3D 초음파 영상에서 방광 내 잔뇨량 추정을 위한 새로운 알고리즘 (A New Algorithm to Estimate Urine Volume from 3D Ultrasound Bladder Images)

  • 조태식;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권1호
    • /
    • pp.31-38
    • /
    • 2016
  • For the patients with bladder dysfunction, measurement of urine volume inside the bladder is very critical to avoid bladder failure. In measuring urine volume inside a bladder, low-resolution 3D ultrasound images are widely used. However, urine volume estimation from 3D ultrasound images is prone to big errors and inconsistency because of low spatial resolution and low signal-to-noise ratio of ultrasound images. We developed a new robust volume estimation algorithm which is not computationally expensive. We tested the algorithm on a lab-built ultrasound bladder phantom and volunteers. The average error rate of the human bladder volume estimation was 5.9% which was better than the commercial machine.

초고층 건물에 적용 가능한 건식벽체의 차음성능 평가 (An Evaluation on the Sound Insulation Performance of Drywall for High-Rise Buildings)

  • 이상우;유호천;이수열;정갑철;정영민
    • KIEAE Journal
    • /
    • 제7권2호
    • /
    • pp.3-8
    • /
    • 2007
  • Recently, the structural system of public residential buildings has been changed from the reinforced concrete (RC) wall system to the (PC) wall and moment resisting systems. Thus, it is important to develop the suitable wall system in accordance with the trend of the modern structural system. This paper presents the basic study on the suitable boundary wall in high-rise buildings. The research also demonstrates the evaluation results on sound characteristics in the aspect of sound insulation. The evaluation of sound insulation capability for the commercialized wall structure was conducted based on literature survey while the measurement of sound insulation capability for the light-weght EPP concrete was performed in according to KS F2808 in laboratory. The main objective of this research is to propose the most suitable dry wall system as a sound insulation structure through the comparison and analysis of frequency characteristics and weight-acoustic attenuation.

소동물 영상시스템의 국내 개발 현황 (Developments of Small Animal Imaging Systems in Korea)

  • 이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권1호
    • /
    • pp.1-9
    • /
    • 2009
  • Many types of small animal imaging modalities, like micro-CT, micro-PET, and micro-SPECT, have been recently developed worldwide. Small animal imaging systems are now recognized as indispensable tools to validate efficacy and safety of new drugs or new therapeutic methods using the animal disease models. With increasing demands for small animal imaging in biomedical research, multimodal small animal imaging systems, like micro-PET/CT or micro PET/MRI, are now also being developed. Small animal imaging with spatial resolution and sensitivity comparable to human imaging is quite challenging since laboratory small animals are much smaller than human beings. Research activities in Korea on small animal imaging systems are reviewed in this paper. In the field of micro-CT and micro-PET, many world-class technologies have been developed successfully in Korea. It is expected that the developed animal imaging system technologies can be used in the development of clinical imaging systems in Korea in the near future.

전기화학적 부식촉진 기법을 이용한 철근 콘크리트 부식의 영향평가 (Application of Electrochemical Accelerated Corrosion Technique to Detection of Reinforcing Corrosion in Concrete)

  • 이수열;이재봉;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.675-678
    • /
    • 1999
  • Rebar corrosion in concrete containing both chloride ions and calcium nitrite inhibitors were investigated by the various electrochemical methods. Rebar corrosion was accelerated by applying the impressed current to the rebar in concrete. Effect of chloride content and inhibitors on rebar corrosion were evaluated. Accelerated corrosion technique is the method to measure the time to the initiation of cracks of reinforced concretes, by applying constant voltage between rebar and the stainless steel cathedes. The increase of concentration of chloride ions in concrete result in the increase in anodic currents and the reduction of time to crack. However addition of inhibitors did not improve corrosion resistance of rebar in concrete. Rebar corrosion in concrete with chloride ions and inhibitors was also analyzed by the immersed tests though the mesurement of corrosion potentials.

  • PDF

스위칭전원을 이용한 자기신경자극기 (The Magnetic Nerve Stimulator Using a Switching Mode Power Supply)

  • 이수열;이성근;이정한
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권3호
    • /
    • pp.265-270
    • /
    • 1995
  • An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for chArging high voltage cApacitors, the weight and size of the magnetic net've stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec Experimental results of human nerve stimulations using the developed stimulator are presented.

