• 제목/요약/키워드: 인체 측정치

Search Result 137, Processing Time 0.025 seconds

Comforts Evaluation of Car Seat Clothing (자동차 시트 표피재의 감성평가)

  • Kim, Joo-Yong;Lee, Chae-Jung;Kim, An-Na;Lee, Chang-Hwan
    • Science of Emotion and Sensibility
    • /
    • v.12 no.1
    • /
    • pp.77-86
    • /
    • 2009
  • A comfort evaluation of car seat clothing has been proposed for high comforts interior seat clothing. Car seat covers have received wide spread attention due to their man-machine interface working. And then, it will be necessary for measurements on delicate basic mechanical-properties, which closely relate with human touch feeling of its materials. In this research, we have utilized $KES-FB^{(R)}$(Kawabata Evaluation System) series, $^ST300{(R)}$ analogue softness tester and friction tester for measurement a physical properties. In order to consider both kansei and physical properties on interior seat covers, we firstly have established subjective words of judgement for the seat covers. Secondly, related them to the objective measurement of physical properties. Each kansei-language has clearly defined as 'Softness', 'Elasticity', 'Volume' and 'Stickiness' for the adjectives of leather car seat covers. These technical terms have correlated to physical properties in other words, h (mm), bending moment ($gf^*$cm/cm), To-Tm (mm) and ${\mu}$. At this time, fuzzy logic has utilized to predict the value of kansei language through physical values. On the basis of this result, finally it is possible to predict quality index of car seat covers using neural networks technique. In short, we develop a quality evaluation system of car seat clothing combining four physical quantities with kansei engineering.

  • PDF

Changes of IgM and IgG antibody levels in experimental rabbit anisakiasis as observed by ELISA and SDS-PAGE/immunoblot (ELISA와 SDS-PAGE/immunoblot을 이용한 실험적 토끼 아니사키스증에서 혈청 항체가의 변화)

  • Yang, Hyeon-Jong;Jo, Yu-Jeong;Baek, Yeong-Han
    • Parasites, Hosts and Diseases
    • /
    • v.29 no.4
    • /
    • pp.389-396
    • /
    • 1991
  • Antibody changes in experimental anisakiasis were observed in 10 rabbits which were infected each with 10 Anisakis simplex larvae. The sera were collected before and on the 6th to the 95th day after the infection. Using crude saline extract of Anisakis larvae as antigen, specific IgM and IgG antibody levels were observed by ELISA and SDS-polyacrylamide gel electrophoresislimmunoblot. Levels of specific-IgM antibody were elevated from the 6th day, reached their peaks on the lIth day after the infection, and dropped thereafter. Serum levels of IgG antibody increased from the 6th day and reached their peak on the 26th day after the infection, and decreased gradually thereafter. When SDS-PAGE of the crude extract was done, at least forty-one SDS-polypeptide bands were recognized. Of them, IgM antibody reacted mainly to the bands of 168, 95, 74, 64, 51, 47 and 34 kDa while IgG antibody reacted strongly to 168, 92, 85, 64, 58, 52, 42 and 40 kDa bands. The crude extract showed negligible cross reactions with sera of other parasitic diseases and normal control. Key words: Anisakis simplex larvae, experimental anisakiasis, rabbit, antibody, ELISA, SDS- PAGE/immunoblot.

  • PDF

Feasibility Study of Dose Evaluation of Stereotactic Radiosurgery using GafChromic $EBT^{(R)}$ Film (GafChromic $EBT^{(R)}$ 필름을 이용한 뇌정위방사선치료의 선량분석 가능성 평가)

  • Jang, Eun-Sung;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose: We have performed SRS (stereotactic radiosurgery) for avm (arterry vein malformation) and brain cancer. In order to verify dose and localization of SRS, dose distributions from TPS ($X-Knife^{(R)}$ 3.0, Radionics, USA) and GafChromic $EBT^{(R)}$ film in a head phantom were compared. Materials and Methods: In this study, head and neck region of conventional humanoid phantom was modified by substituting one of 2.5 cm slap with five 0.5 cm acrylic plates to stack the GafChromic $EBT^{(R)}$ film slice by slice with 5 mm intervals. Four films and five acrylic plates were cut along the contour of head phantom in axial plane. The head phantom was fixed with SRS head ring and adapted SRS localizer as same as real SRS procedure. CT images of the head phantom were acquired in 5 mm slice intervals as film interval. Five arc 6 MV photon beams using the SRS cone with 2 cm diameter were delivered 300 cGy to the target in the phantom. Ten small pieces of the film were exposed to 0, 50, 100, 200, 300, 400, 500, 600, 700, 800, 900 cGy, respectively to calibrate the GafChromic $EBT^{(R)}$ film. The films in the phantom were digitized after 24 hours and its linearity was calibrated. The pixel values of the film were converted to the dose and compared with the dose distribution from the TPS calculation. Results: Calibration curve for the GafChromic $EBT^{(R)}$ film was linear up to 900 cGy. The R2 value was better than 0.992. Discrepancy between calculated from $X-Knife^{(R)}$ 3.0 and measured dose distributions with the film was less than 5% through all slices. Conclusion: It was possible to evaluate every slice of humanoid phantom by stacking the GafChromic EBT film which is suitable for 2 dimensional dosimetry, It was found that film dosimetry using the GafChromic $EBT^{(R)}$ film is feasible for routine dosimetric QA of stereotactic radiosurgery.

