Bacteriological Monitoring of Radiology Room Apparatus in the Department of Radiological Technology and Contamination on Hands of Radiological Technologists (영상의학과 촬영실 장비와 방사선사의 손 오염의 세균학적 모니터링)

  • Kim, Seon-Chil
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.329-335
    • /
    • 2008
  • Distribution of microorganisms were examined for the bucky tables in the radiology rooms of the department of radiological technology, the aprons, handles of various apparatus, handles of mobile radiological apparatus, and hands of the radiological technologists. As a result, relatively larger amounts of bacteria were found on the handles of the mobile radiological apparatus and the aprons. Among the isolated bacteria, Acinetobacter baumanni (7.3%), Klebsiella pneumoniae (6.7%), Staphylococcus aureus (3.9%), Serratia liquefaciens (1.7%), Enterobacter cloaceae (0.6%), Providenica rettgeri (0.6%) are known as the cause of nosocomial infection (hospital acquired infection). In addition, similar colonies were also found on the hands of the radiological technologists such as microorganisms of Klebsiella pneumoniae (8.4%), Staphylococcus aureus (6.6%), Yersinia enterocolotica (5.4%), Acinetobacter baumanni (4.2%), Enterobacter cloaceae (2.4%), Serratia liquefaciens (1.8%), Yersinia pseuotuberculosis (18%), Enterobacter sakazakii (1.2%), and Escherichia coli (0.6%). In particular, this result indicates clinical significance since Staphylococcus aureus and Escherichia coli show strong pathogenicity. Therefore, a continuous education is essential for the radiological technologists to prevent the nosocomial infection.

  • PDF

Application of Mobile Hospital Computed Tomography in a State-Designated Medical Institution under the Coronavirus Disease 2019 (COVID-19) Situation by Example (코로나바이러스감염증-19 상황에서 일개 국가지정 의료기관의 이동형 병원 CT 활용 사례)

  • Shin, Hyeongho;Lee, Jungho;Kim, Kwanghun;Kim, Byeongjin;Jin, Sungchan;Park, Hyunmee
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.71-77
    • /
    • 2020
  • This study aims to explain the process of providing important medical images for the diagnosis of pneumonia caused by coronavirus disease 2019 (COVID-19) through the only mobile hospital computed tomography (CT) in Korea. Since January 28, 2020, medical imaging examinations have been provided to confirmed and suspected COVID-19 patients, and the quality of images was evaluated based on the objective and subjective indicators. In order to prevent the transmission in the hospital that may occur due to exposure to medical staff and general patients, personal protective equipment was worn and the separate route was used blocking human infection factors. For 11 weeks, a total of 185 tests were performed for 98 confirmed patients and 72 suspected patients. The average time to complete the test was 33 minutes. In the course of the test, no cross-infection cases were examined. During the outbreak of the COVID-19, the only mobile hospital CT room of Korea provided medical imaging examinations without infection among medical staff and patients and also provided adequate medical images without significant difference (p >0.05) in determining the degree of pneumonia progression compared to a stationary in-hospital CT.

A Study on Distortion and Dose of Images in Mobile Radiography (이동형 방사선검사에서 영상의 왜곡과 선량에 관한 연구)

  • Song, Hyeon-Seok;Lim, Cheong-Hwan;Jung, Hong-Ryang;Kim, Jong-Seong;Kim, Yeong-Ran;Jeong, Sung-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.305-312
    • /
    • 2022
  • The proportion and testing of portable radiation tests, which are limited at the request of the doctor, are gradually increasing only for patients in emergency situations and difficulties in moving. However, as there are many limiting factors compared to fixed devices, this study intends to measure and analyze the distortion of images according to the angle of the detector and the change in dose according to the position of the subject. For distortion experiments using a mobile radiation generator used in Hospital A, the SID was tilted by 110 cm, 14"×17" wireless FPD detector to 0°, -5°, -10°, -15°, -20°, and -35° to measure the change in area. The dose according to the location of the detector was analyzed on average by measuring the central dose at 110 cm of the SID and measuring the dose of 9 locations three times each. The analysis result of distortion by location according to the angle of the detector showed a statistically significant difference (f=58.74, p<0.000). Therefore, it can be seen that the angle of the detector and the tube is closely related to the distortion of the image. The difference in dose by location of the detector increased with respect to the center - pole, and decreased with the + pole. Tests using mobile radiation generators will require careful efforts by clinicians to position patients in the center of the detector for accurate diagnosis, and efforts will be made to level the angle between the mobile radiation generators and the detector.

