• Title/Summary/Keyword: 이슬 맺힘

Search Result 4, Processing Time 0.017 seconds

A Study on the Effect of Hot Lines and the Assembly of Flange for a Refrigerator to Reduce Dew Generation (냉장고 Flange부 이슬 맺힘 방지를 위한 열선의 영향 및 조립에 관한 연구)

  • Kim, Na Hyun;Cho, Jong Rae;Park, Sang Hu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.391-396
    • /
    • 2015
  • When the temperature of a flange in a refrigerator is reduced to the dew point, condensation is generated on the flange. Generally, hot lines, having a temperature of $35^{\circ}C$, are located near the flange to increase its surface temperature above the dew point. Hot lines are installed in close contact with the flange in order to increase the heat transfer from the hot lines to the flange surface. Through this work, the effects of the hot line shape and installation conditions, including a gap between the hot line and flange, and the function of a spacer in the inner case of the refrigerator were investigated. Additionally, an optimal shape of the inner case for easy assembling is proposed considering the contact between the hot line and flange.

A Study on the Design Parameters of a Gasket and Innercase of a Refrigerator to Reduce Dew Generation on the Outer Surface (표면의 이슬 맺힘 저감을 위한 냉장고 가스켓 및 냉동냉장실 내벽 구조개선에 관한 연구)

  • Kang, Seok-Hoon;Kim, Seong-Jin;Kim, Ju-Hwan;Min, June-Kee;Sohn, Chang-Min;Park, Sang-Hu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.457-463
    • /
    • 2012
  • Current refrigerators are designed to have thin doors and walls to facilitate user convenience and increase inner storage space. However, the thin doors and walls gives rise to the problem of dew generation on the outer surface of a refrigerator due to a large critical temperature difference between the outer wall and the room air; So far, an electric heater is commonly used for making the dew to evaporate; in this case, the heater inevitably requires additional electrical power. We propose a new approach to reduce the dew generation in a refrigerator by redesigning the gasket and varying the thickness of the inner case of the refrigerator. The results of simulations performed in this study indicate that the surface temperature in the region where dew was generated was increased by approximately $0.39{\sim}3.07^{\circ}C$ without the use of a heater.

A Study on the Reduction of Dew Generation on a Surface Using Induced Heat from Room Temperature (외부 열원 전도방식을 이용한 표면 이슬 맺힘 현상의 개선)

  • Kim, Seong-Jin;Kang, Seok-Hoon;Park, Ki-Hong;Yoo, Won-Sul;Park, Sang-Hu;Choi, Ho-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.6
    • /
    • pp.724-731
    • /
    • 2011
  • Dew generation on an outer surface is considered as an important issue to be settled in the field of home appliances. In the case of a refrigerator that is subject to the dew generation problem on the surface of an outer-door of refrigeration thread, and so as to solve this problem, the electric heater is generally used for drying the dew. However, the heater inevitably requires electrical power consumption that is one of critical issues on the refrigerator. In this study, to prevent dew generation without the heater, a method of using induced heat from room temperature was proposed. In edge sides of a door, high conductive plates are installed and received the heat from outside that is relatively high temperature, and the heat is transferred onto dew generation region. Using prototypes, performance test was conducted under a certain temperature and humidity condition. The experimental results show that the surface temperature on the dew generation region was increased about $0.3{\sim}2.5^{\circ}C$ without use of any heater.

A Study on Characteristics of Condensation for RAC Using Flow Visualization Technique (유동 가시화 기법을 이용한 RAC의 이슬 맺힘 특성에 관한 연구)

  • Lee, A-Mi;Kim, Dong-Won;Na, Seon-Uk;Ko, Han-Seo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3092-3097
    • /
    • 2007
  • Although noise of a RAC can be reduced effectively by decreasing RPM, condensation problems can occur to reduce reliability of the RAC for low RPM. Thus, this research has been performed to propose a design guideline of the RAC for low-noise RPM with high reliability. The internal and external flows of the RAC have been visualized and analyzed by a PIV technique to solve the condensation problem at an outlet and impeller. Then, the design guideline has been proposed by the analyzed results and confirmed by wind-tunnel and noise tests to reduce the condensation problem. Finally the shapes of the outlet with reduced condensation problem and the impeller with low noise have been obtained in this study.

  • PDF