  • PDF

Comparison of Intensity Modulated Radiation Therapy Dose Calculations with a PBC and AAA Algorithms in the Lung Cancer (폐암의 세기조절방사선치료에서 PBC 알고리즘과 AAA 알고리즘의 비교연구)

  • Oh, Se-An;Kang, Min-Kyu;Yea, Ji-Woon;Kim, Sung-Hoon;Kim, Ki-Hwan;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.48-53
    • /
    • 2012
  • The pencil beam convolution (PBC) algorithms in radiation treatment planning system have been widely used to calculate the radiation dose. A new photon dose calculation algorithm, referred to as the anisotropic analytical algorithm (AAA), was released for use by the Varian medical system. The aim of this paper was to investigate the difference in dose calculation between the AAA and PBC algorithm using the intensity modulated radiation therapy (IMRT) plan for lung cancer cases that were inhomogeneous in the low density. We quantitatively analyzed the differences in dose using the eclipse planning system (Varian Medical System, Palo Alto, CA) and I'mRT matirxx (IBA, Schwarzenbruck, Germany) equipment to compare the gamma evaluation. 11 patients with lung cancer at various sites were used in this study. We also used the TLD-100 (LiF) to measure the differences in dose between the calculated dose and measured dose in the Alderson Rando phantom. The maximum, mean, minimum dose for the normal tissue did not change significantly. But the volume of the PTV covered by the 95% isodose curve was decreased by 6% in the lung due to the difference in the algorithms. The difference dose between the calculated dose by the PBC algorithms and AAA algorithms and the measured dose with TLD-100 (LiF) in the Alderson Rando phantom was -4.6% and -2.7% respectively. Based on the results of this study, the treatment plan calculated using the AAA algorithms is more accurate in lung sites with a low density when compared to the treatment plan calculated using the PBC algorithms.

Radiation-Induced Chromosome Aberration in Human Peripheral Blood Lymphocytes In Vitro : RBE Study with Neutrons and $^{60}Co\;{\gamma}-rays$. (KCCH cyclotron neutron 및 $^{60}Co\;{\gamma}-ray$에 의한 인체 말초혈액 임파구의 염색체 이상측정)

  • Kim, Sung-Ho;Kim, Tae-Hwan;Chung, In-Yong;Cho, Chul-Koo;Koh, Kyoung-Hwan;Yoo, Seong-Yul
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.1
    • /
    • pp.21-30
    • /
    • 1992
  • The frequencies of KCCH cyclotron neutron (30 cGy/min) or $^{60}Co\;{\gamma}-rays$ (210 cGy/min)-induced asymmetrical interchanges (dicentrics and centric rings) and acentric fragments (deletion) at several doses were measured in the normal human peripheral blood lymphocytes Chromosome aberrations were scored at the first nitosis after stimulation with phytohemagglutinin. The neutron and y-ray data were analysed on linear, power-law, quadratic and linear-quadratic model . When the dicentrics and centric rings of ${\gamma}-rays$ datas were pooled and fitted to these model, good fits were obtained to power-law $[Y=(5.81{\pm}1.96){\times}10^6D^{1.93+0.06},\; P=0.931]$, quadratic $[Y=(3.91{\pm}0.09){\times}10^{-6}D^2,\;P=0.972]$ an linear-Quadrati model $[Y=(6.55{\pm}6.83){\times}10^{-5}D+(3.72{\pm}0.22){\times}10^{-6}D^2\; P=0.922]$, except for linear model (P=0.067) As in the case of neutron data, the best fit was obtained to the linear model $(Y=(6.12{\pm}0.17){\times}10^{-3}\;D-0.22,\;P=0.987]$ and good fits were obtained to power-law$[Y=(5.36{\pm}3.02) {\times}10^{-4}D^{1.42+0.11},\; P=0.601]$ and linear-quadratic model$[Y=(2.43{\pm}0.70){\times}10^{-3}D+(1.21{\pm}0.39){\times}10^{-7}D^2$, \;P=0.415], except for quadratic model (P<0.005). The relative biological effectiveness (RBE) of neutron compared with y-ray was estimated by best fitting model. In the asymmetrical interchanges range between 0.1 and 1.5 per cell, the RBE was found to be $2.714{\pm}0.408$.

