• Title/Summary/Keyword: 의치상레진

Search Result 5, Processing Time 0.015 seconds

Effect of surface treatment on shear bond strength between artificial resin teeth and 3D printing denture base resin (인공치의 표면처리가 3D 프린팅 의치상레진과의 전단결합강도에 미치는 영향)

  • Choi, Jeehye;Lee, Younghoo;Hong, Seoung-jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.300-305
    • /
    • 2020
  • Purpose: The purpose of this study is to compare the shear bond strength of 3D printing denture base resin according to surface treatment of artificial teeth. Materials and methods: 3D printing denture base resin was fabricated as specimens using 3D printer. The experimental group divided the surface treatment of artificial teeth into five groups according to the application of sandblasting and primer (n=10). Shear bond strengths between denture base and artificial teeth were measured by universal testing machine. All measurements were analyzed by one-way ANOVA and Turkey test (α=.05). Fracture mode of each specimen was analyzed. Microscopic evaluation was conducted by using a scanning electron microscope. Results: Unsurfaced treated group represented the lowest value. The primer groups had significantly higher result values (P<.05). Most specimens of the primer groups had cohesive failure. Conclusion: In 3D printing denture base resin group, mechanical and chemical surface treatment of artificial teeth has increased the shear bond strength. Therefore, if dentures are produced using 3D printing, proper mechanical and chemical treatment of artificial teeth is necessary for adhesion of dentures and artificial teeth.

The build angle of 3D printing denture base resin on candida albicans adhesion. (의치상레진의 3D 프린팅 출력 각도가 Candida albicans의 부착에 미치는 영향)

  • Park, Su-Jung;Song, Young-Gyun
    • The Journal of the Korean dental association
    • /
    • v.58 no.1
    • /
    • pp.19-26
    • /
    • 2019
  • Purpose: The purpose of this study is to compare the adhesion of Candida albicans according to build angle in 3D printing denture base resin. Methods: The 3D printing was performed by setting the build angle of the disk type specimen designed by CAD program at 0 degree, 30 degrees, 60 degrees, and 90 degrees. Surface roughness was measured using a non-contact 3D microsurface profiler. The specimens were incubated in Candida albicans suspension for 24 hours. The attached Candida albicans were detached by cell scraper. The suspension of detached C. albicans was serially diluted and plated on Trypticase soy broth. After 48 hours of incubation, total colony forming unit was counted. Results: There was no significant difference in surface roughness(Sa) between the test groups, but the interlayer boundary was observed. There was no statistically significant difference in total colony forming units of Candida albicans between the test groups. Conclusion: There was no difference in the average surface roughness and adhesion of Candida albicans between the specimens. It is considered that the setting of the build angle should be set considering the accuracy or strength rather than the roughness of the surface.

  • PDF

THE EFFECT OF FERMENTED FOODS ON THE COLOR AND HARDNESS CHANGE OF DENTURE BASE ACRYLIC RESINS (발효음식이 의치상레진의 색상 및 표면경도 변화에 미치는 영향)

