• Title/Summary/Keyword: 이온챔버

Search Result 104, Processing Time 0.033 seconds

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

Cesium Sorption to Granite in An Anoxic Environment (무산소 환경에서의 화강암에 대한 세슘 수착 특성 연구)

  • Cho, Subin;Kwon, Kideok D.;Hyun, Sung Pil
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.2
    • /
    • pp.101-109
    • /
    • 2022
  • The mobility and transport of radioactive cesium are crucial factors to consider for the safety assessment of high-level radioactive waste disposal sites in granite. The retardation of radionuclides in the fractured crystalline rock is mainly controlled by the hydrochemical condition of groundwater and surface reactions with minerals present in the fractures. This paper reports the experimental results of cesium sorption to the Wonju Granite, a typical Mesozoic granite in Korea, performed in an anaerobic chamber that mimics the anoxic environment of a deep disposal site. We measured the rates and amounts of cesium (133Cs) removed by crushed granite samples in different electrolyte (NaCl, KCl, and CaCl2) solutions and a synthetic groundwater solution, with variations in the initial cesium concentration (10-5, 5×10-6, 10-6, 5×10-7 M). The cesium sorption kinetic and isotherm data were successfully simulated by the pseudo-second-order kinetic model (r2= 0.99) and the Freundlich isotherm model (r2= 0.99), respectively. The sorption distribution coefficient of granite increased almost linearly with increasing biotite content in granite samples, indicating that biotite is an effective cesium scavenger. The cesium removal was minimal in KCl solution compared to that in NaCl or CaCl2 solution, regardless of the ionic strength and initial cesium concentration that we examined, showing that K+ is the most competitive ion against cesium in sorption to granite. Because it is the main source mineral of K+ in fracture fluids, biotite may also hinder the sorption of cesium, which warrants further research.

Nano-Indentation 분석 기법을 활용한 플라즈마 식각 후 박막 표면의 물성 변화를 기반으로 정량적인 damage 제시 연구

  • Kim, Su-In;Lee, Jae-Hun;Kim, Hong-Gi;Kim, Sang-Jin;Seo, Sang-Il;Kim, Nam-Heon;Lee, Chang-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.177.1-177.1
    • /
    • 2015
  • 플라즈마 건식 식각공정은 반도체 공정에 있어 증착 및 세정 공정과 함께 중요한 공정중 하나이다. 기존 연구에서는 높은 식각 속도, 종횡비, 대면적에 대한 균일도 증가를 위하여 플라즈마 이온 밀도의 증가와 전자 온도를 감소시키기 위한 노력을 하고 있으며 플라즈마 식각분석 연구에서는 분광학 분석 기법을 활용하여 플라즈마에 의하여 활성화된 식각 가스와 박막 표면의 반응 메커니즘 연구가 진행 중에 있다. 그러나 지금까지의 플라즈마 식각연구에서는 플라즈마 식각 공정에서 발생되는 박막의 damage에 대한 연구는 전무하다. 본 연구에서는 플라즈마 식각과정에서 발생되는 박막 표면의 damage 연구를 위하여 Nano-indenter에 의한 분석 기법을 제시하였다. Nano-indentation 기법은 박막 표면을 indenter tip으로 직접 인가하여 박막 표면의 기계적 특성을 분석하고 이를 통하여 플라즈마에 의한 박막 표면의 물성 변화를 정량적으로 측정한다. 실험에서 플라즈마 소스는 Adaptively Coupled Plasma (ACP)를 사용하였고 식각 가스로는 HBr 가스를 주로 사용하였으며, 플라즈마 소스 파워는 1000 W로 고정 하였다. 연구 결과에 의하면 식각공정 챔버 내 압력이 5, 10, 15 및 20 mTorr로 증가함에 따라 TEOS SiO2 박막의 강도가 7.76, 8.55, 8.88 및 6.29 GPa로 변화되는 것을 측정하였고 bias power에 따라서도 다르게 측정됨을 확인하였다. 이 결과를 통하여 Nano-indentation 분석 기법을 활용하여 TEOS SiO2 박막의 식각공정의 변화에 따른 강도변화를 측정함으로써 플라즈마에 의한 박막 표면의 damage를 정량적으로 측정 가능함을 확인하였다.

