• Title/Summary/Keyword: 이상 반응조

Search Result 444, Processing Time 0.021 seconds

Two-Phase Jet Flow Characteristics in the Pure Oxygen Aeration System Using Two-phase Jet Nozzle (이상 제트 노즐을 사용한 순산소 폭기시스템의 이상유동 특성)

  • Jung, Chan-Hee;Lee, Kye-Bock
    • Journal of Energy Engineering
    • /
    • v.18 no.4
    • /
    • pp.258-263
    • /
    • 2009
  • Jet Loop Reactor(JLR), in which a two-phase nozzle is installed, is the new design technique for the treatment of high concentration wastewater by accelerating of oxygen contacting between substrate and surrounding bacteria. This numerical study of the two phase jet flow was conducted to find the optimum design of JLR. It was shown that there was a minimum velocity in the nozzle for continuous circulation of wastewater. The optimum location and the size of the draft tube for continuous circulation were examined. It was certain that the smaller the air size is, the more the effect of the mixing increases. The relation between the mixing effect and the turbulence was confirmed.

Effects of the Recirculation Port Location on Treatment Efficiency of an Anaerobic Hybrid Reactor Consisted of a Fluidized Bed and a Packed Bed (유동상과 충전상이 결합된 혐기성 혼성 반응조에서 순환수의 인출지점이 처리효율에 미치는 영향)

  • Kim, Seong-Yong;Park, Soo-Young;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.1935-1944
    • /
    • 2000
  • This research was performed to investigate the effects of the location of recirculation port on the wastewater treatment efficiency of an anaerobic hybrid reactor consisted of a fluidized bed and a packed bed. The recirculation port was located either at the top of the packed bed (Reactor 2) or above the fluidized bed (Reactor 1). Media for the fluidized bed and the packed bed were granular activated carbon and Pall ring-type plastic media. respectively. At organic loading rates(OLR) up to $6.2kg\;COD/m^3-day$. Reactor 2 showed somewhat better performance than Reactor 1 with COD removal efficiencies of 85.0-95.2%. The COD removal efficiencies of the reactors drastically deteriorated at OLRs above $6.2kg\;COD/m^3-day$, and the tendency was more severe for Reactor 1 than for Reactor 2. Eventhough the two reactors showed similar effluent SS concentrations at OLRs below $3.6kg\;COD/m^3-day$, Reactor 2 showed higher effluent SS concentrations than Reactor 1 at OLRs above $5.3kg\;COD/m^3-day$. Reactor 2 was stabler than Reactor 1 with a methane production rate of $5.5kg\;COD/m^3$-day at the OLR of $13.3kg\;COD/m^3-day$. An abrupt increase in effluent volatile acid concentration was observed at the OLR of $6.2kg\;COD/m^3-day$ for Reactor 1 and $7.1kg\;COD/m^3-day$ for Reactor 2. and the increase was greater in Reactor 1. In conclusion. the range of OLR for adequate treatment in the hybrid reactor was determined according to the location of the internal recirculation port. It is more desirable for higher OLRs to locate the recirculation port at the top of the packed bed in order to utilize the whole volume of the reactor.

  • PDF

Dehydration Reaction of Phosphogypsum in a Fluidized Bed Reactor (유동화 반응조에서의 인산석고의 탈수반응에 관한 연구)

  • Il Hyun Park;Shin Hwan Ihn;Youn Soo Sohn
    • Journal of the Korean Chemical Society
    • /
    • v.24 no.4
    • /
    • pp.329-336
    • /
    • 1980
  • A domestic phosphogypsum was calcined in a batch type fluidized bed reactor at various reaction temperatures ranging 90∼180$^{\circ}$ without and with an alkaline additive amounting up to 5% of gypsum, and physical properties of the resultant products were compared following their characterization by X-ray diffraction pattern and DTA. It has been found that dehydration reactions were uniformly carried out in the fluidized bed reactor and only hemihydrate was obtained at 90$^{\circ}$ whereas at higher temperatures dehydration reaction progressed further. When gypsum was charged to the reactor preheated at over 140$^{\circ}$, a considerable degree of dehydration occurred before the reactant reached the initially set reactor temperature and in particular, at over 160$^{\circ}$ most of dehydration reaction was performed prior to the present reactor temperature. However, it has been found that gypsum mostly transforms into hemihydrate around the reactant temperature of 140$^{\circ}$ while transformation into anhydrite mostly occurs around $160^{\circ}C.$ When calcium hydroxide was added to gypsum in the reactor, the optimum physical properties of the calcined product were obtained at the weight ratio of $Ca(OH_2)/P_2O_5$ = 3.2.

