• 제목/요약/키워드: 이복희

검색결과 459건 처리시간 0.041초

분포정수회로모델을 이용한 수직 접지전극의 접지임피던스의 분석 (Analysis for the Grounding Impedance of Vertical Grounding Electrodes using the Distributed Parameter Circuit Model)

  • 이복희;김종호;최종혁
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1103-1108
    • /
    • 2010
  • A grounding electrode has the transient grounding impedance characteristics against lightning surges. So the performance of grounding electrodes should be evaluated as a grounding impedance as well as the ground resistance. The frequency-dependent grounding impedance is varied with the shape and size of grounding electrode and is divided into both inductive and capacitive behaviors. This paper presents a theoretical analysis for the grounding impedance determined by the size of grounding electrode using the distributed parameter circuit model. EMTP and Matlab programs were used in calculating the frequency-dependent grounding impedances of vertical grounding electrodes. It was found that the frequency-dependent grounding characteristics of vertical grounding electrodes are characterized by the distributed parameters which are changed in the dimension of grounding electrodes.

매설지선의 유효길이 산정에 관한 이론적 해석 (Theoretical Analysis of Determination of Effective Length of Counterpoise)

  • 이복희;김정철;김종호;유재덕;김동규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1420_1422
    • /
    • 2009
  • Lightning currents are one of major influences on the dynamic performance of counterpoise. High lightning current causes the dynamic grounding performance of counterpoise due to very fast fronted pulses. The previous analysis has often been based on quasi-static approximation that can not be applicable to very fast fronted pulses. To extend the analysis for fast fronted pulses in this paper, the full-wave analysis method based on the rigorous electromagnetic-field theory approach is used and the effects of the ionization of the soil are disregarded. Based on the simulation results, the empirical formulas applicable for slow and fast fronted lightning current pulses are reviewed; therefore, the validity of the theoretical approach is verified through comparison between the calculated and measured results.

  • PDF

수직접지전극의 임계길이 산정 (Computation of Critical Length for Vertical Grounding Electrode and Counterpoise)

  • 이복희;조정현;이봉;김종호;이승주;이강수;김기복;김태기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1491_1492
    • /
    • 2009
  • The impedance of a vertical grounding electrode is not lowered by expanding the dimension of the grounding electrode, and the length of thr vertical grounding electrode which shows the minimum value of the grounding impedance for each condition of frequency and soil characteristics is existent, and it is defined as Critical length. In this paper, the critical lengths for the vertical grounding electrodes are calculated by using the distributed parameter circuit model. The adequacy of the simulations has been confirmed by comparing the simulated results with the measured results.

  • PDF

대전류 임펄스에 대한 소규모 메쉬전극의 과도접지임피던스 특성 (Characteristics of Transient Ground Impedance of a Scaled Grounding Grid on the High Current Impulse)

  • 이태형;조성철;엄주홍;유양우;이복희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1418_1419
    • /
    • 2009
  • This paper presents the transient impedance when high current impulse up to 5 kA is applied to a scaled grounding grid in test field. For a realistic analysis of transient impedance on the high current impulse in the ground systems, grounding electrode installed outdoors and impulse current generator was used. The results were discussed based on its voltage and current trace, impulse impedance and V-I curve.

  • PDF

대지구조에 따른 대지표면전위의 분석 (Analyses of Earth Surface Potentials Depending on Soil Structures)

  • 이복희;백영환;정현욱
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1796-1801
    • /
    • 2007
  • This paper presents electric potential rise on the surface of the earth due to ground currents. It is the aim of this paper to propose fundamental data relevant to the earth surface potentials depending on the soil structures. The earth potential rise, touch and step voltages in the immediate vicinity of the ground rod of a distribution pole were measured and analyzed. The results described in this paper are based on laboratory measurements which were intended to simulate conditions existing in actual installations. As a result, the earth surface potential rise, touch and step voltages strongly depend on the soil structure. The highest earth surface potential occurred in the vicinity of the top of ground rod. When the ground rod was installed in the distance range of $1{\sim}1.5\;m$ from distribution pole, the highest touch voltages appeared near the place of 1 m on the straight line connecting the distribution pole to ground rod.

