• Title/Summary/Keyword: 의료 질

Search Result 1,476, Processing Time 0.03 seconds

The Correction Effect of Motion Artifacts in PET/CT Image using System (PET/CT 검사 시 움직임 보정 기법의 유용성 평가)

  • Yeong-Hak Jo;Se-Jong Yoo;Seok-Hwan Bae;Jong-Ryul Seon;Seong-Ho Kim;Won-Jeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2024
  • In this study, an AI-based algorithm was developed to prevent image quality deterioration and reading errors due to patient movement in PET/CT examinations that use radioisotopes in medical institutions to test cancer and other diseases. Using the Mothion Free software developed using, we checked the degree of correction of movement due to breathing, evaluated its usefulness, and conducted a study for clinical application. The experimental method was to use an RPM Phantom to inject the radioisotope 18F-FDG into a vacuum vial and a sphere of a NEMA IEC body Phantom of different sizes, and to produce images by directing the movement of the radioisotope into a moving lesion during respiration. The vacuum vial had different degrees of movement at different positions, and the spheres of the NEMA IEC body Phantom of different sizes produced different sizes of lesions. Through the acquired images, the lesion volume, maximum SUV, and average SUV were each measured to quantitatively evaluate the degree of motion correction by Motion Free. The average SUV of vacuum vial A, with a large degree of movement, was reduced by 23.36 %, and the error rate of vacuum vial B, with a small degree of movement, was reduced by 29.3 %. The average SUV error rate at the sphere 37mm and 22mm of the NEMA IEC body Phantom was reduced by 29.3 % and 26.51 %, respectively. The average error rate of the four measurements from which the error rate was calculated decreased by 30.03 %, indicating a more accurate average SUV value. In this study, only two-dimensional movements could be produced, so in order to obtain more accurate data, a Phantom that can embody the actual breathing movement of the human body was used, and if the diversity of the range of movement was configured, a more accurate evaluation of usability could be made.

Community Residents' Knowledge, Attitude, and Needs for Hospice Care (일부 지역주민들의 호스피스에 대한 인지와 태도 및 간호요구 조사)

  • Ro, You-Ja;Han, Sung-Suk;Ahn, Sung-Hee;Yong, Jin-Sun
    • Journal of Hospice and Palliative Care
    • /
    • v.2 no.1
    • /
    • pp.23-35
    • /
    • 1999
  • Purpose : The hospice movement began about 30 years ago in Korea. However, basic studies have seldom been conducted about the general public's knowledge concerning hospice care and their needs for it. The purpose of this study was to investigate the general public's knowledge of and attitude toward hospice, and their needs for hospice care, and to analyze the needs for hospice care in relation to their knowledge and attitude in residents from a specific community. Methods : The survey was conducted with 924 people randomly selected from a district in Seoul. The data were collected through a self-reporting questionnaire constructed by the authors. With 30 items given in the questionnaire, the level of hospice needs showed Cronbach's alpha .89 in a pilot study and .92 in this study and the items were classified into four areas by a factor analysis. The data collected were analyzed by means of t-test and ANOVA. Results : 1) The average age of the respondents was 38. The majority of the respondents were well-educated. 2) Regarding awareness of hospice care, 54%(501 people) indicated they have heard of hospice. About 74% thought that people should be able to prepare for death in advance. About 83% wanted to be informed when they have life threatening illnesses such as terminal cancer. Also, about 63% responded that patients with terminal diseases should be provided with physical, spiritual, and psychological care for minimizing pain and peaceful death. Regarding the attitude toward hospice care, 74% responded that they would use hospice care if needed. The number of the respondents who preferred home visitation by the hospice team to care for the terminally ill ranked first with 34%. Concerning needs for hospice care : 1) By needs area, physical need showed highest mean(M=4.37), followed by social need(M=3.96), emotional need(M=3.87), and the spiritual need(M=3.79). The overall need level showed the mean value of 4.00 which reflects a considerable need for hospice care. 2) By demographic characteristics, people age over 50, the married, and the unemployed indicated higher level of needs for hospice care. Women showed higher level of needs than did men, and Catholics demonstrated higher level of needs than believers of other religion(P<0.0001). 3) As for the knowledge of and attitude toward hospice rare, the level of hospice care needs was significantly higher in the following groups: those who have heard of hospice, those who are aware of death preparation, those who want information on terminal diseases, those who want to use every method to sustain life, and those who are aware of hospice needs(P<0.001). Conclusion : It is assumed that the findings of this study on the knowledge, attitude, and needs for hospice care in the public can contribute to planning a successful hospice care program. Furthermore, the findings of this study will serve as useful data for the promotion of home hospice care to improve the quality of life of community residents, and contribute to the development of hospice care as a whole.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

The Developmental Effects of Radiation on ICR Mouse Embryos in Preimplantation Stage (착상전기(着床前期)에 있어서 ICR Mouse의 태아(胎兒)에 대한 방사선(放射線) 개체(個體) Level 영향(影響)의 연구(硏究))

