• Title/Summary/Keyword: 이중 주파수

Search Result 724, Processing Time 0.024 seconds

One dimensional inhomogeneous aperture modulation effects on the MTF of optical system II (일차원적 비균일 개구변조시 광학계의 최적상면 MTF에 미치는 영향)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.277-281
    • /
    • 1998
  • One dimensional inhomogeneous aperture modulation effects on the MTF of optical system was investigated. The lens under test was a doublet made in Korea. It has 10 mm effective diameter, 87.8 mm effective focal length. The ray-fans and spot diagrams were calculated and presented on the picture for on-axis and off-axis (field of view, $1^{\circ}$ and $2^{\circ}$). Aperture modulation was carried out by positioning a aperture modulator close contacter with the lens under test. We bought two modulators from Edmud Company in U.S.A. One was linear type and the other was stepped type. The MTFs were measured on the best of focus for each modulated aperture where the MTF has the highest value for 60 line/mm and were compared with one another. For on-axis, the MTFs of some modulated apertures had higher values than the MTF of unmodulated aperture in the high frequency region. In the case of off-axis, at the field of view $1^{\circ}$, the MTF values of some modulated aperture are improved prominently and some other one are disimproved. At the field of view $2^{\circ}$ most of the MTFs of modulated apertures had lower values than the MTF of unmodulated aperture except the MTFs of linear and inverse linear type aperture in the high frequency area. But the values of MTFs in high frequency region were too low for actual use.

  • PDF

Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve (기계식 인공판막 상태 평가를 위한 컴퓨터 보조진단 시스템)

  • 이혁수
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.421-430
    • /
    • 2004
  • Clinically, it is almost impossible for a physician to distinguish subtle changes of frequency spectrum by using a stethoscope alone especially in the early stage of thrombus formation. Considering that reliability of mechanical valve is paramount because the failure might end up with patient death, early detection of valve thrombus using noninvasive technique is important. Thus the study was designed to provide a tool for early noninvasive detection of valve thrombus by observing shift of frequency spectrum of acoustic signals with computer aid diagnosis system. A thrombus model was constructed on commercialized mechanical valves using polyurethane or silicon. Polyurethane coating was made on the valve surface, and silicon coating on the sewing ring of the valve. To simulate pannus formation, which is fibrous tissue overgrowth obstructing the valve orifice, the degree of silicone coating on the sewing ring varied from 20%, 40%, 60% of orifice obstruction. In experiment system, acoustic signals from the valve were measured using microphone and amplifier. The microphone was attached to a coupler to remove environmental noise. Acoustic signals were sampled by an AID converter, frequency spectrum was obtained by the algorithm of spectral analysis. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. A return map was applied to evaluate continuous monitoring of valve motion cycle. The in-vivo data also obtained from animals with mechanical valves in circulatory devices as well as patients with mechanical valve replacement for 1 year or longer before. Each spectrum wave showed a primary and secondary peak. The secondary peak showed changes according to the thrombus model. In the mock as well as the animal study, both spectral analysis and 3-layer neural network could differentiate the normal valves from thrombosed valves. In the human study, one of 10 patients showed shift of frequency spectrum, however the presence of valve thrombus was yet to be determined. Conclusively, acoustic signal measurement can be of suggestive as a noninvasive diagnostic tool in early detection of mechanical valve thrombosis.

A Study of Sound Expression in Webtoon (웹툰의 사운드 표현에 관한 연구)

  • Mok, Hae Jung
    • Cartoon and Animation Studies
    • /
    • s.36
    • /
    • pp.469-491
    • /
    • 2014
  • Webtoon has developed the method that makes it possible to express sound visually. Also we can also hear sound in webtoon through the development of web technology. It is natural that we analyze the sound that we can hear, but we can also analyze the sound that we can not hear. This study is based on 'dual code' in cognitive psychology. Cartoonists can make visual expression on the basis of auditive impression and memory, and readers can recall the sound through the process of memory and memory-retrieval. This study analyzes both audible sound and inaudable sound. Concise analysis owes the method to film sound theory. Three main factor, Volume, pitch, and tone are recognized by frequency in acoustics. On the other hand they are expressed by the thickness and site of line and image of sound source. The visual expression of in screen sound and off screen sound is related to the frame of comics. Generally the outside of frame means off sound, but some off sound is in the frame. In addition, horror comics use much sound for the effect of genre like horror film. When analyzing comics sound using this kinds of the method film sound analysis, we can find that webtoon has developed creative expression method comparing with simple ones of early comics. Especially arranging frames and expressing sound following and vertical moving are new ones in webtoon. Also types and arrangement of frame has been varied. BGM is the first in using audible sound and recently BGM composed mixing sound effect is being used. In addition, the program which makes it possible for readers to hear sound according to scroll moving. Especially horror genre raise the genre effects using this technology. Various methods of visualizing sound are being created, and the change shows that webtoon could be the model of convergence in contents.

Improvement of Energy Density in Supercapacitor by Ion Doping Control for Energy Storage System (에너지 저장장치용 슈퍼커패시터 이온 도핑 제어를 통한 에너지 밀도 향상 연구)

  • Park, Byung-jun;Yoo, SeonMi;Yang, SeongEun;Han, SangChul;No, TaeMoo;Lee, Young Hee;Han, YoungHee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.209-213
    • /
    • 2019
  • Recently, demand for high energy density and long cycling stability of energy storage system has increased for application using with frequency regulation (F/R) in power grid. Supercapacitor have long lifetime and high charge and discharge rate, it is very adaptable to apply a frequency regulation in power grid. Supercapacitor can complement batteries to reduce the size and installation of batteries. Because their utilization in a system can potentially eliminate the need for short-term frequent replacement as required by batteries, hence, saving the resources invested in the upkeep of the whole system or extension of lifecycle of batteries in the long run of power grid. However, low energy density in supercapacitor is critical weakness to utilization for huge energy storage system of power grid. So, it is still far from being able to replace batteries and struggle in meeting the demand for a high energy density. But, today, LIC (Lithium Ion Capacitor) considered as an attractive structure to improve energy density much more than EDLC (Electric double layer capacitor) because LIC has high voltage range up to 3.8 V. But, many aspects of the electrochemical performance of LIC still need to be examined closely in order to apply for commercial use. In this study, in order to improve the capacitance of LIC related with energy density, we designed new method of pre-doping in anode electrode. The electrode in cathode were fabricated in dry room which has a relative humidity under 0.1% and constant electrode thickness over $100{\mu}m$ was manufactured for stable mechanical strength and anode doping. To minimize of contact resistance, fabricated electrode was conducted hot compression process from room temperature to $65^{\circ}C$. We designed various pre-doping method for LIC structure and analyzing the doping mechanism issues. Finally, we suggest new pre-doping method to improve the capacitance and electrochemical stability for LIC.