• Title/Summary/Keyword: 이광용

Search Result 145, Processing Time 0.032 seconds

The Design of the Shared Memory in the Dual Core System (Dual Core 시스템에서 Shared Memory 기능 설계)

  • Jang, Seung-Ju;Lee, Gwang-Yong;Kim, Jae-Myeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.8
    • /
    • pp.1448-1455
    • /
    • 2008
  • This paper designs Shared Memory on the Dual Core system so that it operates a general System V IPC on the Linux O.S. Shared Memory is the technique that many processes can access to identical memory area. We treat Shared Memory in this paper among big two branches of Shared Memory which are SVR in a kernel step format. We design a share memory facility of Linux operating system on the Dual Core System. In this paper the suggesting design plan of share memory facility in Dual Core system is enhancing the performance in existing unity processor system as a dual core practical use. We attempt a performance enhance in each CPU for each process which uses a share memory.

The effect of the Modified Voiced Lip Trill (MVoLT) training on vocal changes of musical theater students (응용 입술 트릴 훈련이 뮤지컬 전공 학생의 음성 변화에 미치는 효과)

  • Lee, Seung Jin;Choi, Hong-Shik;Lim, Jae-Yol;Lee, Kwang Yong
    • Phonetics and Speech Sciences
    • /
    • v.10 no.4
    • /
    • pp.135-146
    • /
    • 2018
  • The Modified Voiced Lip Trill (MVoLT) training is a variant of voiced lip-till training characterized by increased loudness, lowered laryngeal position, and lip contact facilitated with fingers. The purpose of the current study was to assess the effect of the MVoLT training program on vocal changes of musical singing theater students. A total of 32 musical theater students (17 males and 15 females, age ranging from 18 to 29) participated in the study. For about three months, each participant was tutored using a systematic program focussing on the MVoLT training, accompanied by certain facilitating strategies. Pre- & post-training multi-dimensional vocal characteristics were assesed and compared. Results showed that cepstral peak prominence during vowel phonation increased after training, while its standard deviation and Cepstral Spectral Index of Dysphonia decreased. When an aerodynamic assessment was performed, maximum phonation time, subglottal pressure, mean airflow rate increased, while electroglottographic measures did not change. In addition, decreased psychometric measures, higher maximum pitch, and increased vocal range were noted after training. In conclusion, the MVoLT was proven to have a potential as an effective and safe training method for musical theater singing.

Development of Energy Efficiency Routing Technique for Mobile Ad-hoc Sensor Network (모바일 에드-혹 센서 네트워크를 위한 에너지 효율적 라우팅 기법 개발)

  • Lee, YangMin;Lee, KwangYong;Lee, JaeKee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.11a
    • /
    • pp.547-548
    • /
    • 2009
  • The development of USN(Ubiquitous Sensor Network) technology is creating numerous application areas. Although a network configuration with fixed sensors was the norm in the past, the coexistence of mobile and fixed sensor nodes is a new trend. Fixed sensor networks focused on the energy efficiency of nodes, but the latest studies consider guaranteeing the mobility of nodes and maintaining their connectivity, while remaining energy efficient at the same time. This paper proposes a routing protocol for a mobile ad-hoc sensor network that improves the mobility, connectivity and energy efficiency of nodes while allowing for the management and maintenance of a large number of nodes even in a complex communication environment where mobile and fixed nodes coexist. An algorithm for multi-hop multi-paths, a technique for topology reconfiguration by node movement prediction and vibration sensors, path setting for a large number of nodes, and efficient data transfer technology have been introduced to implement the modified LEAHC-AOMDV protocol. Furthermore, the excellence of this protocol was verified through a comparative experiment with the conventional LEACH protocol.

The Current Status of Workers at Major Industrial Health Institutions in South Korea (우리나라 산업보건 주요기관의 인력 현황)

  • Young Gyu Phee;Seung Won Kim;Sa Woo Lee;Gwangyong Yi
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.70 -77
    • /
    • 2023
  • Objectives: The purpose of this study was to identify information on the workers at major industrial health institutions. Methods: The subjects were employees at work environment measurement institutions, specialized health management institutions, special health examination institutions, and health checkup institutions. Data on these employees was identified by age, career, region, and qualification. Results: The sample totaled 6,449 workers at major industrial health institutions. The number of doctors, nurses, and industrial hygienists was identified at 4,609. For their age groups, 34.1% were in their 30s, and 56.3% had less than five years of work experience. The distribution by region was 24.3% in Gyeonggi-do Province, 12.7% in Seoul, and 8.7% in Gyeongsangnam-do Province. Conclusions: Information on occupational health human resources has been published irregularly and is limited by specialty. Therefore, it is necessary to systematize information on human resources and disclose it regularly so that supply and demand conditions can be predicted when establishing industrial accident prevention policies.

