• Title/Summary/Keyword: 이상 노즐

Search Result 258, Processing Time 0.027 seconds

Conceptual Design of a LOX/Methane Rocket Engine for a Small Launcher Upper Stage (소형발사체 상단용 액체메탄 로켓엔진의 개념설계)

  • Kim, Cheulwoong;Lim, Byoungjik;Lee, Junseong;Seo, Daeban;Lim, Seokhee;Lee, Keum-Oh;Lee, Keejoo;Park, Jaesung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.4
    • /
    • pp.54-63
    • /
    • 2022
  • A 3-tonf class liquid rocket engine that powers the upper stage of a small launcher and lifts 500 kg payload to 500 km SSO is designed. The small launcher is to utilize the flight-proven technology of the 75-tonf class engine for the first stage. A combination of liquid oxygen and liquid methane has been selected as their cryogenic states can provide an extra boost in specific impulse as well as enable a weight saving via the common dome arrangement. An expander cycle is chosen among others as the low-pressure operation makes it robust and reliable while a specific impulse of over 360 seconds is achievable with the nozzle extension ratio of 120. Key components such as combustion chamber and turbopump are designed for additive manufacturing to a target cost. The engine system provides an evaporated methane for the autogenous pressurization system and the reaction control of the stage. This upper stage propulsion system can be extended to various missions including deep space exploration.

Development of Mobile Vortex Wet Scrubber and Evaluation of Gas Removal Efficiency (기체상 유해화학물질 제거를 위한 이동형 와류식 세정장치 개발 및 가스 제거효율 분석)

  • Kwak, Ji Hyun;Hwang, Seung-Ryul;Lee, Yeon-Hee;Kim, Jae-Young;Song, Ki Bong;Kim, Kyun;Kang, Jae Eun;Lee, Sang Jae;Jeon, Junho;Lee, Jin Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.2
    • /
    • pp.134-138
    • /
    • 2015
  • BACKGROUND: In recent years, several researchers have focused on odour control methods to remove the harmful chemicals from chemical accidents and incidents. The present work deals with the system development of the hazardous. METHODS AND RESULTS: For on-site removal of hazardous gaseous materials from chemical accidents, mobile vortex wet scrubber was designed with water vortex process to absorb the gas into the water. The efficiency of the mobile vortex wet scrubber was evaluated using water spray and 25% ammonia solution. The inlet air velocity (gas flow rate) was according to the damper angle installed within the hood and with increase of gas flow rate, consequently the absorption efficiency was markedly decreased. In particular, when 25% ammonia solution was exposed to the hood inlet for 30 min, the water pH within the scrubber was changed from 7 to 12. Interestingly, although the removal efficiency of ammonia gas exhibited approximately 80% for 5 min, its efficiency in 10 min showed the greatest decrease with 18%. Therefore, our results suggest that the ammonia gas may be absorbed with the driving force of scrubbing water in water vortex process of this scrubber. CONCLUSION: When chemical accidents are occurred, the designed compact scrubber may be utilized as effective tool regarding removal of ammonia gas and other volatile organic compounds in the scene of an accident.

Eco-friendly Control of Whiteflies by Two-Fluid Fogging System with Natural Substances in Greenhouses (이류체 포그시스템 및 천연물을 이용한 친환경적 가루이 방제)

  • Kim, Sung-Eun;Lee, Sang-Don;Lee, Moon-Haeng;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.114-119
    • /
    • 2012
  • We have conducted 4 experiments to develop the most environmental and effective use of the two-fluid fog system to prevent and exterminate whiteflies in tomato cultivation. In particular, these experiments used Vitamini tomatoes grown in stand-alone greenhouses at Buyeo Tomato Experiment Station as subjects. Each experiment utilized the fog system in a different way. The first experiment provided the control group, which was subject to the two-fluid fog system without additional humidity control. In the second experiment, the two-fluid fog system controlled the humidity level to be above 70%. The third and the fourth experiment utilized natural substances, which were 1.5 mg/L of Neem Oil and 2 mg/L of Oleic acid respectively, without additional humidity control. From the first experiment, we could observe that a simple use of the two-fluid fog system decreased the density of whiteflies in the greenhouses. This impact of the fog system on whiteflies was greater in the second experiment. By comparing the first and the second experiment, we concluded that whiteflies are more effectively prevented by maintaining a higher humidity level via the fog system's smaller water droplets that float in the air for longer time than the standard fog system in rather dry condition. In the third and the fourth experiments, the extermination level was 78% and 76.4% respectively, comparing only 53% in the first experiment without the humidity control. Therefore, using the natural substances in addition to the humidity control increases the extermination effectiveness. Considering the similar results from the 3rd and the 4th experiments, Oleic acid has a greater appeal for its lower price. Using the two-fluid fog system to both control the humidity on a daily basis and spray the substances for occasional extermination would reduce labor cost and increase production in an environmental way.