  • PDF

최적화알고리듬을 이용한 세기변조방사선치료의 정량적인 정도관리

  • Park, Dong-Hyun;Park, Dal;Park, Sung-Yong;Kim, Tae-Hyun;Shin, Kyung-Hwan;Kim, Dae-Yong;Cho, Kwan-Ho
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.35-35
    • /
    • 2003
  • 목적 : 세기변조방사선치료의 정도관리 중 선량 분포의 비교에 관한 새로운 정량적인 방법을 제시하였다. 이 과정 중에서 선량의 기울기가 큰 영역에서의 문제점을 해결하기 위하여 최적화 알고리듬을 사용하였다. 대상 및 방법 : 필름을 통해 측정된 선량분포와 컴퓨터를 통해 구해진 선량분포를 각각 5mm 간격과 lmm 간격의 해상도로 컴퓨터를 이용해 2 차원 선량분포로 구현한다. 그 후 두 선량분포사이의 차이를 각 선량분 포의 원점을 일치시킨 후 구해낸다. 이때 일반적으로 두 선량분포 사이의 차이는 선량의 기울기가 큰 영역에서 상당히 크게 나타나게 되는데 이것은 측정 장비의 원점을 구하는 과정에서 발생되는 이차원 상의 미세한 원점의 불일치 효과로 선량의 차이가 선량의 기울기가 큰 영역에서 더욱 커지기 때문이다. 이 불일치를 보정하기 위해서, 측정된 선량분포를 계산된 선량분포 위에서 lmm 간격으로 이동시켜가면서 선량의 차이를 계산하여 이 값이 최소가 되는 위치를 확인한다. 이때의 이동치는 가속기가 갖는 허용오차 이내에 있어야 하며 이 값은 2mm로 알려져 있다. 이 과정과는 독립적으로 이온 챔버를 통해 측정된 절대선량 값을 이용하여 두 선량분포 사이를 재 규격화한 뒤 차이를 구하게 되면 우리는 5mm 간격의 2 차원 절대선량 분포 비교를 실험상의 오차들 중 가장 크게 작용하는 원점 오차로 인한 오차를 제거한 뒤 수행한 것과 같은 결과를 얻게 된다. 여기서 계산된 선량분포의 해상도는 장비의 허용오차 보다 항상 작아야 한다. 결과 : 머리와 목에 환부를 갖는 여러 환자들에 대한 선량분포 비교 결과를 통해서, 측정된 선량분포와 계산된 선량분포사이의 허용오차 범위에 대한 일시적 기준을 마련하였다. 이 기준은 물론 더 많은 환자들에 대한 선량분포 비교를 통해 개선되어질 수 있다. 결론 : 측정 장비의 원점 불일치의 보정뿐만 아니라 측정 장비의 회전에 의한 오차 보정, 필름의 광학적 밀도에 관한 보정 등 여러 가지 계통적 오차들에 대한 보정들이 선량분포 확인과정의 이해와 그 기준마련에 도움이 되겠지만 우리가 다룬 원점 불일치에 비해서 상대적으로 무시할 수 있었다. 마지막으로 선량분포 확인의 최종목표인 3 차원 선량분포 확인의 실제 적용을 위한 연구가 최적화 알고리듬을 이용하여 실험 중에 있다.

  • PDF

Fabrication of Biomimetic MEMS Acoustic Sensor and Analysis of Its Frequency Characteristics (MEMS 기반 생체모사 음향센서 제작 및 주파수 특성 분석)

  • Hur, Shin;Jung, Young-Do;Lee, Young-Hwa;Song, Won-Joon;Kim, Wan-Doo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.522-528
    • /
    • 2011
  • Artificial basilar membranes made of PVDF(polyvinylidene fluoride) are manufactured using microfabrication processes. The mechanical behavior of PVDF artificial basilar membrane was measured to evaluate its performance as a mechanical frequency analyzer using scanning LDV(laser Doppler vibrometer). The experimental setup consists of the microfabricated artificial basilar membrane, a loud speaker connected to an amplifier for generating acoustic pressure of specific spectral pattern, and a scanning LDV with controlling unit for measuring the displacement of the membrane on the incoming acoustic stimulation. The microfabricated artificial basilar membrane was attached tightly upon a package containing a chamber which can be filled with silicone oil before placed on the experimental setup stage. The experiment results showed that the microfabricated artificial basilar membrane has a property as a mechanical frequency analyzer.

