• Title/Summary/Keyword: 인공호흡

Search Result 245, Processing Time 0.04 seconds

The Development of Web-Based Ventilator Management Education Program (웹기반 '인공호흡관리' 교육프로그램 개발)

  • Choi, Young-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5284-5291
    • /
    • 2012
  • This research is to develop the Web-Based Ventilator Management Education Program that reflects the needs of nursing site nursing which is intended to help nursing duties. ISD model-building process has been developed for the analysis, design, development, operation, and evaluation of methods. The education program was developed from April to July 2011, and SPSS 18.0 was used for data analysis. The analysis stage, document review and requirement analysis, content analysis, learner analysis, technology and environment analysis have been executed. Through the processes, higher education requirements for the practical ventilator, a large number of subjects under the age of 30, and the career of less than 3 years of ICU were searched. At the design stage, the education content that was presented by the content expert group was executed in information design, mutual interaction design, synchronization design through discussion with program experts. At the development stage, author made the story flow and gathered data and integrated it through the review of related document and data. At the operation and evaluation stage, author executed the developed program and revised and supplemented it on the basis of the evaluation results through the experts and subjects evaluation. The Web-Based Ventilator Management Education Program could contribute to the improvement of nursing because the program has been developed to reflect the diverse needs of nursing practice in the process of building program.

Surgical Treatment of Acute Prosthetic Valve Fai lure by Thrombosis -One Case Report- (혈전증에 의한 급성 인공판막기능부전의 수술 1례)

  • Lee, Jae-Deok;Lee, Seo-Won;Lee, Jae-Won;Sin, Je-Gyun
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.651-654
    • /
    • 1996
  • Recently, we report a surgical experience of one case of acute prosthetic valve failure due to throe- bosis. The patient was 39-year old male who complained of dyspnea and orthopnea for 3 days before admission. The patient had not taken anticoagulant therapy for recent 4 months against medical ad- vice. The limitation of valve motion was revealed on echocardiography. We performed emergency reoperation with thrombectomy and prosthetic valve replacement. The patient had anuncomplicated postoperative course and have been followed up.

  • PDF

Development of Periventricular Leukomalacia and Severe Intraventricular Hemorrhage in Very Low Birth Weight Newborns and Relationship with Ventilator Care (Study of Ventilator Care as a Risk Factor of PVL and PV-IVH) (극소저출생체중아의 뇌실주위백질연화증과 중증뇌실출혈의 발생과 인공호흡기 치료와의 상관관계)

  • Lee, Hak Sung;Lee, Sae Kyu;Kim, Yeong Jin;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.12
    • /
    • pp.1330-1336
    • /
    • 2005
  • Purpose : It has been suggested that changes in cerebral blood flow by ventilator care could be a risk factor in periventricular leukomalacia(PVL) and severe periventricular-intraventricular hemorrhage(PV-IVH). The study aims to assess the relationship between perinatal clinical events, including ventilator care, and the development of PVL and severe PV-IVH; especially, whether ventilator care could be causers of PVL and severe PV-IVH as an individual risk factor. Methods : Among 255 very low birth weight infants who survived in the Fatima neonatal intensive care unit from January 1999 to December 2003, 15 infants with PVL and eight infants with severe PV-IVH were classified as a study group, while 231 infants were enrolled as a control group. The analysis was performed retrospectively with medical records. Results : Twenty four infants were diagnosed with PVL or severe PV-IVH. Asphyxia, recurrent apnea, sepsis, acidosis and ventilator care were significantly increased in the PVL goup. Asphyxia, recurrent apnea, RDS, acidosis and ventilator care were significantly increased in the severe PV-IVH group. Conclusion : Infants with PVL or severe PV-IVH may have multiple perinatal risk factors including asphyxia, recurrent apnea, sepsis, acidosis, RDS and ventilator care. Because most patients with ventilator care have multiple perinatal risk factors, ventilator care does not cause PVL and severe PV-IVH independently. Therefore, incidences of PVL and severe PV-IVH can be decreased by not only gentle ventilation, but also more professional antenatal care.

