• Title/Summary/Keyword: 응집가압부상

Search Result 12, Processing Time 0.028 seconds

Livestock Wastewater Treatment Using MBR/NF/RO and Application of Post-Denitrification and Air Flotation Process to Treat Excess Sludge and NF/RO Brine (MBR/NF/RO를 이용한 가축폐수처리와 후탈질/응집가압부상을 이용한 잉여슬러지 및 농축수 처리 기술)

  • Na, Yumee;Bae, Jongbok;Moon, Taehun;Hwang, Yunyoung;Lee, Yangwoo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.6
    • /
    • pp.407-414
    • /
    • 2013
  • Full scale livestock wastewater treatment plant (100 t/d) was constructed and operated to develop compact and cost effective treatment process for public plant as well as individual farm. Liquid form of livestock wastewater after belt press filter was treated through MBR/NF/RO. NF/RO brine water was mixed with livestock wastewater sludge and treated using denitrification, coagulation and air flotation process. Mixed effluent of NF/RO and air flotation meet public livestock wastewater treatment standard, BOD, T-N and T-P, 30 mg/L, 60 mg/L, 8 mg/L below, respectively. Condensed sludge of air flotation returned belt press filter. Dewatered cake contained 90% water and could be used fertilizer after mixing sawdust.

Application of Dissolved Air Flotation Technique to Improve Reservoir Water Quality (가압부상 공법을 이용한 호소수질개선 연구)

  • Kim, Tae-Hoon;Sei, Young-Ho;Ahn, Tae-Woong;Choi, I-Song;Oh, Jong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.491-493
    • /
    • 2012
  • 우리나라는 농업용수, 생활용수 등의 목적으로 여러 개의 호소 등을 설치하여 운영 중에 있다. 하지만 몇몇 호소들은 인구증가 및 산업발달로 인하여 매년 오염도가 증가하는 것으로 알려져 있으며, 특히 부영양화 현상으로 인하여 남조류가 과다번식 할 경우 호소 수질 및 수생태계에 악영향은 미치는 것으로 알려져 있다. 따라서 호소의 부영양화 현상을 제어하기 위한 많은 연구가 이루어지고 있으며, 부영양화 현상을 발생시킬 수 있는 여러 제한인자 중 인(P)에 대한 관심이 많아지고 있는 실정이다. 부상분리의 일종인 DAF는 침전공정의 대안으로서 25년 전부터 유럽과 미국을 중심으로 정수 및 하수처리 공정에서 이용되어 왔다. 가압부상공법에서 발생되는 기포의 크기는 $50{\sim}100{\mu}m$ 정도로 부상물질인 스컴이 파괴될 가능성이 낮고 기포의 크기가 작아 공기의 용해효율이 높으며 대전작용, 물리적 흡착효과 등의 특징을 가진다고 알려져 있다. 또한 공기와 물 뿐만 아니라 Al 성분의 응집제인 PAC를 이용하여 버블을 발생시킬 경우 인의 제거 효율이 크다고 알려져 있다. 가압부상공법의 경우 응집 침전 공정과는 달리 발생되는 처리과정에서 발생되는 부산물을 외부로 유출 시킬 수 있기 때문에 호소 수질정화에 이용될 수 있다고 판단된다. 따라서 본 연구에서는 저수지의 형태와 유사한 반응조를 설계하여 DAF를 주입하는 실내실험을 진행하였으며, 이를 통해 호소수질 정화를 위한 DAF의 타당성에 대해 평가하기 위해 이루어졌다.

  • PDF

Thickening of Activated Sludge Using Low Pressure Flotation Pilot System (파일롯 규모의 저압형 부상장치를 이용한 하수슬러지 농축에 관한 연구)

  • Kim, Ji Tae;Oh, Joon Taek;Kim, Jong Kuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.3
    • /
    • pp.172-177
    • /
    • 2014
  • Low pressure air flotation (LAF) pilot plant for sludge thickening was installed in Chung Nam N.S. municipal waste water treatment plant to verify its application possibility. Effects of operating conditions such as coagulant dosages and microbubble water ratio on thickening of the mixed sludge were examined. Microbubbles which were generated in the chamber of $1.5kgf/cm^2$ by high speed collision method with foaming agent were used to float sludge. Solid loading of $30kg/m^2/hr$, solid contents in thickened sludge of 60,300 mg/L and SS removal efficiency of 99% were obtained through long period operating LAF in conditions of mixed sludge concentration of 14,400 mg/L, coagulant dosage of 27.6 mg/L, foaming agent addition of 4.0 mg/L and microbubble water injection ratio of 9.7%.

