• Title/Summary/Keyword: 인공고관절 전치환술

Search Result 10, Processing Time 0.027 seconds

The Comparison of Bonded/Unbonded Stem-Cement Interface in Total Hip Replacement -Experimental Study (인공 고관절 전치환술에서 주대-시멘트 경계층의 접착 및 비접착 고정술의 비교를 위한 실험적 연구)

  • Han, J.H.;Yoon, Y.S.;Lee, J.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.951-955
    • /
    • 2001
  • The experimental comparison between bonded and unbonded types stem-cement interface was carried out on axisymmetric stem-cement-aluminum model of the femoral component of a total hip replacement. Human femur was modeled in non-tapered and tapered($7.5^{\circ}$) aluminum hollow cylinders to emulate the diaphyseal and metaphyseal segments of the femur. For unbonded type, we tested stems with three different taper angles($5^{\circ},\;7.5^{\circ},\;10^{\circ}$). In every case, the cement-aluminum interface was designed to endure 8MPa shear strength. (a measured value at cement-bone interface) We tested aluminum models under axial loading for both cases. As an experimental result, it was found that unbonded stem sustained more axial load as bonded stem in both cases, diaphyseal and metaphyseal models. The unbonded types failed in cement mantle under axial compressive load, while the bonded ones failed in shear at cement-aluminum interface. These results suggest that a polished stem will sustain much higher axial load than a roughened stem. And a polished stem will make more stable cement-bone interface that may promote better osteosythesis around the stem.

  • PDF

Developing Activity Based Clinical Pathway for Patients with Total Hip Replacement (활동기준관리를 적용한 인공고관절 전치환술 Clinical Pathway 개발)

  • Hong, Yoon-Mi
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.8 no.4
    • /
    • pp.669-689
    • /
    • 2002
  • Purpose : The purpose of the present study is to develop a clinical pathway applied with activity-based management methodology for efficient clinical management to cope with rapid changing medical environments. Method : After making a preliminary pathway based on which a conceptual frame of reference was established to develop a clinical pathway, the final one was confirmed by verifying experts validity and clinical validity. The ultimate activity-based clinical pathway was restructured after clarifying, schematizing and analyzing the whole activities of clinical pathway in accordance with the conducting process of activity-based management. Result : A clinical pathway for total hip replacement was developed, in which the vertical axis consisted of assessment, examination, consultation, medication, treatment, diet, activity, and education, and the horizontal axis was composed of six days of hospitalization. Then, on the basis of the development, the clinical pathway including the improved contents and information was restructured after making the reform measure by analyzing each of activities in the pathway. And the list of contents related to the clinical management activity was made, which was described its main contents and the pre-activities that ought to be completed before conducting each of activities in the pathway. Conclusion : The clinical pathway applied with activity-based management may be used as a standard guidance for providing continuous and consistent patient care. It will provide the information for nursing activities to nurses and the management information about hospital and nursing activities to the hospital administrators. It will also be used as a tool for communication between medical staff. Besides, it will contribute to creating profits for the hospital by shortening the length of stay in patients.

  • PDF

Effects of Structured Exercise Program on Hip Pain, Physical Function and Quality of Life in Patients with Total Hip Arthroplasty (구조화된 운동 프로그램이 인공고관절 전치환술 환자의 고관절 통증, 신체기능 및 삶의 질에 미치는 효과)

  • Kwon, Eunhee;Lee, Haejung;Lee, Sunghwa
    • Journal of muscle and joint health
    • /
    • v.25 no.2
    • /
    • pp.122-134
    • /
    • 2018
  • Purpose: The purpose of this study was to develop a 12-week structured exercise program (12-week-SEP) and evaluate its effects on pain, physical function and quality of life in patients with total hip arthroplasty (THA). Methods: A nonequivalent control group non-synchronized design was utilized to examine the effects of the 12-week-SEP on patients' outcomes after THA. A total of 46 adult patients (experimental group=25, control group=21) who had THA were recruited for the study. The 12-week-SEP consisted of education, exercise (muscle strengthening and progressive walking), and feedback. Data were analyzed by SPSS/WIN 21.0 using the $x^2$ test and repeated measures ANOVA. Results: The mean age of the participants was 60.9 years and 25 men (54.5%) and 21 women (45.7%) were included in the study. There were significant intervention effects on pain reduction and increased physical function but no effects on quality of life. Conclusion: The 12-week-SEP provided pain relief and enhanced physical function in patients underwent THA. Clinical application of the 12-week-SEP can improve postoperative nursing practices for patients with THA. Future research with larger sample is of necessity to obtain greater generalizability of the empirical evidences of the 12-week-SEP.

