Coagulation Characteristics of Wastewater Treatment Process Using Completely Mixed Chamber (완전 혼화조를 이용한 폐수처리 공정의 응집특성)

  • Kim, Dong-Jun;Park, Sang-Kyoo;Lee, Yong-Ho;Yang, Hei-Cheon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1187-1195
    • /
    • 2009
  • The objective of this study is to investigate the coagulation characteristics of the completely mixed chamber for wastewater treatment. The completely mixed chamber system was composed of the reservoirs, the three-stage mixing and coagulation part with propeller impeller, the injection parts of coagulants, a sedimentation tank and a control panel. Wastewater sample of pH 8.5 and initial turbidity 1,000NTU was prepared using sludge taken from a tunneling work site. The efficiency of turbidity removal with increasing the dosage of coagulant aids increased by about 99%. Increasing coagulant above the optimal dosage, however, the efficiency of turbidity removal decreased.

The Effects of Mixer Geometry on Hydraulic Turbulence : Computational Modeling (3-D 전산유체를 이용한 급속혼화조 형상에 따른 난류 유동장 연구)

  • Park, No-Suk;Kim, Sung-Hoon;Park, Heekyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1173-1182
    • /
    • 2000
  • The rapid mixing process has been considered as an important step in water treatment. Since the coagulant dispersion into raw water by rapid mixer can influence on the flocculation and filtration efficiency, many researchers have developed various devices and mixing methodologies. Until now, they focused attention on only coagulant dose, pH. rotating velocity and G value but overlooked the real turbulent flow and mixer geometry in rapid mixer. Therefore this paper questions the significance of turbulent flows in rapid mixer and focuses on the analysis of turbulent fluid in various mixer geometry with CFD(Computational Fluid Dynamics). The results of the jar-tests using various geometries indicate that the turbidity removal rate in a circular jar without baffle is higher than that of a circular with baffle. And the turbidity removal rate in Hudson jar is also founded to be higher than in the circular jar with baffle. The CFD simulation of velocity fields in jar demonstrates that the differences of removal rates among the various geometries are largely due to the formation of the different turbulent fluids fields with different geometries.

  • PDF

Enhancement of Coagulation and Flocculation Efficiencies by Ultrasonic Chemical Spray Nozzle I (초음파 약품분사노즐을 이용한 응집효율 향상 I)

  • Kim, Jin-Kook;Cho, Soon-Haing;Ha, Dong-Yun;Koh, Jae-Seok;Kim, Yong-Hyun;Choi, Seung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.52-58
    • /
    • 2005
  • To establish low-cost and high efficiency water treatment process, feasibility of applying ultrasonic spray nozzle for chemical injection was evaluated. Ultrasonic spray nozzle was manufactured using piezoelectric ceramics. Treatment efficiencies of contaminants by ultrasonic spray nozzle were compared with conventional chemical mixing such as back-mixing. It was found out that the rate of chemical diffusion rate by ultrasonic spray nozzle was faster than by back-mixing method. Removal efficiencies of various contaminants, such as turbidity, organics and microorganism by ultrasonic spray nozzle were also higher than by back-mixing method. By adapting ultrasonic spray nozzle in coagulant injection process, it can be prevented that the decline of treatment efficiency by coagulant overdose. The amount of coagulant can be reduced by applying ultrasonic spray nozzle in water treatment. Along with these advantages chemical mixing chamber is not required if ultrasonic spray nozzle is adapted. From these results, it can be concluded that chemical injection by ultrasonic spray nozzle is an economical and highly efficient device for coagulant mixing.

Determination of Optimal Coagulation Condition for Coagulation-UF Water Treatment Process (응집-UF 정수공정을 위한 칠적응집조건의 결정)

  • Lee, Chul-Woo;An, Su-Kyong;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.799-806
    • /
    • 2005
  • Applying coagulation process before membrane filtration showed not only reducing membrane fouling, but also improving the removal of dissolved organic materials that might otherwise not be removed by the membrane alone. Also, slow mixing didn't affect the reduction of membrane fouling, and rapid mixing using an in-line static mixer was more effective than using backmixer. In addition, only 11 percent of dissolved organic matter in raw water was the primary cause of fouling. Furthermore, tile primary foulant of UF membrane was hydrophobic substance, which can easily be removed by coagulation.

