• Title/Summary/Keyword: 인체 스캔데이터

Search Result 52, Processing Time 0.025 seconds

Torso Pattern Design for Korean Middle-Aged Women using 3D Human Body Scan Data (차원 인체 스캔 데이터를 활용한 한국 중년여성 토르소 원형 설계)

  • Kim, Hye-Jin;Park, Soon-Jee
    • Fashion & Textile Research Journal
    • /
    • v.13 no.4
    • /
    • pp.600-613
    • /
    • 2011
  • The purpose of this study is to provide Torso pattern for Korean middle-aged women using 3D human body scan data. 155 women in their 40's or 50's were measured by Martin's anthropometry. Merging the data of 914 middle aged women provided by Korean agency for technology and standards, total of 1,069 subjects' data were analyzed. For data analysis, ANOVA, factor analysis and cluster analysis were done using SPSS PC+. And representative subject of each cluster was selected and they participated in 3D scanning and Torso pattern suggested for middle-aged women Torso pattern which investing the amount of ease according to each group for diffuse front interscye 30%, armscye circumference 30%, back interscye 40% using 3D human body scan data. The results of this study are as follows. Firstly, as a result of the factor analysis, the first factor was 'obesity index of body', The second factor was 'verticality size of body', The third factor was 'verticality length of upper bodice', The fourth factor was 'drop value to represent silhouette', and the fifth factor was 'physique of upper bodice'. And, middle-aged women type were classified 3 types according to the cluster analysis. Type 1(Y-type) was the long upper Torso with wide shoulder. Type 2(H-type) was flat-body type with comparatively thin upper bodice and thin lower bodice. And type 3(A-type) was the obese type with comparatively thin upper bodice and fat lower bodice. Secondly, using CAD program, point filtering was performed and approximated surface model was made. It used that generated surface smoothing corrected for abnormally extruded points and scattered points based on the curvature information. And 3D surfaces were flatted onto the plane by the internal tools of CAD program. Difference ratios of outline length and area between 3D curves and 2D plane were 0.42% and 0.54%, respectively. Third, wearing test by the sensory evaluation showed that distinct difference almost every category. The movement functionality test shows that, in all the tests which reveal significant differences, especially, 'comparison pattern A' experienced inconvenience to neck width and neck depth.

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF