• Title/Summary/Keyword: 이용저하

Search Result 6,869, Processing Time 0.037 seconds

New Concept of Average River Bed and General Trend of River Bed Change in the Nakdong River (새로운 평균하상 개념과 낙동강의 하상 변동 경향성 분석)

  • Yu, Kwon-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.6
    • /
    • pp.486-494
    • /
    • 2011
  • River bed change due to various factors in watershed and/or river environment would one of the most important issues in river management. To judge whether the river bed was aggrading or degrading, normally we use the change in thalweg or average bed, calculated using the design flood of the river. The present study is to figure out the problems of the existing methods and to propose a new concept of average river bed using annual maximum flood. To evaluate the new method, it was applied to the Nakdong River. We use the river bed data surveyed in 1983, 1993, and 2005. The results showed that there were no significant river bed change during 1983 and 1993, while the river bed was degraded significantly during 1993 and 2005. In the latter period, the river had severe degradations, 2~3 m in average sense and 5 m for the maximum in the middle reach(120~200 km from river mouth), and 1~2 m in average in the upper reach(200~240 km from river mouth). For the upstream reach of the confluence of the Naesung River(about 240 km from river mouth), most of the river bed change seemed to be only local phenomena. The main cause of the river bed change in the Nakdong River seems to be massive gravel mining in the middle reach of the river.

The Exploratory Research on Disability Thinking of the Geriatric Oral Health Care of Aged People Using Q Methodology (Q방법론을 이용한 노인구강관리의 불편함에 관한 탐색적 연구)

  • Yoon, Young-Suk
    • Journal of dental hygiene science
    • /
    • v.9 no.1
    • /
    • pp.91-98
    • /
    • 2009
  • The aging of Korean society is coming to the fore and its speed is unprecedented. Along with the volume rise in the population of the elderly, the rise of the elderly of means and high education stimulates the transition of our focus from "a desire of longevity" to "successful aging". The research objective is to classify groups by the different definitions of disability thinking of the geriatric oral health care. We targeted 34 aged people who live in Pusan Metropolis and analyzed the collected data and classified them into two types. The first type is the 'blunting of taste & oral pain' which is identified as a group. The second type is the 'blunting of taste & lowering quality of life' which is identified as a group. The common positive statements are 'There are some experiences to feel pain on and below tongue, cheek and upper palatine.', 'There are some experiences to feel unsatisfactory life'.

  • PDF

A Simple Evaluation Method for Shear Strength Decreasing with Increasing Number of Cyclic Loading (반복하중 증가에 따라 감소하는 전단강도의 간이 평가법)

  • Song, Byungwoong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.4
    • /
    • pp.57-65
    • /
    • 2007
  • Earthquake is one of the factors to affect the stability of geotechnical structures. Numerous past earthquakes have shown that earthquakes have taught that damage of soil structures could occur on fine soils as well as coarse soils. For that reason, earthquake-induced decreasing tendency for strength on both coarse and fine soils has been investigated using direct simple shear (DSS) tests in laboratory. Based on the testing results the decreasing tendency for strength on coarse and fine soils is clearly identified in terms of the concept of volume decrease potential and plasticity index, respectively. Most of the soils except the weathered soil have shown similar reduction tendency of strength with the increasing number of cycles. Liquefaction strength of coarse and fine soils appears to decrease with the increment of volume decrease potential and the decrement of plasticity index, respectively. Reduction of strength on the weathered soil is particularly remarkable rather than others, which might be owing to the collapse phenomenon. From the DSS test results for soils, proposed is a simple method to evaluate strength decrement with the increasing number of cycles, and it can help estimate decrement of strength with the number of cycles easily.

