The Analysis for the grounding impedance influenced by the ground rod's dimension (접지임피던스에 대한 접지봉 크기의 영향 분석)

  • Lee, Bok-Hee;Joe, Jeong-Hyeon;Shin, Hee-Kyung;Lee, Kang-Soo;Khoa, Hoang-Dang;Kim, Jung-Cheol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.333-336
    • /
    • 2008
  • This paper resents a theoretical analysis for the grounding impedance influenced by the ground rod's dimension using the distributed parameter model. In this paper, EMTP and Matlab Program were used to simulate the distributed parameter model and to analyze the frequency-dependent characteristics of the ground rods. We compared two kinds of ground rods having different dimensions and the frequency-dependent characteristics of two ground rods were quite different from each other. It is estimated that these different characteristics are caused by the distributed parmeters which are changed by the length of ground rod.

  • PDF

The transient grounding impedance measurment of large grid grounding electrodes (대규모 그리드 접지전극의 과도접지임피던스의 측정)

  • Jeon, Byung-Wook;Lee, Su-Bong;Li, Feng;Lee, Seung-Ju;Jung, Dong-Cheol;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.69-72
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of large grid grounding system associated with the injection point of impulse current The measurement methods consider two possible errors in the grounding-system impedances: (1) ground mutual resistance due to current flow through ground from the ground electrode to be measured to the current auxiliary, (2) ac mutual coupling between the current test lead and the potential test lead The test circuit was set to reduce the error factors. The transient grounding impedance depends on the rise time and injection point of impulse current It is effective that grounding conductor is connected to the center of the large grid grounding system.

  • PDF

Characteristics of Potential Gradient for the Type of Structure Grounding Electrode (구조체 접지전극의 유형에 따른 전위경도 특성)

  • Gil Hyung-Jun;Choi Chun-Seog;Kim Hyang-Kon;Lee Bok-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.8
    • /
    • pp.371-377
    • /
    • 2005
  • This paper Presents the Potential gradient characteristics of structure grounding electrode when a test current flows through grounding electrode. In order to analyze the potential gradient of ground surface on structure grounding electrode, the reduced scale model has been used. The potential gradient has been measured and analyzed for types of structure using the hemispherical grounding simulation system in real time. The structures were designed through reducing real buildings and fabricated with four types on a scale of one-one hundred sixty. The supporter was made to put up with weight of structure and could move into vertical, horizontal, rotary direction. When a test current flowed through structure grounding electrodes, ground potential rise was the lowest value at electric cage type(type B). According to resistivity and absorption percentage In concrete attached to structure, the potential distribution of ground surface appeared differently.

Grounding Electrode Design for the Reduction of Hazardous Voltage in Lightning Protection (위험전압 저감을 위한 피뢰설비용 접지전극의 설계)

  • Lee, B.H.;Lee, S.C.;Eom, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2071-2073
    • /
    • 2000
  • Grounding electrode design is an important part in lightning protection, and the limit of hazardous voltages (step and touch voltages) below the permissible voltage for human body has been the main goal of grounding electrode design. In this paper, the grounding electrode for the reduction of hazardous voltages was designed and evaluated newly. It was known that the inclined auxiliary grounding conductors installed outside the grounding mesh grid are very effective to reduce the step and touch voltages.

  • PDF

Measurements of the Magnetic Fields Produced by Electric Home Appliances (가정용 전기기기에서 발생하는 자장의 측정)

  • Lee, B.H.;Park, J.W.;Eom, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2204-2206
    • /
    • 2000
  • In this paper, the magnetic fields measured experimentally from the electric home appliances were evaluated and the data were discussed on the bases of the international institutes recommendations. It is difficult to insulate magnetic flux completely from electric home appliances and impossible to simulate theoretically because of the different directions and magnitudes of magnetic fields according to the internal current of electric home appliances. The experimental measurements of magnetic flux density were carried out according to the increment of distance in the vicinity of electric home appliances. The magnetic flux density produced by the electric home appliances was drastically dropped with the increment of distance. The measured and analysed results of electric home appliances of 15 including computer monitor, TV, etc. were presented.

