• Title/Summary/Keyword: 이격공간

Search Result 179, Processing Time 0.023 seconds

Contributory Negligence Study on Traffic Accident in Area Between Crosswalk and Stop Line at Intersections (횡단보도와 횡단보도 정지선간 이격공간에서의 과실상계 연구)

  • 신성훈;장명순;김남현
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.5
    • /
    • pp.41-48
    • /
    • 2003
  • Korea Claim Adjustor Association(KCAA) defines the near pedestrian crossing accidents as those accidents that occurred in the area within 25m from pedestrian crossing on the arterial road and within 15m from pedestrian crossing on other classes of road. Accidents between pedestrian crossing and stop line are classified as the accident near pedestrian crossing. Reviewing of current statute and court precedent, three kinds of traffic accidents which are accidents occurred in the pedestrian crossing. near pedestrian crossing and the area between pedestrian crossing and stop line. should be distinguished by different pedestrian contributory negligence. To find out how different they are. we surveyed transportation society members about the contributory negligence of traffic accidents between pedestrian crossing and stop line and the results are as follows : (1) The current two classification of pedestrian crossing accidents and near pedestrian crossing accidents should be changed to three classification of pedestrian crossing accidents that includes accidents on pedestrian crossing, near pedestrian crossing and between pedestrian crossing and the stop line. (2) For the pedestrian's contributory negligence, the least reasonability to pedestrian is accident on the pedestrian crossing. The next one is the accident between pedestrian crossing and stop line and the last is the accident near pedestrian crossing. (3) Pedestrian contributory negligence for accident by space is recommended as 〈table 8〉, 〈table 9〉, 〈table 10〉. (4) Contributory negligence rate of the accident on the pedestrian crossing during red light should be modified to be less than that of near pedestrian crossing.

A study on the longitudinal optimum separated distance of tunnel face in 2-arch tunnel (2-Arch 터널의 막장면 종방향 적정 이격거리에 관한 연구)

  • Lee, Min-Kyu;Jeong, Ji-Su;Lee, Sung-Ki;Lee, Seung-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.4
    • /
    • pp.323-330
    • /
    • 2007
  • Recently, due to the effective land utilization and environmental protection, the construction of 2-arch tunnel has been gradually increased. In spite of this tendency, the mechanical information for the 2-arch tunnel, especially such as its behavior characteristics and mechanism are not enough. Therefore in this study, the theoretical and numerical studies on the behavior characteristics of 2-arch tunnel are carried out and longitudinal optimum separated distance of tunnel face is proposed by considering the analysis results from the behavior of advanced excavation of tunnel and stress of central pillar. As a result, longitudinal optimum separated distance of tunnel face is in 0.5D for the better safety of 2-arch tunnel by rapidly decreasing the stress concentration of central pillar.

  • PDF

Evaluation of Usefulness of Assertive Devices to Improve the Accuracy in Skull lateral X-ray Projection (두개골 측방향 X-선 촬영에서 정확도 향상을 위한 촬영 보조 기구의 유용성 평가)

  • Bo-Seok Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.153-159
    • /
    • 2024
  • In X-ray projection, Unskilled radiologists become skilled through fail exam. This causes the patient to be exposed to unnecessary radiation. In this study, pre-position unskilled radiologic technologist presented ways to improve clinical proficiency. presented a skull lateral x-ray projection practice method using visual, spatial, and assistive devices. In addition, the accuracy and usefulness of the use of assistive devices were evaluated. When X-ray images were taken based on learning, the rotational spacing, which indicates image distortion, was 7.85 ± 1.45 mm and the tiliting spacing was 4.84 ± 0.5 mm. When practicing using visual aids, the rotational spacing is 4.4 ± 0.76 mm and the inclination spacing is 3.01 ± 0.87 mm. using a spatial compensation device, the rotational spacing is 5.2 ± 0.69 mm and the tiliting spacing is 3.33 ± 0.61 mm. Skull lateral X-ray Image distortion caused by empirical photography practice decreased by 5.4%, but image distortion caused by tilting increased by 1.2%. When practicing using a visual assistive devices, the degree of rotational spacing by 40.1% and the tiliting spacing decreased by 30.7% compared to the empirical x-ray exposure practice. When using spatial assistive devices, the rotation interval was reduced by 41.7% and the tilting interval by 23.7% compared to conventional empirical x-ray exposure practice. Therefore, if an unskilled radiologist practices using visual and spatial aids,the accuracy will be improved in skull lateral x-ray projection.

Pile and adjacent ground behaviors depending on horizontal offset between pile and tunnel subjected to horizontally loaded single pile (수평하중을 받는 단일 말뚝 하부 터널굴착 시 말뚝-터널 수평이격거리에 따른 말뚝 및 인접 지반 거동)

  • Ahn, Ho-Yeon;Oh, Dong-Wook;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.685-703
    • /
    • 2017
  • Recently, as the number of high-rise building and earthquake occurrence are increasing, it is more important to consider horizontal load such as wind and seismic loads, earth pressure, for the pile foundation. Also, development of underground space in urban areas is more demanded to meet various problem induced by growing population. Many studies on pile subjected to horizontal load have been conducted by many researchers. However, research regarding interactive behavior on pile subjected to horizontal load with tunnel are rare, so far. In this study, therefore, study on the behaviors of ground and horizontal and vertical loads applied to single pile was carried out using laboratory model test and numerical analysis. The pile axial force and ground deformation were investigated according to offset between pile and tunnel (0.0D, 1.0D, 2.0D: D = tunnel diameter). At the same time, close range photogrammetry was used to measure displacement of underground due to tunnelling during laboratory model test. The results from numerical analysis were compared to that from laboratory model test.