  • PDF

Observation on Neck Form Changes Related to Aging in Men(Part I) -Using the Sliding Gause Measurement Method- (성인남자 목부위의 연령별 형태변화에 관한 연구(제1보) -슬라이딩 게이지법에 의한 분석-)

  • 이영숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.2
    • /
    • pp.252-262
    • /
    • 1994
  • As a means to get a better understanding of the kind of form changes to which is subject the neck of the men, in its aging process, several measurement recordings on a vertical and horizontal sections were carried. Subjects were young, middle aged and elder men (15 in their twenties, 11 in their forties and again 11 in their sixties) 1) The analysis of the meansurement results led us to distinguish 3 types of subjects according to the position of the their Adam's apple with regard to the horizontal plane containing their 7th cervical vertebrae point : clearly above (Type I), next to(Type II), clearly below(Type III). We found that young men correspond to the Type I and II, middle aged men to the Type ll and 111 and elder men only to the Type III. 2) The comparison of the horizontal sectional surface contained in the planes corresponding to the 4 points, shows a larger sectional surface for elder men in the Adam's apple plane, accompanied by a change of position of the Adam's apple forwards. As for the front neck point plane, the body sectiolial surface is larger in depth in elder men, without much change in breadth. And for the acromion point plane, we observed also an increase in depth, but with a decrease in breadth corresponding partially to the atrophy of the thoraric cage in eldermen.

  • PDF

Implementation and Evaluation of the LUTS Diagnosis System Using FPGA (FPGA를 이용한 LUTS 진단 시스템 구현 및 평가)

  • Jeong, Do-Un;Chung, Wan-Young;Jeon, Gye-Rock
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.6-14
    • /
    • 2007
  • The purpose of urodynamic investigation is to determine information on the function of the urinary system. One of the most frequently used measurement procedures in urodynamics is filling and voiding cystometry using invasive method. But in this method transurethral catheter is use and it makes patients uncomfortable. The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfortable method. Therefor in this study, a sensor and measuring system were implemented to measure uroflow, urophonography and noninvasive bladder pressure signal during urination for diagnosing the LUTS(lower urinary tract symptoms) using noninvasive method. The implemented system compose of the sensor parts, signal conditioning parts, system control parts using FPGA and PC monitoring program. For the evaluation of the implemented system, the simulation of system's control part was performed and the model system for the lower urinary system was designed. From the evaluation of the model system, the mean error rate of the uroflow measurement part was 1.08% and coefficient of variation was 1,48. And the mean error rate of the noninvasive bladder pressure measurement part was 2.41% and coefficient of variation was 2.81. urophongraphy signal analysis was accomplished in a time domain and frequency domain. Average RMS power was used in a time domain analysis, and MF was used in a frequency domain analysis. From the evaluation of the model system average RMS power and MF was dependent on the occlusion degree significantly and median frequency range of $60{\sim}160Hz$ was correlated with the occlusion.

  • PDF

A Study on the Distribution and Reduction Method of Indoor Radon Concentration in Daejeon Metropolitan City (대전광역시 주택 실내 라돈 농도 분포와 저감 공법 적용 연구)

  • Jang, Yong-Chul;Yang, Jae Hwan;Kim, Hongkyoung;Lee, Gain;Song, Hakyun;Kim, Byeonghwan;Kwon, Youngsun
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.5
    • /
    • pp.286-295
    • /
    • 2022
  • In this study, the concentration distribution of indoor radon in Daejeon Metropolitan City was investigated and the reduction efficiency was evaluated by applying the radon reduction methods. Based on the results of the National Institute of Environmental Research, indoor radon measurements were conducted on 24 selected houses, and the average value of District A was 261 Bq/m3, far exceeding the standard, and even in the same house, indoor radon concentration was affected by measurement point and time. In the case of eight houses that applied the soil venting method to reduce radon, the indoorradon level was significantly lowerthan the standard value, and the average reduction efficiency was also around 55%, indicating a good reduction effect. In addition, the average reduction efficiency was around 90% in the two houses that carried out the shielding method, showing the very excellent effect of the indoorradon reduction. Even if the same reduction method is applied when reducing radon, the reduction efficiency may vary depending on various factors such as the structure of the building, the frequency of ventilation, and the season, so it is necessary to accurately evaluate the effectiveness of the reduction method in the future. Based on this, it is necessary to establish indoor radon management measures in Daejeon Metropolitan City to reduce human harm caused by radon exposure.

