Trido Mitral Valve Replacement with Dacron Collar Prosthetic Valve due to Paravalvular Leak (판막주위 누출에 대한 다크론 확장 인공판막을 이용한 판막치환술 치험)

  • 배윤숙;정성철;김우식;정승혁;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.822-825
    • /
    • 2002
  • The paravalvular leak after redo mitral prosthetic valve replacement is rare but serious complication when it does happen. This condition should be corrected surgically to increase life span and improve symptoms. But simple closure or patch closure of paravalvular leak are not effective in cases of weak annulus or broad defect. We report 3 cases of trido mitral valve replacement using mechanical valve with its sewing ring expanded by a collar of Dacron sheet. The prosthetic sewing ring is anchored on the weak mitral annulus with multiple interrupted sutures, while the Dacron collar is contineuously sutured to the left atrial wall for blood tight sealing. All of the three cases showed event free postoperative course.

The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves (인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향)

  • 이계한;서종천
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.297-303
    • /
    • 1998
  • The sinus distal to the prosthetic heart valve influences the valve closure behavior and velocity field near the valve, therefore affects the hydrodynamic performance of the prosthetic heart valve. In order to study the effects of valve distal geometry on the hydrodynamic performance of the prosthetic valves, mechanical bileaflet valve(SJMV), monoleaflet polymer valve(MLPV) and trileaflet polymer valve(FTPV) are inserted in the test sections which have the straight and the sinus shape distal to the valve. Leakage volumes and systolic mean pressure drops are measured in the pulsatile mock circulation flow loop. Leakage volumes are slightly less and systolic mean pressure drops are higher in the sinus test section comparing to those in the straight test section, but the differences are statistically insignificant. Flow waveforms are analyzed in order to predict the valve closure behavior. The distal sinus does not affect the closure of the MLPV, but early valve closure of SJMV is observed in the sinus test section. This effect is more significant in FTPV, and the reverse flow peak of FTPV is reduced in the sinus test section. Therefore the sinus distal to the valve can reduce the reverse flow jet caused by sudden valve closure.

  • PDF

The Clinical Experiences of "New Duromedics Valve" Replacement (새로운 Duromedics 인공판막 치환의 임상고찰)

  • Gang, Myeon-Sik;Yu, Gyeong-Jong;Yun, Chi-Sun;Park, Han-Gi
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.979-985
    • /
    • 1997
  • Between October 1991 and May 1995, 256 "New Duromedics Valve"(Edward TEKNA Bileaflet Valve) were implanted in 208 adult patients(171 mitral, 82 aortic and 3 tricuspid) with age ranging from 18 years to 70 years(mean 48.2$\pm$ 11.6 years). Postoperative complication rates were 12.2%, but there was none valve related one. Overall early mortality rate were 1.4%(1.6% for MVR, 2.1% for DVR, and none for AVR or TVR) respectively. Follow-up was 99% completed ranging in duration from 2 months to 46 months. There were 6 valve-related late complications(2.9%) with 2 patients with upper gastrointestinal bleeding, 2 with cerebral thxomtioembolism, 1 with valve thrombosis and 1 with valve endocarditis. Freedom from these valve-related major complications were 89.9% at 40 months. There were 5 late deaths(2.4%). one of these late deaths was considered valve-related. Overall actuarial survival rates at 40 months were 95.5%, 96.8% for mitral, 97.1% for aortic, 100% for tricuspid, and 92.0% for double valve replacement respectively. Preoperative New York Heart Association functional class were 2.9, and 1.3 in post-operative state. We have been trying to keep the international normalized ratio(INR) with range of 2.5 to 3.0. The INR of 4 patients of 5 with anticoagulant ralated complications was beyond the range. To reduce the rate of anticoagulant related complications, we felt very strongly that the INR should be kept between 2.5 and 3.0. In our cases, there was no structural failure or significant hemolysis in the absence of periprosthetic leak. This experience encourages us to continue using the "New Duromedics Valve".omedics Valve".uot;.

  • PDF

Effect of Compliant Structure in the Accelerated Heart Valve Fatigue Tester on the Surface Pitting of the Disk (기계식 인공판막의 표면 부식에 영향을 미치는 가속내구시험기의 컴플라이언스 구조에 관한 연구)

  • Kim, Dong-Uk;Lee, Hwan-Seong;Kim, Nam-Gyun
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.285-290
    • /
    • 1998
  • There are various reports on the fracture of mechanical heart valves implanted in human or animal, and they are pointed out that problems are induced by an erosion of disk surface, due to a cavitation effect. We have been investigating this mechanism using accelerated fatigue tester, and it was found that erosion was enhanced by a compliance effect in the test circuit. In this study, effects of compliance value and location on erosion were discussed, while disk closing velocity was measured by a high speed video camera. It was clarified that faster closing velocity was resulting in a enhancement of erosion on the disk surface.

