• 제목/요약/키워드: 인체 스캔데이터

검색결과 52건 처리시간 0.035초

3차원 인체 스캔 데이터를 활용한 남성용 바디스 원형 설계 방법 연구 (Men′s Bodice Pattern Making Method using 3-D Body Scan Data)

  • 서동애;천종숙
    • 복식문화연구
    • /
    • 제12권2호
    • /
    • pp.290-299
    • /
    • 2004
  • The purpose of this study is to testify the pattern making method to develop the men's basic bodice pattern using 3-dimensional body scan data. The experimental patterns were made by adding wearing ease on flattened body scan data and tracing the outlines of it. The experimental bodice pattern were composed of front, back, and side panels. To compare the difference between the experimental pattern and traditional pattern, two pattern making methods were compared. Two sets of basic bodice patterns were made for each of the 10 male subjects: a set of pattern was made by experimental method and the other set was made by Bunka pattern making method. The experimental and traditional patterns were measured at 13 dimensions. The results show that there was a difference between the experimental patterns and traditional patterns at the front length, back length, front width, front neck width, back neck width, and back neck depth. The fit was also compared for both patterns. The results of the fit test show that the experimental patterns were superior to the traditional patterns at the fit of neck, shoulder, and armhole. The experimental pattern making method was expected to be useful for mass customization.

  • PDF

의류 패턴 설계를 위한 삼차원 인체 체표면 스캔 데이터 활용에 관한 연구 (A Study on the Use of 3D Human Body Surface Shape Scan Data for Apparel Pattern Making)

  • 천종숙;서동애;이관석
    • 복식문화연구
    • /
    • 제10권6호
    • /
    • pp.709-717
    • /
    • 2002
  • In the apparel industry, the technology has been advanced rapidly. The use of 3D scanning systems fur the capture and measurement of human body is becoming common place. Three dimensional digital image can be used for design, inspection, reproduction of physical objects. The purpose of this study is to develop a method that drafts men's basic bodice pattern from scanned 3D body surface shape data. In order to pursue this purpose the researchers developed pattern drafting algorithm. The 3D scanner used in this study was Cyberware Whole Body Scanner WB-4. The bodice pattern drafting algorithm from 3D body surface shape data developed in this study is as follows. First, convert geometric 3D body surface data to 3D polygonal mesh data. Second, develop algorithm to lay out 3D polygonal patches onto a plane using Auto Lisp program. The polygon meshes are coplanar, and the individual mesh is continuously in contact with next one The bodice front surface shape data in polygonal patches form was lined up in bust and waist levels. The back bodice was drafted by lining up the polygonal mesh in scapula, chest, and waist levels. in the drafts, gaps between polygons were formed into the darts.

  • PDF

상하의 의류 영상을 이용한 가상 의류 착의 시스템 (A Virtual Fitting System Using The Top and Bottom Image of Garment)

  • 최란;조창석
    • 한국멀티미디어학회논문지
    • /
    • 제15권7호
    • /
    • pp.941-950
    • /
    • 2012
  • 본 연구에서는 PC상에서 인체 3차원 데이터에 상하의 의류를 중첩 착의하는 가상 착의 시스템을 소개한다. 이를 위하여, 레이저 스캔 방식으로 얻은 인체 3차원 데이터와 의류 앞뒷면의 모습을 촬영하여 얻은 의류 디지털 데이터를 이용한다. 2차원의 앞뒷면 의류 디지털 데이터에는 의류 소재 내 질점 간의 장력이 반영되었고, 인체 데이터에의 착의 과정에는 마찰력과 중력을 적용해 주었다. 하의 착용 시에는 마찰력과 중력에 추가적으로 혁대 개념을 도입하여 흘러내리는 의류를 고정하였고, 하의를 착의한 인체데이터위에 상의를 착의하는 중첩 착의 방법을 제시하였다. 본 시스템이 지닌 장점은 복잡한 패턴을 이용하여 착의하는 다른 연구와 달리, 의류의 앞뒷면만을 이용하여 착의하면서도 현실감은 뒤지지 않는다는 것에 있다. 현재 의류전자상거래 시 의류의 앞뒷면만을 전시하여 판매하는 방법과 유사한 방식으로 온라인 판매가 이루어지나, 착의 모습을 제공할 수 없는 기존 방식과 달리 3차원의 착의 모습까지 제공하게 되어, 의류 판매의 방식을 바꾸게 할 것으로 기대한다.