  • PDF

전류 주입 자기공명영상에 온도 변화가 미치는 영향 (Effects of Temperature Change on the Current Injected MRI)

  • 이수열;강현수;우응제;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권3호
    • /
    • pp.303-309
    • /
    • 2001
  • It is well known that the electrical impedance of biological tissues is very sensitive to their temperature. In this paper, we have analyzed the effects of temperature change on the phase of magnetic resonance images obtained with external current injection. It has been found that the local phase in the current injected magnetic resonance image can be changed noticeably when local temperature change appears at a part of the tissue. At the experiments with a 0.3 Tesla MRI system, we observed the local phase changes at the phantom images when the phantom temperature was varied between 25 -45$^{\circ}C$. We think that the current injection MRI technique can be used for in-vivo monitoring of the temperature inside biiological tissues if the relation between the local temperature and phase can be quantified.

  • PDF

Fan-Beam CT 영상 재구성 알고리즘 성능 비교 (Performance Comparison of Reconstruction Algorithms for Fan-Beam Computerized Tomography)

  • 이상철;조민형;이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권3호
    • /
    • pp.223-229
    • /
    • 2001
  • In this paper, we have compared the direct fan-beam reconstruction method with the rebinning method in terms of computation time and spatial resolution using computer simulation. As a result, the direct fan-beam method is superior to the rebinning method in the spatial resolution though the former needs longer computation time. However, if we adopt the quarter-detector-offset technique to improve the spatial resolution, the rebinning method outperforms the direct fan-beam method. The computation times have been evaluated using the fast algorithms optimized to reduce the number of interpolation calculations at the back-projection, and the spatial resolutions have been compared using the computer generated phantoms.

  • PDF

입사각에 따른 흡음재의 반사 계수 측정 방법론 및 오차에 대한 고찰 (Measurement of Reflection Coefficient of Sound Absorbent Material with Respect to Angle of Incidence and Its Associated Errors)

  • 이수열;김상렬;김양한
    • 소음진동
    • /
    • 제4권3호
    • /
    • pp.295-305
    • /
    • 1994
  • The reflection coefficient of a material at oblique incidence is measured in a free field. The sound pressure distributions are measured at discrete points on two measurement lines and then decomposed into plane wave components by using spatial Fourier transform. The inciedent and reflected plane wave components are obtained from a set of "decomposition equations" of which uses the plane wave propagation theory. Numerical simulations and experiments have been performed to see the effect of finite size of measurement area. To reduce this effect, a window fuction has been performed to see the effects of finite size of mesurement area. To reduce this effect, a window function has been proposed and its effect on the measurement of sound absorbing material property has been studied as well. The reflection coefficient obtained by this method is compared with those obtained from other methods; 2-microphone method in a duct and an expirical equation of which determines the characteristic impedance .rho.c and propagation constant k of a material from flow resistance information.formation.

  • PDF

3.0 T MRI 환경에서 마이크로비드를 이용한 서브복셀 추적에 관한 수치해석적 연구 (Numerical Study on the Sub-Voxel Tracking Using Micro-Beads in a 3.0 T MRI)

  • 한병희;이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.102-107
    • /
    • 2007
  • In molecular imaging studies via magnetic resonance imaging, in vivo cell tracking is an important issue for the observation of cell therapy or disease behavior. High resolution imaging and longitudinal study are necessary to track the cell movement. Since the field inhomogeneity extends over several voxels, we have performed the numerical analysis using the sub-voxel method dividing a voxel of MR image into several elements and the information about the field inhomogeneity distribution around the micro-beads. We imbedded ferrite-composite micro-beads with the size of $20-150{\mu}m$ in the subject substituted for cells to induce local field distortion. In the phantom imaging with the isotropic voxel size of $200{\mu}m^3$, we could confirm the feasibility of sub-voxel tracking in a 3.0 T MRI.

적외선 체열촬영시스템을 위한 광학계의 구성 (Realization of Optic Systems for the Infrared Thermography)

  • 이수열;우응제;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권1호
    • /
    • pp.97-104
    • /
    • 1994
  • In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensionaloptic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the infrared thermography system composed ofthe proposed optic system has the temperature resolution of $0.1{\circ}C$ under the spatial resolution of 1mrad, the image matrix size of $256{\times}240$, and the imaging time of 4 seconds.

  • PDF