• Title/Summary/Keyword: 인공 호흡기

Search Result 246, Processing Time 0.035 seconds

A Study on the Changes in Ventilator Care Rate and Outcome of Very Low Birth Weight Infants During Last Four Years (최근 4년간 극소 저출생 체중아의 인공 호흡기 치료율과 경과 변화에 관한 연구)

  • Jung, Byun Kyung;Kim, Yeoung Ju;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.11
    • /
    • pp.1073-1079
    • /
    • 2003
  • Purpose : Recently there has been a decrease in ventilator care rate and duration of very low birth weight infants(VLBWI) in Fatima Hospital. The aims of this study were to survey the frequency and duration of ventilation in VLBWI and to develop a non-invasive neonatal intensive care unit (NICU) policy. Methods : We performed a retrospective study of 284 newborn of infants less than 1,500 gm admitted to NICU and discharged from January 1998 to December 2001. Patients were intubated or applied continuous positive airway pressure(CPAP) via nasal prong immediately after presenting signs of respiratory distress. We analyzed epidemiologic data to study the changes in ventilator care rate, duration and outcome of ventilator care groups. Results : Of 284 newborn infants, 146 required invasive management, such as endotracheal intubation and assisted ventilation. The characteristics, the severity of clinical symptoms and laboratory findings in ventilator care groups at birth showed no significant differences. The annual proportion of infants requiring assisted ventilation decreased according to increasing gestational age. The median duration of ventilation decreased markedly from 6.0 days in 1998 to 2.7 days in 2001. Final complications and outcomes in ventilator care groups showed no significant differences. Conclusion : Our study shows a significant reduction in the invasiveness of the treatment of VLBW infants, which was not associated with an increased mortality or morbidity. A non-invasive strategy for the VLBW infant with minimal to moderate respiratory distress after birth in NICU is better than immediate invasive management. Non-invasive nasal CPAP is a simpler and safer method than invasive assisted ventilation.

Development of Periventricular Leukomalacia and Severe Intraventricular Hemorrhage in Very Low Birth Weight Newborns and Relationship with Ventilator Care (Study of Ventilator Care as a Risk Factor of PVL and PV-IVH) (극소저출생체중아의 뇌실주위백질연화증과 중증뇌실출혈의 발생과 인공호흡기 치료와의 상관관계)

  • Lee, Hak Sung;Lee, Sae Kyu;Kim, Yeong Jin;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.12
    • /
    • pp.1330-1336
    • /
    • 2005
  • Purpose : It has been suggested that changes in cerebral blood flow by ventilator care could be a risk factor in periventricular leukomalacia(PVL) and severe periventricular-intraventricular hemorrhage(PV-IVH). The study aims to assess the relationship between perinatal clinical events, including ventilator care, and the development of PVL and severe PV-IVH; especially, whether ventilator care could be causers of PVL and severe PV-IVH as an individual risk factor. Methods : Among 255 very low birth weight infants who survived in the Fatima neonatal intensive care unit from January 1999 to December 2003, 15 infants with PVL and eight infants with severe PV-IVH were classified as a study group, while 231 infants were enrolled as a control group. The analysis was performed retrospectively with medical records. Results : Twenty four infants were diagnosed with PVL or severe PV-IVH. Asphyxia, recurrent apnea, sepsis, acidosis and ventilator care were significantly increased in the PVL goup. Asphyxia, recurrent apnea, RDS, acidosis and ventilator care were significantly increased in the severe PV-IVH group. Conclusion : Infants with PVL or severe PV-IVH may have multiple perinatal risk factors including asphyxia, recurrent apnea, sepsis, acidosis, RDS and ventilator care. Because most patients with ventilator care have multiple perinatal risk factors, ventilator care does not cause PVL and severe PV-IVH independently. Therefore, incidences of PVL and severe PV-IVH can be decreased by not only gentle ventilation, but also more professional antenatal care.

