• Title/Summary/Keyword: 이종세

Search Result 643, Processing Time 0.029 seconds

Elastic Interactive Shear Buckling Behavior of Trapezoidally Corrugated Steel Webs (제형파형강판 복부판의 탄성 연성전단좌굴 거동)

  • Yi, Jong Won;Gill, Heung Bae;Lee, Hak Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.6 s.79
    • /
    • pp.707-715
    • /
    • 2005
  • Corrugated webs have been used for composite prestressed concrete box girder bridges. Innovative steel plate girders using corrugated webs have been proposed. It has been found that analytical and experimental researches conducted to determine the strength of trapezoidally corrugated webs can fail with respect to three different buckling modes: local, global, and interactive shear buckling. Shear buckling capacity equations based on classical and orthotropic plate buckling theories have been proposed,but these equations show some differences. In this paper, geometric parameters that influence interactive shear buckling behavior with interaction effects are identified via extensive bifurcation buckling analysis using the finite element meth.

POCS Based Interpolation Method for Irregularly Sampled Image (불규칙한 샘플 영상에 대한 POCS 기반 보간법)

  • Lee, Jong-Hwa;Lee, Chul-Hee
    • Journal of Broadcast Engineering
    • /
    • v.16 no.4
    • /
    • pp.669-679
    • /
    • 2011
  • In this paper, we propose a POCS based irregularly sampled image interpolation method exploiting non-local block-based wavelet shrinkage denoising algorithm. The method provides convex sets to improve the performance. The Delaunay triangulation interpolation is first applied to interpolate the missing pixels of the irregularly sampled image into the regular grids. Then, the non-local block-based wavelet shrinkage denoising algorithm is applied, and the originally observed pixels are enforced. After iteration is performed, the denoising algorithm for non-edge areas is applied to acquire the final result. The experimental results show that the proposed method outperforms the conventional methods.

Estimation of Reference Evapotranspiration Based on Remote Sensing: Nakdong River Hydrologic Survey (원격탐사 기반 기준 증발산 산정 모의: 낙동강 유역조사 분석)

  • Sur, Chan-Yang;Lee, Jong-Jin;Park, Jae-Young;Choi, Min-Ha
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.67-70
    • /
    • 2012
  • 현재 국내외에서는 양질의 증발산을 관측하여 활용하기 위해 증발접시 (evaporation pan), 침루계 (lysimeter) 등을 이용하여 실측하거나 Flux Tower에서 Eddy covariance technique, Bowen ratio method 등을 이용하여 경험적으로 산정하고 있다. 이러한 방법으로 산정되는 증발산은 크게 두 분류로 나눌 수 있다. 일반적인 기후 상태에서 유역의 토양이 증발산에 방해를 받지 않을 정도로 충분히 물을 포함하고 있고, 식생이 조밀한 상태에서의 증발산량을 의미하는 잠재 증발산과 실제 산정치인 실제 증발산으로 나눌 수 있다 (Thornthwait, 1939). 본 연구에서는 유역의 잠재 증발산을 산정하여 실제 증발산과 비교를 통해 적용성을 확인하고자 한다. 잠재 증발산을 산정하는 방법은 Moderate Resolution Imaging Spectroradiometer (MODIS) 인공위성 데이터를 이용한 원격탐사 기술을 적용하여 산정한다. 원격탐사 기술은 지상 관측의 단점을 보완한 것으로써, 날씨, 인간 활동 등 주변 외부 환경의 영향에 민감하게 반응하여 공간적인 분포 현황을 파악하는 것이 어려운 지상 관측의 한계점을 대체하기 위한 방법이다. 이들 방법으로는 가장 널리 쓰이는 Penman-Monteith (Penman, 1948; Monteith, 1965), 일별 최대, 최저, 평균 기온을 이용한 Hargreaves 방법 (Hargreaves, 1985)과 Priestley-Taylor 방법 (Priestley and Taylor, 1972) 등의 세 가지 방법을 소개하였다. 세 가지 방법으로 산정된 잠재 증발산을 통해 해당 유역의 잠재 증발산의 공간적인 거동을 파악해 볼 수 있다.

