Evaluation of Target Position's Accuracy in 2D-3D Matching using Rando Phantom (인체팬톰을 이용한 2D-3D 정합시 타켓위치의 정확성 평가)

  • Jang, Eun-Sung;Kang, Soo-Man;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • Purpose: The aim of this study is to compare patient's body posture and its position at the time of simulation with one at the treatment room using On-board Imaging (OBI) and CT (CBCT). The detected offsets are compared with position errors of Rando Phantom that are practically applied. After that, Rando Phantom's position is selected by moving couch based on detected deviations. In addition, the errors between real measured values of Rando Phantom position and theoretical ones is compared. And we will evaluate target position's accuracy of KV X-ray imaging's 2D and CBCT's 3D one. Materials and Methods: Using the Rando Phantom (Alderson Research Laboratories Inc. Stanford. CT, USA) which simulated human body's internal structure, we will set up Rando Phantom on the treatment couch after implementing simulation and RTP according to the same ways as the real radioactive treatment. We tested Rando Phantom that are assumed to have accurate position with different 3 methods. We measured setup errors on the axis of X, Y and Z, and got mean standard deviation errors by repeating tests 10 times on each tests. Results: The difference between mean detection error and standard deviation are as follows; lateral 0.4+/-0.3 mm, longitudinal 0.6+/-0.5 mm, vertical 0.4+/-0.2 mm which all within 0~10 mm. The couch shift variable after positioning that are comparable to residual errors are 0.3+/-0.1, 0.5+/-0.1, and 0.3+/-0.1 mm. The mean detection errors by longitudinal shift between 20~40 mm are 0.4+/-0.3 in lateral, 0.6+/-0.5 in longitudinal, 0.5+/-0.3 in vertical direction. The detection errors are all within range of 0.3~0.5 mm. Residual errors are within 0.2~0.5 mm. Each values are mean values based on 3 tests. Conclusion: Phantom is based on treatment couch shift and error within the average 5mm can be gained by the diminution detected by image registration based on OBI and CBCT. Therefore, the selection of target position which depends on OBI and CBCT could be considered as useful.

  • PDF

고선량율 근접치료에서 기존의 필름 방법과 CT 재구성 방법의 정확성 비교 연구

  • 장지나;서태석;허순녕;윤세철;김회남;이형구;최보영
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.58-58
    • /
    • 2003
  • 목적 : 본 연구에서는 C-arm과 CT에 사용 가능한 자궁경부암용 팬톰을 개발하고 이를 이용하여 기존의 필름 방법에 기반한 위치 확인 방법과 CT 재구성 방법의 정확성을 비교 연구하고자 한다. 정확성이 검증된 후에는 두 방법의 장점을 이용하기 위해 CT로 재구성된 좌표를 필름의 좌표로 변환시켜 현재 사용되고 있는 필름에 기반한 근접 치료 계획 시행에 도움을 주고자 한다. 방법 : 자체 제작한 자궁경부암용 팬톰은 인체 등가 물질인 물과 아크릴을 사용하였고, 크게 localizer 부분과 팬톰 부분으로 구성되어 있다. 또한, 실제 자궁경부암 환자의 임상적인 구조를 모사하여 제작하였다. 자궁경부암 치료시 중요 장기인 방광과 직장을 구와 원기둥으로 설계하였고, 고선량율 applicator는 아크릴 판의 흠으로 고정시켜 제작하였기 때문에 CT 촬영시 applicator를 제거한 영상에서도 applicator의 구조가 정확하게 묘사될 수 있도록 제작하였다. 두 시스템에서 재구성된 좌표를 비교하기 위해 각각의 시스템에서의 얻은 재구성 좌표와 팬톰 자체의 localizer와 재구성 알고리즘을 바탕으로 개발된 프로그램을 이용하여 얻은 좌표로 두 재구성 좌표의 비교 연구를 수행하였다. 정확성이 검증되고 장기의 정보가 담긴 CT의 좌표는 자체 개발된 프로그램으로 2 차원의 필름 좌표로 변환되었다. 본 연구에 사용된 모든 프로그램은 ILD 5.5를 사용하여 개발되었다. 결과 : 두 시스템의 좌표 비교 결과 x, y 축은 차이가 2mm 이내로 비교적 정확한 실험 결과를 얻을 수 있었고, z 축의 경우 CT 슬라이드의 굵기에 따라 2mm-3mm 이내의 차이가 있음을 관찰할 수 있었다. z 축을 제외한 좌표의 차이는 획득한 영상에서 컴퓨터로 좌표를 옮기는 localizer 좌표 선택 과정에 발생했을 것으로 예상된다. 또한, 이 검증된 좌표와 개발된 프로그램을 이용하여 우리는 CT의 좌표를 2차원의 필름 좌표로 정확하게 변환할 수 있었다. 결론 : 이 연구로부터 기존의 C-arm 재구성 방법과 CT 재구성 방법의 비교를 통해 각 치료 기기의 신뢰성을 직접 확인할 수 있었으며, 비교를 통해 검증된 CT의 좌표를 필름 좌표로 변환시킴으로서, 각 시스템의 장점만을 결합한 효과적인 치료 계획을 세울 수 있는 가능성을 제시하였다. 또한 물과 아크릴을 사용한 비교적 간단하고 경제적인 방법으로 C-arm, CT 그리고 MRI에 모두 이용 가능한 팬톰을 제작하여 쉽고 정확하게 위치를 확인할 수 있었다. 더 나아가, 본 연구에서 제작된 자궁경부암 팬톰은 근접치료를 포함하여 관련 팬톰 개발에 도움을 줄 수 있을 것으로 예상된다.

