• Title/Summary/Keyword: 이온빔

Search Result 676, Processing Time 0.037 seconds

The effect of different crystallization temperature of the hydroxyapatite coating produced by ion beam-assisted deposition on anodizing-treated titanium disks on human osteosarcoma cells (양극산화처리된 티타늄 표면에 이온빔보조증착방식을 이용한 수산화인회석 코팅시 소결온도의 차이가 조골세포에 미치는 영향)

  • Pae, Ah-Ran;Won, Hyun-Du;Lee, Richard Sung-Bok;Kim, Hyeong-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.333-340
    • /
    • 2011
  • Purpose: The aim of this study was to study the effect of hydroxyapatite (HA) coating crystallinity on the proliferation and differentiation of human osteosarcoma cells. Materials and methods: Surface roughness of the titanium disks increased by anodizing treatment and then HA was coated using ion beam-assisted deposition (IBAD). HA coating was crystallized by heat-treated at different temperature ($100^{\circ}C$, $300^{\circ}C$, $500^{\circ}C$, $800^{\circ}C$). According to the temperature, disks were divided into four groups (HA100, HA300, HA500, HA800). With the temperature, crystallinity of the HA coating was different. Anodized disks were used as control group. The physical properties of the disk surface were evaluated by surface roughness tests, XRD tests and SEM. The effect of the crystallinity of HA coating on HOS cells was studied in proliferation and differentiation. HOS cells were cultured on the disks and evaluated after 1, 3, 5, and 7 days. Growth and differentiation kinetics were subsequently investigated by evaluating cell proliferation and alkaline phosphatase activity. Results: Regardless of the heat-treated temperature, there is no difference on the surface roughness. Crystallinity of the HA was appeared in the groups of HA500, HA800. HOS cells proliferation, ALP activity were higher in HA500 and HA800 group than HA100 and HA300. Conclusion: Within the results of this limited study, heat treatment at $500^{\circ}C$ of HA coating produced by IBAD has shown greater effect on proliferation and differentiation of HOS cells. It is considered that further in vivo study will be necessary.

A Study on Characterization of Polyethylene Separators Irradiated at Various Electron Beam Current Conditions (다양한 전자선 전류 조건에서 조사된 폴리에틸렌 분리막의 특성 연구)

  • Im, Jong-Su;Sohn, Joon-Yong;Shin, Jun-Hwa;Lim, Youn-Mook;Choi, Jae-Hak;Kim, Jeong-Soo;Nho, Young-Chang
    • Polymer(Korea)
    • /
    • v.34 no.1
    • /
    • pp.74-78
    • /
    • 2010
  • In this paper, crosslinked polyethylene (PE) separators for lithium secondary batteries were prepared by an electron beam irradiation under various beam currents and dose rates. The crosslinking degree increased up to maximum 71% with an increasing absorption dose and with a decreasing beam current. The PE separators irradiated at lower beam currents showed better thermal shrinkage (51%) and mechanical properties than the original PE separator and PE separators irradiated at higher beam current. The ionic conductivity ($1.01{\times}10^{-3}\;S/cm$) and electrolyte uptake (275%) of the crosslinked PE separators were comparable to the original PE separator.

