• Title/Summary/Keyword: 의료영상융합

Search Result 140, Processing Time 0.024 seconds

Evaluation of Angle Dependence on Positional Radioisotope Source Detector using Monte Carlo Simulation in NDT (몬테카를로 시뮬레이션을 이용한 방사선원 위치 검출기의 각도의존성 연구)

  • Han, Moojae;Heo, Seunguk;Shin, Yohan;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.141-146
    • /
    • 2019
  • Radiation sources used in the field of industrial non-destructive pose a risk of exposure due to ageing equipment and operator carelessness. Thus, the need for a safety management system to trace the location of the source is being added. In this study, Monte Carlo Simulation was performed to analyse the angle dependence of the unit-cell comprising the line-array dosimeter for tracking the location of radiation sources. As a result, the margin of error for the top 10% of each slope was 5.90% at $0^{\circ}$, 8.08% at $30^{\circ}$, and 20.90% at $60^{\circ}$. The ratio of the total absorbed dose was 83.77% at $30^{\circ}$ and 53.36% at $60^{\circ}$ based on $0^{\circ}$(100%) and showed a tendency to decrease with increasing slope. For all gradients, the maximum number was shown at $30^{\circ}$ No. 9 pixels, and for No. 10, there was a tendency to drop 7.24 percent. This study has shown a large amount of angle dependence, and it is estimated that the proper distance between the source and line-array dosimeters should be maintained at a distance of not less than 1 cm to reduce them.

Analysis of Healthcare Convergence on Bacterial Contamination of Radiological Equipment in Emergency Rooms of General Hospitals (종합병원 응급실내의 영상의학과 장비에서의 세균 오염에 관한 보건학적 융합 분석)

  • Hong, Dong-Hee;Park, Mi-Soon
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.1
    • /
    • pp.51-59
    • /
    • 2017
  • It is to establish preliminary data about healthcare convergencr of infection control by performing a bacterial contamination test for CT scanner as well as general radiographic systems in the emergency rooms of general hospitals. The period was December 1 ~ December 31, 2015. It is detect in the emergency rooms of 7 medical facilities including 2 in Seoul, and 1 in Gyeonggi-do Province, and 2 in Jeonla-do Province, and 2 in Chungcheong-do Province. The surface contamination strains detected from CT scanner in the radiology department emergency rooms were Micrococcus species(4,5%), Stenotrophomonas maltophilia(9%), Enterococcus faecium(4.5%), Providencia stuartii(4.5), and Gram negative bacilli(4.5%). Also, the surface contamination strains detected from general radiographic system in the radiology department emergency rooms were Providencia stuartii(11%), Klebsiella pneumonia(3.5%), Stenotrophomonas maltophilia(11%), Pantoea species(11%), Acinetobacter baumannii(3.5%), Micrococcus species(3.5%), Escherichia coli(3.5%), Enterobacter species(3.5%), and Gram negative bacilli(11%). Considering that the regions of most detection were all the places closely related to patients, radiologists would have to thoroughly clean with alcohol before and after a test.

Reversible Data Hiding Technique using Encryption Technique and Spatial Encryption Technique (암호화 기법 및 공간적인 암호화 기법을 사용한 가역 데이터 은닉기법)

  • Jung, Soo-Mok
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.632-639
    • /
    • 2021
  • In this paper, we proposed a reversible data hiding technique that greatly enhances the security of confidential data by encrypting confidential data and then spatially encrypting the encrypted confidential data and hiding it in the cover image. When a result image is generated by hiding the encrypted confidential data in the cover image using a spatial encryption technique, the quality of the result image is very good, and the original cover image and the result image cannot be visually distinguished. Since the encrypted confidential data is spatially encrypted and concealed, it is not possible to know where the encrypted confidential data is concealed in the result image, and the encrypted confidential data cannot be extracted from the result image. Even if the encrypted confidential data is extracted, the original confidential data is not known because the confidential data is encrypted. Therefore, if confidential data is concealed in images using the proposed technique, the security of confidential data is greatly improved. The proposed technique can be effectively used in medical and military applications.