A study on the optimum range of reinforcement in tunneling adjacent to structures (구조물 근접 터널시공시 최적의 보강범위에 관한 연구)

  • Lee, Hong-Sung;Kim, Dae-Young;Chun, Byung-Sik;Jung, Hyuk-Sang
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.2
    • /
    • pp.199-211
    • /
    • 2009
  • Development of underground space is actively performed globally for better life in the surface, and the scale of the space is increasing. Extreme care should be taken in the construction of the underground space in urban areas in order to avoid damage of adjacent structures and interference with existing underground space. In case of shallow tunnels, reinforcement of ground and structures is necessary to minimize the damage to structures due to excavation but any standard for optimum range of the reinforcement has not been established yet. In this paper, a series of numerical analyses have been performed for a 20 m diameter tunnel excavated underneath a structure to investigate the degree of damage of the structure according to vertical and horizontal spacing between the tunnel and structure. In addition to that, optimum range of reinforcement is presented for each case where reinforcement is required. It has been observed that the reinforcement is necessary for the ground condition adapted in the analyses as follows: (1) if horizontal spacing ($S_{H}$) approaches to 0D (D: equivalent diameter of tunnel) for vertical spacing (Sv) of 0.5D, and (2) if tunnel exists underneath the structure for vertical spacing (Sv) of 0.75D. The reinforcement is not necessary for Sv of 10 regardless of $S_{H}$. It also has been obtained that the optimum ranges of the reinforcement around structure foundation are 7 m in depth and whole width of the structure and 5 m beyond tunnel sidewall. These reinforcememt ranges have been confirmed to be enough for stability of the structure if types of reinforcement method is appropriately selected.

Testing Spatial Autocorrelation of Burn Severity (산불 피해강도의 공간 자기상관성 검증에 관한 연구)

  • Lee, Sang-Woo;Won, Myoung-Soo;Lee, Hyun-Joo
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.2
    • /
    • pp.203-212
    • /
    • 2012
  • This study aims to test presence of spatial autocorrelation of burn severity in Uljin and Youngduk areas burned in 2011. SPOT satellite images were used to compute the NDVI representing burn severity, and NDVI values were sampled for 5,000 randomly dispersed points for each site. Spatial autocorrelations of sampled NDVI values were analyzed with Moran's I and Variogram models. Moran's I values of burn severity in Uljin and Youngduk areas were 0.7745 and 0.7968, respectively, indicating presence of strong spatial autocorrelations. On the basis of Variogram and changes of Moran's I values by lag class, ideal sampling distance were proposed, which were 566-2,151 m for Uljin and 272-402 m for Youngduk. It was recommended to apply these ranges of sampling distance in flexible corresponding to Anisotropic characteristics of burned areas.

Evaluation of Separation Distance from the Temporary Storage Facility for Decontamination Waste to Ensure Public Radiological Safety after Fukushima Nuclear Power Plant Accident (후쿠시마 원전 사고 이후 일반인의 방사선학적 안전성 확보를 위한 제염폐기물 임시저장시설 이격거리 평가)

  • Kim, Min Jun;Go, A Ra;Kim, Kwang Pyo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 2016
  • The object of this study was to evaluate the separation distance from a temporary storage facility satisfying the dose criteria. The calculation of ambient dose rates took into account cover soil thickness, facility size, and facility type by using MCNPX code. Shielding effects of cover soil were 68.9%, 96.9% and 99.7% at 10 cm, 30 cm and 50 cm respectively. The on-ground type of storage facility had the highest ambient dose rate, followed by the semi-ground type and the underground type. The ambient dose rate did not vary with facility size (except $5{\times}5{\times}2m\;size$) due to the self-shielding of decontamination waste in temporary storage. The separation distances without cover soil for a $50{\times}50{\times}2m\;size$ facility were evaluated as 14 m (minimum radioactivity concentration), 33 m (most probably radioactivity concentration), and 57 m (maximum radioactivity concentration) for on-ground storage type, 9 m, 24 m, and 45 m for semi-underground storage type, and 6 m, 16 m, and 31 m for underground storage type.

Effect of abrasive waterjet parameters on rock removal (연마재 워터젯 변수가 암석제거에 미치는 영향)

  • Oh, Tae-Min;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.4
    • /
    • pp.421-435
    • /
    • 2012
  • Rock excavation (removal) tests are performed with effective parameters using an abrasive waterjet. For verification of the field rock excavation capabilities, the removal performance and level of efficiency are analyzed for hard granite rock in terms of the water pressure, exposure time of the jet, and the standoff distance. In particular, experimental tests are performed with a long standoff distance required condition in the real excavation field. The rock removal performance level changes according to the rock properties. In this study, various rock specimens are used and P-wave velocities are measured in order to determine the correlation between the removal performance and the P-wave velocity. As a result of the experimental study, the effect of waterjet parameters on rock removal is analyzed.

Influence of limestone cavity on tunnel stability (석회암 공동이 터널의 안정에 미치는 영향)

  • Jin, Seong-Kyu;Yang, Moon-Sang;Choi, Deog-Chan;Park, Kwang-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.2
    • /
    • pp.113-121
    • /
    • 2002
  • This study is focused on establishing influence zone caused by tunnelling in limestone site. Therefore, the numerical analysis using the FLAC2D was performed considering various locations and magnitudes of cavities. To reduce the stress concentration, the shape of cavities was designed to ellipse. This parametric study reveals that the cavities located at crown part and edge part of tunnel greatly have influenced on stability of tunnel. The effect of distance between tunnel and cavity which is larger than 1-0D (Tunnel diameter) dose not directly related to stability of tunnel, but the nearer a cavity location was, the larger displacement and stress of reinforcement occured within 0.25D.

  • PDF