  • PDF

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

A Study of Radiographic Methods to X-ray Study of Patients with Spinal Scoliosis and Vertebrae Bone Fracture of Lumbar Spine (척주측만증과 허리뼈 골절 수술 환자의 엑스선 촬영법 연구)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.425-431
    • /
    • 2019
  • The Study In order to obtain images of overlap of the two iron cores in the spinal cord simple x-ray scan after surgery of patients with ulcer lateral sclerosis and a fractured backbone, the researcher conducted a subjective evaluation on five radiographers of the university hospital's imaging department for more than 10 years. The results of the experiment showed that the lateral shot of lateral scoliosis of the spinal cord was taken with the middle face of the IR plane, and then the X-ray tube angle was taken vertically with the vertical spinal column fan-tom position, resulting in two overlapping images and high scores in the subjective evaluation. In addition, lateral shots of the lumbar dislocation fractured lumbar vertebrae were taken with the forehead aligned with the center of the IR plane and then with the X-ray angle perpendicular to the fourth waistline and the angle of the spinal cord perpendicular to the fourth waistline, the image of the two iron cores could be obtained from the radiographer.

Comparison of Linac-based VMAT Stereotatic Radiosurgery and Conventional Stereotatic Radiosurgery for Multiple Brain Lesions (Linac 기반 VMAT 정위적 수술 뇌 병변 연구와 기존의 정위적 방사선 수술 비교)

  • Jang, Eun-Sung;Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.239-246
    • /
    • 2021
  • Portal Dosimetry was verified using EPID to secure the clinical application and reliability of the existing research dose evaluation. The dose distribution of Geant4 was compared with the measured value by 360° rotational irradiation with a 2.5 cm cone for stereotactic brain surgery. To confirm the dose distribution of patients with brain metastasis, the dose distribution investigated by inserting a Gafchromic EBT film into the parietal phantom and the dose distribution obtained from the parietal phantom using VMAT are compared and applied to actual patients. As a result of the analysis, it was confirmed that the accuracy of the beam center and the center of the couch coincide accurately with an error within 1mm as a result of QA through a pin ball. In addition, it was confirmed that the EBT3 film has excellent linearity in the range of 0 to 10 Gy according to various dose irradiation. In the same setting as the two cervical phantoms, we confirm that the implementation and simulation results calculations of dose calculations based on Geant4 using photon beams match the experimental data within the treatment planning volume (PTV). Therefore, volume modulated arc treatment (VMAT) 360° rotational irradiation was performed, and the result of iso-dose distribution analysis by rotational irradiation confirmed that it is appropriate to include a virtual tumor.

Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy (자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2003
  • High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a phantom. In this study, the phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the phantom were then compared with the treatment planning system for the dose verification. The phantom needs to be designed such that the dose distributions can be quantitatively evaluated by utilizing the dosimeters with a high spatial resolution. Therefore, the small size of the thermoluminescent dosimeter (TLD) chips with a dimension of <1/8"and film dosimetry with a spatial resolution of <1mm used to measure the radiation dosages in the phantom. The phantom called a pelvic phantom was made from water and the tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators were inserted into the grooves of the applicator holder. The dose distributions around the applicators, such as Point A and B, were measured by placing a series of TLD chips (TLD-to-TLD distance: 5mm) in the three TLD holders, and placing three verification films in the orthogonal planes. This study used a Nucletron Plato treatment planning system and a Microselectron Ir-192 source unit. The results showed good agreement between the treatment plan and measurement. The comparisons of the absolute dose showed agreement within $\pm$4.0 % of the dose at point A and B, and the bladder and rectum point. In addition, the relative dose distributions by film dosimetry and those calculated by the planning computer show good agreement. This pelvic phantom could be a useful to verify the dose calculation algorithm and the accuracy of the image localization algorithm in the high dose rate (HDR) planning computer. The dose verification with film dosimetry and TLD as quality assurance (QA) tools are currently being undertaken in the Catholic University, Seoul, Korea.

  • PDF

Evaluation of Dose Distribution Using Gafchromic $EBT^{(R)}$ Film (Gafchromic $EBT^{(R)}$ 필름을 이용한 선량분포의 평가)

  • Kang, Se-Sik;Ko, Seong-Jin;Jang, Eun-Sung
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.139-145
    • /
    • 2007
  • Dose evaluation for small field such as stereotactic radiosurgery was performed using $Gafchromic^{(R)}$ EBT film. Every film which irradiated 6MV photon beam was scanned and obtained the optical density(OD) by flat bed scanner after 24 hours of irradiation. This study compared dose from diode in water and Gafchromic $EBT^{(R)}$ film in acrylic phantom to verify the reliability of the film, and to evaluate the SRS in clinical dose distributions from calculation and measurement in the region of virtual target in humanoid and cylindrical phantoms were compared. The Gafchromic $EBT^{(R)}$ film was found to be linear up to 9Gy. The $D_{max}$ for 6 MV was measured at 1.5 cm from the surface by both of diode and the film. As the depth is deeper, the error was measured within $2{\sim}3%$ at $10{\sim}20\;cm$ depth. Comparing between distribution from calculation and measurement, we found that there is 5% error at 90% isodose line. We found that given dose could be measured accurately by using the phantoms. It was feasible to use the Gafchromic $EBT^{(R)}$ film in quality assurance of SRS.

  • PDF

고체 팬톰을 이용한 방사선치료계획시스템의 정도관리

  • 이상훈;조광환;조삼주;최진호;추성실;권수일;신동오
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.65-65
    • /
    • 2003
  • 목적 : 방사선치료기술이 날로 발전함에 따라 방사선치료계획시스템에 대한 주기적인 정도관리의 필요성은 증대하고 있으나, 국내 실정에 적합한 표준화된 정도관리절차서가 없는 실정이다. 따라서 본 연구에서는 방사선치료계획용 시스템에 대한 정도관리용 고체팬톰을 제작하여 주기적인 정도관리 활용 및 절차서를 제시하고자 한다. 대상 및 방법 : 체윤곽 보정을 위한 삼각기둥 모형 (30cm$\times$30cm$\times$5cm, 30cm$\times$15cm$\times$5$\times$) 및 정형ㆍ부정형, 불균질 측정이 가능한 물등가고체팬톰을 제작하였고, 컴퓨터단층촬영(AcQsim)을 통해 영상을 얻었으며, RTPS(AcQplan)에 입력하여 영상 내 기준점에서의 선량값을 계산하였다. RTPS를 통해 계산된 값의 평가를 위해 동일한 조건하에서 각 기준점에 대한 실제 측정을 이온함을 이용하여 측정하였다. 평가 항목으로는 정방형 조사면, 부정형 조사면, 쐐기 조사면, 불균질 물질 보정, 사방향 조사 등에 대해서 알고리즘별로 수행하였다. 결과 : RTPS를 이용하여 계산된 값과 실제 측정한 값을 비교하여 RTPS의 정확성을 평가한 결과로 합성의 불확도 허용 기준 (3%), 선속 중심축 상에서의 허용 기준 (2%) 등, 선진 각국 및 각 학회에서 권고하고 있는 허용 범위 내에서 잘 일치하였다. 결론 : RTPS는 측정된 심부선량과 선량분포 등 물리적인 인자에 의존하는 제한성이 있고, 실제로 선량계산 알고리즘과 기하학적 변화에 따라 계산값과 측정값 간에 차이가 발생할 수 있었다. 실제 인체의 체윤곽 불균일성과 불균질성을 모사한 팬톰을 제작하여 이용함으로써 다양한 RTPS간의 비교를 통한 치료 선량의 정확성을 평가하고, 방사선 치료의 원활하고 정확한 수행을 위해 실용적이고, 보편적인 치료계획 시스템의 정도관리 방법과 절차서를 수립하는데에 유용할 것으로 사료된다.