Effect of Coagulated Flocs Broken by the Pressure Pump on Removal Rate and Membrane Fouling of Pressurized MF process (가압펌프에 의해 해체된 플럭이 가압식 막여과 공정의 제거효율 및 막오염에 미치는 영향)

  • Kim, Junhyun;Moon, Baeksu;Park, Jongsu;Cho, Yoonho;Kim, Jinho
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.460-468
    • /
    • 2013
  • This study reviewed optimum dosage rate of coagulant and ability to remove dissolved organic carbon without sedimentation in conventional water purification plant. It was confirmed that floc formated by pre-treatment process was broken by impeller of booster pump. Optimum dosage rate of coagulant was 4 mg/L (as PACl 17%) for floc formation through blend, coagulation and after passing through the pump when turbidity of raw water was less than 10 NTU. And average removal rate of dissolved organic carbon was 43% at that time. Maximum removal rate of dissolved organic carbon was 48%, even though coagulation rate was increased gradually until 8 mg/L (as PACl 17%). So removal rate of dissolved organic carbon is not much improved even if dosage rage of coagulant increase. TMP of PVDF (polyvinylidene flouride) pressurized MF process without pre-treatment operated at 0.54 bar and TMP of PVDF pressurized MF process with pre-treatment operated at 0.41 bar.

The Evaluation of Fouling Mechanism on Cross Flow Precoagulation-UF Process (십자형 응집-UF 막분리 공정 적용시 전처리 응집조건에 따른 막오염 메카니즘 규명)

  • Jung, Chul-Woo;Son, Hee-Jong
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.639-645
    • /
    • 2008
  • The objectives of this research are to (1) observe changes in particle size distribution due to formation of microflocs during coagulation process (2) identify the membrane fouling potential on cross flow system (3) investigate the mechanism of membrane fouling. The rate of flux decline for the hydrophobic membrane was significantly greater than for the hydrophilic membrane, regardless of pretreatment conditions. The pretreatment of the raw water significantly reduced the fouling of the UF membrane. Also, the rate of flux decline for the hydrophobic membrane was considerably greater than for the hydrophilic membrane. Applying coagulation process before membrane filtration showed not only reducing membrane fouling, but also improving the removal of dissolved organic materials that might otherwise not be removed by the membrane. That is, during the mixing period, substantial changes in particle size distribution occurred under rapid and slow mixing condition due to the simultaneous formation of microflocs and NOM precipitates. Therefore, combined pretreatment using coagulation not only improved dissolved organics removal efficiency but also flux recovery efficiency.

Treatment of Contaminated Groundwater Containing Petroleum and Suspended Solids Using DAF and Mixed Coagulation Processes (DAF와 혼화응집공정을 이용한 현탁성 고형물 함유 유류 오염 지하수 처리)

  • Lee, Chaeyoung;Jang, Yeongsu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.8
    • /
    • pp.25-32
    • /
    • 2010
  • Contamination of soil and groundwater by the compounds of hydrocarbon petroleum has been widely accepted as the main cause that harms the environments and health. To remove those pollutants, absorbing clothes, activated carbons, or oil-water separation devices with the gravity method are employed for treatment. However, those materials and devices cannot remove the emulsion pollutants despite of their efficiency for removing free products. Therefore, we investigated the problems which occur during the groundwater treatment for the highly concentrated suspended solid particles, which can be resulted from excavation, and to propose methods to remove TPH(Total Petroleum Hydrocarbon). After coagulation experiment with high molecular polymers, the concentration of SS(Suspended Solids) and COD(Chemical Oxygen Demand) turned to satisfy the groundwater quality criteria within 5 minutes while the concentration of TPH failed to meet the water quality standard of effluent. Consequently, the water quality criteria for effluent could not be met by single DAF(Dissolved Air Flotation) process. However all water quality criteria could be satisfied after 20 minutes when coagulation reactions are carried out simultaneously in the DAF reactor.