Performance Characteristics of Portable Resuscitator with the Change of supply Oxygen Pressure (산소 공급압력 변화에 따른 운반형 인공호흡기의 성능 특성 연구)

  • Kim, Young-Soo;Kim, Min-Wook;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.87-91
    • /
    • 2016
  • Recently, it has been increasing an incidence of heart diseases which is a causative factor in sudden death as Korean population structure has been changing to an aging society. There is growing needs for A portable ventilator which automatically be operated by the pressure of the supplied oxygen and has been spread worldwide. So, we would like to present test methods in accordance with the performance requirements which are important for components of a respirator and a portable ventilator itself. And also would like to find the most suitable condition of internal pressure reduction for the performance requirements according to the changing conditions of internal pressure reduction setting of a portable ventilator.

A Meta-Analysis of the Ventilator Circuit Change Period on Ventilator-Associated Pneumonia (인공호흡기 회로 교환주기가 인공호흡기 관련 폐렴에 미치는 영향에 관한 메타 분석)

  • Song, Ju Hyun;Kim, Kyung Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.3
    • /
    • pp.111-121
    • /
    • 2010
  • Purpose: This meta-analysis was aimed to investigate the evidence of proper period of the ventilator circuit change using existing research. Methods: For this study, 14 published studies between 1995 and 2010 were tested by Macaskill, Funnel Plot, the Odds Ratio of DerSimonian and Laird, Fisher and Liptak analysis. Results: There were no publication bias found in the subjects. The results of the meta-analysis demonstrated no statistically significant differences were observed in neither the Odds Ratio (OR=1.18, 95% CI=0.94-1.47) of the frequency of ventilator-associated pneumonia and the mortality based on the period of the ventilator circuit change (Fisher p=.332, Liptak p=.498), nor the ventilation duration of ventilator (Fisher p=.843, Liptak p=.506), and the hospital length of stay (Fisher p=.254, Liptak p=.480). Conclusion: In order to present more concrete guidelines on the period of the ventilator circuit change, further research is warranted to thoroughly control confounding variables which related to the periods of the ventilator circuit change.

Clinical Study of Children Using Home Mechanical Ventilation (가정용 인공 호흡기를 사용하는 소아의 임상적 고찰)

  • Ahn, Young Joon;Lee, Seung Hyeon;Kim, Hyo-Bin;Park, Seong Jong;Ko, Tae Sung;Hong, Soo Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.4
    • /
    • pp.401-405
    • /
    • 2005
  • Purpose : The use of mechanically-assisted ventilators at home reduces morbidity and improves the quality of life in children with chronic respiratory failure. But in Korea there is no clinical data of children with home mechanical ventilation. We investigated ventilator types, duration, the causes of failure or death, and the cost needed for care. Methods : We retrospectively analyzed the medical records of 21 children who were admitted and who applied for home mechanical ventilation at the Pediatric Intensive Care Unit in Asan Medical Center. Phone interviews took place after discharge. and interviewed by phone after discharge. Results : The median age was 31 months; the median duration with ventilator was 25 months. Underlying diseases were 16 neuromuscular diseases, one metabolic disease and four chronic respiratory diseases. The types of ventilator were pressure and volume type(16 and five patients, respectively). The frequency of ventilation failure was once per 19 months. Weaning could be performed in three cases. Frequencies of admission after receiving ventilators were 1.7 times per year; the most common cause was pneumonia. Nine patients(43%) died; four of them died because of endotracheal tube obstruction. The costs for medical care were about 1,110,000 won per month. Conclusion : There is an increment in the numbers of individuals who need mechanical ventilation support. The most common cause of death was endotracheal tube obstruction. The most important problem for the patients was medical cost. There needs to be more interest in patients with ventilator and social welfare systems to support their families need to be prepared.

