• Title/Summary/Keyword: 인체 횡단면

Search Result 5, Processing Time 0.016 seconds

An Observational Study on the Morphological Changes of the External Ear Canal by Converging DICOM Imaging and Design Modeling (DICOM 영상과 설계 모델링을 융합한 외이도의 형태적 변화 관찰 연구)

  • Kim, Hyeong-Gyun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.11
    • /
    • pp.173-179
    • /
    • 2019
  • DICOM(Digital Imaging and Communications in Medicine) imaging plays a significant role in the diagnosis and treatment of the human body, and design modeling is a technology of planning shapes in three dimensions according to the purpose. In this study, we converge these two technologies to observe the relationships of the cross-section, volume, and surface area to the morphological changes of the external ear canal. The experiment applied medical imaging technologies to acquire sections of the human body to create and divide centerlines using 3D shapes extracted from 19 external ear canals by applying stereolithography and 3-matic program. The results showed that the cross-sectional structure of the external ear canal had various shapes, such as oval (38.5%), semicircular (28.2%), mixed (17.9%), square (10.2%), and wrinkled (5.1%). In addition, the cross-sectional area of each phase increased as the length of the external ear canal increased, and the volume and surface area decreased towards the direction of the eardrum. However, the surface area reduction rate was relatively low. This indicates that the structure becomes irregular towards the direction of the eardrum.

Analysis of Bodice Patterns Developed through Draping Method Using the Dress Form Representing Korean Female Fashion Models' Body Features (국내 여성 패션모델 체형 반영 인대 활용을 통한 입체재단 제작 길원형 특성 분석)

  • Park, Gin Ah
    • Journal of Fashion Business
    • /
    • v.21 no.1
    • /
    • pp.74-87
    • /
    • 2017
  • The aim of this study was to analyze the features of bodice patterns modeled using a dress form that represents Korean female fashion models' body features. A controlled experiment was carried out using an existing dress form that has been frequently used in South Korea. The purpose of the study was to suggest notable findings derived from understanding the development of bodice patterns for Korean female fashion models. The comparison of features of bodice patterns from the developed and existing dress forms was carried out with consideration of the upper body features of the developed dress form, such as body angles and body cross-sectional shapes. The following results were derived from the investigations. (1) The angles of the upper and lower breast cups of the developed dress form differed to those of the existing dress form, showing a 5.0cm smaller front shoulder dart and a 3.5 larger ㎝ ㎝ front waist dart within the bodice patterns. (2) The body angle features of the developed dress form included a straighter neck and shoulder blade and more concave center back than the existing dress form, with a 2.0 reduced back neck height and a 4.8 larger back waist dart for ㎝ ㎝ the bodice back panel. The more realistic body angles of the developed dress form anticipate the improvement of garment pattern-making. (3) The altered shoulder angles resulted in an increased size of the back shoulder dart and a decreased size of the front shoulder height within the bodice patterns. (4) The increased rate of curvature of cross-sectional shapes on the bust and waist circumferences of the developed dress form resulted in an increase in the sizes of the front and back waist darts.

Assessment of Imaging Distortion in Magnetic Resonance Imaging for Stereotactic Radiosurgery: Through Phantom Study (뇌정위 방사선수술 시스템을 위한 자기공명영상의 공간적 왜곡의 측정 : 모형실험을 통한 연구)

  • 박선원;한문희;김동규;정현태;송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.7-13
    • /
    • 2000
  • Purpose : To assess the distortion of MRI with the Leksell stereotactic radiosurgery system in variable pulse sequence and imaging plane through phantom study, to find most adequate imaging plane and pulse sequence for stereotactic radiosurgery system. Materials and methods : We made the phantoms for MRI and get images in variable conditions and analyzed the image distortion using image analysis program, and statistically using paired student t-test. Results : The transeverse plane images had acceptable error ranges bless than 1.5mm) in all pulse sequence in both the analysis of fiducial marker in stereotactic G-frame and the phantom study. The coronal plane images had unacceptable large errors (more than 1.7mm) in the analysis of fiducial marker in the stereotactic G-frame, but had corrected small errors (less than 1.5mm) in the phantom study. Conclusion : We find from the phantom study that the present MR machines are adequate for stereotactic surgery system in frequently used pulse sequences, and imaging planes.

  • PDF

Relationship between the Lipid Accumulation Product Index and Alanine Aminotransferase in Korean Adult Men (한국 성인남성에서 Lipid Accumulation Product 지수와 Alanine Aminotransferase와의 관련성)

  • Shin, Kyung-A
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.374-381
    • /
    • 2017
  • The LAP (lipid accumulation product) index is an indicator of excessive fat accumulation in combination with the fasting triglyceride concentration and waist circumference. This study examined the relationship between the LAP index and ALT (alanine aminotransferase) level and the effect of the LAP index on the ALT level. Cross-sectional studies were conducted on healthy adult males without a history of liver disease. From January 2015 to June 2017, 13,854 adults between 20 and 70 years of age, who underwent health screening at a general hospital in Gyeonggi-do, were enrolled in this study. The LAP index was calculated as [waist circumference (cm)-65]${\times}$[triglyceride (mmol/L)] for males. Serum ALT abnormalities were set at 40 IU/L or more in males. All subjects underwent measurements of the anthropometric indicators and physiological examinations. A significant increase in ALT with increasing LAP quintiles was observed (p<0.001). The LAP index correlated with ALT (r=0.238, p<0.001). Insulin (r=0.449, p<0.001) and HDL-cholesterol (r=-0.369, p<0.001) were strongly correlated with LAP. In addition, the LAP index is a factor affecting the ALT level (p<0.001). As the LAP index increased, the risk of an elevated ALT was higher (p<0.001). In conclusion, the LAP index was a predictor of an ALT elevation in Korean men.

Change of Proton Bragg Peak by Variation of Material Thickness in Head Phantom using Geant4 (Geant4 전산모사를 이용한 두개골 팬텀의 물질 두께 변동에 따른 양성자 브래그 피크의 위치 변화)

  • Kim, You Me;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.401-408
    • /
    • 2021
  • Proton therapy using the Bragg peak is one of the radiation therapies and can deliver its maximum energy to the tumor with giving least energy for normal tissue. A cross-sectional image of the human body taken with the computed tomography (CT) has been used for radiation therapy planning. The HU values change according to the tube voltage, which lead to the change in the boundary and thickness of the anatomical structure on the CT image. This study examined the changes in the Bragg peak of the brain region according to the thickness variation in the head phantom composed of several materials using the Geant4. In the phantom composed of a single material, the Bragg peak according to the type of media and the incident energy of the proton beams were calculated, and the reliability of Geant4 code was verified by the Bragg peak. The variation of the peak in the brain region was examined when each thickness of the head phantom was changed. When the thickness of the soft tissue was changed, there was no change in the peak position, and for the skin the change in the peak was small. The change of the peak position was mainly changed when the bone thickness. In particular, when the bone was changed only or the bone was changed together with other tissues, the amount of change in the peak position was the same. It is considered that measurement of the accurate bone thickness in CT images is one of the key factors in depth-dose distribution of the radiation therapy planning.