Sampling and Analytical Method for Linear Carbonates using GC/FID (GC/FID를 이용한 사슬형 카보네이트 3종의 측정·분석방법)

  • Miyeon Jang;Gwangyong Yi
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.455-463
    • /
    • 2023
  • Objectives: The aim of this study was to develop an air sampling and analytical method for estimating worker exposure to linear carbonate solvents and to evaluate the method. Methods: The target substances were three linear carbonates: DMC, DEC, EMC. GC/FID was used for sample analysis. Laboratory experiments were conducted to determine desorption solvents and sample capacity, and to evaluate storage stability, accuracy, and precision. Results: Coconut Shell Charcoal (CSC, 100/50 mg) was used as the air sampling media, and a desorption solvent of 5% methanol/95% dichloromethane was selected. Recommended sampling capacities were 1~11 ℓ for DMC, 1~18 ℓ for DEC, and 1~24 ℓ for EMC. The stability of three linear carbonates was demonstrated over 30 days in a refrigerator (4℃). Detection limits were determined as follows: DMC 0.26 ㎍/sample, DEC 0.24 ㎍/sample, and EMC 0.25 ㎍/sample. The total coefficient of variation was calculated as DMC 0.064, DEC 0.079, and EMC 0.07. Conclusions: This sampling and analysis method is suitable for estimating personal exposure to linear carbonates in the workplace.

Query Optimization with Metadata Routing Tables on Nano-Q+ Sensor Network with Multiple Heterogeneous Sensors (다중 이기종 센서를 보유한 Nano-Q+ 기반 센서네트워크에서 메타데이타 라우팅 테이블을 이용한 질의 최적화)

  • Nam, Young-Kwang;Choe, Gui-Ja;Lee, Byoung-Dai;Kwak, Kwang-Woong;Lee, Kwang-Yong;Mah, Pyoung-Soo
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.1
    • /
    • pp.13-21
    • /
    • 2008
  • In general, data communication among sensor nodes requires more energy than internal processing or sensing activities. In this paper, we propose a noble technique to reduce the number of packet transmissions necessary for sending/receiving queries/results among neighboring nodes with the help of context-aware routing tables. The important information maintained in the context-aware routing table is which physical properties can be measured by descendent nodes reachable from the current node. Based on the information, the node is able to eliminate unnecessary packet transmission by filtering out the child nodes for query dissemination or result relaying. The simulation results show that up to 80% of performance gains can be achieved with our technique.

Analytical method for analyzing formaldehyde using 2, 4-DNPH and gas chromatography/FID, NPD (2,4-DNPH와 가스크로마토그래프를 이용한 포름알데히드 분석방법)

  • Jeong, Jee Yeon;Park, Seung Hyun;Yi, Gwang Yong;Oh, Se Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.126-146
    • /
    • 2000
  • To develop and evaluate formaldehyde measurement method using 2,4-dinitro-phenylhydrazine (2,4-DNPH) coated sampler and gas chromatography, laboratory test and field test were conducted. Results of this study are as follows. Limit of detection(LOD) of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is $0.008{\mu}g/m{\ell}$ $0.060{\mu}g/m{\ell}$, $0.472{\mu}g/m{\ell}$ respectively. Coefficiency of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is 0.008, 0.009, 0.020 respectively. Desorption efficiency of sep-pak xposure aldehyde sampler and sorbent sample tube is 1.05(range : 0.99 - 1.12), 1.02(range : 0.99 - 1.06) respectively. Samples of sorbent sample tube and sep-pak xposure aldehyde sampler turned out to be stored at refrigerator, according to storage test results. Measurement methods of HPLC-UVD, GC-NPD, GC-FID, according to results of precision for the combined sampling and analytical procedure, became acceptable to OSHA evaluation standard. Field test using exposure chamber met the NIOSH overall uncertainty recommendation(less than 25%). Overall uncertainty of Sepak-HPLC(UVD), Tube-GC(NPD), Tube-GC(FID) is 11.0% - 17.0%. Consequently gas chromatography(GC-NPD, GC-FID) and high performance liquid chromatography(EPA TO-11) using 2,4-DNPH coated sampler for formaldehyde measurement turned out to be suitable to measure personal formaldehyde exposure at workplaces.