  • PDF

Effect of the Addition of Granular Activated Carbon and Granular Sludge on the Performance of Upflow Anaerobic Sludge Blanket Reactors for Treating Leachate (상향류 혐기성 슬러지 블랭킷 반응조를 이용한 침출수 처리시 입상 활성탄 및 입상슬러지 첨가의 영향)

  • Lee, Chae-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.4
    • /
    • pp.91-97
    • /
    • 2008
  • The objective of this research is to investigate the effect of the addition of granular activated carbon (GAC) and granular sludge on the performance of upflow anaerobic sludge blanket (UASB) reactors for treating leachate. For the control reactor, sludge obtained from an anaerobic digester was used as a seed material. On the other hand, GAC and granular sludge were incorporated with the seed sludge in the GAC reactor and the Granule reactor, respectively. The shortest acclimation period was observed in the Granule reactor. The GAC reactor also gave comparable performance to the Granule reactor at the beginning of operation. However, as the adsorptive capacity of GAC was exhausted, the effluent COD concentration increased gradually. Once the systems were stabilized, the GAC reactor showed slightly better results than the other two reactors in terms of chemical oxygen demand (COD) removal. COD removal in all reactors was more than 90% at hydraulic retention time of 1.0 day. Furthermore, GAC reactor showed little variation in COD removal rate and remained at 95% with organic loading rate (OLR) of 4.0 to $8.2kg\;COD/m^3.d$. Initial operating period was reduced by the addition of granular sludge, while the treatment efficiency was enhanced by the addition of GAC.

  • PDF

Treatment of Seafood Wastewater using an Improved High-rate Anaerobic Reactor (개선된 고율혐기성 공정을 이용한 수산물 가공폐수처리)

  • Choi, Byeong-Yeong;Choi, Yong-Bum;Han, Dong-Jun;Kwon, Jae-Hyeok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7443-7450
    • /
    • 2014
  • To resolve shortcomings of high-rate anaerobic processes, such as high upward flow velocity, this study sought to improve the structure of the high-rate anaerobic reactor and evaluate its performance. The improved reactor was manufactured by adjusting the diameter and dividing the reactor into three parts. The evaluation of the structurally improved reactor revealed that the reactor could stabilize a single circuit, and prevent the accumulation of solid matter and leakage of microbes, thereby stabilize the microbes. In the process of anaerobic digestion, an increase in pH and alkalinity within the reactor was presumably attributed to bicarbonate created in the process of organic matter decomposition and due to the re-dissolution of some biogas. To maintain a high rate of organic matter removal, the reactor should be operated with more than 9 hrs of HRT and an organic matter load of under $10.kgTCODcr/m^3{\cdot}d$. The methane gas generated in the anaerobic digestion process showed a high content of 65~83 % at the organic matter load of over $7.7kgTCODcr/m^3{\cdot}d$. per removal of CODcr. The methane quantity was generated at $0.10{\sim}0.23m^3CH_4/kgCOD_{rem}$, showing that it was smaller than the theoretical methane generation amount (0.35) in the STP state. In the latter part of high-rate anaerobic process, an advanced treatment process was required to remove nitrogen.

Effects of Ammonia Loading on Nitrification and Nitrite Build-up in an Activated Carbon Fluidized Bed Biofilm Reactor (암모니아 부하가 활성탄 유동상에서의 질산화 및 아질산 축적에 미치는 영향)

  • Choi, In-Cheol;Park, Soo-Young;Lee, Kwan-Yong;Bae, Jae-Ho;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.53-60
    • /
    • 2000
  • The effects of ammonia loading on nitrification, especially on nitrite build-up, in an activated carbon fluidized bed reactor were investigated by increasing the ammonia loading rate stepwise from 0.1 to $7.5kg\;NH_3-N/m^3{\cdot}day$. Although effluent nitrite concentration and nitrification efficiency fluctuated at the loading rates above $1.8kg\;NH_3-N/m^3{\cdot}day$, an average nitrification efficiency of 90% was achieved. Nitrite build-up began at an ammonia loading rate of $l.8kg\;NH_3-N/m^3{\cdot}day$, at which the free ammonia concentration was estimated to be above 1 mg/L. During the nitrite build-up, the ratio of influent $NH_3-N$ concentration to the DO concentration of the reactor liquor and the ratio of effluent $NH_3-N$ concentration to the DO concentration of the reactor liquor was measured to be above 100 and 2, respectively. Considering the advantages of nitritation/denitrification, a fluidized bed reactor could be an effective means for biological nitrification of wastewaters with high ammonia concentration.