Laser Patterning of Vertically Grown Carbon Nanotubes (수직성장된 탄소나노튜브의 선택적 패터닝)

  • Chang, Won Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1171-1176
    • /
    • 2012
  • The selective patterning of a carbon nanotube (CNT) forest on a Si substrate has been performed using a femtosecond laser. The high shock wave generated by the femtosecond laser effectively removed the CNTs without damage to the Si substrate. This process has many advantages because it is performed without chemicals and can be easily applied to large-area patterning. The CNTs grown by plasma-enhanced chemical vapor deposition (PECVD) have a catalyst cap at the end of the nanotube owing to the tip-growth mode mechanism. For the application of an electron emission and biosensor probe, the catalyst cap is usually removed chemically, which damages the surface of the CNT wall. Precise control of the femtosecond laser power and focal position could solve this problem. Furthermore, selective CNT cutting using a femtosecond laser is also possible without any phase change in the CNTs, which is usually observed in the focused ion beam irradiation of CNTs.

Numerical modeling of Si/$SiO_2$ etching with inductively coupled CF4 plasma

  • Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.97-97
    • /
    • 2010
  • 많은 플라즈마 공정 중에 건식 식각은 복잡하고 표면반응이 잘 알려지지 않은 등의 이유로 가장 어려운 분야 중의 하나이다. 이러한 이유로 식각 장치 디자인뿐만 아니라 플라즈마를 이용한 건식 식각의 공정 조건은 수많은 시행착오를 통해 시도되어 왔다. 이런 문제들을 극복하기 위해 많은 연구자들에 의해서 다양한 방법과 tool을 이용해 모델링이 시도되고 있다. 본 연구에서는 $CF_4$ 가스를 이용한 유도결합 플라즈마에 의해 Si와 $SiO_2$를 식각하는 것을 상용 프로그램인 전산모사 유체역학 시뮬레이터인 CFD-ACE+를 이용하여 모델링했다. 150 mm 직경의 웨이퍼에 대한 모델은 식각 속도 실험결과와 비교 하였다. Ar의 경우 20 mTorr에서 13.56 MHz, 500 W인가 시 2.0 eV의 전자온도와 $7.3{\times}10^{11}\;cm^{-3}$의 전자밀도가 계산결과와 상당히 일치하게 측정되었고, $CF_4$를 이용한 $SiO_2$ 식각에서도 식각 속도가 평균 190 nm/min로 일치했고 식각 균일도는 3% 였다. 450 mm 웨이퍼 공정용 장치의 모델 계산 결과에서는 안테나와 기판의 거리, 챔버의 단면적, 기판 지지대와 배기구와의 높이 등 기하학적인 구조와 각 안테나 턴의 위치 및 전류비가 플라즈마 균일도에 많은 영향을 주었으며, 안쪽부터 4 turn이 있는 경우 2번째, 4번째 turn에만 1:4의 전류비를 인가했을 때, 수십%의 전자밀도의 불균일도를 4.7%까지 낮출 수 있었다. 또한, Si 식각에서는 식각 속도의 분포가 F radical의 분포와 같은 경향을 보임을 확인했고, $SiO_2$ 식각에서는 전자 밀도의 분포와 일치함을 확인함으로써 균일한 식각을 위해서 두 물질의 식각 공정에서는 다른 접근의 시도가 필요함을 확인했다. 플라즈마의 준중성 조건을 이용해서 Poisson 방정식을 풀지 않고 sheath를 해석적 모델로 처리하는 방법과, Poisson 식으로 정전기장을 푸는 방법을 통해서 입사 이온의 에너지 분포를 비교하였다. 에너지 범위는 80~120 eV로 같지만, 실험에서는 IED가 낮은 에너지 쪽이 더 높게 측정됐고, 계산 결과에서는 높은 에너지 쪽이 높았다.