Analysis of Health Care Service Trends for The Older Adults Based on ICT (국내외 ICT기반 노인 건강관리 서비스 동향분석)

  • Lee, Sung-Hyun;Hong, Sung Jung;Kim, Kyung Mi
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.5
    • /
    • pp.373-383
    • /
    • 2021
  • Our society is aging rapidly. In this super-aged society, the increase in healthcare costs are considered a national problem that undermines the sustainability of social security. Various services for healthcare for the elderly have been promoted to address this. However, most of them have focused on healthcare after the outbreak of chronic diseases and lack preventive healthcare. Most of the preventive healthcare projects are only pilots. In this paper, the current status of health care services for senior citizens at home and abroad was analyzed and based on this, the limitations and improvements were analyzed to propose the establishment of IoT-based Total Silver Care Center. IoT-based Total Silver Care Center may be conveniently monitored the health status of the elderly through various sensors, medical devices, and smart bands. And based on this, it can improve the quality of nursing services through time-saving and work efficiency of nursing providers. In addition, health care interventions may be provided in a timely manner if there is a change in the health status of users. And real-time imaging systems can help overcome mental difficulties.

Requirement for Amendment of the Law on the Phrase 'Instruction of Physicians or Dentists' in Medical Service Technologist, etc Act (의료기사 등에 관한 법률에서 '의사 또는 치과의사의 지도' 문구에 대한 법률 개정 요구도)

  • Lim, Woo-Taek;Lim, Cheong-Hwan;Joo, Young-Cheol;Hong, Dong-Hee;Jung, Hong-Ryang;Kim, Eun-Hye;Yoon, Yong-Su;Jung, Young-Jin;Choi, Ji-Won
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.503-512
    • /
    • 2021
  • The purpose of this study is to check the extent to which "instruction of physician or dentist" defined in the Medical Service Technologists, etc. Act is applied in relation to radiography examination procedures for radiological technologists. In addition, it is intended to present basic data on the requirement to revise the Medical Service Technologists, etc. Act in the radiological technologist's duty area and scope of work, The subjects of this study were radiological technologists with license, and the response data were collected after sending the questionnaire link written on the online questionnaire form. The final number of respondents were 1,018, and the response rate was 6.8%. Most of the negative responses were "I have never received 'instruction' for radiologic examination by a physician or dentist, including a radiologist in a medical environment." There were a high perception that "the professionalism in radiation examination on radiological technologists are higher than that of a physician or dentist." They answered that the current continuing education has a great impact on maintaining and continuing professionalism and learning new knowledge in the radiology field. In addition, the radiological technologists provide a very high level of education in areas related to radiography procedure ethics such as patient care, patient safety, and patient privacy protection, as well as specialized fields such as radiation-related examination methods, radiography examination dose, and patient exposure dose. Radiological technologists replied that they were receiving it consistently. In conclusion, in the current medical environment, the 'instruction' of a physician or dentist cannot be seen as being realistically performed. The phrase 'instruction' of a physician or dentist as defined in the Medical Service Technologists, etc. Act is considered inappropriate in respect of the fact that the state recognizes the qualifications of the medical service technologist through a license. It is thought that revision to a new term suitable for the current medical environment is necessary.

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

Measurements of the Hepatectomy Rate and Regeneration Rate Using Deep Learning in CT Scan of Living Donors (딥러닝을 이용한 CT 영상에서 생체 공여자의 간 절제율 및 재생률 측정)

  • Sae Byeol, Mun;Young Jae, Kim;Won-Suk, Lee;Kwang Gi, Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.434-440
    • /
    • 2022
  • Liver transplantation is a critical used treatment method for patients with end-stage liver disease. The number of cases of living donor liver transplantation is increasing due to the imbalance in needs and supplies for brain-dead organ donation. As a result, the importance of the accuracy of the donor's suitability evaluation is also increasing rapidly. To measure the donor's liver volume accurately is the most important, that is absolutely necessary for the recipient's postoperative progress and the donor's safety. Therefore, we propose liver segmentation in abdominal CT images from pre-operation, POD 7, and POD 63 with a two-dimensional U-Net. In addition, we introduce an algorithm to measure the volume of the segmented liver and measure the hepatectomy rate and regeneration rate of pre-operation, POD 7, and POD 63. The performance for the learning model shows the best results in the images from pre-operation. Each dataset from pre-operation, POD 7, and POD 63 has the DSC of 94.55 ± 9.24%, 88.40 ± 18.01%, and 90.64 ± 14.35%. The mean of the measured liver volumes by trained model are 1423.44 ± 270.17 ml in pre-operation, 842.99 ± 190.95 ml in POD 7, and 1048.32 ± 201.02 ml in POD 63. The donor's hepatectomy rate is an average of 39.68 ± 13.06%, and the regeneration rate in POD 63 is an average of 14.78 ± 14.07%.

