• Title/Summary/Keyword: 인발상관계수

Search Result 4, Processing Time 0.023 seconds

Evaluation of Geogrid-Reinforced Track substructure Effectiveness Using A Large-Scale Pullout Device (대형인발시험기를 이용한 지오그리드로 보강된 궤도하부구조층의 효율성 평가)

  • Oh, Jeongho
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.1
    • /
    • pp.40-48
    • /
    • 2014
  • A number of attempts has been made to reinforce ballasted track substructure to meet the requirement of high-speed operation and effective rehabilitation of existing railroads. For the purpose of this, the use of geogrid has been applied, and the benefit of its use has been recognized via previous studies. In this study, an experimental pullout test was carried out to investigate the influence of normal stress on pullout strength of geogrid using different types of soil and geogrid. The results revealed that the pullout resistance generally tends to increase proportional to normal stress while the pullout coefficient interaction decreases, which is a function of material interface properties, such as the friction angle of soil, and interlocking condition between soil and geogrid. In addition, a methodology based on work-energy concept was proposed to evaluate effectiveness of geogrid and limitedly verified using test results.

Numerical Analysis for the Pullout Behavior and Failure Mechanism of Ground Anchor (그라운드 앵커의 인발거동 및 파괴메카니즘에 대한 수치해석)

  • Park, Byung-Soo;Shim, Do-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.2
    • /
    • pp.69-76
    • /
    • 2010
  • This study is an numerical study of predicting the behavior of anchor embedded in weathered rocks, subjected to uplift loads, about ultimate pullout capacity and the failure mechanism. Factors influencing the behavior of anchors were investigated by reviewing the data about in-situ anchor tests performing numerical modelling with changing the bondage length of anchor, diameter of anchor body and diameter of tendon, and by correlations between those factors were evaluated to apply them to predict the behavior of anchors. As results of numerical analysis, a linear relationship between bondage length, diameter of anchor body and diameter of tendon with ultimate pullout capacity was obtained on the one hand, from the result of numerical analysis changing the Young's modulus of weathered rock, this parameter was found to influence to load-displacement and ultimate pullout capacity within the range of 10%, which was not so significant to affect.

Design Evaluation of the Post-installed Anchor considering Effective Embedded Depth and Concrete Strength (유효 묻힘 깊이와 콘크리트 강도를 고려한 후설치 앵커의 설계식 평가)

  • Hur, Moo-Won;Chae, Kyoung-Hun;Won, Jae-Sik;Park, Tae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.3
    • /
    • pp.13-20
    • /
    • 2021
  • Post-installed anchor is a structural material that connects structural and non-structural members to existing concrete members. However, there are cases where rebar interception and construction error occur at the site. In that case, measures are needed to prevent performance degradation of the rear-installation anchors. In this study, in order to evaluate the performance of torsional control expandable post-installed anchors for compressive strength and effective depth of the reference concrete was tested. The results of the most commonly used tests of M10 and M20 showed that had variable coefficients within 15%, satisfying the reliability presented in KCI(2017). It was also confirmed that the depth of the buried and the strength of concrete affect the strength of the pavement. Based on the results of the existing similar studies and the results of this study, the design equation of the post-installed anchor was proposed and the results were compared with the existing design.

The Application of a Simplified Pullout Test for High-Strength Concrete (고강도 콘크리트에 대한 간이 인발시험법 적용)

  • Ko, Hune-Bum;Jeon, Doo-Jin;Lee, Min-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.49-55
    • /
    • 2017
  • In the seventies, a number of researchers carried out experiments on pullout tests with prototype equipment, and the pullout test was certified as a reliable nondestructive testing(NDT) method for determining the strength of concrete. To estimate the strength of high-strength concrete, we propose a simplified pullout test that uses as a break-off bolt a standard 10mm bolt with a groove on the shaft, an insert nut, and a pullout instrument that includes a hydraulic oil pump without a load cell. To verify the advantages of the simplified pullout test(low cost, simplicity, and convenience), four wall specimens were tested with two levels of concrete strength, 30 MPa and 50 MPa, using a simplified pullout tester with a load cell. The pullout load and concrete compressive strength were measured every day until day 7, day 14, day 21 and day 28. It was found that the pullout load was very similar to the compressive strength. Therefore, we have verified that a simplified pullout test can be used to evaluate the in-place strength of high-strength concrete in structures. The prediction equation of the groove diameter of the break-off bolt(y) with the concrete strength(x) was derived as y=0.05x+3.79, with a coefficient of determination of 0.88 found through regression analysis.