ITO, PR, 격벽 재료의 레이저 직접 미세가공

  • Lee, Cheon;Lee, Gyung-Chul;Ahn, Min-Young;Lee, Hong-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.80-80
    • /
    • 1999
  • 플라즈마 디스플레이 패널(PDP)의 공정을 간단히 하기 위하여 포토레지스트, ITO, 격벽재료를 Ar+ laser(λ-514 nm, CW)와 Nd:YAG laser(λ=532, 266nm, pulse)로 직접 패터닝 하였다. 레이저에 의한 포토레지스트의 패턴결과, 아르곤 이온 레이저의 포토레지스트 가공의 반응 메카니즘은 레이저 빔의 열에 의한 시료 표면의 국부적인 온도상승에 의한 용융작용이며, 그 결과 식각 후 형성된 패턴의 단면 모양도 레이저빔의 profile과 같은 가우시안 형태를 나타낸다. Nd:YAG 레이저의 4고조파(532nm)를 이용한 경우 200$\mu\textrm{m}$/sce의 주사속도에서 포토레지스트를 패턴하기 위한 임계에너지(threshold energy fluence) 값은 25J/cm2이며, 약 40J/cm2의 에너지 밀도에서 하부기판의 손상이 발생하기 시작하였다. 글미 1은 Nd:YAG 레이저 4고조파를 이용하여 포토레지스트를 식각한 경우 SEM 표면사진(위)과 단차특정기에 의한 단면형상(아래)이다. ITO 막의 레이저에 의한 직접 패턴 결과, ITO 막은 레이저 펄스에 의한 급속 가열 및 증발에 의한 메커니즘으로 식각이 이루어지며, 레이저 파장에 따른 광흡수 정도의 차이에 의해 2고조파 (532nm)에서 ITO 막의 가공 품질이 4고조파(266nm)에 비해 우수하며 패턴의 폭도 출력에 따라 제어가 용이하였다. 그림 2는 Nd:YAG 레이저 2고조파를 이용하여 ITO를 식각한 경우 SEM표면 사진(위)과 단차측정기에 의한 단면형상(아래)이다. 격벽 재료의 레이저에 의한 직접 패턴 결과, Ar+ 레이저(514nm)는 출력 밀도 32NW/cm2에서 격벽을 유리 기판의 경계면까지 식각하였다. Nd:YAG 레이저(532nm)는 laser fluence가 6.5mJ/cm2에서 격벽을 식각하기 시작하였으며, 19.5J/cm2에서 유리기판의 rudraus(격벽 두께 130$\mu\textrm{m}$)까지 식각하였다.

  • PDF

Recent Status of Commercial PET Cyclotron and KOTRON-13 (KOTRON-13과 상용 PET 사이클로트론의 최근 기술 동향)

  • Chai, Jong-Seo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • This paper is described on the development of KOTRON-13 and recent status of PET cyclotron by commercial cyclotron companies. KIRAMS has developed medical cyclotron which is KIRAMS-13. Samyoung Unitech produces KOTRON-13 with transfered technology by KIRAMS. As a part of Regional Cyclotron Installation Protect, KOTRON-13 cyclotrons and $[18F]FDG$ production modules are being installed at regional cyclotron centers in Korea. The medical concern with radiation technology has been growing for the last several years. Early cancer diagnosis through the cyclotron and PET-CT have been brought to public attention by commercial cyclotron models in the world. The new commercial cyclotron models are introduced compact low energy cyclotrons developed by CTI, GE, Sumitomo in recent. It produces different short-lived radioisotopes, such as $[^{18}F],\;[^{11}C],\;[^{13}N]\;and\;[^{15}O]$. For the better reliability acceleration particle is proton only. The characteristics of new model cyclotrons are changed to lower energy corresponding to less 13 MeV. New models have self-shielding and low power consumption. Design criteria for the different types of commercial cyclotrons are described with reference to hospital demands.

EFFECTS OF THE ION BEAM ASSISTED DEPOSITION OF HYDROXYAPATITE ON OSSEOINTEGRATION OF THE ENDOSSEOUS IMPLANTS IN RABBIT TIBIAE (이온빔 보조 전자빔 수산화 인회석 증착이 골내 임플란트의 골유착에 미치는 영향)

  • Jung, Young-Chul;Han, Chong-Hyun;Lee, In-Seop;Lee, Hyeon-Jeong;Kim, Myeong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.659-674
    • /
    • 2000
  • A large increase in the use of thin film coating of hydroxyapatite(HA) in implant dentistry is driven by the desire to take advantage of the excellent biocompatibility and high strength of HA coating. The purpose of this study was to evaluate the effects of HA-coated implants by ion Beam Assisted Deposition(IBAD) method in comparison to the sand-blasted and machined surfaces. Osteoblast culture test, removal torque test and histomorphometric analysis were performed and the following results obtained; 1. Examination of the osteoblast cultures displayed no difference in the secretion of alkaline phosphatase between the various specimen, but IBAD with pure HA specimen showed low alkaline phosphatase secretion(p<0.05). 2. Removal torque tests showed HA-coated implants by IBAD method to be similar in high value to the implants with sand-blasted surface than the implants with machined surface. And the ovariectomized group showed low mechanical test value than the normal group(p<0.05). 3. Histomorphometrical comparisons were performed on undecalcified ground sections. HA-coated implants by IBAD method demonstrated the highest mean bone-to-metal contact ratio on all threads and 3-best consecutive threads, and the implants with sand-blasted surface and implants with machined surface was in the next consecutive order(p<0.05). HA-coated implants showed slightly higher bone-to- metal contact ratio than sand-blasted implants, but no statistically significant difference was obtained between the two materials. The ovariectomized group showed lower value of bone-to-metal contact ratio than the normal group, but no statistically significant difference was obtained between the two groups. 4. Evaluation of bone volume on all threads and 3-best consecutive threads showed no statistically significant difference among the different surface treatment groups, but showed lower bone volume in ovariectomized group than in the normal group(p<0.05). According tn these results, thin film coated implants with HA showed high bone contact ratio, bone volume and removal torque strength in the short term, but long term observation is needed.