  • Gu, Yeun-Hwa
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.273-284
    • /
    • 1996
  • Embryos and fetuses are more sensitive to various environmental agents than are adults or children. The biological effects such as intrauterine death and malformation are closely connected with prenatal exposure very various agents. The sensitivity of these embryonic/fetal effects depends on the stage of pregnancy. From the viewpoint of fetal development, embryonic and fetal stages can be divided into three stages : Preimplantation, organogenetic and fetal. Each stage corresponds to 0 to 4.5days, 4.5 to 13.5days, and 13.5days of gestation in mice, respectively. Many studies on the biologcal effects of mice irradiated by ${\gamma}-rays$ at various stages during organogenesis and fetal period have been performed. Based on these results, the dose-effect and dose-response relationships in malformations, intrauterine death, or retardation of the physical growth have been practically modeled by the ICRP(International Commission on Radiological Protection) and other international bodies for radiation protection. Many experimental studies on mice have made it clear that mice embryos in the preimplantation period have a higher sensitivity to radiation for lethal effects than the embryos/fetuses on other prenatal periods. However, no eratogenic effects of radiation at preimplantation stages of mice have been described in many textbooks. It has been believed that 'all or none action results' for radiation of mice during the preimplantation period were applied. The teratogenic and lethal effects during the preimplantation stage are one of the most important problems from the viewpoint of radiological protection, since the preimplantation stage is the period when the pregnancy itself is not noticed by a pregnant woman. There are many physical or chemical agents which affect embryos/fetuses in the environment. It is assumed that each agents indirectly effects a human. Then, a safety criterion on each agent is determined independently. The pregnant ICR mice on 2, 48, 72 or 96 hours post-conception (hpc), at which are preimplantation stage of embryos, were irradiated whole body Cesium-gamma radiation at doses of 0.1, 0.25, 0.5, 1.5, and 2.5 Gy with dose rate of 0.2 Gy/min. In the embryos from the fetuses from the mice irradiated at various period in preimplantation, embryonic/fetal mortalities, incidence of external gross malformation, fetal body weight and sex ratio were observed at day 18 of gestation. The sensitivity of embryonic mortalities in the mice irradiated at the stage of preimplantation were higher than those in the mice irradiated at the stage of organogenesis. And the more sensitive periods of preimplantation stage for embryonic death were 2 and 48 hpc, at which embryos were one cell and 4 to 7 cell stage, respectively. Many types of the external gross malformations such as exencephaly, cleft palate and anophthalmia were observed in the fetuses from the mice irradiated at 2, 72 and 96 hpc. However, no malformations were observed in the mice irradiated at 48 hpc, at which stage the embryos were about 6 cell stage precompacted embryos. So far, it is believed that the embryos on preimplantation stage are not susceptible to teratogens such as radiation and chemical agents. In this study, the sensitivity for external malformations in the fetuses from the mice irradiated at preimplantation were higher than those in the fetuses on stage of organogenesis.

  • PDF

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

Long-Term Results of 2-Dimensional Radiation Therapy in Patients with Nasopharyngeal Cancer (이차원방사선치료를 시행한 코인두암 환자의 장기 추적 결과 및 예후인자 분석)

  • Lee, Nam-Kwon;Park, Young-Je;Yang, Dae-Sik;Yoon, Won-Sup;Lee, Suk;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.193-204
    • /
    • 2010
  • Purpose: To analyze the treatment outcomes, complications, prognostic factors after a long-term follow-up of patients with nasopharyngeal carcinoma treated with radiation therapy (RT) alone or concurrent chemoradiation therapy (CCRT). Materials and Methods: Between December 1981 and December 2006, 190 eligible patients with non-metastatic nasopharyngeal carcinoma were treated at our department with a curative intent. Of these patients, 103 were treated with RT alone and 87 patients received CCRT. The median age was 49 years (range, 8~78 years). The distributions of clinical stage according to the AJCC 6th edition included I: 7 (3.6%), IIA: 8 (4.2%), IIB: 33 (17.4%), III: 82 (43.2%), IVA: 31 (16.3%), IVB: 29 (15.3%). The accumulated radiation doses to the primary tumor ranged from 66.6~87.0 Gy (median, 72 Gy). Treatment outcomes and prognostic factors were retrospectively analyzed. Acute and late toxicities were assessed using the RTOG criteria. Results: A total of 96.8% (184/190) of patients completed the planned treatment. With a mean follow-up of 73 months (range, 2~278 months; median, 52 months), 93 (48.9%) patients had relapses that were local 44 (23.2%), nodal 13 (6.8%), or distant 49 (25.8%). The 5- and 10-year overall survival (OS), disease-free survival (DFS), and disease-specific survival (DSS) rates were 55.6% and 44.5%, 54.8% and 51.3%, in addition to 65.3% and 57.4%, respectively. Multivariate analyses revealed that CCRT, age, gender, and stage were significant prognostic factors for OS. The CCRT and gender were independent prognostic factors for both DFS and DSS. There was no grade 4 or 5 acute toxicity, but grade 3 mucositis and hematologic toxicity were present in 42 patients (22.1%) and 18 patients (9.5%), respectively. During follow-up, grade 3 hearing loss in 9 patients and trismus in 6 patients were reported. Conclusion: The results of our study were in accordance with findings of previous studies and we confirmed that CCRT, low stage, female gender, and young age were related to improvement in OS. However, there are limitations in the locoregional control that can be achieved by CCRT with 20 conventional radiation therapy. This observation has led to further studies on clarifying the efficacy of concurrent chemotherapy by intensity modulated radiation therapy.