  • PDF

Fouling Characteristics in Submerged Membrane System of Two-Phase Anaerobic Reactor for Piggery Wastewater Treatment (축산폐수 처리를 위한 막결합형 이상 혐기성 반응조에서 여과막 저항특성)

  • Lee, Sang-Min;Jung, Jin-Young;Chung, Yun-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.3
    • /
    • pp.523-533
    • /
    • 2000
  • A two-phase anaerobic reactor with submerged membrane system was developed for increasing acidogen concentration and methane recovery. The membrane used was mixed esters of cellulose of $0.5{\mu}m$ pore size and $0.8m^2$ of effective surface area. The methanogenic reactor comprised of UASB (Upflow Anaerobic Sludge Blanket) and AF (Anaerobic Filter). COD removal efficiency was 70~80% and the methane content in the biogas increased up to 90% for the submerged membrane system in the anaerobic reactor. As the cake resistance of membrane caused a serious problem, stainless steal prefilters (40, 53, $63{\mu}m$) and air backwashing methods were applied to minimize the cake resistance effectively. Among the tested prefilters. the $63{\mu}m$ prefilter showed the best performance for reduction of cake resistance and a successful long-tern operation. By cleaning with alkali first and acidic solution later. the permeate flux decreased by long term operation was recovered to 89% of that with a new membrane.

  • PDF

Simultaneous Denitrification and Methanogenesis at Various ${NO_3}^--N/COD$ Ratios in an USB Reactor (USB 반응조에서 ${NO_3}^--N/COD$ 비해 따른 탈질과 메탄화 동시반응)

  • Park, Sang-Min;Jun, Hang-Bae;Park, Noh-Back;Oh, Gyu-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1174-1179
    • /
    • 2005
  • Up-flow sludge blanket(USB) reactors were used to investigate the effects of N/C(${NO_3}^--N/COD$) ratio on simultaneous denitrification and methanogenesis processes. Without nitrate feeding, 84% of the influent COD was converted into methane. With the increase of N/C ratio, nitrogen gas increased while methane production decreased and stopped finally at the N/C ratio over 0.20. Influent nitrate was completely denitrified into nitrogen gas while nitrate removal efficiency dropped below 40% at N/C ratio of 0.40 because of deficiency in organic carbon. Fraction of COD utilized by denitrification increased at higher N/C ratios. Methanogenesis started to be effected at N/C ratio of 0.05, which could explain the competition for organic carbon between these microorganisms such as denitrifiers and methanogens, rather than inhibitory effect of nitrate and its intermediates. Critical N/C ratio for simultaneous denitrification and methanogenesis was found to be 0.20. Influent COD was removed over 92% by denitrification, methanogenesis and other biochemical reactions including cell growth at these N/C ratios.

Anaerobic Digestion of Distillery Wastewater in a Two-phase UASB System (이상 UASB 공정을 이용한 주정폐수의 혐기성소화)

  • Shin, Hang Sik;Bae, Byung Uk;Paik, Byung Cheon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.4
    • /
    • pp.185-192
    • /
    • 1990
  • A two-phase UASB system was operated for high-rate treatment of concentrated distillery wastewater. The phase separation was obtained by adjusting pH in each reactor. When influent SS concentration was 4.1/g/l, the first phase UASB reactor was effectively operated up to the loading rate of 16.5kg $COD/m^3.day$, producing 3.9g HAc/l.day. In the methanogenic UASB reactor, loading rate up to 44kg $COD/m^3.day$ could be applied while removing 80% of influent COD with a specific gas production of 16.5 l/l. day. After the formation granular sludge in both reactors, it was possible to maintain the appropriate pH in the first phase only by recirculating the effluent from methanogenic phase without the addition of alkaline chemicals.

  • PDF

High-rate Anaerobic Treatment of Landfill Leachate (매립지 침출수 처리의 고율 혐기성 처리)

  • Lee, Chae-Young;Shin, Hang-Sik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.2
    • /
    • pp.136-146
    • /
    • 2007
  • Landfill leachate was successfully treated in upflow anaerobic sludge blanket (UASB) reactors regardless of the addition of granular sludge. Initial operating period was significantly reduced by the addition of granular sludge. At hydraulic retention time (HRT) of one day, chemical oxygen demand (COD) removal rates in Control and Granule reactor were maintained over 90%, respectively with organic loading rate (OLR) of $4-8kgCOD/m^3.d$. During the experiment, the inorganic precipitates were accumulated in and around the sludge, and in the wall of the reactors were formed in both reactors regardless of addition of granular sludge. Specific methanogenic activity (SMA) increased as adaptation of microorganism to the substrate and OLR were increased. The maximum SMA value of the sludge for Granule reactor was about $0.57gCOD/g{\cdot}VSS{\cdot}.d$. The SMA value was not decreased because of excessive inorganic accumulation, however, it was needed to have pre-treatment process of influent to remove the inorganic metals.

  • PDF