Anthropometric Measurements of the Upper and Lower Body Balance and Exercise Habit among Female College Students in Some Parts of the Gyeongnam (경남 일부 지역 여자 대학생의 상하체 균형 계측치와 운동 습관)

  • Kim, Young-Sik;Yoon, Im-Sil;Lee, Won-Joon;Nam, Jeong-Su;Yoon, Joong-Soo;Youn, Ryea-Min;Jung, Han-Na;Ko, Jae-Shik;Choi, Hyun-Ju
    • Journal of Life Science
    • /
    • v.20 no.4
    • /
    • pp.535-542
    • /
    • 2010
  • This study was carried out to examine anthropometric parameters and related habits in female college students. Mean age, height, and body weight of the subjects in total (n=212) were 20.7 yrs, 161.8 cm, and 53.5 kg, respectively. Anthropometric parameters were measured by bioelectrical impedance analysis. Mean degree of obesity, body mass index (BMI), and waist-hip ratio (WHR) were 98.4%, $20.6\;kg/m^2$, and 0.80 respectively. Surprisingly, 63.7% of the subjects showed unbalanced weak upper bodies compared to their lower bodies. Therefore, they were divided into two groups: unbalanced weak upper body group (UU, n=135) and balanced upper body groups (BU, n=77). Bodyweight, degree of obesity, BMI, and WHR in the UU group were significantly lower than those in the BU group. Amounts of body protein, body fat, and body mineral in the UU group were also significantly lower than those of the BU group. Mid-arm muscle circumference of the UU group ($18.5{\pm}0.8\;cm$) was significantly lower than those of BU group ($20.4{\pm}1.2\;cm$), although mid-arm circumference of the UU group was not significantly different compared to those of the BU group. On a questionnaire on exercise habits, 1.5% of the UU group and 7.8% of the BU group answered that they exercised regularly, and 55.5% of the UU group and 31.2% of the BU group reported that they never exercised (p<0.01). Even in the subjects who exercised, the duration of the exercise was not sufficient because 38.4% of the UU group and 35.8% of the BU group answered that they exercised for less than 30 min. In conclusion, interventions in exercise habits may be needed for female college students who have unbalanced weak upper bodies.

Can the C-14 Urea Breath Test Reflect the Extent and Degree of Ongoing Helicobacter pylori Infection? (C-14 요소호기검사의 정량치가 Helicobacter pylori 감염 정도를 반영할 수 있을까?)

  • Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok;Lee, Soo-Teik;Jeong, Myoung-Ja
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.61-68
    • /
    • 2001
  • Purpose: The C-14 urea breath test (C-14 UBT) is the most specific noninvasive method to detect Helicobacter (H) pylori infection. We investigated if the C-14 UBT can reflect the presence and degree of H. pylori detected by gastroduodenoscopic biopsies (GBx). Materials and methods: One hundred fifty patients (M:F=83:67, age $48.6{\pm}11.2$ yrs) underwent C-14 UBT, rapid urease test (CLO test) and GBx on the same day. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (137 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive (${\geq}200dpm$), Intermediate ($50{\sim}199dpm$) or negative (<50 dpm). The results of CLO tests were classified as positive or negative according to color change. The results of GBx on giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT results with GBx grade as a gold standard. Results: In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.5%, 88.4%, 97.1%, 88.4% and 91.3%, respectively. However, the CLO test had sensitivity, specificity, PPV, NPV and accuracy of 83.2%, 81.4%, 91.8%, 81.4% and 82.7%, respectively. The quantitative values of the C-14 UBT were $45{\pm}27$ dpm in grade 0, $707{\pm}584dpm$ in grade 1, $1558{\pm}584dpm$ in grade 2, $1851{\pm}604dpm$ in grade 3, and $2719{\pm}892dpm$ in grade 4. A significant correlation (r=0.848, p<0.01) was found between C-14 UBT and the grade of distribution of H. pylori infection on GBx with giemsa stain. Conclusion: We conclude that the C-14 UBT is a highly accurate, simple and noninvasive method for the diagnosis of ongoing H. pylori infection and reflects the degree of bacterial distribution.

  • PDF