동영상 처리에 의한 목적물 추출 및 이동 방향과 이동 속도 계측에 관한 연구

  • 이종형;황병원
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1987.04a
    • /
    • pp.56-59
    • /
    • 1987
  • In this study the moving information extraction techniques of moving objects are processed digital imaqe data by sampling three frames in a fixed-bacqround two-dimensional line sequence image the brightness of interframe are compared to extract difference image and difference image are two level formed and neighber averged From neigbber averaged image the parameters for recoqnition of the object are the number of contorur pixels, the number of vertex points and the distance between the vertex points Agtercomparing the same object the moving distance obtained from the coordinate which is constructed by the bit processing of the digital data and the moving velocity is obtained from the moving distance and the time interval between the first andsecond sampled frames.

  • PDF

Battery Type Surgical Handpiece Using Brushless DC Motor Drive (배터리형 외과수술용 핸드피스 브러시리스 직류 전동기 구동 드라이브)

  • Yu, Jae-Sung;Park, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.128-130
    • /
    • 2007
  • 외과수술용 핸드피스는 현재 국내 외 병원에서 사용되고 있는 수술 장비 중 필수 보유 장비이다. 선진 수술 기법인 인공관절 대체 수술 시 뼈(Bone)절단, 다듬질 구멍 등, 초 섬세 가공을 목적으로 하는 기기이다. 기존의 공압식(Air Type)은 수술 시 많은 양의 질소(N2 Gas)가 소모됨으로써 질소탱크 보관에 많은 공간이 필요하고 잦은 교체를 필요로 한다. 또한 기계소음과 공압식 호스의 이동으로 시술자와 환자사이에 불편함이 발생하고 감염의 위험성이 있으므로 최근에는 충전식을 선호하고 있다. 이러한 이유로 기존의 공압식을 대체할 배터리형 외과수술용 핸드피스를 연구하게 되었다.

  • PDF

Battery Type Surgical Handpiece Using Brushless DC Motor Drive (배터리형 외과수술용 핸드피스 브러시리스 직류 전동기 구동 드라이브)

  • Park, Sang-Hoon;Yoon, Yong-Ho;Lee, Byoung-Kuk;Won, Chung-Yuen;Jeon, Jae-Hong;An, Il-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.334-337
    • /
    • 2006
  • 외과수술용 핸드피스는 현재 국내 외 병원에서 사용되고 있는 수술 장비 중 필수 보유 장비이다. 선진수술 기법인 인공관절대체수술 시 뼈(Bone) 절단, 다듬질, 구멍등 초섬세 가공을 목적으로 하는 기기이다. 기존의 공압식(Air Type)은 수술 시 많은 양의 질소(N2 Gas)가 소모됨으로써 질소탱크 보관에 많은 공간이 필요하고 잦은 교체를 필요로 한다. 또한 기계소음과 공압식 호스의 이동으로 시술자와 환자사이에 불편함이 발생하고 감염의 위험성이 있으므로 최근에는 충전식을 선호하고 있다. 이러한 이유로 기존의 공압식을 대체할 배터리형 외과수술용 핸드피스를 연구하게 되었다.

  • PDF

Risk Factors for Depression of Patients with Tuberculosis in Tuberculosis Specialty Hospital (결핵전문병원에 입원한 결핵환자의 우울증위험인자)

  • Wang, Jung-Hyun;Park, Chul-Soo;Kim, Bong-Jo;Lee, Cheol-Soon;Cha, Boseok;Lee, So-Jin;Lee, Dongyun;Seo, Ji-Yeong;Ahn, InYoung;Baek, Jong Chul;Kang, Hyung Seok;Moon, Sung Ho
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.23 no.2
    • /
    • pp.114-120
    • /
    • 2015
  • Objectives : This study aimed to investigate the risk factors of depression for patients with tuberculosis(TB). Methods : A total of 57 patients with TB were recruited. All participants completed the Becks Depression Inventory-II for evaluating depressive symptoms. The risk factor for depression was analyzed by binary logistic regression analysis. Nomogram was performed for probability of depression. Results : Low body mass index(BMI, OR 0.801, 95% CI 0.65, 0.98), interruption of treatment for TB(OR 5.908, 95% CI 1.19, 29.41), past history of depression(OR 24.653, 95% CI 1.99, 308.44) were associated with increased risk for depression. The calibration curve for predicting probability of survival showed a good agreement between the nomogram and actual observation(Original C-index=0.789, bias corrected C-index=0.754). Conclusions : The result of the present study indicate that low BMI, interruption of treatment for TB, and past history of depression were risk factors for depression in patients with TB. The psychiatric intervention may be needed to prevent depression if the patients with TB have risk factor during treatment for TB.