On decrease program of Radioactive Wastewater and Sewages in High Dose Radioiodine Therapy Ward (고용량 방사성옥소 치료병실의 오.폐수 저감화를 위한 연구)

  • Ryu, Jae-Kwang;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.19-26
    • /
    • 2008
  • Purpose: In general, We discharged radioactive wastewater and sewages less than $8.1{\times}10^{-13}$ Ci/ml in a exclusive water-purifier tank. Our hospital operating three exclusive water-purifier tank for radioactive wastewater and sewages of 60 tons capacity respectively. In order to meet the criteria it need a enough decay more than 125 days per each exclusive tank. However, recently we fell into the serious situation that decay period was decreased remarkably, owing to the wastewater amount increased rapidly by enlarge the therapy ward. For that reason, in this article, I'd like to say the way that reducing of radioactive wastewater and sewages rationally. Materials and Methods: From January, 2006 to October, four hundred and two cases were analyzed. They were all hospitalized during 3 days and 2 nights. We calculated the average amount of water used (include toilet water used, shower water used, washstand water used, $\cdots$), each exclusive water-purifier tank's decay period, as well as try to search the increased factors about water-purifier tank inflow flux by re-analysis of the procedure of radioisotope therapy step by step. Results: We could increase each exclusive water-purifier tank's decay period from 84 days to 130 days through the improvement about following cause: (1) Improvement of conventional toilet stool for excessive water waste $\rightarrow$ Replacement of water saving style toilet stool (2) Prevention of unnecessary shower and wash (3) Stop the diuretics taking during hospitalization (4) Analysis of relationship between water intakes and residual dose of body (5) Education about outside toilet utilization before the administration (6) Changed each water-purifier tank's maximum level from85% to 90% Conclusion: The originality of our efforts are not only software but hardware performance improvements. Incidentally the side of software's are change of therapy procedures and protocols, the side of hardware's are replacement of water saving style toilet stool and change of each water-purifier tank's maximum level. Thus even if a long lapse of time, problem such as return to the former conditions may not happen. Besides, We expect that our trials become a new reasonable model in similar situation.

  • PDF

Development of Precision Overhead Watering and Boom Irrigation System for Fruit Vegetable Seedlings (과채류 육묘용 정밀 두상관수 시스템 개발)

  • Dong Hyeon Kang;Soon Joong Hong;Dong Eok Kim;Min Jung Park
    • Journal of Bio-Environment Control
    • /
    • v.32 no.1
    • /
    • pp.8-14
    • /
    • 2023
  • This study was conducted to develop a precision automatic irrigation system in a nursery by considering the problems and improvements of manual and the conventional automatic irrigation system. The amount of irrigated water between the conventional automatic irrigation system and manual irrigation was 28.7 ± 4.4 g and 14.2 ± 4.3 g, respectively, and the coefficient of variation was less than 30%. However, the coefficient of variation of the conventional automatic irrigation system of 15%, was higher than that of manual irrigation of 30%. The irrigation test using the developed uniform irrigation system attached with the nozzle of a spray angle 80° and most highest uniformity was at height 600 mm. And coefficient of variation of the irrigation uniformity at the center part was within 20%, but irrigation amount of the edge part was lower 50% and over compared to the center part. As a result of a tomato grafting seedling cultivation test using the developed uniform irrigation system, the average plant height of seedling at the edge part was 28 mm but plant height at the center part was higher as 72 mm. Therefore, it was necessary to apply additional irrigation device at the edge part. The irrigation uniformity of the edge concentrated irrigation system was investigated that the irrigation amount of the edge part was irrigated by more than 50% compared with the center part, and coefficient of variation of the irrigation amount at the center part was less than 30%. As a result of a cucumber grafting seedling cultivation test using the edge concentrated irrigation system, the plant height of seedlings in the edge and central part of cultivation bed were 24% and 26%, respectively, so irrigation uniformity was higher then the uniform irrigation system. In order to improve the uniformity of seedlings, it is necessary to adjust the height of boom according to the growth of the seedling by installing a distance sensor in the overhead watering and boom irrigation system.

Properties of Organic-Inorganic Protective Films on Flexible Plastic Substrates by Spray Coating Method (연성 플라스틱 기판위에 스프레이 코팅방법으로 제조한 유·무기 보호막의 특성)

  • Lee, Sang Hee;Chang, Ho Jung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.79-84
    • /
    • 2017
  • The solar cells should be protected from the moisture and oxygen in order to sustain the properties and reliability of the devices. In this research, we prepared the protection films on the flexible plastic substrates by spray coating method using organic-inorganic hybrid solutions. The protection characteristics were studied depending on the various process conditions (nozzle distance, thicknesses of the coatings, film structures). The organic-inorganic solutions for the protection film layer were synthesized by addition of $Al_2O_3$ ($P.S+Al_2O_3$) and $SiO_2$ ($P.S+SiO_2$) nano-powders into PVA (polyvinyl alcohol) and SA (sodium alginate) (P.S) organic solution. The optical transmittances of the protection film with the thicknesses of $5{\mu}m$ showed 91%. The optical transmittance decreased from 81.6% to 73.6% with the film thickness increased from $78{\mu}m$ to $178{\mu}m$. In addition, the protective films were prepared on the PEN (polyethylene naphthalate), PC (polycarbonate) single plastic substrates as well as the Acrylate film coated on PC substrate (Acrylate film/PC double layer), and $Al_2O_3$ film coated on PEN substrate ($Al_2O_3$ film/PEN double layer) using the $P.S+Al_2O_3$ organic-inorganic hybrid solutions. The optimum protection film structure was studied by means of the measurements of water vapor transmittance rate (WVTR) and surface morphology. The protective film on PEN/$Al_2O_3$ double layer substrate showed the best water protective property, indicating the WVTR value of $0.004gm/m^2-day$.

