• Title/Summary/Keyword: 이상류 동축노즐

Search Result 2, Processing Time 0.017 seconds

A Study on the Effect of Flowrate on the Drop size from Two-Phase Coaxial Nozzle (이상류 동축노즐의 액경에 미치는 공급유량의 영향에 관한 연구)

  • 윤석주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.933-942
    • /
    • 1992
  • The effects of the folwrate on the dropsize from the two-phase coaxial nozzle are investigated by using the direct photographic method and the empirical equation is obtained. For the photography, the light source which the life time is the order of 100ns is fabricated and the lens is the zoom lens which has the MICRO function with a teleconvertor. The distillated water and the compressed air of the surrounding temperature are injected and atomized. For the purpose of the exact adjustment and measurement of the flowrates, the two rotameters are used. As a result of this study, the sauter mean diameter of droplets has a tendency for a logarithmic function with air flowrate and for a exponential function with water flowrate.

A study on the spray characteristics of a coaxial nozzle by LDV measurement (LDV계측에 의한 동축노즐의 분무특성 연구)

  • 윤석주;노병준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1613-1620
    • /
    • 1990
  • For the purpose of the study on the spray characteristics of a coaxial nozzle, the measurement of the velocity and size of droplets, concentration, and the statistical correlation coefficient between the fluctuation of the velocity and that of the corresponding drop diameter have been carried out. Various method of simultaneous measurement of velocity and drop size have been developed from LDV techniques. The technique used here belongs to the method that supposed by Yule, Holve and Self. It has the advantages of making use of a standard LDV apparatus to which minor modifications have been brought, photomultiplier is equipped with a slit instead of a pinhole and observed the measuring volume at an angle of 90.deg.. The voltage supplied by the photomultiplier has undergone an appropriate analog and digital processing. The experimental results give a good idea of the two phase flow organization and can be helpful to find a drop diffusion model when suitable data are imput.