  • PDF

Electronic properties of MgO films

  • Lee, Sang-Su;Chae, Hong-Cheol;Yu, Seu-Ra-Ma;Lee, Seon-Yeong;Gang, Hui-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.345-345
    • /
    • 2011
  • MgO는 암염구조를 가진 전형적인 이온 결합성 화합물로서 7.8eV의 띠틈을 갖고 흡습성이 강하다. 면 방전 구조 PDP에서 MgO 보호막은 면 방전으로 인한 유전층의 식각을 보호하고 2차 전자 방출을 통해 방전 전압을 낮추는 역할을 한다. 하지만 MgO 보호막은 증착시 흡수된 수분이 제거되어야 하고, 방전 특성 개선 및 방전 효율 향상을 위해 가공 처리에 관한 연구가 진행 되어야 한다. 본 연구는 MgO 보호막의 전자적 특성의 변화를 알아보기 위해 $O_2$ 분위기에서 전자빔 증착법을 이용해 MgO Powder를 사용하여 시료를 제작하였다. 표면에 흡착된 수분제거로 인한 특성 변화를 알아보기 위해 진공 챔버내에서 시료를 $500^{\circ}C{\sim}550^{\circ}C$의 열처리를 실시한 후 XPS(X-ray Photoelectron Spectroscopy), REELS(Reflection Electron Energy Loss Spectroscopy), UPS(Ultraviolet photoelectron Spectroscopy)를 이용하여 전자적 특성을 연구하였다. XPS 측정결과 시료의 열처리를 통해 C1s spectrum의 O-C=O(289eV) binding energy가 없어져 박막에 흡착된 불순물이 제거 되었으며 O1s spectrum에서 Hydroxides가 감소하고 530.0eV의 MgO 결합에너지쪽으로 커짐으로써 박막의 구조를 확인할 수 있었다. 그리고 $O^2$ 분위기에서 성장시킨 MgO 박막 기판을 열처리 후 REELS를 이용해 띠틈을 얻어보면 Ep=500eV에서 띠틈이 6.77eV, Ep=1500eV에서 띠틈이 7.33eV로 각각 측정되었다. Ep=500eV의 REELS 스펙트럼으로부터 산소 결함에 의한 표면 F Center는 4.22eV로 확인되었다.

  • PDF

Study of Mössbauer Spectroscopy for Iron Oxides Synthesized by Pulsed Wire Evaporation (PEW) (전기선폭발법으로 제조된 철산화물의 뫼스바우어분광연구)

  • Uhm, Young Rang
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.5
    • /
    • pp.135-139
    • /
    • 2014
  • Iron-oxide nanopowders were synthesized by a pulsed wire evaporation (PWE) in various ambient gas conditions. SEM measurement indicates that the spherical iron nanoparticles are about 50 nm in diameter. The phase analysis for the produced iron-oxide powders was systematically investigated by using $M\ddot{o}ssbauer$ spectra and the results show that classified phases of $Fe_2O_3$ and $Fe_3O_4$ can be controlled by regulating the oxygen concentration in the mixed gas during the PWE process. A quadrupole line on the center of $M\ddot{o}ssbauer$ spectrum represents the superparamagnetic phase of 12 % from ${\gamma}-Fe_2O_3$ phase.

Junction Area Dependence of Tunneling Magnetoresistance in Spin-dependent Tunneling Junction with Natural $Al_2O_3$Barrier (자연산화 $Al_2O_3$장벽층을 갖는 스핀의존 터널링 접합에서 자기저항특성의 접합면적 의존성)

  • 이긍원;이상석
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.5
    • /
    • pp.202-210
    • /
    • 2001
  • Spin dependent tunneling (SDT) junction devices of Ta/NiFe/Ta/NiFe/FeMn/NiFe/AlOx/CoFe/NiFe/Al with in-situ naturally oxidized Al barrier were fabricated using ion beam deposition and dc sputtering in UHV chamber of 10$^{-9}$ Torr. The maximum tunneling magnetoresistance (TMR) and the product resistance by junction (R$_{j}$ A) are 16-17% and 50-60 $\Omega$${\mu}{\textrm}{m}$$^2$, respectively. The values of TMR and (R$_{j}$ A) with field annealing were slightly increased. The TMR and (R$_{j}$ A) dependence versus the junction area size was observed. These results were explained by using sheet resistance effect of bottom electrode and spin channel effects.

  • PDF