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

Association Between Chronotype, Sleep Quality and Resilience as Well as Anxiety Among Medical Students (의과대학 학생들의 일주기 유형과 수면의 질 및 회복탄력성과 불안 증상의 관련성)

  • Jeein Kim;Bong-Jo Kim;Chul-Soon Lee;Boseok Cha;So-Jin Lee;Dongyun Lee;Jiyeong Seo;Jae-Won Choi;Young-Ji Lee;Eunji Lim
    • Sleep Medicine and Psychophysiology
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2022
  • Objectives: Our study aimed to investigate the relationship between the anxiety at first year and chronotype and sleep quality at third year in medical students. We also investigated the association between sleep quality, chronotype, depression and resilience at third year. Methods: Fifty two medical students (36 males, 69%, aged 21 ± 0.93) in first year, and forty four medical students (31 males, 70.5%, aged 23.05 ± 0.99) at third year answered Beck Depression Inventory 2, Beck anxiety inventory, Insomnia severity index-K, Composite scale of morningness and Conner-Davidson Resilience scale-10. Multiple linear regression analysises were performed to identify predictors of chronotype, sleep quality and resilience. Results: Higher anxiety (β = -0.434, p = 0.006) at first year was significant predictor of eveningness at third year, while lower anxiety score (β = 0.606, p < 0.001) at first year was significant predictor of sleep quality at third year. Lower sleep quality (β = -0.314, p = 0.042) and eveningness (β = 0.315, p = 0.041) were associated with low resilience at third year. Also, Lesser depression (β = -0.717, p < 0.001) was associated with higher resilience at third year. Conclusion: Our study showed that higher anxiety in first year had significantly related with eveningness and poor sleep quality at third year. In addition, higher sleep quality, morningness and less depression had significantly associated with better resilience at third year.

Validation of Electronic Foot Function Index in Patients with Foot and Ankle Disease: A Randomized, Prospective Multicenter Study (족부 족관절 질환 환자에서 전자식 족부 기능 지수의 인증: 임의 배정, 전향적, 다기관 연구)

  • Lee, Dong Yeon;Kim, Yu Mi;Lee, Jun Hyung;Kim, Jin;Kim, Ji-Beom;Kim, Bom Soo;Choi, Gi Won;Seo, Sang Gyo;Kim, Jun Beom;Park, Se-Jin;Kim, Yoon-Chung;Choi, Young Rak;Lee, Dong-Oh;Cho, Jae-Ho;Chun, Dong-Il;Kim, Hyong Nyun;Park, Jae-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.1
    • /
    • pp.24-30
    • /
    • 2019
  • Purpose: To evaluate the efficiency of the electronic foot function index (eFFI) through a prospective, random based, multi-institutional study. Materials and Methods: The study included 227 patients ranging in age from 20 to 79 years, visited for surgery in different 15 institutes, and agreed to volunteer. The patients were assigned randomly into a paper-based evaluated group (n=113) and tablet-based evaluated group (n=114). The evaluation was done on the day of hospital admission and the method was changed on the second day of surgery and re-evaluated. PADAS 2.0 (https://www.proscore.kr) was used as an electronic evaluation program. Results: There were no differences in age and sex in both groups. The intraclass correlation coefficient (ICC) evaluation revealed an eFFI ICC of 0.924, showing that both results were similar. The evaluation time was shorter in the tablet-based group than the paper-based group (paper vs tablet, $3.7{\pm}3.8$ vs $2.3{\pm}1.3minutes$). Thirty-nine patients (17.2%) preferred to use paper and 131 patients (57.7%) preferred the tablet. Fifty-seven patients (25.1%) found both ways to be acceptable. Conclusion: eFFI through tablet devices appears to be more constant than the paper-based program. In addition, it required a shorter amount of time and the patients tended to prefer the tablet-based program. Overall, tablet and cloud system can be beneficial to a clinical study.