• Title/Summary/Keyword: 의료초음파

Search Result 244, Processing Time 0.029 seconds

A Modified SaA Architecture for the Implementation of a Multiplierless Programmable FIR Filter for Medical Ultrasound Signal Processing (곱셈기가 제거된 의료 초음파 신호처리용 프로그래머블 FIR 필터 구현을 위한 수정된 SaA 구조)

  • Han, Ho-San;Song, Jae-Hee;Kim, Hak-Hyun;Goh, Bang-Young;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.423-428
    • /
    • 2007
  • Programmable FIR filters are used in various signal processing tasks in medical ultrasound imaging, which are one of the major factors increasing hardware complexity. A widely used method to reduce the hardware complexity of a programmable FIR filter is to encode the filter coefficients in the canonic signed digit (CSD) format to minimize the number of nonzero digits (NZD) so that the multipliers for each filter coefficients can be replaced with fixed shifters and programmable multiplexers (PM). In this paper, a new structure for programmable FIR filters with a improved frequency response and a reduced hardware complexity compared to the conventional shift-and-add architecture using PM is proposed for implementing a very small portable ultrasound scanner. The CSD codes are optimized such that there exists at least one common nonzero digit between neighboring coefficients. Such common digits are then implemented with the same shifters. For comparison, synthesisable VHDL models for programmable FIR filters are developed based on the proposed and the conventional architectures. When these filters have the same hardware complexity, pass-band ana stop-band ripples of the proposed filter are lower than those of the conventional filter by about $0.01{\sim}0.19dB$ and by about $5{\sim}10dB$, respectively. For the same filter performance, the hardware complexity of the proposed architecture is reduced by more than 20% compare to the conventional SaA architecture.

Radiologic Analysis of Tuberculous Spondylitis (결핵성 척추염의 방사선학적 분석)

  • Hwang, Mi-Soo;Kim, Sun-Yong
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.95-102
    • /
    • 1986
  • Among the skeletal tuberculosis, tuberculous spondylitis is high incidence and curable disease, if early diagnosis and treatment are possible. We reviewed clinical manifestations and radiologic analysis of 30 cases tuberculous spondylitis from May 1983 to Sept. 1986, at Yeungnam medical center, Yeungnam University. The results were follows : 1. The frequent involve sites were thoracolumbar vertebra. 2. The continuous lesion is 86.7% of the all cases. 3. The most common type was intervertebral type, and lytic and sclerotic lesion were same incidence. 4. Paravertebral abscess, kyphosis and disc space narrowing were demonstrated more than 80.0% of the cases. 5. Computed tomography was more accurate diagnostic method rather than conventional plain study to evaluation of extent of lesion, involvement of spinal canal and cord, and size and location of paravertebral abscess. And CT guided abscess drainage procedure was helpful to diagnosis and treatment. 6. Ultrasonography was helpful to differential diagnosis between paravertebral abscess and other solid mass, and useful to follow up study of paravertebral abscess after treatment.

  • PDF

Modified Piezoelectric Ceramics for Portable Ultrasonic Medical Probe Application (휴대용 의료 초음파 프로브 적용을 위한 압전체 제조 및 특성)

  • Kang, Dong Heon;Chae, Mi Na;Hong, Se Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.8
    • /
    • pp.483-488
    • /
    • 2016
  • Ultrasound imaging by using piezoelectric materials, such as lead zirconium titanate (PZT) has been one of the most preferred modes of imaging in the medical field due to its simple, low cost and non-ionizing radiation in comparison to other imaging techniques. Recently, the market demand for portable ultrasound is becoming larger with applications in developing countries, disaster area, military, and emergency purposes. However, most of ultrasound probes used is bulky and high power consumable, so unsuitable for such applications. In this study, the 3 layered ceramic specimen consisted of 128 pitches of $420{\mu}m$ in width and $450{\mu}m$ in thickness were prepared by using the Ti-rich PZT compositions co-fired at $1,050^{\circ}C$. Their electrical and ultrasound pulse-echo properties were investigated and compared to the single layer specimen. The 3 layered ultrasound probe showed 1.584 V of Vp-p, which is 3.2 times higher than single layered one, implying that it would allow effectively such a portable ultrasound probe system. The result were discussed in terms of higher capacitance, lower impedance and higher dielectric coefficient of the 3 layered ultrasound probe.