Behavior Analysis of the Treated Femur and Design of Composite Hip Prosthesis (대퇴부 거동 해석 및 복합재료 보철물 설계)

  • 임종완;하성규
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.119-130
    • /
    • 2002
  • The nonlinear finite element program has been developed to analyze the design performance of an artificial hip prosthesis and long term behavior of a treated femur with stems made of composite material after cementless total hip arthroplasty(THA). The authors developed the three dimentional FEM models of femoral bone with designed composite stem which was taken with elliptic cross section of 816 brick elements under hip contact load and muscle farce in simulating single leg stand. Using the program, density changes, stress distributions and micromotions of the material femoral bone were evaluated by changing fiber orientation of stems for selected manufacturing method such as plate cut and bend mold. The results showed that the composite materials such as AS4/PEEK and T300/976 gave less bone resorption than the metallic material such as cobalt chrome alloy, titanium alloy and stainless steal. It was found that increasing the long term stability of the prosthesis in the femur could be obtained by selecting the appropriate ply orientation and stacking sequence of composite.

Wear and Implantation Tilt Measurements using X-ray and CAD (X-ray영상과 CAD를 이용한 인공고관절의 마모 및 식립각 측정법)

  • Lee, Jong Min;Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.107-114
    • /
    • 2018
  • Long-term complications such as loosening, wear, osteolytic lesion and granulomatous reaction by foreign bodies can occur, after total hip arthroplasty. The implantation alignment effects dislocation and wear, according to its amount and direction. Wear particles in total hip arthroplasty brings about biochemical complications such as osteolysis or send wear. In this sense, it is important to regularly check wear and alignment of total hip replacement. Because the wear in followup of 10 years may remain in a small amount, like a 1 or 2 mm generally, somewhat precise measurement tool has to be established. The wear and alignment measurement softwares commercially available currently lack in project saving or reproducibility. This study suggests a reliable method for the measurement using an X-ray image and a CAD software. The proposed method can be executed only if having a CAD software under most of current general clinical radiographical environment. The proposed was revealed through tests for the method to have accuracy of 0.06 mm with precision of 0.05 mm for wear measurement, and precision of 0.27 degrees for tilt measurement.

A Study on Computer Aided Surgical Simulation Method for Total Hip Arthroplasty (컴퓨터 응용 인공고관절 모사 시술 방법 연구)

  • Kim Sang Hoo;Han Seung Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.455-464
    • /
    • 2004
  • Total hip arthroplasty(THA) considerably depends on high-experienced doctors because of high difficulty of the operation. Selection of acetabular cup's and femoral implant's position is closely related with success or failure of THA. Nevertheless the selection has usually depended on doctor's eye measurement, which makes the position accuracy of artificial joint lower after THA, often resulting in revision of THA. The present study determined a method to select accurately the position of acetabular cup and femoral implant through surgical simulation with 3D characteristic geometrical information of patient's pelvis and femur. We examined the change of femoral anteversion angle and neck-shaft angle accompanied by the change of acetabular cup's position and the insertion position of femoral implant. As result of analyzing geometrical information through different surgical simulations, we found that it was possible to select the accurate position of acetabular cup and femoral implant. It is expected to help doctors get experienced in THA operation through repetitive surgical simulations using the method suggested in the study.

Mechanical safety evaluation of ceramic ball head for total hip replacement using finite element method (인공고관절 전치환술에서 세라믹 볼 헤드의 기계적 안정성 평가를 위한 유한요소 해석)

  • Han, Sung-Min;Chu, Jun-Uk;Chun, Heoung-Jae;Kim, Jung-Sung;Choi, Kui-Won;Youn, In-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.6
    • /
    • pp.449-455
    • /
    • 2010
  • A ceramic articulating system in total hip replacement thought to be superior to metal-on-polyethylene due to its extremely low coefficient of friction and potential for high resistance to wear. But ceramic is brittle, which makes it mechanically and theoretically susceptible to fracture under certain mechanical conditions. In the current study, nine different models of ceramic ball heads were mechanically evaluated using 3D finite element(FE) analyses. It was found that the maximum stress in all ceramic models was lower than ceramic flexural strength, and it satisfied the requirements of the FDA Gaudience for artificial hip implant. Thus, ceramic ball head models introduced in the current study could be mechanically safe for clinical applications.