The Research of Comparison Evaluation on the Decline in Artifact Using Respiratory Gating System in PET-CT (PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가)

  • Kim, Jin-Young;Lee, Seung Jae;jung, Suk;Park, Min-Soo;Kang, Chun-Goo;Im, Han-Sang;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.63-67
    • /
    • 2015
  • Purpose Among various causes that influence image quality degradation, various methods for decrease in Artifact occurred by respiration of patients are being used. Among them, this study intended to evaluate CTAC Shift correction method and additional scan compare to the Scan(Q static scan) using respiratory gated system. Materials and Methods This study was conducted on 10 patients, and used PET-CT Discovery 710 (GE Healthcare, MI, USA) and Varian's RPM system. 5.18 Mbq per kg of $^{18}F$-FDG was injected on patients, asked them to take a rest for 1 hour in the bed, and conducted test after urination. Images were visualized through Q static scan, CTAC Shift correction method, Additional scan based on the Whole body scan(WBS) with Artifact. Decrease in Artifact was compared in each image, conducted Gross Evalution, and measured changes of SUVmax. Results For image obtained through the CTAC Shift correction method through WBS with Artifact, 12~56%, Q static scan image showed 17~54% of change rate and Additional Scan showed -27~46% of change rate. In Blind Test, the CTAC Shift correction image showed the highest point with 4 points, Q static scan image showed 3.5 points, and Additional scan image showed 3.4 points. The standardized WBS scan through Oneway ANOVA and three types of Scan method showed significant difference(p<0.05), and did not show significant difference between the three Scan methods(p>0.05). However, the three Scan methods showed significant difference in Blind test. Conclusion Additional scan and Q static scan require more time than the CTAC Shift correction method, there is concern about excessive exposure to patients by CT rescan and Q static scan is difficult to apply on patients with inconsistent respiration or irregular respiration cycle due to pain. For CTAC Shift correction method, limited correction is possible and the range is limited as well. It is considered as a useful method of improving diagnostic value when hospitals use the system appropriately and develop various advantageous factors of each method.

  • PDF

Effects of a Home Respiratory Management Program on Unmet Healthcare need and Healthcare resource utilizations for Patients applying Home Mechanical Ventilator with Amyotrophic Lateral Sclerosis (가정형 인공호흡기 사용 중인 재가 근위축성 측삭증후군 환자의 가정간호기반 호흡관리 프로그램이 미충족의료와 의료자원이용에 미치는 효과)

  • Hwang, Moon Sook;Park, Jin-Hee
    • Journal of Industrial Convergence
    • /
    • v.17 no.4
    • /
    • pp.77-86
    • /
    • 2019
  • The purpose of this study was to identify the effect of Home Health Nursing based Respiratory Management Program (HHNbRMP) on unmet healthcare need and healthcare resource utilizations of patients applying the home mechanical ventilator in the home with amyotrophic lateral sclerosis. The subjects of this study were 40 patients placed in an experimental group(n=19) and a control group(n=21), respectively. This HHNbRMP based on Cox's interaction model was consisted of cognitive assent (education, specialized medical care, case management), internal motivation (airway clearance, thoracic and air accumulated exercise) and psychological response (meditation & active listening). The intervention was applied to experimental group during 12 weeks. As variables was measured at baseline, twelve, twenty-four weeks and healthcare unmet need, resource utilizations (admission, out patient department, emergency room) was measured at 24 weeks. The data were analyzed by t-test, ANOVA and Repeated Measures ANCOVA. This intervention was not effective the unmet healthcare need. But the admission in to the hospital among the healthcare resource utilizations variables showed a significant difference at twenty-four weeks(t=4.17, p=.049). This results suggest that applying this program tailored to patients condition, utility of medical resource would be decreased, specially admission.