Dielectric and Piezoelectric Properties of Low Temperature Sintering PZN-PZT Ceramics with a variation of $Li_2CO_3$ Addition ($Li_2CO_3$ 첨가에 따른 저온소결 PZN-PZT 세라믹스의 유전 및 압전특성)

  • Lee, Yu-Hyong;Lee, Sang-Ho;Yoo, Ju-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.307-307
    • /
    • 2007
  • 압전액츄에이터 및 초음파진동자는 전자제품의 소형화 및 경량화, 의료기기, 모바일기기 및 소형로붓의 발전에 힘입어 그 활용범위가 넓게 확장되고 있다. 1960년 Smolenski등에 의해 $A(B_1,B_2)O_3$형 복합 페로브스카이트 구조를 갖는 강유전성 세라믹스에 대한 연구가 시작된 이래 $Pb(Co,Nb)O_3-Pb(Zr,Ti)O_3$, $Pb(Zn,Nb)O_3-Pb(Zr,Ti)O_3$, $Pb(Mg,Nb)O_3-Pb(Zr,Ti)O_3$ 등 3성분계 세라믹스의 유전, 압전 및 강유전 특성에 대한 많은 연구가 진행되어 왔다. 그러나 압전성이 우수한 세라믹스들은 Pb가 포함되어 있기 때문에 $1000^{\circ}C$ 이상에서 PbO가 급격하게 휘발되는 성질에 따라서 조성의 변동이 생겨 재현성이 어려우며 이를 방지하기 위하여 과잉 PbO를 첨가시키기 때문에 환경오염뿐만 아니라, 경제적인 측면에서도 많은 문제점을 가지고 있다. 소결조제를 이용한 산화물 첨가법은 PbO의 휘발을 억제하는 저온소결 방법중 가장 효과적인 방법으로 알려져 있다. 따라서, 본 연구에서는 적층형 압전액츄에이터로 사용하기위한 저온소결 압전세라믹스를 개발하기 위하여 PZN-PZT세라믹스에 $Li_2CO_3$, $Bi_2O_3$, CuO 를 소결조제로 사용하여 $Li_2CO_3$의 첨가량 변화에 따른 압전 및 유전 특성을 관찰하였다.

  • PDF

Stener-Like Lesions in the Metacarpophalangeal Joint of the Fingers (다른 수지의 중수수지 관절에서의 Stener 유사 병변)

  • Lee, Sanglim;Jung, Eui Yub;Lee, Jihae;Jeon, Suk Ha
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.547-551
    • /
    • 2018
  • Three Stener-like lesions of the metacarpophalangeal joint of the fingers and a rupture of the first dorsal interosseous muscle mimicking the lesion in the index finger were observed. Two cases in the little fingers had a true Stener's lesion. In one case in the index finger, the ruptured ligament was retracted and located under the intact sagittal band, which was also observed by preoperative magnetic resonance imaging (MRI). Rupture of the first dorsal interosseous muscle was misdiagnosed preoperatively as a Stener's lesion in the index finger by ultrasonography. MRI should be an essential differential diagnostic exam for collateral ligament ruptures of the metacarpophalangeal joint of the fingers.

Automatic Pill Dispenser Based on Arduino (아두이노 기반의 자동 알약 배급기)

  • Kim, Ji-Min;Kim, Min-Ji;Lee, Su-Jin;Kim, Sung-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.854-856
    • /
    • 2016
  • Nowadays, the interests about medical service and health concerting, in other words "Healthcare",are increasing. For healthcare, one of the most convenient and populated methods is taking nutritional supplements like vitamin everyday. According to social currency, we realize ' Automatic Pill Dispenser (APD)' in order to make the storage of pills easy and to help people take pills steadily periodically. First, the APD alerts at the time when the user sets. To prevent polluting pills, if the ultrasonic sensor recognizes user hands, and then after the APD distributes pills through activating the motor. If there are more the APDs, for example, hospitals can manage manpower more efficiently. Furthermore, If it is recorded which and how much pills are distributed automatically, It can be expected that people can take the pills more efficiently and healthfully.

