A evaluation study of a fire smoke diffusion delay device installed in a great depth underground double deck tunnel (대심도 복층터널에 설치 가능한 화재연기 확산지연장치 성능 평가 연구)

  • Shin, Tae-Gyun;Moon, Jung-Joo;Yang, Yong-Won;Lee, Yun-Taek
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.225-234
    • /
    • 2018
  • Domestic urban areas are experiencing serious traffic congestion problems due to continuous population growth and increased traffic volume. In order to solve the problem of traffic congestion, the study of great depth underground double deck tunnels using underground space is being actively carried out in the urban areas. The characteristics of great depth underground double deck tunnels are low in cross section, so the spread of fire smoke is expected to spread faster than the road tunnel in case of fire. Therefore, it is necessary to provide a fire smoke delay device which delays the spread of fire smoke when a fire occurs in a tunnels. In the previous study, the diffusion effect was analyzed according to the blocking area when the fire smoke spread delay device was operated through the 3D CFD in the study of preventing the smoke spread in the case of the tunnel fire. A study on fire smoke diffusion delay device using spring elasticity which is excellent in applicability to a tunnel and economical value is studied. In this study, fire smoke spread delay system was developed to fire smoke delay was experimentally analyzed. Fire smoke delay effect of fire smoke delay device appeared. Therefore, it is considered that the can minimize the damage of the victims when installed in the great depth underground double deck tunnels.

Effects on Resident of human body at fire outbreak for apartment building using CFAST (화재 시뮬레이션을 이용한 공동주택 화재발생시 거주자의 인체에 미치는 영향)

  • Park, Joo-Won;Kwon, Jin-Suk;Choi, Jae-Hyouk
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.189-189
    • /
    • 2011
  • 최근 공동주택은 보편적인 도시주거 유형으로 자리매김 하고 있지만, 성장 위주의 경제 산업 정책에 따른 안전의식미약, 사회구조개편에 따른 급격한 증가, 생활환경 변화와 에너지 사용 증가 등 화재 유발인자의 다양화로 인해 인적 물적 피해가 증가하고 있는 실정이다. 특히 다른 건물들과는 달리 공동주택의 거주자가 유아, 노인, 신체장애자 등 다양한 인적 구성의 형태로 이루어져 있어서 화재 발생 건수에 비해 인명피해가 월등히 높은 편이다. 공동주택에서의 화재에 대한 위험성을 인식하고, 그에 대한 인적 물적 피해를 최소화하기 위한 대책 마련이 시급하다. 본 논문은 CFAST(Consolidated Model of Fire Growth and Smoke Transport)를 사용하여 공동주택을 대상으로 실물 화재 실험을 실시하고 공간화재에서의 화재 성상을 파악하여 화재 시 개구부의 개폐 여부에 따라 발생되는 산소와 이산화탄소의 농도와 온도가 인체에 미치는 영향에 대해 알아본다. 개구부를 개방 했을 경우에 외부창문의 개폐 여부에 상관없이 모든 방의 온도 분포가 뚜렷하게 나타났지만 개구부를 폐쇄 할 경우에는 발화지점인 거실의 온도 분포만 나타났다. Flashover현상과 Back Draft현상은 개구부의 개폐여부에 상관없이 외부 창문을 폐쇄 했을 경우에 나타났지만 특히 모든 개구부와 외부창문을 폐쇄 했을 경우에 더욱 뚜렷하게 나타났다. 각 실은 점화 후 4분경에 최고 온도를 보였으며 다른 방에 비해 발화지점인 거실의 온도가 가장 높게 나타났다. 온도에 의해서는 두 가지 영향이 일어날 수 있는데, 하나는 비교적 장시간에 걸쳐 발생하는 열응력이고, 다른 하나는 짧은 시간에 발생할 수 있는 화상이다. 만약 피부온도가 $45^{\circ}C$에 이르면 인체는 고통을 느끼게 되며, 이보다 더 높은 온도에서는 깊은 피부조직까지 손상을 줄 수 있다. 움직이지 않는 사람에 대한 고통 유발 임계온도는 약 $200^{\circ}C$이며, 인체는 땀의 발산으로 온도에 대한 내성이 증가하지만 이체가 장시간 열을 받으면 사망에 이를 수 있다. 결론적으로 공동 주택을 대상으로 CFAST를 이용해 분석한 결과 플래쉬오버 현상으로 인해 화재가 성장하여 급격히 온도가 상승하다가, 산소 부족으로 인해 화재가 성장하지 않고 온도가 떨어지는 것을 알 수 있다. 화재 시 온도, 산소, 이산화탄소를 고려하였을 때 약 3분 이내에 대피해야 온도 및 가스로 인한 피해를 줄일 수 있을 것으로 판단된다.