3차원 인체형상 스캔데이터를 이용한 남자 바지패턴 설계 (Development of Men Slacks Pattern Using 3D Scan Data)

  • 손부현
    • 대한가정학회지
    • /
    • 제46권9호
    • /
    • pp.137-146
    • /
    • 2008
  • This study was conducted in order to spread out lower body 3D scan data of men in their twenties. The aim was to achieve slacks pattern with ease allowance through comparison with existing flat patterns. For conversion of 3D scan data into 20 pattern, reference lines were established by using Rapid Foam in 3D shape analysis software. 2C-AN program and Yuka CAD were used to convert 20 pattern earned with straight posture of 3D scan data into slacks pattern by using Triangle Simplification & Runge-Kutta Method. In order to achieve this we needed to set a line 9cm below the hip line, to array vertex of each block to crease line while maintaining the horizontal line. And then we needed to set ease allowance in back crotch and to set waist circumference or hip circumference ease allowance in side seam of slacks. Results showed that long front crotch length can be achieved if 3D scan data is compared with 20 existing flat pattern. Slacks pattern that raise front crotch by about 1.5cm compared to back crotch and also possess ease allowance in back crotch area are great in appearance evaluation.

3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 - (The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner -)

  • 박선미;남윤자
    • 한국의상디자인학회지
    • /
    • 제14권1호
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

인체의 3차원 스캔 데이터를 이용한 밀착 바디 슈트 개발 (2D Pattern Development of Tight-fitting Bodysuit from 3D Body Scan Data for Comfortable Pressure Sensation)

  • 정연희
    • 한국생활과학회지
    • /
    • 제15권3호
    • /
    • pp.481-490
    • /
    • 2006
  • Adjusting pressure level in the construction of athletes' tight-fitting garments by reducing the elastic knit pattern is a challenging subject, which influences the performance of the wearer directly. Therefore, in this study, relationship between the reduction rates of the basic pattern obtained from 3D human scan data and resultant clothing pressure was explored to improve the fit and pressure exerted by clothing. 3D scan data were obtained using Cyberware and they were transformed into a flat pattern using software based on Runge-Kutta method. Reduction rate was examined by subjective wear test as well as objective pressure measurement. As a result, difference in the length between the original 3D body scan data and the 2D tight-fitting pattern was 0.02$\sim$0.50cm (0.05$\sim$1.06%), which was within the range of tolerable limits in making clothes. Among the five garments, the 3T-pattern was superior in terms of subjective sensation and fit. The pressure of the 3T pattern was 2$\sim$4 gf/cm2 at five locations on the body, which is almost the same or a bit higher than that of Z-pattern. In the case of tight-fitting overall garment, the reduction rate of the pattern in the wale direction is more critical to the subjective sensation than the course direction. It is recommended that the reduction grading rules of course direction should be larger than that of Ziegert for a better fit of tight-fitting garments. In the case of wale direction, however, reduction grading rule should be kept the same as suggested earlier by Ziegert (1988).

  • PDF

3차원 데이터에 의한 여고생의 발 형태에 관한 연구 (A Study on Foot Shape by 3D Data of Female High School Students)

  • 이정은;도월희
    • 한국의류학회지
    • /
    • 제38권4호
    • /
    • pp.572-583
    • /
    • 2014
  • This study analyzes the foot shape of female high school students using 3D foot scan data based on a comparison with adult women (20s'-30s'). Data were collected from the foot anthropometry of 199 female high school students in Gwangju and Jeollanam-do. The right foot was measured indirectly by 3D laser scanner. There are 16 items in the foot anthropometric measurements. The $6^{th}$ Size Korea (measured by 3D scan data) is used for women's foot data. The results of the 3D measurements data investigation show that the foot length and foot width became longer and wider as the age increased. It is classified by three types after analyzing foot shape. Type 1 (28.1%) represented the shortest foot length, the narrowest foot width as well as the thick foot and long ankle shape. Type 2 (4.3%) represented the wide foot width such as the wide lateral ball width and semi-thickness shape. Type 3 (67.7%) referred to the widest foot width, flat foot and short ankle shape.

