• Title/Summary/Keyword: 이미징장비

Search Result 27, Processing Time 0.025 seconds

Process of Collection for a Removable Storage Device Image Using a Software (소프트웨어를 이용한 이동식 저장매체 이미지 수집 절차)

  • Baek, Hyun Woo;Jeon, Sang Jun;Lee, Sang Jin
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.1
    • /
    • pp.17-24
    • /
    • 2017
  • As the prevalence of removable device, critical intelligences are often stored in the removable device. For that reason, in seizure and search, the removable device became a important evidence of while it could be has a salient key for prove a crime. When we acquired a removable device for proof, we image it by a imaging device or software with a write protection. However, these are high-priced exclusive equipments and sometimes it could be out of order. In addition, we found that some secure USB and inbuilt vaccine USB are failed to connect to the imaging device. Therefore, in this paper, we provide a suitable digital evidence collection procedure for real.

광학과 첨단영상이미징 기술의 '가교역할'및 고부가가치 응용기기 개발에서 '두각'

  • Park, Ji-Yeon
    • The Optical Journal
    • /
    • s.106
    • /
    • pp.36-38
    • /
    • 2006
  • (주)이즈미디어(대표ㆍ홍성철)는 컴퓨터이미징과 머신비전 소프트웨어 기반기술을 바탕으로 최근 폭발적인 성장세를 지속하고 있는 카메라폰과 관련한 렌즈모듈 검사장비를 주력으로 선보이며 시장에서 입지를 구축해 나가고 있다. 다양한 용도의 카메라를 만드는 것에서부터 평가하는 기술까지 고루 갖추고있는 이즈미디어는 첨단IT와 광학을 잇는 가교역할은 물론 다양한 고부가가치 응용광학계 개발을 통해 시너지를 바휘하고 있다.

  • PDF

An ECG Document Imaging System based on Neural Network and Graphic Techniques (신경망과 그래픽 기법을 이용한 심전도 결과지 이미징 시스템)

  • Kim Jin-Sang;Choi Sang-Yeol;Bae In-Ho;Kim Yun-Nyeon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.05a
    • /
    • pp.269-272
    • /
    • 2006
  • 병원의 각종 측정 장비에서 출력되는 결과지나 의사들이 작성한 기록지를 스캔하여 이미지형태로 저장하는 이미징 시스템 개발이 크게 요구되고 있다. 본 논문에서는 신경망과 그래픽 기법을 사용하여 대학병원 심전도실에서 사용되는 여섯 종류의 심전도 출력지를 이미지 형태로 저장하고 검색하는 이미징 시스템의 설계와 구현에 대해 논하였다. 구현된 시스템은 여섯 종류의 심전도 출력지를 분류하고, 분류된 각 출력지에 인쇄된 중요한 측정 데이터를 인식하여 데이터베이스에 저장한다. 심전도 출력지의 분류는 각 샘플 서식들의 평균 히스토그램을 구한 다음 새로운 출력지가 들어올 때 평균 히스토그램과의 거리가 가장 가까운 출력지로 분류하는 nearest-neighbor 방법을 사용하였다. 출력지에 인쇄된 데이터의 인식을 위해 먼저 XML로 작성한 출력지별 추출 정보를 기반으로 스캔한 이미지의 영역 분할 작업을 수행한다. 분할된 영역들은 신경망을 이용해 문자 인식을 하고, 인식된 문자들이 데이터베이스의 해당 속성값으로 저장된다. 스캔한 출력지는 의사들이 주석을 붙이거나 조건 검색을 위해 이미지 형태로 저장된다.

  • PDF

P & I 2010 리뷰 - 사진인들의 축제, '2010 서울국제사진영상기자재전' 지상중계 - "최첨단 디지털 이미징 기술이 빚어낸 신제품 열전"

  • Park, Ji-Yeon
    • The Optical Journal
    • /
    • s.128
    • /
    • pp.54-61
    • /
    • 2010
  • 아시아 최고의 사진영상분야 전시회로 손꼽히는 '2010 서울국제사진영상기자재전' (이하 P&I 2010)이 지난 4월 29일부터 5월 2일까지 나흘간 서울 코엑스 본관 1층 A홀에서 성황리에 펼쳐졌다. 올해로 19회째를 맞이한 이 전시회에는 삼성을 비롯한 캐논, 니콘, 소니, 올림푸스, 파나소닉 등 디지털 카메라 제조사와 관련 주변기기 및 액세서리 업체 등 총 112개 업체가 참가하여 527부스 규모로 전년대비 28%나 증가한 역대 최대 규모로 치러졌다. 특히 올해 전시회의 화두는 최첨단 디지털이미징 기술을 바탕으로 한 '하이브리드 디지털 카메라'로 사진인들로부터 뜨거운 관심을 받았다. 또한 새로운 기능의 출력장비를 비롯하여 다양한 사진 소프트웨어, 사진 액세서리, 사진 스튜디오 관련 장비 등을 한 자리에서 봄으로써 최신 기술동항의 흐름을 파악할 수 있는 좋은 기회가 되었다. 올해 전시기간동안 6만7052명의 참관객들이 발걸음을 해 사진영상분야에 대한 소비자들의 뜨거운 관심도를 확인할 수 있었다.

