Heat and Mass Transfer Characteristics and Performance Evaluation of a Double-Tube Condenser for an Alternative Refrigerant (대체냉매의 2중관 응축기 열 및 물질전달과 성능평가)

  • 이상무;박병덕;소산번
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.468-476
    • /
    • 2002
  • This paper deals with heat and mass transfer characteristics and performance evaluation of a counter flow double-tube condenser for a multi-component refrigerant mixture. The local heat and mass transfer characteristics of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a are evaluated for a counter flow double-tube condenser cooled by water. Then, the local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, heat flux and condensation mass flux are obtained. The heat exchange performance for ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a on the total pressure drop and the heat transfer characteristics are also compared with those for R404A, R410A, R502, R22, R32, Rl23 and R134a.

Experiments on Condensation Heat Transfer and Pressure Drop in Plate Heat Exchangers with Different Chevron Angles (판형 열교환기의 세브론각에 따른 응축열전달 및 압력강하 실험)

  • 김윤호;한동혁;이규정
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1141-1148
    • /
    • 2001
  • Experiments on the condensation heat transfer and pressure drop in the brazed type plate heat exchangers are performed with refrigerants R410A/R22. To investigate the geometric effect, plate heat exchangers with the same pitch and height but different $45^{\circ},\;35^{\circ}and\;20^{\circ}$ chevron angles are used. Varying the mass flux of refrigerant (13~34 kg/$m^2$), the condensing temperatures ($20^{\circ}C\;and\;30^{\circ}C$) and the vapor quality (from 0.9 to 0.15) at the same constant heat flux ($5kW/m^2$), the condensation heat transfer coefficients and pressure drops are measured. The heat transfer coefficients decrease slightly with increasing the condensing temperature at a given mass flux in all plate heat exchangers. The pressure drop increases with increasing the mass flux and the quality and decreasing the condensing temperature and the chevron angle.

  • PDF

The Influence of Variable Thermophysical Properties for Filmwise Condensation of Superheated Vapor on a Vertical Wall (수직 벽에서 과열증기의 막응축에 대한 열물성의 영향)

  • 김경훈;성현찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.235-243
    • /
    • 2000
  • A theoretical model for laminar filmwise condensation along an isothermal vertical wall at constant pressure has been formulated on the basis of conservation laws and other fundamental physical principles. The model was applied to the prediction of the influences of variable thermophysical properties of liquid and vapor layers in the filmwise condensation of superheated vapor of Rl2, R134a, R142b and R152a. The dimensionless velocity component method was employed in the transformation of the governing equations and their boundary conditions, and the polynomial method was used for treating variable thermophysical properties of liquid and vapor. Physical quantities, such as the dimensionless thickness of the liquid layer, local heat transfer rate and mean heat transfer coefficient, were investigated for different values of the superheated temperature of the stagnant vapor far from the wall. It was found that the value of mean heat transfer coefficient of R134a was higher than other refrigerants for the change of the superheated temperature.

  • PDF

The Condensation Heat Transfer of Alternative Refrigerants for R-22 in Small Diameter Tubes (세관내 R-22 대체냉매의 응축열전달에 관한 연구)

  • Son, Chang-Hyo;Jeong, Jin-Ho;O, Jong-Taek;O, Hu-Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.2
    • /
    • pp.180-186
    • /
    • 2001
  • The condensation heat transfer coefficients of pure refrigerants R-22, R-134a, and a binary refrigerant mixture R-410A flowing in a small diameter tube were investigated. The experiment apparatus consists of a refrigerant loop and a water loop. The main components of the refrigerant loop consist of a variable-speed pump, a mass flowmeter, an evaporator, and a condenser(test section). The water loop consists of a variable-speed pump, an isothermal tank, and a flowmeter. The condenser is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The test section consists of smooth, horizontal copper tube of 3.38mm outer diameter and 1.77mm inner diameter. The length of test section is 1220mm. The refrigerant mass fluxes varied from 450 to 1050kg/(㎡$.$s) and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main results were summarized as follows ; in the case of single-phase flow, the heat transfer coefficients increase with increasing mass flux. The heat transfer coefficient of R-410A was higher than that of R-22 and R-134a, and the heat transfer for small diameter tubes were about 20% to 27% higher than those predicted by Gnielinski. In the case of two-phase flow, the heat transfer coefficients also increase with increasing mass flux and quality. The condensation heat transfer coefficient of R-410A was slightly higher than that of R-22 and R-134a. Most of correlations proposed in the large diameter tube showed significant deviations with experimental data except for the ranges of low quality and low mass flux.