  • PDF

A Successful Decannulation Case Two Years Later A Tracheostomy (2년후에 발거가 가능했던 기관 cannula 발거곤란병)

  • 이종원;김종영;김성곤;권령춘;양한모
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1976.06a
    • /
    • pp.87.3-87
    • /
    • 1976
  • The authors experienced a case of a difficult decannulation in a 4 years old boy, in which. case decannulation was possible 2 years later a tracheostomy. Some immunoglogical phenomena could be considered in this case as though cancer can remiss spontaneously. Such complications of tracheostomy as subglottic edema and perichondritis could become relatively less troublesome to breathing during his aging process. And another reason for the easy decannulation is considered as the patient could be accustomed to breathing through natural air pathway by continual cannula corking training.

  • PDF

Risk Factors of Morbidity and Mortality after Coronary Artery Bypass Grafting (관상동맥우회로 이식술 후 이환과 사망의 위험요인)

  • 박창률;이응배;전상훈;장봉현;이종태;김규태
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1159-1164
    • /
    • 1998
  • Background: Although operative outcome is progressing due to the development of operative techniques and myocardial protection, some patients face an increased morbidity and mortality. Therefore, it has become increasingly important to predict the operative morbidity and mortality. Material and Method: This retrospective study reports the results of risk factor analysis of morbidity and mortality of 137 consecutive patients who were underwent coronary artery bypass graft surgery(CABG). Preoperative variables were age, sex, preoperative myocardial infarction, operative priority, left ventricular ejection fraction, obesity and triple vessel disease. Postoperative morbidities were arrhythmia, wound infection, cerebral infarction, prolonged postoperative hospitalization, pneumonia, acute renal failure, prolonged use of ventilator and operative death. Result: The mean age of total patients was 56.7 years, from 27 to 74. The overall mortality was 6.6%(9 of 137) with the mortality of 3.9%(5 of 128) for elective operation, and 44.4%(4 of 9) for emergent or urgent cases. The morbidity of patients over 65 years was stastistically higher than that of under 65 years. Sex distribution showed no difference in morbidity, however operative mortality rate was slightly higher in women (5/41, 12.19%) than in men(4/96, 4.17%). Morbidity of emergent or urgent operation was 100%, much higher than that of the elective operation. Mortality of the patients whose left ventricular ejection fraction was under 50% was higher than that of those over 50%. Conclusion: We concluded that the risk factors of morbidity after CABG were old age above 65 years and emergent or urgent operation, and that risk factors of mortality were low left venticular ejection fraction under 50% and emergent or urgent operation.

  • PDF

Active Control System for Mitigation of Cable Vibration in Cable-Stayed Bridges (사장교 케이블 진동저감을 위한 능동제어시스템)

  • Hwang, In-Ho;Jeong, Cheol-Oh;Lee, Jong-Han;Lee, Jong-Seh
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.557-563
    • /
    • 2007
  • Rain-wind induced cable vibration can cause serious problems in cable-stayed bridge. External dampers attached to the cables have become widely accepted as an effective means for stay-cable vibration suppression. For very long stay-cables, however, such damper systems are rendered ineffective, as the dampers need be attached near the end of cables for aesthetic reasons. A recent study by the authors proposed that a movable anchorage system is replaced direct fixed support of the cable with a support through a bearing and damper. This paper extends the previous work by adding active control system to mitigate the cable vibration. The response of a cable with the proposed active control system is obtained and then compared to those of the cable with and without an external passive damper. The results show that the active control system can provide superior protection than the passive control system for a cable vibration.