  • PDF

Color Scanner Characterization to Overcome the Metamerism Problem by Using the Reflectance Values (Reflectance 값을 이용하여 Metamerism 문제를 극복하는 칼라 스캐너 특성화)

  • 윤창락;강병호;김진서;김홍기;한규서;조맹섭
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10c
    • /
    • pp.494-496
    • /
    • 1998
  • 디지털 이미징(Digital Imaging) 분야에서 칼라 스캐너와 칼라 디지털 카메라와 같은 입력 장비들을 통하여 획득된 디지털 이미지는 장비 의존적인(Device Dependent) RGB칼라값으로 표현된다. 이러한 장비 의존적인 디지털 칼라 이미지는 인간 시각 체계의 칼라 인지 능력과 일치하지 않으므로 왜곡된 칼라를 제공하게 된다. 이러한 문제를 해결하기 위해서 장비 의존적인 RGB 칼라값을 장비 독립적인(Device Independent) XYZ 칼라값으로 변환하는 다양한 연구가 수행중이다[1-3]. 그러나, 이러한 연구 방법들은 서로 다른 Reflectance 값을 가지는 두 칼라가 특정한 환경하에서 동일한 XYZ 칼라값을 가지고, 또 다른 환경하에서 서로 다른 XYZ 칼라값을 가지는 Metamerism 문제를 해결할 수 없다. 본 논문은 이러한 Metamerism 문제를 해결하기 RGB 칼라값을 Reflectance 값으로 변환하였고, 기존의 연구 결과와 비교하였다.

  • PDF

A study on the tumor induced microvasculature using hyperspectral imaging system (초분광 이미징 시스템을 이용한 암 혈관 분석에 대한 연구)

  • Choe, Se-woon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.622-624
    • /
    • 2015
  • Tumor hypoxia caused by the unique characteristics of solid tumor sites such as lowered vascular density, irregular vasculature, longitudinal oxygen gradient, and unbalanced oxygen consumption has decreased therapeutic efficacy in several clinical trials such as radiation, chemotherapy, and surgery. Hence, tumor oxygenation studies at microvascular levels are important to provide better understanding of the complexity of microvasculature oxygen transport and exchange with tissue. However, polarographic microelectodes, was employed to measure $pO_2$ at the microvasculature level, but it is difficult to perform and does not provide significant spatial and temporal information of oxygen delivery. In this research, we introduce the hyperspectral imaging system able to provide a wide range of vascular characteristics by spatial maps on hemoglobin saturation information for better understanding of the relationship between blood oxygen delivery, hypervascularity, aberrant angiogenesis at microvasculature levels during tumor growth.

  • PDF

Application of Hyperspectral Imaging System to Analyze Vascular Alteration for Preclinical Models (전임상 혈관분석을 위한 초분광 이미징 시스템의 활용)

  • Choe, Se-Woon;Woo, Young Woon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.4
    • /
    • pp.69-76
    • /
    • 2015
  • We present microscopy based hyperspectral imaging system that successively shows high spatial (micrometer) and temporal resolutions (milisecond), and acquired pseudocolor hemoglobin saturation map a result of various image processing techniques can provide additional information such as oxygen transport, abnormal vascularity and therapeutic effects besides structural and physiological measurements in various diseases. To increase understanding of vascular defects several optical methods of imaging for preclinical/clinical assessment have been developed so far. However, they have some limitations for outcoming resolution and user satisfaction level compared to its cost. A hyperspectral imaging system has shown a wide range of vascular characteristics associated with hypervascularity, aberrant angiogenesis or abnormal vascular remodeling in many diseases. This vascular characteristic is considered as a key component to diagnose and detect a type of disease as evidenced by them.