Themodynamic Characteristics of a Two-Stage Binary Absorption Cycle (2단(段) 2원(元) 흡수(吸收)사이클의 특성(特性)에 관(關)한 연구(硏究))

  • Lee, Y.H.;Rie, D.H.;Kashiwagi, T.;Seo, J.Y.
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.29-38
    • /
    • 1995
  • This paper concerns the study of a two-stage binary absorption cycle employing the refrigerant/absorbent combinations of $LiBr/H_2O$ and $NH_3/H_2O$. This cycle consists of coupling two single-effect absorption cycles so that the first stage absorber and condenser produces heating water to evaporate refrigerant in the evaporator of the second stage. The effect of operating variables such as evaporator temperature, condenser and absorber temperature, and generator temperature on the coefficient of performance and temperature lift have been studied for two-stage binary absorption heat pump systems. It is found that this cycle has a large temperature lift at $105^{\circ}C$ of optimum generator temperature to obtain $50^{\circ}C$ of condenser temperature.

  • PDF

An Analysis on Direct-Contact Condensation in Horizontal Cocurrent Stratified How of Steam and Cold Water (동방향 성층이상유동에서의 직접접촉 응축현상에 대한 해석)

  • Lee, Sukho;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.130-140
    • /
    • 1992
  • The physical benchmark problem on the direct-contact condensation under the horizontal occurrent stratified flow was analyzed using the RELAP5/MOD2 and /MOD3 one-dimensional model. Analysis was peformed for the Northwestern experiments, which involved condensing steam/water flow in a rectangular channel. The study showed that the RELAP5 interfacial heat transfer model, under the horizontal stratified flow regime, predicted the condensation rate well though the interfacial heat transfer area was underpredicted. However, some discrepancies in water layer thickness and local heat transfer coefficient with experimental results were found especially when there is a wavy interface, and those were satisfied only within the range.

  • PDF

Critical Heat Flux and Working Fluid Quantity in Thermosiphon Heat Pipe (써모싸이폰 히트파이프에서 열수송한계와 최적작동유체 주입량에 관한 연구)

  • 이기우
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.10a
    • /
    • pp.193-208
    • /
    • 1998
  • 본 논문에서는 써모싸이폰식 히트파이프의 열수송한계와 작동유체의 주입량이 파이프의 직경, 가열량 및 증발부와 응축부의 길이비 등에 따라 변화하므로 이러한 인자에 따른 적정 작동유체의 주입량과 가열량의 한계에 대해 고찰하였다. 특히 각종 전자부품의 냉각에 사용되는 히트파이프가 써모사이폰식이므로 사용작동유체에 대해 가열량에 따라 파이프의 직경예측이 가능토록 열수송한계특성에 대해 검토하고, 싸이리스터용은 증발부와 응축부의 길이비 변동이 심하므로 작동유체의 주입량이 중요한 성능인자로 작용하므로 길이비에 따른 작동유체의 주입량범위에 대해 기술하였다. 그리고 최적의 작동유체범위와 히트파이프의 증발열전달계수 및 응축열전달계수에 대한 실험으로부터 성능자료를 도출하여 이론해석과 비교검토하였다.

  • PDF

The Heat Transfer Characteristics of Rotating Heat Pipe with Tapered Condensers in the both Sides of Evaporator (증발부 양단에 테이퍼 응축기를 가진 회전형 히트파이프의 전열 특성)

  • 이기우;이영수;장기창;장영석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.13-25
    • /
    • 1996
  • The purpose of this paper is to study heat transfer characteristics of rotating heat pipe with tapered condensers by numerical analysis and experimental method. An experimental investigation has been carried out on thermal resistance between condenser wall and vapor region fo the rotating heat pipe with various taper 0, 1/11.4, 1/38. Heat transfer characteristics by analytical study were applied to describe various Nu numbers on the base of dimensionless condensate film, Re and Pr numbers in both condensers. Comparison between calculated results and experimental data showed qualitatively good agreement and the numerical analysis of this study can be utilized to predict the performance of a rotating heat pipe. The thermal resistance can be decreased by increasing the revolution per minute. Regardless of various dimensionless condensate film, Nu number was largely influenced by saturation temperatures of working fluid.

  • PDF

An Analytical Study on the Condensation of Submerged Vapor Jets in Subcooled Liquids (과냉수에서의 증기응축제트에 대한 해석적 연구)

  • 김기웅;이계복;김환열
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.333-340
    • /
    • 1999
  • A numerical study of turbulent condensing vapor jet submerged in subcooled liquids has been conducted. A physical model of the process is presented employing the locally homogeneous flow approximation of two phase flow in conjunction with a $\kappa$-$\varepsilon$-g model of turbulence properties. In this model the turbulence is represented by differential equations for its kinetic energy and dissipation. A differential equation for the concentration fluctuations is solved and a clipped normal probability distribution function is proposed for the mixture fraction. Effects of steam mass flux, pool temperature and nozzle internal diameter on the condensing vapor jet are also analyzed. The model is evaluated using existing data for turbulent condensing vapor jets. The agreement between the predictions and the available experimental data is good.

  • PDF