  • PDF

A Study on the Conceptual Design of Quay Process Monitoring System (안벽공정 모니터링 시스템의 개념 설계에 관한 연구)

  • Kim, Ho-Kyeong;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.426-431
    • /
    • 2016
  • In quay processes in shipyards, it is difficult to manage workers and to maintain secure working environments because at least 1,000 people can occupy the quay at the same time. In this study, a system was designed to monitor the environment and processes of quay operation. In order to lower initial investments and the costs of maintenance and operation, the entire system consists of six connected components. Considering the communication environment of the shipyard site, Wi-Fi and the LoRa communication protocol were selected for the system. The feasibility of the communication protocols was verified by data transmission tests in the field. The designed system can provide real-time information about employees working in the quay area, the safety status of moored ships on the quay, and step-by-step alarms in dangerous situations based on the detected information. The system is expected to prevent or greatly reduce safety hazards.

Investigation on Users' Perception and Certification Status and Donning of Smoke Masks (방연마스크에 대한 사용자 인식, 인증 현황 및 착용성 조사)

  • Hyunwoo Son;Yeongeun Park;Eungwoo Lee;Eunji Kim;Youngbo Choi
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.68-73
    • /
    • 2023
  • Smoke masks have attracted great interests and have been supplied widely for the improvement of the safety during fire evacuation. However, there is not sufficient research on the practical utility, certification status and easy-donning about commercial smoke masks, therefore it is difficult to determine the actual usefulness of the smoke masks. In this study, we conducted a survey on users' perceptions and experiences about the smoke masks, and investigated the status of certification of 54 commercial smoke masks. We also performed donning tests and examined degrees of discomfort for 4 types of the smoke masks. Although 22% of 235 respondents had experienced the smoke masks before the test, and 23% of the respondents did not know the smoke masks, 93% of the respondents expected that the smoke masks could protect users from fire smokes and toxic gases. It was found that 41% of the commercial smoke masks did not certify according to domestic or overseas performance standards. Most certification standards have not effectively regulated maximum wearing time for the smoke masks. Only ASTM E 2952 and KFIS 024 had specific standards for the maximum wearing time of 30 s. As a result of donning tests for 4 types of smoke masks, the wearing time of the hood-type mask and self-contained smoke mask exceeded 30 s, therefore these types of smoke masks might increase the required safe evacuation time. On the other hand, it was also found that short education about the donning could reduce the wearing time by 19% and numbers of improper wearing by 89%.

Structural Safety Assessment of Tie-down for Securing Helicopter (헬리콥터 고정용 안전장치 구조 안전성 평가)

  • Myung Su Yi;Kwang-Chul Seo;Joo Shin Park
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.4
    • /
    • pp.372-379
    • /
    • 2023
  • International oil prices are expected to increase from $85 a barrel this year to up to $100 a barrel in the second half of the year; this is likely to increase orders for offshore plants in the global market. One main characteristic of offshore plants is that a large helideck is located on the top side, and aluminum alloys are used as the basic material of the structure for weight reduction and corrosion resistance. Shipowners are increasing the size of helicopters to quickly evacuate lives in the event of an emergency, and the safety use load of devices that can stably secure helicopters to the deck is also required to increase. Owing to the nature of the aluminum material, the structural strength caused by welding is greatly reduced; therefore, the fixing device must be designed by embedding it in the deck and fixing it with bolts. In this study, a model applying aluminum alloy 6082-T6 was developed to develop a helicopter fastening device that can be used for large helidecks (diameter = 28 m). The developed item was verified through nonlinear structural strength calculation to satisfy the load used for the actual fastening condition. The load condition with a 45° showed a lower ultimate strength than the 90° case owing to local plastic collapse. The nonlinear structural collapse behavior showed a result similar to that of the experimental test. The main contents derived from this study are considered to be reference materials when evaluating the structural strength of similar aluminum equipment.

An Experimental Study on the Pore Structure and Thermal Properties of Lightweight Foamed Concrete by Foaming Agent Type (기포제 종류에 따른 경량기포콘크리트의 기포구조 및 열적특성에 관한 실험적 연구)

  • Kim, Jin-Man;Choi, Hun-Gug;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.63-73
    • /
    • 2009
  • Recently, the use of lightweight panels in building structures has been increasing. Of the various lightweight panel types, styrofoam sandwich panels are inexpensive and are excellent in terms of their insulation capacity and their constructability. However, sandwich panels that include organic material are quite vulnerable to fire, and thus can numerous casualties in the event of a fire due to the lack of time to vacate and their emission of poisonous gas. On the other hand, lightweight foamed concrete is excellent, both in terms of its insulation ability and its fire resistance, due to its Inner pores. The properties of lightweight concrete is influenced by foaming agent type. Accordingly, this study investigates the insulation properties by foaming agent type, to evaluate the possibility of using light-weight foamed concrete instead of styrene foam. Our research found thatnon-heating zone temperature of lightweight foamed concrete using AP (Aluminum Powder) and FP (animal protein foaming agent) are lower than that of light-weight foamed concrete using AES (alkyl ether lactic acid ester). Lightweight foamed concrete using AES and FP satisfied fire performance requirements of two hours at a foam ratio 50, 100. Lightweight foamed concrete using AP satisfied fire performance requirements of two hours at AP ratio 0.1, 0.15. The insulation properties were better in closed pore foamed concrete by made AP, FP than with open pore foamed concrete made using AES.