Application of Dissolved Air Flotation Technique to Improve Eutrophic Reservoir Water Quality (가압부상법을 이용한 부영양저수지의 수질개선)

  • Kim, Ho-Sub;Jung, Dong-Il;Lee, Il-Kuk;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.372-381
    • /
    • 2005
  • This study was conducted to test the efficiency of water quality improvement using the dissolved air flotation (DAF) technique in a shallow eutrophic reservoir. The application of DAF was followed by the addition of a chemical coagulant (poly aluminum chloride; PAC). The experiment was conducted in the mesocosm scale (wide ${\times}$ length ${\times}$ depth: 6 m ${\times}$ 6 m ${\times}$ 3 m). Suspended solids (SS) and volatile SS (VSS) concentration decreased by 54 ${\sim}$ 71% and 57 ${\sim}$ 79% of the initial concentrations, respectively. Total phosphorus and Chl- a concentration also decreased by 74 ${\sim}$ 92% and 54 ${\sim}$ 98%, respectively. BOD decreased by>86% while COD decrease ranged 29 ${\sim}$ 63%. Dissolved inorganic P (DIP) and dissolved total P (DTP) concentration decreased by 34 ${\sim}$ 88% and 62 ${\sim}$ 88%, respectively. After DAF application further onto the sediment, DIP-release rates from the sediment decreased by 17% (0.82 ${\to}$ 0.68 mg $m^{-2}$$day^{-1}$ in the oxic condition and 23% (2.27 ${\to}$ 1.76 mg $m^{-2}$$day^{-1}$) in the anoxic condition, compared to the release rate from the untreated sediment. DTP-release rate from both the oxic and anoxic sediments also decreased by 33% (5.62 ${\to}$ 3.78 mg $m^{-2}$$day^{-1}$) and 20% (6.23 ${\to}$ 4.99 mg $m^{-2}$$day^{-1}$), respectively. These results suggest that the DAF application both to the water column and onto the sediment be effective to improve water quality by removing particulate matters in the water column as well as reducing P-release from the sediment.

Development of Control Algorithm for Greenhouse Cooling Using Two-fluid Fogging System (이류체 포그 냉방시스템의 제어알고리즘 개발)

  • Nam, Sang-Woon;Kim, Young-Shik;Sung, In-Mo
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.138-145
    • /
    • 2013
  • In order to develop the efficient control algorithm of the two-fluid fogging system, cooling experiments for the many different types of fogging cycles were conducted in tomato greenhouses. It showed that the cooling effect was 1.2 to $4.0^{\circ}C$ and the cooling efficiency was 8.2 to 32.9% on average. The cooling efficiency with fogging interval was highest in the case of the fogging cycle of 90 seconds. The cooling efficiency showed a tendency to increase as the fogging time increased and the stopping time decreased. As the spray rate of fog in the two-fluid fogging system increased, there was a tendency for the cooling efficiency to improve. However, as the inside air approaches its saturation level, even though the spray rate of fog increases, it does not lead to further evaporation. Thus, it can be inferred that increasing the spray rate of fog before the inside air reaches the saturation level could make higher the cooling efficiency. As cooling efficiency increases, the saturation deficit of inside air decreased and the difference between absolute humidity of inside and outside air increased. The more fog evaporated, the difference between absolute humidity of inside and outside air tended to increase and as the result, the discharge of vapor due to ventilation occurs more easily, which again lead to an increase in the evaporation rate and ultimately increase in the cooling efficiency. Regression analysis result on the saturation deficit of inside air showed that the fogging time needed to change of saturation deficit of $10g{\cdot}kg^{-1}$ was 120 seconds and stopping time was 60 seconds. But in order to decrease the amplitude of temperature and to increase the cooling efficiency, the fluctuation range of saturation deficit was set to $5g{\cdot}kg^{-1}$ and we decided that the fogging-stopping time of 60-30 seconds was more appropriate. Control types of two-fluid fogging systems were classified as computer control or simple control, and their control algorithms were derived. We recommend that if the two-fluid fogging system is controlled by manipulating only the set point of temperature, humidity, and on-off time, it would be best to set up the on-off time at 60-30 seconds in time control, the lower limit of air temperature at 30 to $32^{\circ}C$ and the upper limit of relative humidity at 85 to 90%.