  • PDF

Change of the Microstructure of ZnO Arrester block by Lightning Surge Current and Ageing test (뇌서지전류와 Ageing에 의한 산화아연형 피뢰기 소자의 미세구조변화)

  • Lee, Bok-Hee;Kang, Sung-Man
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1877-1879
    • /
    • 2000
  • This paper deals with the change of the micro-structure of ZnO associated with lightning surge current and ageing test. In this work, a surge current generator which can produce 8/20 [${\mu}s$], 6 [kA] impulse current is designed and fabricated to simulate the lightning impulse current. The residual voltage and leakage current flowing to ZnO blocks are observed. Also a compensation circuit was used in resistive current measurement. The micro-structures of ZnO arrester block were significantly changed by lightning surge current and accelerated temperature ageing test.

  • PDF

The first corona inception characteristics in $SF_6$ gas and $SF_{6}-N_{2}$ mixtures ($SF_6$ 기체와 $SF_{6}-N_{2}$ 혼합기체의 초기코로나 특성)

  • Lee, B.H,;Kim, J.I.;Park, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2002-2004
    • /
    • 2000
  • The discharge processes in electro-negative gases with non-uniform field gape are composed of the formation of pulsed streamer corona, the transition of the streamers into leader step, the temporal development of the leader channel, and the stepped propagation of leader through the gap. In this paper, the first corona inception characteristics in $SF_6$ gas and $SF_{6}-N_{2}$ mixtures, related to the propagation of loader and the space charge effect, were experimentally investigated with positive and negative transient impulse voltages.

  • PDF

Breakdown Characteristics of $SF_{6}-N_{2}$ Mixtures in Nonuniform electric Field (불평등전계 중에서 $SF_{6}-N_{2}$ 혼합기체의 절연파괴 특성)

  • Lee, Bok-Hee;Lee, Kyoung-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1999-2001
    • /
    • 2000
  • Impulse breakdown voltage characteristics of sulphur-hexafluoride/nitrogen ($SF_{6}-N_{2}$) mixtures were presented. The applied voltages were the positive and negative lightning impulse (1.2/44${\mu}s$) and oscillating impulse ($0.4{\mu}s$/2.08MHz) voltages. The predischarge current was observed to clarify the breakdown mechanism. The electrode system was consisted of plane to plane configuration with a needle-shaped protrusion whose length and diameter are 10mm and 1mm. The measurements were carried out at the gas pressure of mixtures up to 0.5MPa with nitrogen concentrations varying from 5 to 20%. The electrical breakdown in $SF_{6}-N_{2}$ mixtures develops with steplike pulses in leader mechanism. The minimum breakdown voltages for the negative lightning and oscillating impulse voltages were higher than those for the positive.

  • PDF

A Research on the Solution of the Potential Interferences of Isolation Grounding Systems (독립접지방식의 전위간섭 문제 해결을 위한 연구)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Kil, Hyung-Jun;Han, Woon-Ki;Kim, Hyo-Jin;Lee, Hyung-Kyon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.49-51
    • /
    • 2005
  • This paper presents the potential interferences in various grounding electrode systems. The ground potential rise and potential interference coefficients were calculated as a function of the configuration and size of grounding electrodes and the distance between grounding electrodes. The potential rise and potential interference coefficient strongly depend on the distance between grounding electrodes, the shape and size of grounding electrodes.

  • PDF

Measurement of the Ionization Coefficient in Gases by the Luminous-flux Method (광속법을 이용한 기체의 전이계수 측정)

  • 백용현;하성철;이복희;김희택;김정섭
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.7
    • /
    • pp.289-296
    • /
    • 1985
  • The Townsend primary ionization coefficient a was measured by the luminous-flux method using the fact that the intensity of radiant light is proportional to electron density in the townsend discharge domain. The ranges of measurements were 15for He gas and 10

  • PDF