Intermediate-Term Clinical Outcomes after Total Ankle Arthroplasty for End-Stage Rheumatoid Arthritis with Modification of Perioperative Anti-Rheumatic Medication (말기 류마티스성 발목관절염에 대한 인공관절 전치환술 및 항류마티스 약물 조절 후의 중기 추시 임상 결과)

  • Cho, Byung-Ki;Ko, Ban-Suk
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.3
    • /
    • pp.91-99
    • /
    • 2019
  • Purpose: This retrospective study reports the intermediate-term clinical outcomes including the practical function in daily and sports activities after total ankle arthroplasty for end-stage rheumatoid arthritis, as well as the effects of modification of perioperative anti-rheumatic medications. Materials and Methods: Twelve patients were followed for a minimum of 2 years after total ankle replacement for end-stage rheumatoid arthritis. Perioperative anti-rheumatic medications in all patients were modified based on a specific guideline. Clinical evaluations consisted of American Orthopaedic Foot and Ankle Society (AOFAS) scores, Foot and Ankle Outcome Score (FAOS), and Foot and Ankle Ability Measure (FAAM) scores. Periodic radiographic evaluation was conducted to detect changes in ankle alignment and postoperative complications. Results: Mean AOFAS, FAOS, and FAAM scores improved significantly from 37.5 to 81.2, 39.1 to 72.4, and 33.8 to 64.0 points at final follow-up, respectively (p<0.001). Functional outcomes in daily and sports activities at final follow-up were found to be 76.5 and 55.8 points for the FAOS and 70.5 and 57.5 points for the FAAM, respectively. As early postoperative complications, there was one case of local wound necrosis, one case of medial malleolar fracture, and one case of deep peroneal nerve injury. Radiological evaluation revealed two cases of asymptomatic heterotopic ossification and one case of progressive arthritis in the talonavicular joint. Reoperation was performed in only one patient (8.3%) with a medial soft tissue impingement at a mean of 35.6 months follow-up. Conclusion: Total ankle arthroplasty appears to be an effective surgical option for end-stage rheumatoid arthritis. Practical functions in daily and sports activities were significantly improved at intermediate-term follow-up. Modification of perioperative anti-rheumatic medications can be one of the solutions to reduce the postoperative complication rate.

3-D Finite Element Analysis of Acetabular Reconstruction of THR (인공고관절 전치환술에 있어서 비구 재건 술에 관한 3차원 유한요소해석)

  • Ryu, J.C.;Mun, M.S.;Kim, G.S.;Yoo, M.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.34-38
    • /
    • 1995
  • Using a 3-D finite element method (FEM), the biomechanical characteristics of a threaded truncated acetabular component and a porous coated hemispherical acetabular component were studied. The Von-Mises stress/strain patterns in the acetabulum reconstructed with these two different types of cementless acetabular cups were investigated. The geometry and dimensions of human hemi-pelvis used in the present shape modeling for finite element analysis were scanned with a 3-D laser scanner(TDS-9000, Cyberware, USA). The scanned data was numerically handled with a shape modelling software 'Pro-Engineer'. Using 19836, 16853 tetrahedral elements, respectively, the stress and displacement field of the acetabulum reconstructed with the two different types of the acetabular components were computed. While the hemi-sphere component was found to show a relatively similar stress/strain patterns to those in the normal hip, the results with the threaded cup showed a considerably different patterns from those in the normal condition. Several regions in cancellous bone near the threads and the edge of the truncated cup was found to be overstressed, especially in the superior-lateral part of the acetabulum. It was postulated that the excessive reaming-out of subchondral bone layer when the truncated cup was used can cause the presence of these overstressed regions of cancellous bone. This theoretical prediction for the implanted acetabulum appeared to consistent with the pathological observation of proximal/medial migration of the threaded truncated acetabular prostheses in the previous publications.

  • PDF