  • PDF

Hemolytic Anemia due to Tiny Prosthetic Paravalvular Leakage (작은 인공판막주위 누출에 의한 용혈성 빈혈)

  • 문광덕;김대영
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.444-448
    • /
    • 1996
  • Hemolytic anemia due to tiny prosthetic paravalvular leakage is one of a complication of prosthetic valve replacement. Mild Hemolysls usually occurs after aortic valve replacement with mechanical valve but rarely occurs in mitral valve position especially in case of tissue valve. Cardiac valves fabricated from biologic material are associated with a reduced incidence of hemolytic anemia. Hemolysis was reported in patients with an lonescu-Shiley bovine pericardial xenograft prosthesis in the aortic position but not in the mitral site. A 41-year-old female patient was admitted due to sudden development dark colored urine. About 10 years ago the patient was underwent MVR (Mitral Valve Re lacement) with fTmm lonescu-Shiley valve due to MR (Mitral regurgitation). Echocardiographic examination showed mild degree of mitral regurgitation with valvular thickening. However, there was no definitive evidence of paravalvular leakage. The peripheral blood smear showed nomochromic normocytic anemia, but the hematologic and urinary examination revealed severe hemolytic evidence. Mitral valve replacement with St. Jude Medical valve (27mm) was done and intraoperatively, a tiny paravalvular leakage was found which was regarded as the point of hemolysis. The hemolytic evidence completely disappeared. We are reporting a case of severe hemolytic anemia due to tiny prosthetic paravalvular leakage with a review of the literature.

  • PDF

Nonstructural Dysfunction of Mechanical Valve (인공판막의 비구조적 기능이상)

  • Shin, Jong-Mok;Jeong, Dong-Seop;Kim, Kyung-Hwan;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.1
    • /
    • pp.91-93
    • /
    • 2001
  • 기계판막의 비구조적 기능이상은 판막 치환 후 생길 수 있는 심각한 합병증 중의 하나이다. 이러한 기계판막의 비구조적 기능이상은 일반적으로 1) pannus나 조직 혹은 봉합물질에 의한 장애 2) 치환 판막 주위의 틈 3) 부적절한 판막의 크기나 위치, 판막 삽입시의 잘못 등에 의해 생긴다. 저자들은 상대적으로 작은 판막륜을 가진 환자에서 치환 판막의 잘못된 위치로 야기된 pannus 형성에 의한 판막의 기능부전을 경험하였으며, 이 환자에 대해 pannus 제거 후 판막륜 확장술(닉스 술식, Nicks procedure)을 포함한 판막 재치환술을 성공적으로 시행하여 이를 보고하는 바이다.

  • PDF

Surgical Treatment of Prosthetic Valve Endocarditis after Reconstruction of the Intervalvular Fibrous Trigon -A case report- (판막간 섬유체 재건을 시행한 후 발생한 인공판막 심내막염의 수술적 치유 -1예 보고-)

  • Choi, Seon-Uoo;Kim, Wook-Sung;Min, Ho-Ki;Kang, Min-Woong;Lee, Young-Tak;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.755-758
    • /
    • 2008
  • We report here on a case of performing a redo-operation for a 65-years-old male patient who had prosthetic endocarditis after reconstruction of the fibrous skeleton due to infective endocarditis 8 years earlier. An aortic annular abscess with a 1cm sized subvalvular abscess and mobile mitral valve vegetation with destruction of the fibrous skeleton was shown on the preoperative echocardiography. An emergency operation was performed due to heart failure. Reconstruction of both the aortic and mitral annuli and the fibrous skeleton was done by using two separate bovine pericardial patches and then mechanical valves were implanted. The postoperative echocardiography shows no paravalvular leakage. The patient has been followed up with no symptoms.

Reoperations on Heart Valve Prostheses (인공심장판막에 대한 재치환술)

  • 김재현;최세영;유영선;이광숙;윤경찬;박창권
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1165-1171
    • /
    • 1998
  • Background: All currently available mechanical and bioprosthetic valves are associated with various types of deterioration leading to dysfunction and/or valvular complications. Reoperation on prosthetic heart valves is increasingly under consideration for both clinical and prophylactic indications. This review was conducted to determine the factors affecting the risk of reoperation for prosthetic valve replacement. Material and method: From January 1985 to July 1996, 124 patients underwent reoperation on prosthetic heart valves, and 3 patients had a second valve reoperation. The causes of reoperation were prosthetic valve failure(96 cases, 77.4%), prosthetic valve thrombosis(16 cases, 12.9%), prosthetic valve endocarditis(7 cases, 5.6%) and paravalvular leak(5 cases, 4.1%). This article is based on the analysis of the experience with particular emphasis on the preoperative risks affecting the outcome of the reoperation. Result: Overall hospital mortality rate was 8.9%(11/124). Low cardiac output was the most common cause of death(70.6%). Left ventricular systolic dimension(p=0.001), New York Heart Association functional class IV(p=0.003) and serum creatinine level(p=0.007) were the independent risk factors, but age, sex and cardiothoracic ratio did not have any influence on the operative mortality. Follow-up period was ranged from 3 to 141 months (mean, 50.6 months). A late mortality rate was 1.8%. Conclusion: The surgical risk of reoperation on heart valve prostheses in the advanced NYHA class patients is higher, therefore reoperation is recommended before the hemodynamic impairment become severe.

  • PDF

Surgical Treatment of Acute Prosthetic Valve Fai lure by Thrombosis -One Case Report- (혈전증에 의한 급성 인공판막기능부전의 수술 1례)

  • Lee, Jae-Deok;Lee, Seo-Won;Lee, Jae-Won;Sin, Je-Gyun
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.651-654
    • /
    • 1996
  • Recently, we report a surgical experience of one case of acute prosthetic valve failure due to throe- bosis. The patient was 39-year old male who complained of dyspnea and orthopnea for 3 days before admission. The patient had not taken anticoagulant therapy for recent 4 months against medical ad- vice. The limitation of valve motion was revealed on echocardiography. We performed emergency reoperation with thrombectomy and prosthetic valve replacement. The patient had anuncomplicated postoperative course and have been followed up.

  • PDF