  • PDF

Acquisition of Monochromatic X-ray Using Multilayer Mirror (다층박막 거울을 이용한 단색 엑스선 획득)

  • Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.179-184
    • /
    • 2010
  • A hard X-ray microscope system for obtaining images of nano-spatial resolution has been widely studied and requires monochromatic X-ray. A multilayer mirror of 84% reflectivity was designed to acquire tungsten characteristic X-ray of 8.4 keV from the white beam generated from an X-ray tube, and the C/W multilayer mirror of $50{\times}50\;mm$ size and 5.65 nm d-spacing was fabricated by the ion-beam sputtering system. The C/W multilayer had a uniformity of 99.5%, and the structure of the multilayer mirror was verified by a TEM image. The obtainable x-ray reflectivity for the C/W multilayer mirror at 8.4 keV was estimated from measuring the X-ray reflectivity using the copper characteristic X-ray of 8.05 keV. Monochromatic X-ray of 8.4 keV was generated by combining a X-ray tube, and the reflectivity and monochromaticity were 77.1% and 0.21 keV, respectively. Monochromatic X-ray generated from the combination of an X-ray tube and an C/W multilayer mirror has enough potential to use X-ray source for hard X-ray microscope system of laboratory size. If the C/W multilayer mirror of d-spacing of a few nanometers can be fabricated, monochromatic X-ray corresponded to 17.5 keV, molybdenum characteristic X-ray, can be obtained and applied to mammography in the medical application.

A Study on the Film-Formation Mechanism by Ionized Cluster Beam Deposition (이온화 클러스터 빔 증착의 박막 형성 기구에 관한 연구)

  • Shin, C.B.;Lee, K.H.;Hwang, G.S.;Moon, S.H.;Cho, W.I.;Yun, K.S.
    • Applied Chemistry for Engineering
    • /
    • v.7 no.3
    • /
    • pp.464-472
    • /
    • 1996
  • The mechanism of thin-film formation by Ionized Cluster Beam Deposition(ICBD) was investigated. A simulation program based on the Monte-Carlo method was developed in order to investigate the effects of the acceleration voltage, substrate temperature, activation energy for the surface migration, and critical nuclei size on grain size and surface roughness. Studies of the effect of kinetic energy of clusters on the film formation processes revealed that high acceleration voltage enhanced the surface-migration of adatoms and made it easier for an epitaxial film to be formed. The relaxation time of kinetic energy of adatoms increased with the substrate temperature, which in turn increased the grain size of the crystalline film. This effect was more clearly distinguished when the critical nuclei size was large. The surface-migration activation energy was found to affect the interaction between the adatoms and the substrate and thus the relaxation time of kinetic energy. Investigations of the surface roughness revealed that the acceleration voltage, the substrate temperature, and the surface-migration activation energy exerted a collective effect on the morphology of the film surface.

  • PDF

Soft Magnetic Property Analysis of Nanocrystalline Fe-Al-O Film with the Change of Microstructure (나노 결정립 Fe-Al-O 산화막의 미세구조 변화에 따른 연자기적 특성 분석)

  • Lee, Young-Woo;Park, Bum-Chan;Kim, Chong-Oh;Moon, Ji-Hyun;Choi, Yong-Dae
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.2
    • /
    • pp.59-64
    • /
    • 2004
  • We investigated the soft magnetic properties of nanocrystalline Fe-Al-O film as etching the oxide film with ion beam etching method. It is thought that the grain size of Fe-Al-O film increases as the thickness decreases. The coercivity and squareness increase with decreasing thickness. The surface curvature of Am images increases when the etching experiment proceeds. This phenomena could be due to the grain growth which occurs during sputtering. This grain growth could be assisted by the the plasma energy during sputtering. Therefore proper thickness should be searched to acquire the good soft magnetic properties for the nanocrystalline film material. Good soft magnetic properties of Fe-Al-O film was acquired at the thickness of more than 900 nm.