  • PDF

Evaluation of Industrial Hygiene Laboratories by on-Site Investigation for Revised Quality Control System (개정된 정도관리제도를 적용한 작업환경측정기관의 실험실 현장 평가)

  • Shin, Jung-Ah;Yi, Gwang-Yong;Park, Seung-Hyun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.243-249
    • /
    • 2013
  • Objectives: This study assessed the status of domestic industrial hygiene laboratories using data from on-site investigation for revision of quality control systems in 2012-2013. Methods: The target laboratories were 60 industrial hygiene laboratories chosen by random selection and nationwide distribution which had participated in on-site investigations for revision of quality control systems from March 2012 to August 2013. The investigation was performed on-site following standard quality control procedures. The score between each group was compared using Mann-Whitney and Kruskal-Wallis tests, and the correlation between analytical career, sex, academic major of analyst and score of analytical performance was expressed as Spearman's rank correlation coefficient. Results: The assessment revealed that the items to be improved, in sequence, were effort at staff training (score 65.5), ability to calculate data (score 73.4), establishment of internal quality control guidelines (score 75.7), laboratory facilities (score 77.1), degree of understanding and skill at gas chromatography (score 77.1). Analysis performance showed a positive correlation with career of analyst (r=0.56, p<0.01). Conclusions: The practice of on-site investigation for quality control systems showed the current status of industrial hygiene laboratories in the first trial. There were many laboratories which needed improvement and development of analytical systems. This assessment can provide information for the systematic operation and improvement of facilities at each laboratory. Further practice of this investigation will lead to a proficiency testing and accreditation system for autonomous quality control as is the practice in many countries, rather than mandatory practice by legal regulation.

A Review on Cases of Indium-related Occupational Diseases and Korean Indium-related Industries and Processes (인듐 관련 직업병 사례 및 국내 사업장 현황)

  • Yi, Gwang Yong;Park, Doo Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.299-306
    • /
    • 2013
  • Objectives: The purpose of this study is to provide current the recent information on indium-related adverse health effects and the Korean indium-related industries. Methods: Peer review papers were searched in environmental, occupational and medical journals with the keyword of 'Indium' and 'ITO' and reviewed. To determine the indium related industries and indium consumption amounts, references and database were investigated and analyzed. In addition, field walk-through surveys and interviews were conducted in order to collect field data and to ascertain the field situation for the processes and industries. Results: A total of 10 cases of indium lung diseases have been reported in series since the first case reported in 2001. Seven cases were found in Japan, two cases in the United States, and one in China. No indium lung case has been reported yet in Korea, but it is believed that there are high potential risks among workers in indium-related industries. There are four categories in indiumrelated- industry; indium production and smelting, manufacturing of indium products such as ITO target, the production of thin films of flat panel display, and indium recovery industry. We found that all these types of industries are operating in Korea. Therefore, it is necessary for industrial hygienists to understand the processes and industries related to indium as well as the adverse health effects of indium. Conclusions: It was found that all four categories of indium-related industry from the indium production to recovery industry are active in Korea. However, the adverse health effects of indium are not well recognized. Therefore, it is believed that there is a high risks in indium-related industry, and it is necessary to make emergency interventions.

Worker Exposure Assessment on Airborne Total Chromium and Hexavalent Chromium by Process in Electroplating Factories (도금업체 공정별 근로자의 총크롬 및 6가 크롬 노출 평가)

  • Yi, Gwang Yong;Kim, Boowook;Shin, Yong Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.1
    • /
    • pp.89-94
    • /
    • 2015
  • Objectives: The objective of this study was to determine characteristics of workers' exposures to airborne total and hexavalent chromium by job title in electroplating processes. Methods: Total Cr was determined through a modified method based on NIOSH Method 7024. Airborne hexavalent Cr, Cr(VI), was sampled and extracted according to NIOSH Method 7600 and analyzed at 520 nm using an ion chromatograph/visible detector. Results: The geometric mean(GM) of total Cr concentrations from all factories was $11.2{\mu}g/m^3$(GSD=4.9). The GM of Cr(VI) concentrations from all factories was $2.84{\mu}g/m$ (GSD=5.2), and the concentrations among factories were significantly different (p<0.05). The Cr(VI) levels were lower than total Cr levels. Total Cr exposure levels were highest among buffing workers ($21.6{\mu}g/m^3$), but Cr(VI) levels were highest among plating workers($4.15{\mu}g/m^3$). The concentrations of Cr(VI) and total Cr from plating tasks was highly correlated(r=0.91). Conclusions: In the electroplating industry, plating workers were mainly exposed to Cr(VI), but others were not. Oxidation-reduction states of Cr and job titles should be considered in the exposure or risk assessments of chrome electroplating factories.