  • Jeon, Yeol-Mae;Lim, Heon-Song;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.344-355
    • /
    • 2004
  • Statement of problem: For a long time, many of denture base acrylic resins have been used for edentulous and partial edentulous patients because of easy manipulation and good mechanical properties, but its esthetic aspect has not been commented enough. Denture base acrylic resins also has caused esthetic problems due to discoloration or staining as in esthetic restoration. Many researches and reports have treated the problems and accomplished esthetic improvement. But these researches and reports dealt with general food colors or beverages, not with fermented foods. Purpose: This study is designed to assess what fermented foods, such as soy sauce, gochujang, and toenjang that many of Koreans have taken in, influence on the color and hardness variation of denture base acrylic resins. Materials and methods: For the procedure, twelve disks per 4 denture base acrylic resins were fabricated with a thickness of 2mm and 16mm in diameter. Each seven specimen were measured for discoloration with spectrophotometer, while the others, five specimen, for surface hardness change with Barcol hardness tester, over time. Each 12 specimen were immersed into the 4 beakers of fermented foods(soy sauces, gochujangs, toenjangs, deionized water), and $L^{*},a^{*}$, and $b^*$ values were measured for the color difference$({\Delta}E^*)$, on the 1st, 7th, and 28th day with spectrophotometer, with the measurement of surface hardness change. Each data observed was processed statistically. Results: The findings are as follows; Discoloration 1. All of denture base resins was not influenced by the kind of fermented foods, except for $QC20^{(R)}$ 2. Soy sauce and red pepper paste caused more change for denture base resins than deionized water and soy bean paste, except for Perform$^{(R)}$ 3. Most significant change was shown in Lucitone 199$^{(R)}$, whereas Perform$^{(R)}$ results in the least change for all immersed solution, with no statistical significance. Hardness change 1. Barcol hardness values in deposited specimens have been changed low degree, but with significant statistical change according to the kind of food and duration. 2. Lucitone$^{(R)}$ 199 as significantly lower Barcol hardness value than others do. Conclusion: Based on the above results, it suggests that the habitual intake of fermented foods is not helpful for the color stability of denture base acrylic resins because Soy sauce and red pepper paste mainly caused discoloration and surface hardness change. Particularly $Lucitone199^{(R)}$ shows specific discoloration and low surface hardness values. Therefore, it is recommended giving caution patients with denture of $Lucitone199^{(R)}$ especially against the habitual intake of fermented foods like soy sauce and red pepper paste.

A STUDY ON THE BOND STRENGH OF 4-META ACRYLIC RESIN DENTURE BASE TO COBALT-CHROMIUM ALLOYS (4-META의치상레진과 Cobalt-Chromium계 합금의 접착강도에 관한 연구)

  • Sung, Moo Gyung;Kim, Kwang Nam;Chang, Ik Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.29-51
    • /
    • 1990
  • This study was designed to compre the tensile bond strength of 4-META containging denture base resin to Co-Cr alloys after various surface treatments. Especially the surface treatment of sandblasting the mental with aluminum oxide and treating in oxidizing solution composed of 3% aqueous sulfuric acid with 1% potassium manganate were compared. Effect of surface roughness on bonding was measured after sandblasting with 50um, 300um aluminun oxide and polishing with emery pater. Also the effects of wax and wax solvent on bonding were observed. According to the type of polymerization process, heat-cured Meta-Dent resin and autopolymerizing Meta-Fast resin were used. For some specimnens, the tensile bond strength were measured agter three pre-conditions : 1day after bonding, immersed in water at $75^{\circ}C{\pm}3^{\circ}C$ for 4weeks, under normal ambient condition for 4weeks. The following results were obtained from this study : 1. The bond strengths of resins containing 4-META were significantly higher than those of conventional denture base resins(p<0.05). 2. Autopolymerizing Meta-Fast resin had higher bond strength than heat-cured Meta-Dent, resin(p<0.05). 3. The bond strengths of Biosil and Nobilium to 4-META containging resins were not significally different(p>0.05). 4. Stable adhesion can be achieved when mechanically roughen the metal surface by snadblasting with $50{\mu}m$ aluminum oxide than treating in an oxidizing soluing with potassium manganate(p<0.05). 5. Once the metal surface is contaminated with wax, the bond srtength decreased greatly in spite of wax wash with boiling water. But the bond strength recovered significantly with the use of wax solvent 6. Meta-Dent resin had higher bond strength when roughen the metal surface with $50{\mu}m$ aluminum oxide than with $300{\mu}m$ aluminum oxide(p<0.05). In case of Meta-Fast, resin, the use of $300{\mu}m$aluminum oxide was a little advantageous of bonding, but was statistically insignificant(p>0.05).

  • PDF