Thermal Dewetting Process를 이용한 비주기 서브파장 구조물의 제작방법

  • Lee, Jong-Heon;Song, Yeong-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.346.1-346.1
    • /
    • 2016
  • 본 연구에서는 열처리(Thermal Dewetting Process)와 빗각 증착(Oblique angle deposition)을 이용하여 비주기 서브파장 구조물을 마이크로 렌즈 형태의 유리 기판 상부에 제작하였다. 먼저 $2{\times}2cm2$ 크기의 유리 기판에 기존 리소그래피 공정으로 원기둥 형태의 감광액을 형성한다. 이후 Hot-plate로 $180^{\circ}C$에서 90초간 열을 가해 지름이 $20{\mu}m$인 반구형태로 변형시킨 뒤 반응성이온식각 공정을 진행하여 마이크로 렌즈를 제작한다. 렌즈의 표면에 나방 눈 구조를 형성하기 위해 전자빔 증착으로 15nm의 은 박막을 쌓은 뒤 $500^{\circ}C$에서 1분간 열처리 공정을 진행하였다. 열이 가해졌을 때 은 박막은 표면자유에너지를 최소화하기 위해 나노 크기의 덩어리진 입자 형태로 변화한다. 여기서 형성되는 나노입자의 크기가 렌즈 표면 중심에서 가장자리로 갈수록 작아진다는 것을 주사전자현미경을 통해 확인하였다. 증착 각도가 증가할수록 열처리 공정 후의 은 나노입자의 크기가 점점 작아진다는 것을 검증하기 위해 은 박막의 증착 각도를 $0^{\circ}$, $35^{\circ}$, $55^{\circ}$, $70^{\circ}$로 증착 후 열처리 공정을 진행하여 확인하였다. 비스듬하게 증착되어 형성된 박막은 다공형태로 낮은 밀도를 가지는데 이는 박막 두께 감소를 일으킨다. 따라서 증착 각도가 증가할수록 열처리 공정 후의 은 나노입자의 크기는 점점 작아진다. 이후 은 나노입자를 마스크로 하여 다시 반응성이온식각 공정을 진행하였으며 식각 후 나머지 은 나노입자들은 HNO3용액에서 1분간 처리하여 제거하였다. 제작된 구조물의 평균 직경과 크기는 각각 ~220nm 및 ~250nm인 것으로 확인하였다. 위와 같은 공정을 통해 다양한 크기를 가진 비주기 서브파장 구조물을 제작할 수 있다. 구조물의 주기가 파장 길이보다 짧을 경우 분산이 최소화되며 넓은 파장 대역에서 무반사 효과를 얻을 수 있다. 이 공정은 마스크를 통한 리소그래피의 한계를 극복할 수 있으며 여러 곡면형 표면에 적용가능한 장점이 있다. 또한 프리즘, 렌즈, 광섬유와 같은 광소자의 광투과율을 향상시키는데 이용될 수 있다.

  • PDF

Effects of the Brazing Bonding between Al2O3 and STS304 with an Ion Beams (이온빔을 이용한 STS304와 알루미나 브레이징 접합효과)

  • Park, Il-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8679-8683
    • /
    • 2015
  • Using a surface modification technique, ion beam assisted deposition (IBAD) of Ti thin film it becomes possible to prepare an active ceramic surface to braze $Al_2O_3$-STS304 with conventional Ag-Cu eutectic composition filler metal. Researches on bonding formations at interfaces of ceramic joints were mainly related on the development of filler metals to ceramic, the process parameters, and clarifications of reaction products. From the results, the reactive brazing is a very convenient technique compared to the conventional Mn-Mo method. However melting point of reactive filler is still higher than that of Ag-Cu eutectic and it forms the brittle inter metallic compound. Recently several new approaches are introduced to overcome the main shortcomings of the reactive metal brazing in ceramic-metal, metal vapor vacuum arc ion source was introduced to implant the reactive element directly into the ceramics surface, and sputter deposition with sputter etching for the deposition of active material.