주사용 요오드화 조영제 및 MRI용 가돌리늄 조영제 유해 반응에 대한 한국 임상진료지침: 개정된 임상적 합의 및 권고안(2022년 제3판)

  • Se Won Oh;So Young Park;Hwan Seok Yong;Young Hun Choi;Min Jae Cha;Tae Bum Kim;Ji Hyang Lee;Sae Hoon Kim;Jae Hyun Lee;Gyu Young Hur;Jae Yeon Hwang;Sejoong Kim;Hyo Sang Kim;Ji Young Ryu;Miyoung Choi;Chi-Hoon Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.254-264
    • /
    • 2022
  • The Korean Society of Radiology and Medical Guidelines Committee amended the existing 2016 guidelines to publish the "Korean Clinical Practice Guidelines for Adverse Reactions to Iodide Contrast for Injection and Gadolinium Contrast for MRI: The Revised Clinical Consensus and Recommendations (2022 Third Edition)." Expert members recommended and approved by the Korean Society of Radiology, the Korean Academy of Asthma, Allergy and Clinical Immunology, and the Korean Nephrology Society participated together. According to the expert consensus or systematic literature review, the description of the autoinjector and connection line for the infection control while using contrast medium, the acute adverse reaction, and renal toxicity to iodized contrast medium were modified and added. We would like to introduce the revised contents.

A Study on Image Feature Point Extraction for Realistic Contents (실감형 콘텐츠를 위한 영상 특징점 추출 기법 연구)

  • Kim, Jin-Sung;Park, Byeong-Chan;Won, Yu-Hyeon;Kim, Young-Mo;Kim, Seok-Yoon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.07a
    • /
    • pp.385-386
    • /
    • 2018
  • 최근 실감형 미디어에 대한 관심이 증폭되고 있으며 제조, 교육, 의료, 국방 등에 분야에서 기존 산업과 융합하여 많은 연구가 진행되고 있으며 MPEG에서도 이러한 실감형 미디어 기술에 대한 자체적인 표준화가 진행 중에 있다. 하지만 실감형 미디어에 대한 제작기술과 디스플레이기술에 대한 이슈는 있으나 콘텐츠 보호에 대한 기술 연구는 활발하게 진행되지 않고 있다. 더구나 실감형 미디어가 최근 웹하드, 토렌트 등에서 불법 유출 되고 있어 이에 대응한 저작권기술연구가 필요하다. 본 논문은 MPEG 산하에서 표준화가 진행되는 실감형 미디어 지원 포맷인 OMAF 구조를 설명하고 이에 대한 기술적 특징을 활용하여 특징점으로 활용될 수 있는 이미지 영역에 대한 선택 방안을 제안한다.

  • PDF

Wearable Based User Danger Situation Discerning System (웨어러블 기반 사용자 위험상황 식별 시스템)

  • Yu, Dong-Gyun;Hwang, Jong-Sun;Kim, Han-Kil;Kim, Han-Kyung;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.792-793
    • /
    • 2016
  • Recent studies on a fusion of health care system and the information and communication technology of wearable is being developed Anytime and anywhere without being constrained to measure the biological information of the user. However existing wearable monitors the measured biological information. If the user is hard to deal with for the event of dangerous situations. In this paper, it proposes a system that identifies the status of a user to correct the problem it utilizes sensors and algorithms to measure the biological information. This enables the user will be able to respond quickly to dangerous situations. In the event of a dangerous situation, such as falling or stumbling sends an emergency alert to a designated guardian.

  • PDF