• 제목/요약/키워드: 이상 감지 시스템

Search Result 427, Processing Time 0.038 seconds

Evaluation of Ventilation Systems in an Enclosed Nursery Pig House (무창자돈사의 환기시스템 정립 및 환기효율 평가)

  • Song, J.I.;Choi, H.L.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.123-134
    • /
    • 2002
  • An experiment was conducted to establish the most suitable ventilation system for the enclosed nursery pig house in Korea, comparing four different ventilation systems ; i) air enters through perforated ceiling and exhausts through chimney (NA), ii) air enters through perforated ceiling and exhausts through side walls (NB), iii) air enters through perforated ducts and exhausts through side walls (NC) and iv) air enters through perforated ducts and exhausts through chimney(ND). The experiment was carried out during winter and summer separately. The experimental pigs were weaned at fourteen days old in winter (December-February) and at twenty one days old in summer (June-August). The main results of the experiment are as follows : A preliminary experiment showed that in the NC system during summer, air can reach all the pig rooms in the house and the air flow rates of the upper, middle (1.2 m height of the room) and low (at the height of pig stature) parts of the room were measured at 7.0-8.08, over 0.5 and over 0.2 m/s, respectively, which flow rates were much higher(p$<$0.05) than those in other system. At the minimum ventilation efficiency during winter, air flow rates of upper, middle and low parts of the room equipped with the NC system were detected at over 1, less than 0.5 and around 0.07 m/s, respectively. It is concluded that the separated ventilation system air-entering through ducts is the most suitable for the ventilation system of the enclosed nursery pig house and the exhausting system through side walls is more efficient for ventilation than the system through roof. Furthermore, to sustain proper temperature and reduce energy waste as well as heat consumption, a future research should be carried out to develop the environmental control system in relation to developing a heat regulator.

Presentation control of the computer using the motion identification rules (모션 식별 룰을 이용한 컴퓨터의 프레젠테이션 제어)

  • Lee, Sang-yong;Lee, Kyu-won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.586-589
    • /
    • 2015
  • A computer presentation system by using hand-motion identification rules is proposed. To identify hand motions of a presenter, a face region is extracted first using haar classifier. A motion status(patterns) and position of hands is discriminated using the center of gravities of user's face and hand after segmenting the hand area on the YCbCr color model. User's hand is applied to the motion detection rules and then presentation control command is then executed. The proposed system utilizes the motion identification rules without the use of additional equipment and it is then capable of controlling the presentation and does not depend on the complexity of the background. The proposed algorithm confirmed the stable control operation via the presentation of the experiment in the dark illumination range of indoor atmosphere (lx) 15-20-30.

  • PDF

진공패키지에 의해 조립된 볼로미터 적외선 센서의 특성

  • Han, Myeong-Su;Kim, Jin-Hyeok;Sin, Gwang-Su;Kim, Hyo-Jin;Kim, Seon-Hun;Go, Hang-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.241-241
    • /
    • 2010
  • 적외선 센서는 빛의 유무에 관계없이 물체 또는 인체에서 발산하는 적외선을 감지한다. 이러한 센서를 전자 및 디스플레이 시스템과 연동하면 열영상 시스템이 되는데, 이는 전방 감시, 플랜트 감시, 보안, 방범용으로 많이 사용되며, 특히 자동차 야간 운전자 보조용으로 사용되어 최첨단, 고부가가치를 지니고 있는 핵심부품이다. 비냉각형 적외선 센서인 마이크로볼로미터는 상온에서 작동하므로 극저온 Cooler가 불필요하며, 무게와 부피가 작아 각종 시스템에 부착가능하다. 특히 볼로미터형 적외선 센서는 용량이 적은 TE cooler로 상온으로 안정화를 시키며, 진공으로 유지되는 금속 또는 세라믹 패키지를 사용하게 된다. 본 연구에서는 마이크로 볼로미터용 진공패키지를 제작하여 패키지 조립 및 측정기술에 대해 조사하였다. 패키지는 금속재질인 kovar를 사용하여 제작되었고, 내부에 TE Cooler와 장수명 진공유지를 위한 getter, 그리고 온도센서 및 볼로미터 센서 칩을 장착하여 조립하였다. 패키지 Cap ass'y와 base envelop의 솔더링 공정은 약 $200^{\circ}C$에서 수행하였으며, evacuation system을 이용하여 5일 동안 패키지 bake-out 공정을 수행하였다. 이 후 getter를 활성화시키고, seal-off 공정으로 진공 기밀을 유지하였다. 진공 패키지의 기밀성은 $6{\times}10^{-9}\;std.cm^3/sec$로 기밀성을 유지하였다. 볼로미터 센서의 반응도는 $10^2\;V/W$ 이상을 나타내었으며, 탐지도는 $2{\times}10^8\;cm-Hz^{1/2}/W$를 나타내었다.