The Removal Characteristics of Organic Matter in Drinking Water Source by Coagulation and Ultrafiltration Process (응집 및 한외여과 공정에 의한 상수원수의 유기물질 제거 특성)

  • Kim, Hyun-Sik;Lim, Ji-Young;Kim, Jin-Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.2
    • /
    • pp.5-10
    • /
    • 2018
  • This study was evaluated the characteristics of organic materials in the water source and the removal characteristics of organic materials by ultrafiltration including mixing and coagulation process. As a results of the study, it was found that the total organic carbon in the water source was mostly caused by the dissolved organic materials. As the specific ultraviolet absorbance value of the raw water was low, we found the soluble organic material has a high hydrophilic and low molecular material composition ratio. As a result of ultrafiltration experiment including mixing and coagulation process, the average removal rate of total organic carbon, dissolved organic carbon and ultraviolet absorbance at 254 were 37.9%, 30.3%, and 28.2%, respectively.

Utilization of response surface methodology to optimize a coagulation-flocculation process for tunnel wastewater treatment (반응표면분석법을 이용한 터널폐수 응집-혼화 공정의 주요인자 영향 분석 및 최적화)

  • Jeong, Se-Uk;Lee, Jae-Hyun;Park, Tae-Won;Kim, Young Mo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.601-608
    • /
    • 2014
  • A coagulation-flocculation (CF) process using aluminum sulfate as a coagulant was employed to treat highly suspended solids in tunnel wastewater. Response surface methodology (RSM) based on a Box-Behnken design was applied to evaluate the effects of three factors (coagulant dosage, pH and temperature) on total suspended solids (TSS) removal efficiency as well as to identify optimal values of those factors to maximize removal of TSS. Optimal conditions of coagulant dosage and pH for maximum TSS removal changed depending on the temperature ($4{\sim}24^{\circ}C$). As temperature increased, the amount of coagulant dosage and pH level decreased for maximum TSS removal efficiency during the CF process. Proper adjustment of optimal pH and coagulant dosage to accommodate temperature fluctuations can improve TSS removal performance of the CF process.

Development of the hi-speed composite cohesive device for reduction of particulate pollutants in storm water runoff (초기강우 유출수의 입자성 오염물질 처리를 위한 고속복합응집장치 개발)

  • Choi, Sunhwa;Lee, Jinkyung;Lee, Seungheon;Kim, Heungseop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.197-197
    • /
    • 2017
  • 본 연구에서는 입자성 오염물질을 다량 함유하고 있는 초기강우 유출수를 처리하기 위한 수처리 시설로 고속복합응집장치를 개발하였다. 고속응집복합장치의 요소기술은 마이크로 버블, 급속교반장치(인라인믹서), 전기촉매를 이용한 부상촉진장치, 볼텍스 흐름 등으로 구성되며, 기술 원리는 응집제에 의해 오염물질을 응결, 응집, 부상시켜 스컴을 제거하는 일반 응집 원리와 유사하다. 본 기술의 특징은 교반, 혼화조, 응집제를 1개의 조에 컴팩트하게 구성하여 체류시간을 10분 이내로 단축하였고, 볼텍스(voltex) 흐름을 이용한 선회류와 루버홀 형태의 스크린을 적용하여 응집효과를 극대화하였으며, 플럭에 의한 막힘이 없이 스크리닝이 이루어질 수 있도록 하였다. 또한, 부상촉진장치(전기유도)를 이용해 응집 플럭의 부상효과를 상승시켰고, 감속기와 일체화된 내통스크린이 선회류와 반대 방향으로 회전하면서 볼텍스 흐름의 가속효과에 의한 스크린 폐색 방지 및 응집부상 효율을 향상시킬 수 있도록 설계하였다. 부상슬러지는 별도의 플럭 제거 설비 없이 스크린 내통 회전에 이용되는 감속기에 부착된 스컴 제거기에 의해 동시 제거가 가능하며, 응집부상 처리수는 장치 가장 바깥 외곽에 충진된 필터층에서 최종 여과되어 방류되도록 구성함으로서 모든 처리공정이 단일 장치 내에서 이루어지도록 구성하였다. 본 고속복합응집장치는 전체 규격 ¢ $1000{\times}2,000mmH$의 시제품이 제작되어 현재 시흥소재 매화저수지에서 성능평가를 실시하고 있다.