The effects of neonatal ventilator care or maternal chorioamnionitis on the development of bronchopulmonary dysplasia (산모의 융모양막염 및 인공호흡기 치료가 미숙아 만성 폐질환의 발생에 미치는 영향)

  • Yun, Ki-Tae;Lee, Dong-Whan;Lee, Sang-Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.8
    • /
    • pp.893-897
    • /
    • 2009
  • Purpose : Advances in neonatal intensive care have improved the survival rate of low-birth-weight infants, but mild bronchopulmonary dysplasia (BPD) with the accompanying need for prolonged oxygen supplement remains problematic. Maternal chorioamnionitis and neonatal ventilator care affect the development of BPD. This study aimed to examine whether maternal chorioamnionitis or neonatal ventilator care affect the development of BPD dependently or independently. Methods : We performed a retrospective study of 158 newborn infants below 36 weeks of gestational age and 1,500 gm birth weight admitted to the neonatal intensive care unit of Daegu Fatima Hospital between January 2000 and December 2006. We analyzed the incidence of BPD according to maternal chorioamnionitis and neonatal ventilator care. Result : Histologic chorioamnionitis was observed in 50 of 158 infants (31.6%). There were no significant differences in the development of BPD (P=0.735) between the chorioamnionitis (+) and chorioamnionitis (-) groups. In the multiple regression analysis, ventilator care (OR=7.409, 95% CI=2.532-21.681) and neonatal sepsis (OR=4.897, 95% CI=1.227-19.539) affected the development of BPD rather than maternal chorioamnionitis (OR=0.461, 95% CI=0.201-1.059). Conclusion : Ventilator care or neonatal sepsis may play a role in the development of BPD rather than maternal chorioamnionitis.

A Study on the Effects of the Early Use of Nasal CPAP in the Weaning of Mechanical Ventilators (인공호흡기 이탈시 비강내 CPAP 조기 사용 효과에 관한 연구)

  • Kim, Yeoung Ju;Jung, Byun Kyung;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1200-1206
    • /
    • 2003
  • Purpose : This study was conducted for the use of nasal continuous positive airway pressure (CPAP), by comparing the early use of non-invasive nasal CPAP with low intermittent mandatory ventilation(low IMV) and endotracheal CPAP in weaning a mechanical ventilator from infants with moderate respiratory distress syndrome(RDS). Methods : Thirty infants in the study group, with moderate RDS from November 2001 to June 2002, were administered surfactants and treated with the mechanical ventilator, and applied the nasal CPAP in weaning. Thirty infants of the control group, from January 1999 to September 2001, were applied low IMV and endoctracheal CPAP in weaning. Results : There were no significant differences in the characteristics, the severity of clinical symptoms, the initial laboratory findings and settings of the mechanical ventilator. After weaning, the study group showed no significant changes in $PaCO_2$. However, the control group showed a slight $CO_2$ retension after one and 12 hours. Twenty eight infants(93.3%) of the study group and 24 infants(80%) of the control group were successfully extubated. The primary cause of failure was apnea. There were no significant differences in the duration of weaning and the mechanical ventilator treatment between the groups. Complications in weaning were related to the fixation of nasal CPAP and the mechanical problems caused by endotracheal tube. Conclusion : Aggressive weaning is possible for moderate RDS, in which the nasal CPAP was used without the low IMV and the endotracheal CPAP process. It had no difficulties. In conclusion, the nasal CPAP is an adequate weaning method for moderate RDS.

Study of the risk factors for pulmonary interstitial emphysema related to mechanical ventilator care (인공호흡기 치료와 관련된 폐간질기종 발생의 위험인자에 대한 연구)

  • Kim, Sang Yeob;Lee, Pil Sang;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1179-1184
    • /
    • 2008
  • Purpose : Pulmonary interstitial emphysema (PIE) primarily occurs in preterm infants suffering from respiratory distress syndrome (RDS) and kept under mechanical ventilator care. Therefore, this study aimed to examine various risk factors for PIE, to identify conditions that can decrease the possibility of PIE development. Methods : PIE classification was conducted for 183 patients diagnosed to have RDS and receiving mechanical ventilator care with pulmonary surfactant between March 2000 and February 2007. The characteristics of each patient were analyzed through retrospective examination of their medical histories. Results : Among 183 patients, 17 had PIE; all factors, including birth weight, gestational age, RDS grade III or above, chorioamnionitis, and premature rupture of membranes, were statistically significant (P<0.05). The period of mechanical ventilator use was statistically significant, but the peak mean airway pressure and peak partial pressure of inspired oxygen were not. PIE mainly occurred on the right side or both sides rather than the left side and mostly developed within 72 h. The PIE group showed higher mortality rate than the control group, and the major cause of mortality was pneumothorax. Conclusion : Risk factors for PIE in infants suffering from RDS and kept under mechanical ventilator care include low gestational age, low birth weight, chorioamnionitis, and premature rupture of membranes. If any risk factors are noted, the infant must be observed closely for at least 72 h after birth.