Clinical Study of Children Using Home Mechanical Ventilation (가정용 인공 호흡기를 사용하는 소아의 임상적 고찰)

  • Ahn, Young Joon;Lee, Seung Hyeon;Kim, Hyo-Bin;Park, Seong Jong;Ko, Tae Sung;Hong, Soo Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.4
    • /
    • pp.401-405
    • /
    • 2005
  • Purpose : The use of mechanically-assisted ventilators at home reduces morbidity and improves the quality of life in children with chronic respiratory failure. But in Korea there is no clinical data of children with home mechanical ventilation. We investigated ventilator types, duration, the causes of failure or death, and the cost needed for care. Methods : We retrospectively analyzed the medical records of 21 children who were admitted and who applied for home mechanical ventilation at the Pediatric Intensive Care Unit in Asan Medical Center. Phone interviews took place after discharge. and interviewed by phone after discharge. Results : The median age was 31 months; the median duration with ventilator was 25 months. Underlying diseases were 16 neuromuscular diseases, one metabolic disease and four chronic respiratory diseases. The types of ventilator were pressure and volume type(16 and five patients, respectively). The frequency of ventilation failure was once per 19 months. Weaning could be performed in three cases. Frequencies of admission after receiving ventilators were 1.7 times per year; the most common cause was pneumonia. Nine patients(43%) died; four of them died because of endotracheal tube obstruction. The costs for medical care were about 1,110,000 won per month. Conclusion : There is an increment in the numbers of individuals who need mechanical ventilation support. The most common cause of death was endotracheal tube obstruction. The most important problem for the patients was medical cost. There needs to be more interest in patients with ventilator and social welfare systems to support their families need to be prepared.

Development of Novel Assistive Device for Improving Usability of BVM (인공호흡기 사용성 향상을 위한 새로운 보조기구 개발)

  • Jeon, Gang-Hyun;Park, Yong-Jai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.420-426
    • /
    • 2020
  • In this study, an assistive device for BVM (Bag Valve Mask) was developed. When emergencies occur, rescuers must perform artificial respiration within four minutes utilizing suitable BVM. If not, the patient can suffer serious damage within their brain and body systems. The rescuer must execute artificial respiration until the patient arrives at the hospital. In the process of artificial respiration, the rescuer can feel fatigued in their forearm muscles, particularly those who may have smaller hands or weaker muscle strength. Many products have been developed to solve these problems, but these products are difficult to market and commercialize because of their volume, size, and difficulty of use. In this paper, the BVM assistive device that has been previously manufactured was improved, and an attempt was made to devise a new method that reduces the burden on the user. The BVM assistive device can be divided into three-parts: a head part for compressing the air bag, which can control the amount of air; the body part for coupling with BVM; and finally, the handle that can rotate for better use on various postures of patients. Throughout the experiment, the assistive device could inject an equal amount of air into the patients. As a result, the rescuer could feel less fatigue and inject a suitable amount of air to emergency patients during artificial respiration.

Analysis of Respiratory Motion Artifacts in PET Imaging Using Respiratory Gated PET Combined with 4D-CT (4D-CT와 결합한 호흡게이트 PET을 이용한 PET영상의 호흡 인공산물 분석)