엔도크라운 디지털 인상을 위한 구강스캐너 3종의 정확도 평가: 실험실 연구 (Evaluation of the accuracy of three different intraoral scanners for endocrown digital impression: An in vitro study)

  • ;박지만
    • 대한치과보철학회지
    • /
    • 제58권4호
    • /
    • pp.282-289
    • /
    • 2020
  • 목적:본 연구의 목표는 다른 유형의 엔도크라운(endocrown) 와동 형태를 세 가지 다른 구강스캐너로 디지털 인상을 채득하였을 때의 정확성을 평가하는 것이다. 재료 및 방법: 두 개의 인체 하악 대구치를 협측벽이 있는 것(Class 2)과 협측벽이 없는(Class 3), 두 가지 엔도크라운 지대주 디자인으로 치아형성 하였다. 와동 디자인 2종을 레퍼런스로 탁상용 스캐너(E3, 3shape)와 세 개의 다른 구강스캐너, Trios 3 (3shape, TRI group), Cerec Omnicam (Dentsply Sirona, CER group), i500 (Medit Corp., I5 group)로 스캔하였다. 표준 테셀레이션 언어(.stl) 데이터 세트를 얻어, 계측 소프트웨어에서 불러들였다. 각 구강스캐너로 획득한 반복된 스캔 데이터 사이의 편차에 기초하여 정밀도(precision)를 평가하였다. 기준 데이터와 반복하여 얻은 구강스캔 사이의 편차로서 진도(trueness)를 평가 하였다. 상호작용을 탐지하기 위해 데이터는 일변량 분산분석(ANOVA)을 사용하여 통계적으로 분석하였고, 실험군의 비교 분석을 위해 데이터는 .05의 유의 수준에서 일원 분산분석 및 사후 Tukey 테스트로 분석하였다. 결과: I5 군의 두 와동 형태에 대한 편차값은 진도의 측면에서 다른 구강스캐너 군에 비해 낮았다. 두 와동 디자인 모두에서 TRI 군은 다른 구강스캐너군 보다 우수한 정밀도를 보였다. 결론: 구강스캐너의 다양한 기술과 다양한 엔도크라운 치아형성 디자인이 디지털 스캔의 정확도에 영향을 미쳤다.

3차원 스캔을 활용한 상체 피부표면의 Non-extension line 분석 (Analysis of non-extension line on upper body using 3D scanning)

  • 최지영;오염군;홍경희;서혜원;김시조
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2009년도 춘계학술대회
    • /
    • pp.239-242
    • /
    • 2009
  • 최근 3 차원 측정 기술을 활용한 운동 기능성의 향상을 위한 연구가 활발히 진행되고 있다. 그 예로 3 차원 인체 정보를 이용한 의복패턴 제작 시에 필요한 절개선으로 피부상에서 동작 시 늘어나지 않는 선(Lines of Non-Extension, LoNE)을 찾아내어 활용한 연구가 발표된 바 있다. 이러한 LoNE 은 기존 의복구성을 위한 봉제선이나 기능선으로 활용될 때 동작기능성을 저해하지 않는 특징이 있다. 이에 본 연구에서는 스포츠웨어에서 활동성이 큰 상체의 어깨부위에서 Lines of Non-Extension 을 탐색하고자 하였다. 연구 방법으로는 20 대 후반 남성 2 명을 대상으로 체표의 등 부분에서 3cm 간격으로 계측점을 표시한 후 3D 인체 데이터 (Cyberware, WB)를 획득하였다. 측정시의 자세는 팔을 $30^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$ 외전시켰다. 피부 표면에서의 길이 변화는 구획의 크기를 달리하면서 가로, 세로, 사선방향으로 동작에 따라서 측정하였다. 변화량은 정자세($30^{\circ}$)를 기준으로 A 라 하였을 때, 기준자세와의 차이가 가장 큰 변화량을 보인 자세를 B 라 하고 A 와 B 간의 차이로 계산하였다. 연구결과, NASA 의 Biosuit 에서 소개된 Iberall(1970)의 LoNE 중 진동둘레를 포함한 팔 부위와 등, 어깨 부위에서 유사한 라인을 찾았다. 본 연구에서와 같이 구획별 사선방향 피부 변화량을 측정하는 것은 피부면에 숨겨진 인간공학적 의복 기능선을 탐색하는 데 효과적임을 확인하였다.

  • PDF