  • PDF

고온 및 고온고습 가속시험에 의한 CIGS PV 모듈의 열화거동

  • Lee, Dong-Won;Nam, Song-Min;Kim, Yong-Nam
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.421-421
    • /
    • 2012
  • Cu(In,Ga)$Se_2$ (CIGS) 화합물은 직접천이형 반도체로 열적으로 매우 안정하고 에너지밴드갭이 1.04 eV로 이상적인 값에 가깝고, 특히 높은 광흡수계수를 가지기 때문에 박막 태양전지로서 커다란 응용 잠재력을 갖고 있는 광흡수층 재료이다. CIGS 화합물 박막 태양전지의 효율은 연구실에서는 ~20%를 높은 효율을 보고하고 있으며, 모듈급에서도 ~13%의 효율을 보이고 있다. 그러나 CIGS 박막 태양전지를 대면적 또는 양산화에 적용하기 위해서는 20년 이상의 장기적인 수명을 보장할 수 있는 내구성을 갖추어야 한다. 본 연구에서는 CIGS 모듈의 장기적인 신뢰성을 평가하기 위해 CIGS PV 모듈을 대상으로 대표적인 고온 고습 조건인 IEC-61646 규격을 이용하여 $85^{\circ}C$/85% RH에서 1000시간 동안 가속시험이 수행되었고, 고온 환경하에서 모듈의 성능 저하에 미치는 영향을 고찰하기 위해 모듈을 $85^{\circ}C$에서 1000시간 노출시켰다. 두 종류의 가속 스트레스시험 후에 모듈들의 외형적인 노화현상 및 전기적 열화 성능을 분석하였다. 또한 모듈의 효율저하의 원인을 규명하기 위해 모듈 구성 재료 중 충진재료로 사용하는 EVA sheet와 투명전극 AZO를 대상으로 고장분석을 수행하였다. AZO의 미세구조 관찰, 결정상 분석, XPS 분석 및 전기적 분석과 EVA sheet의 FT-IR 분석과 TG-DSC 분석들을 종합하여 CIGS PV 모듈의 성능저하의 원인을 규명하였다.

  • PDF

Effect of Mechanical Restraint due to Steel Microfibers on Alkali-Silica Reaction in Mortars (미세 강섬유의 구속력이 모르타르의 알칼리-실리카 반응에 미치는 영향)

  • Yi, Chong-Ku
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.577-584
    • /
    • 2007
  • The effect of steel microfibers (SMF) on alkali-silica reaction (ASR) was investigated using two types of reactive aggregates, crushed opal and a pyrex rod of constant diameter. Cracks are less visible in the SMF mortars compared with the unreinforced mortars. Due to crack growth resistance behavior in SMF mortar specimens, the strength loss is eliminated and the ASR products remained well confined within the ASR site. The expansion and the ASR products were characterized by microprobe analysis and inductively coupled plasma (ICP) spectroscopy. The confinement due to SMF resulted in a higher Na and Si ion concentration of the ASR liquid extracted from the reaction site. The higher concentration reduced the ASR rate and resulted in a lower reactivity of the reactive pyrex rods in SMF mortars.

Evaluation of the Residual Strength of CFRP Composite Pressure Vessel After Low Velocity Impact (CFRP 복합재압력용기의 충격후 잔류강도저하특성 평가)

  • Park, Jae-Beom;Kim, Dong-Ryun;Hwang, Tae-Kyung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.439-442
    • /
    • 2009
  • In this study, the residual strength of CFRP filament winding pressure vessel after low velocity impact was evaluated quantitatively. After impact test, the pressure vessel was sectioned to produce 25 mm-wide ring specimen and the bursting pressure of this specimen was measured. A finite element model was also fabricated to investigate the deformation and stress distribution characteristics of the impacted CFRP vessel. The degradation of the residual strength along with the increase of impact energy was successfully measured and reviewed.

  • PDF

A Case of Chronic Monocular Solar Retinopathy (만성 단안 일광망막병증 1 예)

  • Chang, Woo-Hyok
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.329-332
    • /
    • 2007
  • Solar retinopathy is a rare but well-recognized clinical entity of macular damage, caused by viewing a solar eclipse or direct sun gazing. A 21-year-old man gazed at the sun for approximately thirty seconds at noon using a monocular telescope with his left eye. Forty-eight hours after sun gazing, the patient experienced symptoms of blurred vision and central scotoma in the left eye. Eight months after sun gazing, the visual acuity decreased from 1.0 to 0.1 in the left eye and the fundus examination showed a round, yellowish-white discoid lesion at the left fovea. Fluorescein angiography showed an early window defect in the fovea of the left eye, that persisted without size change during the late phase resulting from atrophy of the retinal pigment epithelium. A small, central scotoma of the left eye was also found in the visual field test. The visual acuity was unchanged at the end of a one-year follow-up period.

  • PDF

10 nm 이하의 낸드 플래시 메모리 소자의 셀 간섭에 의한 전기적 특성 변화

  • Yu, Ju-Tae;Kim, Tae-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.301.1-301.1
    • /
    • 2014
  • 모바일 전자기기 시장의 큰 증가세로 인해 플래시 메모리 소자에 대한 수요가 급격히 증가하고 있다. 특히, 저 전력 및 고집적 대용량 플래시 메모리의 필요성이 커짐에 따라 플래시 메모리 소자의 비례축소에 대한 연구가 활발히 진행되고 있다. 하지만 10 nm 이하의 게이트 크기를 가지는 플래시 메모리 소자에서 각 셀 간의 간섭에 의한 성능저하가 심각한 문제가 되고 있다. 본 연구에서는 10 nm 이하의 낸드 플래시 메모리 소자에서 인접한 셀 간의 간섭으로 인해 발생하는 전기적 특성의 성능 저하를 관찰하고 메커니즘을 분석하였다. 4개의 소자가 배열된 낸드플래시 메모리의 전기적 특성을 3차원 TCAD 시뮬레이션을 툴을 이용하여 계산하였다. 인접 셀의 프로그램 상태에 따른 측정 셀의 읽기 동작과 쓰기 동작시의 전류-전압 특성을 게이트 크기가 10 nm 부터 30 nm까지 비교하여 동작 메커니즘을 분석하였다. 게이트의 크기가 감소함에 따라 플로팅 게이트에 주입되는 전하의 양은 감소하는데 반해 프로그램 전후의 문턱전압 차는 커진다. 플래시 메모리의 게이트 크기가 줄어듦에 따라 플로팅 게이트의 공핍영역이 차지하는 비율이 커지면서 프로그램 동작 시 주입되는 전하의 양이 급격히 줄어든다. 게이트의 크기가 작아짐에 따라 인접 셀 과의 거리가 좁아지게 되고 이에 따라 프로그램 된 셀의 플로팅 게이트의 전하가 측정 셀의 플로팅 게이트의 공핍영역을 증가시켜 프로그램 특성을 나쁘게 한다. 이 연구 결과는 10 nm 이하의 낸드 플래시 메모리 소자에서 인접한 셀 간의 간섭으로 인해 발생하는 전기적 특성의 성능 저하와 동작 메커니즘을 이해하고 인접 셀의 간섭을 최소로 하는 소자 제작에 많은 도움이 될 것이다.

  • PDF

Structural and Electrical Properties of Cu(In,Ga)Se2 Solar Modules under Damp Heat and Thermal Cycling Tests

  • Lee, Dong-Won;Kim, Yong-Nam;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.456.2-456.2
    • /
    • 2014
  • Cu(In,Ga)Se2 (CIGS) 화합물은 태양광을 흡수하기에 가장 이상적인 약 1.04 eV의 에너지 금지대 폭과 높은 광흡수계수를 가지고 있으며, $450{\sim}590^{\circ}C$의 고온 공정에도 매우 안정하여 열 경화현상을 거의 보이지 않으므로 박막 태양전지로서 커다란 응용 잠재력을 갖고 있는 광흡수층 재료이다. CIGS 화합물 박막 태양전지의 효율은 연구실에서는 ~20%의 높은 효율을 보고하고 있으며, 모듈급에서도 ~13%의 효율을 보이고 있다. 그러나 CIGS 박막 태양전지를 대면적 또는 양산화에 적용하기 위해서는 20년 이상의 장기적인 수명을 보장할 수 있는 내구성을 갖추어야 한다. 본 연구에서는 CIGS 모듈의 장기적인 신뢰성을 평가하기 위해 CIGS PV 모듈을 대상으로 IEC-61646 규격을 이용하여 고온고습 시험 ($85^{\circ}C$/85% RH, 1000 h) 과 열충격 시험 ($-40^{\circ}C/140^{\circ}C$, 1000 cycles) 이 수행되었고, 두 종류의 가속 스트레스 시험 후에 모듈의 성능 저하에 영향을 미치는 요인들이 연구되었다. 또한, 모듈의 효율 저하의 원인을 규명하기 위해 투명전극 Al-doped ZnO (AZO)와 광흡수층 CIGS를 대상으로 고장분석을 수행하였다. AZO층과 CIGS층의 전기적 특성 분석, 결장상 분석 및 XPS 분석들을 종합하여 CIGS PV 모듈의 성능저하의 원인을 규명하였다.

  • PDF

On the Performance Degradation Characteristics of High-Speed Enterprise Network (고속 엔터프라이즈 네트워크에서 성능 저하 특성 규명)

  • Ju, Hong-Taek;Hong, Seong-Cheol;Hong, James Won-Ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11B
    • /
    • pp.1225-1233
    • /
    • 2009
  • ISPs and Enterprises are equipping their networks with sufficiently high speed facilities and provide large bandwidths members. However the high speed enterprise network does not have satisfying end-to-end network performance within the network in spite of under utilization. The root cause of this performance degradation is a micro-congestion, which is a short-live event of traffic congestion. A micro-congestion causes packet loss, delay and packet reodering, and finally results in end-to-end network performance degradation. In this paper, we propose a micro-congestion detection method and find out the characteristics of performance degradation by analyzing traffic archives which is collected from a network link when a micro-congestion occurs.