  • Cho, Byung-Chul;Park, Sung-Ho;Park, Hee-Chul;Bae, Hoon-Sik;Hwang, Hee-Sung;Shin, Hee-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.174-181
    • /
    • 2005
  • Purpose: Reduction of respiratory motion artifacts in PET images was studied using respiratory-gated PET (RGPET) with moving phantom. Especially a method of generating simulated helical CT images from 4D-CT datasets was developed and applied to a respiratory specific RGPET images for more accurate attenuation correction. Materials and Methods: Using a motion phantom with periodicity of 6 seconds and linear motion amplitude of 26 mm, PET/CT (Discovery ST: GEMS) scans with and without respiratory gating were obtained for one syringe and two vials with each volume of 3, 10, and 30 ml respectively. RPM (Real-Time Position Management, Varian) was used for tracking motion during PET/CT scanning. Ten datasets of RGPET and 4D-CT corresponding to every 10% phase intervals were acquired. from the positions, sizes, and uptake values of each subject on the resultant phase specific PET and CT datasets, the correlations between motion artifacts in PET and CT images and the size of motion relative to the size of subject were analyzed. Results: The center positions of three vials in RGPET and 4D-CT agree well with the actual position within the estimated error. However, volumes of subjects in non-gated PET images increase proportional to relative motion size and were overestimated as much as 250% when the motion amplitude was increased two times larger than the size of the subject. On the contrary, the corresponding maximal uptake value was reduced to about 50%. Conclusion: RGPET is demonstrated to remove respiratory motion artifacts in PET imaging, and moreover, more precise image fusion and more accurate attenuation correction is possible by combining with 4D-CT.

Comparison of Continuous Mechanical Ventilation and Internal Fixation in Flail Chest Injuries (불안정 흉벽손상에서 지속적 인공호흡법과 내적 늑골고정술의 비교)

  • Gang, Chang-Hui;Jang, In-Seong
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.413-418
    • /
    • 1997
  • From January, 1992 to June, 1996, )7 patients with flail chest were treated at Sonnchunhyang university hospital. 15 patients were managed by internal fixation of fractured ribs, whereas the remaining 22 patients were managed by endotracheal intubation and intermittent positive-pressure ventilation alone. There were no difference between two groups in age, sex, the severity of injury to the chest wall and the nature of associated injuries. Average dur'Btion of assisted ventilation was 5.7 $\pm$ 1.7 days in the patients treated by internal fixation versus 8.7 $\pm$ 3.3 days In the patients treated by continuous me hanical ventilation. Average stay in the intensive care unit was 8.3 $\pm$ 3.9 days for the patients treated by internal fixation, whereas it was $13.2\pm4.1$ days in the group treated by continuous mechanical ventilation alone. In the group treated by internal fixation, complications were 3 atelectases(20.0%), 1 pneumonia(6.7%), 2 operative wound problems(12.3%) and 1 barotrauma(6.7%). In the other group, 7 atelectases(31.8%), 4 pneumonitis(18.2%), 2 empyemas(9.1%) and 3 barotraumas(1).6%). The mortality rate was 13.3%(2/15) in the surgically treated patients, whereas it was 22.7%(5122) in the other group. The treatment of flail chest by internal fixation resulted in speedy recovery, decreased complications and mortalities, and better ultimatc cosmetic and functional results.

  • PDF

Extracorporeal Life Support with a Twin-pulse Life Support (T-PLS) System (이중 박동성 인공심폐기(Twin-Pulse Life Support, T-PLS)를 이용한 심폐순환보조)

  • Lee, Dong-Hyup;Lee, Jang-Hoon;Jung, Tae-Eun
    • Journal of Chest Surgery
    • /
    • v.40 no.7 s.276
    • /
    • pp.512-516
    • /
    • 2007
  • A mechanical circulatory support system is a life-saving option for treating acute severe respiratory failure or cardiac failure. There are currently a few types of assist devices and the Twin-Pulse Life Support (T-PLS) system is a kind of pulsatile pump. We report here on three patients with severe life threatening cardiopulmonary dysfunction who had the T-PLS system used as an assist device. The indications for applying the T-PLS system were continuing respiratory or cardiac failure in spite of maximal ventilatory and inotropic support. There were two patients with acute respiratory failure due to infection and one patient with cardiac failure due to acute myocarditis. One respiratory failure patient and one cardiac failure patient survived after applying the T-PLS system for 3 days and 5 days, respectively. The T-PLS system is useful as an assist device and it should be considered before multi-organ failure occurs.