  • PDF

Development of Ubiquitous-based Monitoring Service System (유비쿼터스 기반의 모니터링 서비스 시스템의 개발)

  • Noe, Chan-Sook;Kim, Ki-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3170-3175
    • /
    • 2009
  • In this paper, we developed u-Care service system using technologies of USN and LBS to help construct social welfare infrastructure and social safety net for lone seniors and handicapped people. This service not only monitors the in-house and outdoor activities of those disabled people but also sends the messages, whenever abnormal behaviors are detected, to the people related to them as well as the social welfare organizations and public safety institutions such as police and emergency services and etc in order to alert them.

Implementation of Optimal Flicker Free Display Controller for LED Display System (LED 디스플레이 시스템을 위한 최적의 플리커 프리 디스플레이 제어장치 구현)

  • Lee, Juyeon;Kim, Daesoon;Lee, Jongha
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.6
    • /
    • pp.123-133
    • /
    • 2017
  • In this paper, we developed an optimal flicker-free control algorithm operating within 16 luminance implementation bits and 512 brightness implementation pulses irrespective of LPM(LED Pixel Matrix) module configuration on dynamic driving method of LED display system. As an implementation method, we turned the refresh rate up by increasing the number of scans through multiple shift-latches which were devised from conventional shift-latch scheme for full color representation. As a result, the LED display system of this method has no flicker phenomenon because of the novel refresh rate higher than 2,040[Hz] incomparable to 240~480[Hz] of conventional system.

Design of Modular DC / DC Converter with Phase-Shifting Topology (위상천이 방식의 모듈형 DC/DC 컨버터 설계)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • This paper is concerned with a system design that enables a the plurality of switching mode power supplies to be supplied with larger power through a parallel connection. For this purpose, a shunt resistor is placed in series at the output of the constant voltage regulator and the output voltage is sensed and controlled using an arduino. In this paper, two constant-voltage regulators were used for the experiment, but it is possible to generalize for more boards. By using the method that controls the system, the sum of the currents delivered by the two systems to the load was found to be 96% of the current drawn from each board. In case of efficiency, 92.4% efficiency is achieved in the unit board and the efficiency in parallel connection is about 90%.

Bio-Monitoring System Using Shell Valve Movements of Pacific Oyster (Crassostrea gigas) -I. Detecting Abnormal Shell Valve Movements Under Low Salinity Using a Hall Element Sensor (굴(Crassostrea gigas)의 패각운동을 이용한 생물모니터링시스템 연구 -I. 홀 소자를 이용한 저염분하에서 비정상적인 패각운동 측정)

  • Oh, Seok Jin;Lee, Jun-Ho;Kim, Seok-Yun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.2
    • /
    • pp.138-142
    • /
    • 2013
  • As an early warning system to reduce the damage of aquacultured mollusks due to low salinity water, we investigated the possibility of a biomonitoring system measuring the shell valve movement (SVM) of Pacific oyster (Crassostrea gigas) by using the Hall element sensor. In high salinity water of 27 psu, SVMs of Pacific oyster showed spikes which mean a relatively fast closing condition after opened condition of average 10-15 mm, and then the SVM showed back to opening condition slower than closing speed. In water salinity of 20-27 psu, the SVMs were similar to that of 27 psu. However, below 17 psu, it showed abnormal valve movements such as spending more time for shell closure. In 10 psu, we could not detected SVMs due to closed condition during experiment periods. Thus, if we quickly detect abnormal environmental variations like low salinity using bio-monitoring of SVM, it may be contribute to increased productivity by dramatically reducing damages in aquaculture.