  • PDF

A development of a multimodal patch-type probe for measuring blood flow and oxygen saturation in carotid artery (경동맥 혈류 속도 및 산소 포화도 측정을 위한 다중모드 패치형 프로브 개발)

  • Youn, Sangyeon;Lee, Kijoon;Kim, Jae Gwan;Hwang, Jae Youn
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2019
  • To protect the patient's internal organs when a patient with cardiovascular disease occurs, it is important to reduce the elapsed time by providing emergency medical services. Decisions for conducting cardiopulmonary resuscitation are mainly made using the carotid palpation method, which directs the pulse of the carotid artery, which can diagnose the patient's condition according to one's own subject and cause cerebral blood flow to be blocked by excessive pressure in the carotid due to the weaken cardiopulmonary function. In this study, we developed a multimodal patch-type probe based on multi-channel ultrasound Doppler pairs and oxygen saturation measurement modules which can monitor cardiopulmonary functions. From the in-vivo experiments, the developed probe can be utilized as a novel tool that can increase the survival rate of cardiovascular disease patients by objectively monitoring the cardiopulmonary function of the patient quantitatively and promptly in an emergency situation.

Signal-to-noise Ratio in Time- and Frequency-domain Photoacoustic Measurements by Different Frequency Filtering (주파수 필터링 함수에 따른 시간 및 주파수 영역 광음향 측정에 대한 신호 대 잡음비 분석)

  • Kang, DongYel
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.2
    • /
    • pp.48-58
    • /
    • 2019
  • We investigate the signal-to-noise ratios (SNRs) of time-domain (i.e. pulsed illumination) and frequency-domain (i.e. chirped illumination) photoacoustic signals measured by a spherically focused ultrasound transducer for spherical absorbers. The simulation results show that the time-domain photoacoustic SNR is higher than that of frequency-domain photoacoustic signals, as reported in the previous literature. We understand the reason for this SNR gap between the two measurement modes by analyzing photoacoustic-signal spectra, considering the incident beam energy controlled by the maximum permissible exposure. As the result of this approach, we find that filtering off the DC term in the chirped signal's spectrum improves frequency-domain photoacoustic SNRs by up to approximately 5 dB. In particular, it is observed that photoacoustic SNRs are highly sensitive to an upper-frequency value of frequency filtering functions, and the optimal upper-frequency values maximizing the SNR are different in time- and frequency-domain photoacoustic measurements.

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

Thyroid Radiology Practice: Diagnosis and Interventional Treatment of Patients with Thyroid Nodules (갑상선 영상의학 진료: 갑상선 결절 환자의 진단과 중재적 치료)

  • Jung Hwan Baek;Dong Gyu Na
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.530-548
    • /
    • 2020
  • Thyroid radiology practice is a medical practice in which thyroid diseases are diagnosed using imaging modality and treated by imaging-based interventional techniques, and the primary care target is thyroid nodular disease. Diagnosis of thyroid nodules is primarily done by ultrasound imaging and biopsy; thyroid nodules can be treated by non-surgical interventional treatment and thyroidectomy. Ethanol ablation is the first-line treatment for cystic benign nodules, and radiofrequency ablation is used for the treatment of benign solid nodules and recurrent thyroid cancers. Thyroid radiology practice has an essential clinical role in diagnosis and nonsurgical treatment of thyroid nodular diseases, and treatment should be performed based on standard care guidelines for proper patient care. In order to provide the best care to patients with thyroid nodular disease, it is desirable to treat patients in the radiology outpatient clinic. Thyroid radiology practice centered on outpatient clinic practice needs to be expanded.