첨단 의료장비분야 -뇌단층촬영기(fMRI)

  • Korea Optical Industry Association
    • The Optical Journal
    • /
    • s.100
    • /
    • pp.74-81
    • /
    • 2005
  • fMRI라고 하는 것은 뇌 속의 산소흐름과 같은 역동적인 상황의 촬영이 가능한 뇌단층 촬영기로서 4차원적으로 매순간 변화하는 것을 곧바로 측정할 수 있는 최첨단 의료기기이다. 거짓말을 할 때에는 전두엽이 활성화되어, 활성화된 전두엽의 뇌스캔을 이용하여 범인의 거짓말을 탐지할 수 있다는 것이다. 꼭 이런 목적이 아니더라도 알츠하이머 등의 뇌기능 저하에 따른 질병 연구와, 자극에 대해 우리의 뇌가 어떻게 반응하는지 살필 수 있어 무궁무진한 뇌과학 분야에 유용하게 이용될 수 있다. 본 보고서는 뇌기능을 이미징할 수 있는 fMRI 분야에 대한 특허를 다각도로 분석해 봄으로써, 해당 기술분야의 흐름을 파악하고 앞으로의 동향을 예측하여 적절한 대응과 연구개발에 목적을 두고 작성되었다.

  • PDF

단원자 팁 기반 가스장 이온빔(Gas Field Ionization Beam)생성

  • Park, In-Yong;Jo, Bok-Rae;Han, Cheol-Su;An, Jong-Rok;;Kim, Ju-Hwang;Sin, Seung-Min;An, Sang-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.402.2-402.2
    • /
    • 2014
  • 과학과 기술이 발전할수록 나노크기를 넘어서 나노 크기미만의 관찰 분해능과 가공능력이 필수로 요구되어 측정장비와 가공장비의 연구 및 개발이 매우 중요하다. 현재는 주사전자현미경과 투과전자현미경의 발달로 나노크기 이하의 이미징 분해능에는 도달하였지만, 전자 입자의 가벼운 무게 때문에 가공측면에서는 한계를 가지고 있다. 또한 지난 수십 년간 정밀가공에 사용된 갈륨이온 LMIS(Liquid Metal Ion Source)기반의 집속이온빔 시스템은 수십 nm의 가공정밀도를 가지지만 10 nm 미만의 가공정밀도까지 구현하기에는 현재 기술적인 한계로 힘들다. 나노크기 이하의 이미징 분해능과 수 nm의 가공정밀도를 갖는 이온현미경이 최근에 상용화되어 판매되고 있는데, 이 이온 현미경에 사용되는 것이 가스장 이온원(GFIS:Gas Field Ionization Source)이다. 가스장 이온원은 작은 발산각, 작은 가상 이온원 크기 그리고 좁은 에너지 퍼짐의 특징을 가지며 이에 따라 구면수차 및 색수차에도 둔감한 특징을 가지고 있다. 또한 LMIS 는 갈륨이온이 시편속에 파고들어 시편의 물질 특성이 변화되는 문제가 있지만, GFIS에서는 주로 He, Ne 와 같은 불활성 기체를 주로 사용하므로 시편과 반응을 최소화 할 수 있는 장점도 있다. 위와 같은 특징을 갖는 이온빔을 GFIS 로 생성하고 이온현미경에 사용하기 위해서는 이온빔이 팁의 단원자 내지 수 개 정도의 원자에서 생성되도록 해야 한다. 본 연구에서는 GFIS 의 원리를 소개하고 장(전계)이온현미경(Field Ion Microscope)실험을 통하여 GFIS기반으로 생성된 이온빔의 형상을 보여준다. 또한 높은 각전류밀도 구현을 위하여 질소가스 에칭으로 텅스텐 팁 끝 단원자에서만 이온빔을 생성하고, 각전류 밀도 계산과 안정도 실험결과로 본 연구에서 개발한 이온원이 이온총으로서의 이온현미경 적용 가능성에 대해 보여준다.

  • PDF

Infrared Thermal Imaging for Quantification of HIFU-induced Tissue Coagulation (적외선 이미징 기반 HIFU 응용 조직 응고 정량화 연구)

  • Pyo, Hanjae;Park, Suhyun;Kang, Hyun Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.5
    • /
    • pp.236-240
    • /
    • 2017
  • In this paper, we investigate the thermal response of skin tissue to high-intensity focused ultrasound (HIFU) by means of infrared (IR) thermal imaging. For skin tightening, a 7-MHz ultrasound transducer is used to induce irreversible tissue coagulation in porcine skin. An IR camera is employed to monitor spatiotemporal changes of the temperature in the tissue. The maximum temperature in the tissue increased linearly with applied energy, up to $90^{\circ}C$. The extent of irreversible tissue coagulation (up to 3.2 mm in width) corresponds well to the spatial distribution of the temperature during HIFU sonication. Histological analysis confirms that the temperature beyond the coagulation threshold (${\sim}65^{\circ}C$) delineates the margin of collagen denaturation in the tissue. IR thermal imaging can be a feasible method for quantifying the degree of thermal coagulation in HIFU-induced skin treatment.