접지전류의 주파수에 따른 수직 접지전극 주변에서 전위간섭 영향 분석 (An Analysis of Potential Interference Effects in the Vicinity of Ground Rod Depending on Frequency of Ground Currents)

  • 이복희;조용승;최종혁;양순만
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.88-93
    • /
    • 2011
  • When the ground current is injected into the adjacent ground electrode, the potential interference is caused between ground electrodes, the ground potential interferences have been largely studied with power frequency fault currents. Many attempts to find the frequency-dependent grounding impedance report that the high frequency grounding impedance is very different with the ground resistance. This paper presents experimental data on the frequency-dependent potential interference effects in the vicinity of ground rod. The ground potential rises around the test ground rod of 4 or 6[m] were measured and discussed. As a result, the ground potential rises and potential interference factor are decreased with decreasing the grounding impedance. It was found that the lowering of grounding impedance is critical to reduce the ground potential interference effects.

임펄스전압에 의한 수중방전특성에 대한 연구 (The Study of Underwater Discharge Characteristics against impulse voltage)

  • 이복희;최종혁;박건춘;이봉;김회구;이강수;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.271-273
    • /
    • 2007
  • This paper presents the experimental results of underwater discharges in 25 mm point-plane gap caused by impulse voltage. Discharge phenomena were observed by digital cameras and recorded by oscilloscope. As a result, discharge patterns in positive and negative polarity have different shapes according to applied voltage amplitudes. The positive discharge is like root but the negative discharge is similar to bush. As the voltage is increased, the discharge routs are thick and have more branches. Also the time to breakdown is inversely proportional to voltage.

  • PDF

중첩전압(직류 +60Hz 교류)에서 18kV 배전용 피뢰기의 전기적 특성 (The electrical properties of in 18kV ZnO surge arrestor with mixed direct and 60Hz Alternating Voltage)

  • 이복희;이승주;이수봉;정동철;백영환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.291-294
    • /
    • 2007
  • This paper preserts the characteristics of leakage currents flowing through 18 kV zinc oxide (ZnO) surge arrester under the mixed DC and AC voltages. The I-V curves of ZnO surge arrester were measured as a function of the voltage ratio K The I-V curves under the mixed DC and AC voltages lay between the pure DC and AC characteristics, and the cross-over phenomenon in I-V curves was observed at the low current region As a result, the increase of DC component to mixed voltages causes the increase of resistive component of total leakage current th ZnO surge arrester.

  • PDF

배전용 ZnO 피뢰기 소자의 열적/전기적 파라미터 분석에 관한 연구 (A study on analysis of thermal and electrical parameters of the ZnO arrester block)

  • 이복희;이수봉;이승주;전병욱;김동성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.353-356
    • /
    • 2007
  • This paper presents the thermal and electrical characteristics of ZnO arrester blocks under the AC voltages. The leakage currents of ZnO arrester blocks were measured as a function of time. The temperature distributions of ZnO arrester blocks were observed by the forward looking infrared camera The degradation and thermal runaway of ZnO arrester blocks were closely related with the temperature limit of ZnO arrester blocks which decided heat generation and dissipation As a result, the degradation and thermal runaway of ZnO arrester blocks depend on the temperature and leakage current of ZnO arrester blocks.

  • PDF

종속 접속된 전압제한형 서지방호장치의 에너지협조 (Energy Coordination of Cascaded Voltage Limiting Type Surge Protective Devices)

  • 이복희;신희경
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.29-35
    • /
    • 2013
  • For the purpose of designing and applying optimum surge protection, one of the essential points is to take into account the energy coordination between cascaded surge protective devices(SPDs) and it is important to obtain an acceptable sharing of the energy stress between two cascaded SPDs. In this paper, in case of two voltage-limiting SPDs connected in parallel, the amount of splitting impulse current and energy that flow through each SPDs is investigated as a function of the protective distance. As a result, the energetic coordination between cascaded SPDs is strongly dependent on the voltage protection level of SPDs and the protective distance. It was confirmed that the sharing of the energy between two cascaded SPDs and the limited voltage levels are appropriate when the voltage protection levels of both upstream and downstream SPDs are the same.