The Effects of Oral Care with Chlorhexidine for Ill Patients to Prevent Ventilator-associated Pneumonia : A Meta-Analysis (중환자의 인공호흡기 관련 폐렴 예방을 위한 클로르헥시딘의 효과 : 메타 분석)

  • Lee, Ha-Nee;Park, Jeong Sook
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.8
    • /
    • pp.241-249
    • /
    • 2017
  • This study was to determine the effectiveness of oral decontamination with chlorhexidine for prevention of ventilator associated pneumonia(VAP) using meta-analysis. MEDLINE, Pubmed, Cochrane library CINAHL and RISS, Koreamed, KISS databases were searched. key words used 'Ventilator-associated pneumonia', 'oral care', 'chlorhexidine' Ninety studies met the inclusion criteria for the meta-analysis. data were analyzed by the Revman 5.3 program of cochrane library and assessed for methodological quality using RoB (The Cochrane's Risk of Bias). The main findings of the current study suggest that chlorhexidine oral care have a positive impact on Ventilator associated pneumonia.

Survey of Current Status of the Patients with Home Ventilator in Seoul and Kyunggi Province (가정용 인공호흡기를 사용하는 서울 및 경기 지역 환자의 실태)

  • Ahn, Jong-Joon;Lee, Ki-Man;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.5
    • /
    • pp.624-632
    • /
    • 2000
  • Background : Home ventilation can decrease hospital-acquired infection, increase physical activity, improve nutritional status, enhance quality of life, and reduce medical costs. The number of patient using home ventilators has been increasing, particularly in Europe and United States. Although the number of patients with home ventilation has been increasing in Korea, the current status of these patients is not well known. This study was undertaken to obtain basic information upon these patients in addition to evaluating any problems related to patients' home care in our country. Methods : A register of 92 patients with home ventilators in Seoul and Kyunggi Province were obtained from commercial ventilator supply companies. The patients were contacted by phone and 29 of them accepted our visit. Information concerning education about home care before discharge, equipment cost, and problems related to home care were documented. The mode and preset variables of the home ventilator were checked; tidal volume (TV), peak airway pressure, and oxygen saturation were measured. Results : There were 26 males (90%) and their mean age was 48.0 (${\pm}20.1$) years. The underlying diseases were : 21 neuromuscular disorders, 2 spinal cord injuries, 6 chronic lung diseases. Among the caregivers, spouses (n=14) predominated. Education for home care before discharge was performed primarily by intensive care unit nurses and the education for ventilator management by commercial companies. Twenty-five of the 29 patients had tracheostomies. Volume targeted type (VTT ; n=20, 69%) was more frequently used than the pressure targeted type (PTT). Twenty-three of the 29 patients purchased a ventilator privately, which cost 7,450,000 (${\pm}$3,290,000) won for a PTT, and 14,280.000 (${\pm}$3,130,000) won for a VTT. Total cost for the equipment was 11,430,000 (${\pm}$634,000) won. The average cost required for home care per month was 1,120,000 (${\pm}$1,360, 000) won. Conclusion : The commonest underlying disease of the patients was neuromuscular disease. The VTT ventilator was primarily used with tracheostomy. Patients and their families considered the financial difficulties associated with purchasing and maintaining equipment for home care an urgent problem. Some patients were aided by a visiting nurse, however most patients were neglected and left without professional medical supervision.

  • PDF