash point and the combustion point was analyzed as about 20 ~ 30℃, and when a small amount of gasoline or methanol was mixed, the flash point was lowered, but it was confirmed that the combustion point was similar to that of the existing mixture. Conclusion: In this study, in order to secure the effectiveness of the details of the criteria for judging dangerous materials in the existing Dangerous Materials Safety Management Act, and to secure the reliability and reproducibility of the judgment of dangerous materials, we confirm the criteria for judging the risk of the mixture through an experimental study on flammable mixtures. It will be able to provide reference data for experimental criteria for flammable liquids that are regulated in the field. In addition, if this study accumulates know-how on experiment by test method, it is expected that it can be used as a basis for research on risk assessment and research on dangerous goods.

A Study on Flammability Risk of Flammable Liquid Mixture (가연성 액체 혼합물의 인화 위험성에 관한 연구)

  • Kim, Ju Suk;Koh, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.701-711
    • /
    • 2020
  • Purpose: In this study, the risk of flammability of a liquid mixture was experimentally confirmed because the purpose of this study was to confirm the increase or decrease of the flammability risk in a mixture of two substances (combustible+combustible) and to present the risk of the mixture. Method: Flash point test method and result processing were tested based on KS M 2010-2008, a tag sealing test method used as a flash point test method for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was Japan's TANAKA. The flash point was measured with a test equipment that satisfies the test standards of KS M 2010 with equipment produced by the company, and LP gas was used as the ignition source and water as the cooling water. In addition, when measuring the flash point, the temperature of the cooling water was tested using cooling water of about 2℃. Results: First of all, in the case of flammable + combustible mixtures, there was little change in flash point if the flash point difference between the two substances was not large, and if the flash point difference between the two substances was low, the flash point tended to increase as the number of substances with high flash point increased. However, in the case of toluene and methanol, the flash point of the mixture was lower than that of the material with a lower flash point. Also, in the case of a paint thinner, it was not easy to predict the flash point of the material because it was composed of a mixture, but as a result of experimental measurement, it was measured between -24℃ and 7℃. Conclusion: The results of this study are to determine the risk of mixtures through experimental studies on flammable mixtures for the purpose of securing the effectiveness of the details of the criteria for determining dangerous goods in the existing dangerous goods safety management method and securing the reliability and reproducibility of the determination of dangerous goods Criteria have been presented, and reference data on experimental criteria for flammable liquids that are regulated in firefighting sites can be provided. In addition, if this study accumulates know-how on differences in test methods, it is expected that it can be used as a basis for research on risk assessment of dangerous goods and as a basis for research on dangerous goods determination.

A Study on Required Safe Egress Time (RSET) Comparison and Error Calculation in Relation to Fire Room Range Set Conditions of Performance Based Fire Safety Designers (성능위주설계자들의 화재실 범위 설정 방식에 따른 소요피난안전시간(RSET) 비교 및 오차산정에 관한 연구)

  • Baek, Sona;Choi, Jun-Ho;Hong, Won-Hwa;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.73-78
    • /
    • 2016
  • The Installation, Maintence, and Safety Control of Fire-fighting Systems Act of South Korea regulates that over 30-storey high-rise buildings including underground spaces should vitally perform the Performance-based Design to minimize property damage and personal injury as a fire risk assessment in advance. Therefore a PBD designer such as a fire safety professional engineer evaluate occupant's life safety by a scientific methodology. In order to evaluate the life safety, fire safety designers calculate the Required Safety Egress Time (RSET) which does not have the legal criteria regarding the standard method of calculation yet. So this way has been showing different results depending upon the designer's choice, knowledges and experiences. In this study, RSET calculation methods by six designers respectively were analysed from the thirteen reports of real performance based design projects conducted in Busan for a last five years. In particular, the Response Time calculation methods which have the most powerful effect for figuring the RSET are compared with the other designer's to deduce an error value.

A Study on Risk Assessment Method for Earthquake-Induced Landslides (지진에 의한 산사태 위험도 평가방안에 관한 연구)

  • Seo, Junpyo;Eu, Song;Lee, Kihwan;Lee, Changwoo;Woo, Choongshik
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.694-709
    • /
    • 2021
  • Purpose: In this study, earthquake-induced landslide risk assessment was conducted to provide basic data for efficient and preemptive damage prevention by selecting the erosion control work before the earthquake and the prediction and restoration priorities of the damaged area after the earthquake. Method: The study analyzed the previous studies abroad to examine the evaluation methodology and to derive the evaluation factors, and examine the utilization of the landslide hazard map currently used in Korea. In addition, the earthquake-induced landslide hazard map was also established on a pilot basis based on the fault zone and epicenter of Pohang using seismic attenuation. Result: The earthquake-induced landslide risk assessment study showed that China ranked 44%, Italy 16%, the U.S. 15%, Japan 10%, and Taiwan 8%. As for the evaluation method, the statistical model was the most common at 59%, and the physical model was found at 23%. The factors frequently used in the statistical model were altitude, distance from the fault, gradient, slope aspect, country rock, and topographic curvature. Since Korea's landslide hazard map reflects topography, geology, and forest floor conditions, it has been shown that it is reasonable to evaluate the risk of earthquake-induced landslides using it. As a result of evaluating the risk of landslides based on the fault zone and epicenter in the Pohang area, the risk grade was changed to reflect the impact of the earthquake. Conclusion: It is effective to use the landslide hazard map to evaluate the risk of earthquake-induced landslides at the regional scale. The risk map based on the fault zone is effective when used in the selection of a target site for preventive erosion control work to prevent damage from earthquake-induced landslides. In addition, the risk map based on the epicenter can be used for efficient follow-up management in order to prioritize damage prevention measures, such as to investigate the current status of landslide damage after an earthquake, or to restore the damaged area.