  • PDF

Impact of Computed Tomography Slice Thickness on Intensity Modulated Radiation Therapy Plan (전산화단층촬영 슬라이스 두께가 세기변조방사선치료계획에 미치는 영향)

  • Lee, Seoung-Jun;Kim, Jae-Chul
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.285-293
    • /
    • 2006
  • $\underline{Purpose}$: This study was to search the optimal slice thickness of computed tomography (CT) in an intensity modulated radiation therapy plan through changing the slice thickness and comparing the change of the calculated absorbed dose with measured absorbed dose. $\underline{Materials\;and\;Methods}$: An intensity modulated radiation therapy plan for a head and neck cancer patient was done, first of all. Then CT with various ranges of slice thickness ($0.125{\sim}1.0\;cm$) for a head and neck anthropomorphic phantom was done and the images were reconstructed. The plan parameters obtained from the plan of the head and neck cancer patient was applied into the reconstructed images of the phantom and then absorbed doses were calculated. Films were inserted into the phantom, and irradiated with 6 MV X-ray with the same beam data obtained from the head and neck cancer patient. Films were then scanned and isodoses were measured with the use of film measurement software and were compared with the calculated isodeses. $\underline{Results}$: As the slice thickness of CT decreased, the volume of the phantom and the maximum absorbed dose increased. As the slice thickness of CT changed from 0.125 to 1.0 cm, the maximum absorbed dose changed ${\sim}5%$. The difference between the measured and calculated volume of the phantom was small ($3.7{\sim}3.8%$) when the slice thickness of CT was 0.25 cm or less. The difference between the measured and calculated dose was small ($0.35{\sim}1.40%$) when the slice thickness of CT was 0.25 cm or less. $\underline{Conclusion}$: Because the difference between the measured and calculated dose in a head and neck phantom was small and the difference between the measured and calculated volume was small when the slice thickness of CT was 0.25 cm or less, we suggest that the slice thickness of CT should be 0.25 cm or less for an optimal intensity modulated radiation therapy plan.

Analysis of Radiation Dose for Lens, Thyroid Gland, Breast, and Gonad on Upper Gastrointestinal Series (위장조영검사에서 수정체, 갑상선, 유방, 생식선에 대한 피폭선량 분석)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.889-894
    • /
    • 2019
  • Upper gastrointestinal series is an examination that uses X-rays. It is important to defend against exposure to radiation during upper gastrointestinal examination because the organs, such as thyroid gland, lens, breasts, and gonads, with relatively high biological sensitivity to radiation are distributed on the examination area. We have made a whole body phantom that can change the depth of organs. radiation dose of eye, thyroid gland, breast and gonads were measured by the same procedure as the actual upper gastrointestinal examination. When performed only fluoroscopy the mean dose reduction of lens, thyroid gland, breast and gonads was 62.2%. The mean dose reduction of lens, thyroid gland, breast and gonads was 59.0% when both fluoroscopy and spot shoot were performed. Therefore, when performed upper gastrointestinal examination it was confirmed that shielding of the lens, thyroid gland, breast and gonads was effective in decreasing the exposure dose. The manufactured human phantom can be used in measuring radiation dose for deep organ because it can adjust the height corresponding to the organs located in the human body.