Self-driving quarantine robot with chlorine dioxide system (이산화염소 시스템을 적용한 자율주행 방역 로봇)

  • Bang, Gul-Won
    • Journal of Digital Convergence
    • /
    • v.19 no.12
    • /
    • pp.145-150
    • /
    • 2021
  • In order to continuously perform quarantine in public places, it is not easy to secure manpower, but using self-driving-based robots can solve problems caused by manpower. Self-driving-based quarantine robots can continuously prevent the spread of harmful viruses and diseases in public institutions and hospitals without additional manpower. The location of the autonomous driving function was estimated by applying the Pinnacle filter algorithm, and the UV sterilization system and chlorine dioxide injection system were applied for quarantine. The driving time is more than 3 hours and the position error is 0.5m.Soon, the stop-avoidance function was operated at 95% and the obstacle detection distance was 1.5 m, and the automatic charge recovery was charged by moving to the charging cradle at the remaining 10% of the battery capacity. As a result of quarantine with an unmanned quarantine system, UV sterilization is 99% and chlorine dioxide is sterilized more than 95%, which can contribute to reducing enormous social costs.

Fabrication and Temperature Compensation of Silicon Piezoresistive Absolute Pressure Sensor for Gas Leakage Alarm System (가스누출 감지용 실리콘 압저항형 절대압센서의 제조 및 온도보상)

  • Son, Seung-Hyun;Kim, Woo-Jeong;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.171-178
    • /
    • 1998
  • Silicon piezoresistive absolute pressure sensor for gas leakage alarm system was developed. This sensor must operate normally in the range of $0{\sim}600\;mmH_{2}O$ pressure, and $0{\sim}100^{\circ}C$ temperature. To make the most of this sensor for gas leakage alarm system, gas must not leak from the sensor itself when the diaphragm of the sensor fractures. Thus, the sealed diaphragm cavity was anodically bonded to pyrex 7740 glass under the condition of $10^{-4}$ torr, at $400^{\circ}C$. The sensitivity of developed sensor was $4.06{\mu}V/VmmH_{2}O$ for $600\;mmH_{2}O$ full-scale pressure range. And temperature compensation method of this sensor is to change bridge-in put-voltage linearly in proportion to the temperature variation by using diode(PXIN4001) or Al thin film resistor. By these methods the temperature effect in the range of $0{\sim}100^{\circ}C$ was compensated over 80 % for offset drift, 95 % for sensitivity.

  • PDF

Modeling and Simulation of the Cardiovascular System Using Baroreflex Control Model of the Heart Activity (심활성도 압반사 제어 모델을 이용한 심혈관시스템 모델링 및 시뮬레이션)

  • Choi Byeong Cheol;Jeong Do Un;Shon Jung Man;Yae Su Yung;Kim Ho Jong;Lee Hyun Cheol;Kim Yun Jin;Jung Dong keun;Yi Sang Hun;Jeon Gye Rok
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.565-573
    • /
    • 2004
  • In this paper, we proposed a heart activity control model for simulation of the aortic sinus baroreceptor, which was the most representative baroreceptor sensing the variance of pressure in the cardiovascular system. And then, the heart activity control model composed electric circuit model of the cardiovascular system with baroreflex control and time delay sub-model to observe the effect of time delay in heart period and stroke volume under the regulation of baroreflex in the aortic sinus. The mechanism of time delay in the heart activity baroreflex control model is as follows. A control function is conduct sensing pressure information in the aortic sinus baroreceptor to transmit the efferent nerve through central nervous system. As simulation results of the proposed model, we observed three patterns of the cardiovascular system variability by the time delay. First of all, if the time delay over 2.5 second, aortic pressure and stroke volume and heart rate was observed non-periodically and irregularly. However, if the time delay from 0.1 second to 0.25 second, the regular oscillation was observed. And then, if time delay under 0.1 second, then heart rate and aortic pressure-heart rate trajectory were maintained in stable state.