A Study on the Dynamic Behavior of Underground Tunnels with a Cavity (주변 공동을 고려한 터널의 동적거동에 관한 연구)

  • 김민규;이종우;이종세
    • Tunnel and Underground Space
    • /
    • v.12 no.3
    • /
    • pp.171-178
    • /
    • 2002
  • A dynamic analysis of a horseshoe_shaped tunnel near to cavity was performed to study the effect of the cavity on the dynamic behavior of the tunnel. In order to obtain the dynamic response of the tunnel embedded in a semi-infinite domain, a hybrid numerical technique was primarily developed. A dynamic fundamental solution in frequency domain for multi-layered half planes was derived and subsequently incorporated in the boundary element method. Coupling of the boundary element method for the far field with the finite element method for the near field is made by imposing compatibility condition of a displacement at the interface. The boundary element method is then coupled with the finite element method, which is utilized to model the near field including the tunnel and the cavity. In order to demonstrate the validity of the proposed technique, dynamic responses of single and multiply-layered semi-infinite structural systems are obtained by using the Kicker waveform and investigated in the limestone layer to find how the being and the location of the cavity affect the dynamic characteristics of the system.

A Design of Novel Compact Microstrip Bandstop Filters Based on Split-Ring Resonators and Spiral Resonators (Split-Ring 공진기와 Spiral 공진기를 이용한 새로운 소형의 마이크로스트립 대역 저지 필터 설계)

  • Lee, Jong-Hyuk;Oh, Young-Chul;Myung, Noh-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.796-808
    • /
    • 2007
  • In this paper, two novel compact microstrip bandstop filters using complimentary split ring resonators(CSRRs) and spiral resonators is proposed. The first one is the bandstop filter using an array of CSRRs etched on the center line of a microstrip. The bandstop is due to the presence of negative effective permittivity and positive permeability near resonant frequency which prevent the wave propagation. The second on is the bandstop filter using an array of spiral resonators etched on the center line of a microstrip. The bandstop is due to the self-resonance of spiral circuit. We have achieved controllable resonance frequency and bandwidth, super compact dimension, low insertion losses in the passband and high level of rejection in the stopband with sharp cutoff. The electrical sizes of two proposed filter are very small. Additionally, they can be easily fabricated and compatible with MMIC or PCB technology.

Evaluation of Buckling Strength of Surface Plates in Steel-Plate Concrete Walls with Studs and Tie-bars (스터드 및 타이바를 가진 강판콘크리트 벽체의 표면강판 좌굴강도 평가)

  • Koo, Jimo;Lee, Kyungkoo;Kim, Wonki;Lee, JongBo
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.3
    • /
    • pp.129-138
    • /
    • 2016
  • Buckling of surface plates is an important limit state in Steel-Plate Concrete (SC) walls under axial compression. The surface plates may be anchored to concrete using connectors of studs or tie-bars. In this paper, the effects of studs and tie-bars on buckling of surface plates were evaluated by conducting tests. Experiments have three types of connectors; all studs, all tie-bars, and the combination of studs and tie-bars. Also, experiments have the various ratios of stud or tie-bar spacing to surface plate thickness. The experimental investigation shows that the buckling shape and strength of the surface plate of SC wall with the combination of studs and tie-bars have good agreements with that of the surface plate of SC walls with all studs or all tie-bars.

A Comparison of Three Fixed-Length Sequence Generators of Synthetic Self-Similar Network Traffic (Synthetic Self-Similar 네트워크 Traffic의 세 가지 고정길이 Sequence 생성기에 대한 비교)

  • Jeong, Hae-Duck J.;Lee, Jong-Suk R.
    • The KIPS Transactions:PartC
    • /
    • v.10C no.7
    • /
    • pp.899-914
    • /
    • 2003
  • It is generally accepted that self-similar (or fractal) processes may provide better models for teletraffic in modern telecommunication networks than Poisson Processes. If this is not taken into account, it can lead to inaccurate conclusions about performance of telecommunication networks. Thus, an important requirement for conducting simulation studies of telecommunication networks is the ability to generate long synthetic stochastic self-similar sequences. Three generators of pseudo-random self-similar sequences, based on the FFT〔20〕, RMD〔12〕 and SRA methods〔5, 10〕, are compared and analysed in this paper. Properties of these generators were experimentally studied in the sense of their statistical accuracy and times required to produce sequences of a given (long) length. While all three generators show similar levels of accuracy of the output data (in the sense of relative accuracy of the Horst parameter), the RMD- and SRA-based generators appear to be much faster than the generator based on FFT. Our results also show that a robust method for comparative studies of self-similarity in pseudo-random sequences is needed.