환경관련 특허동향 - 녹색 건축물에 적용되는 중수도 설치를 위한 수처리 시스템(주식회사 대성그린테크)

  • 한국환경기술인연합회
    • Environmental engineer
    • /
    • s.324
    • /
    • pp.86-93
    • /
    • 2013
  • 본 발명은 녹색 건축물에 적용되는 중수도 설치를 위한 수처리 시스템에 관한 것으로서, 더욱 상세하게는 건축물에서 배출되는 오수의 유입량을 제어하면서, 산기장치를 이용하여 상기 오수에 일정량의 에어를 공급하여 슬러지의 침강과 부패방지를 유도하는 유량조정조와, 상기 유량조정조를 거친 오수를 응집 및 침전처리하고 가압부상에의해 슬러지를 처리하는 가압부상조와, 상기 가압부상조를 거친 오수에 포함되어 있는 질소, 인을 처리하는 무산소조와, 상기 무산소조를 거친 오수에 포함되어 있는 유기물을 수처리용 접촉 메디아(DSBB)에 의해 분해하는 생물막조와, 상기 생물막조를 거친 오수를 침전과정을 통해 침전된 슬러지를 외부로 배출하는 침전조와, 상기 침전조를 거친 오수를 분리막에 통과시켜 오수에 포함되어 있는 미생물, 세균등의 미세입자들을 제거하는 분리막조와, 상기 분리막조를 거친 오수에 포함되어 있는 미처리 미세입자를 여과기에 통과시켜 처리하는 여과조와, 상기 여과조를 거친 오수를 오존($O_3$) 또는 UV 살균 처리하는 소독조와, 상기 소독조를 거쳐 최종적으로 처리된 처리수를 일정시간 동안 체류시켰다가 건축물의 중수로 재이용하기 위해 방출시키는 저수조를 포함하여 이루어지는 녹색 건축물에 적용되는 중수도 설치를 위한 수처리 시스템에 관한 것이다.

  • PDF

A Study on the Shape and Movement in Dissolved Air Flotation for the Algae Removal (수중조류제거(水中藻類除去)를 위한 가압부상(加壓浮上)에 있어서 기포(氣泡)의 양태(模態)에 관한 연구(研究))

  • Kim, Hwan Gi;Jeong, Tae Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.79-93
    • /
    • 1984
  • The dissolved air flotation(DAF) has been shown to be efficient process for the removal of algae ftom water. The efficiency of DAF can be affected by the volume ratio of pressurized liquid to sample, the pressure pressurized liquid, the contact time, the appropriate coagulant and its amount, the water temperature, the turbulence of reactor, the bubble size and rising velocity etc. The purpose of this paper is to compare the practical bubble rising velocity with the theoretical one, to investigate the adhesion phenomenon of bubbles and floc, and the influence of bubble size and velocity upon the process. The results through theoretical review and experimental investigation are as follows: Ives' equation is more suitable than Stokes' equation in computation of the bubble rising velocity. The collection of bubble and algae floc is convective collection type and resulted from absorption than adhesion or collision. The treatment efficiency is excellent when the bubble sizes are smaller than $l00{\mu}m$, and the turbulence of reactor is small. In the optimum condition of continuous type DAF the volume ratio of pressurized liquid to sample is 15%, the contact time in reactor is 15 minutes, the pressure of pressurized liquid is $4kg/cm^2$ and the distance from jet needle to inlet is 30cm.

  • PDF

Application of Ti-salt Coagulant and Sludge Recycling for Phosphorus Removal in Biologically Treated Sewage Effluent (하수종말처리장의 인 처리시설에 티탄염 응집제 적용 및 슬러지 재활용)

  • Kim, Jong Beom;Park, Hee-Ju;Lee, Ki Won;Jo, A Ra;Kim, Myung Wan;Lee, Young Jun;Park, Se Min;Lee, Kwang Young;Shon, Ho Kyong;Kim, Jong-Ho
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.257-262
    • /
    • 2013
  • As the regulation of total phosphorus (T-P) concentration in biologically treated sewage effluent is reduced to 0.2~2 mg/L, flocculation process is recommended to remove T-P. In this study, the performance of Ti-salt coagulant was investigated in terms of dosage and pH in removing phosphorus and the collected sludge after Ti-salt flocculation was calcined to produce titania for effective sludge recycling. The flocculation performance was carried out using two methods: sedimentation and air floatation. Both methods were feasible to apply for Ti-salt flocculation. Ti-salt flocculation was effective in reducing phosphorus concentration in sewage effluent, which showed similar performance of alum ($Al_2(SO_4)_3$). The calcined sludge was recycled to titania which is the widely used metal oxide. Titania produed from Ti-salt sludge indicated similar characteristics of commercially-available P-25 in regard to photocatalytic activity and surface area. Therefore, this can be easily adopted to titania application by replacing P-25.

Application of Dissolved Air Flotation Technique to Improve Eutrophic Reservoir Water Quality (가압부상법을 이용한 부영양저수지의 수질개선)

  • Kim, Ho-Sub;Jung, Dong-Il;Lee, Il-Kuk;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.372-381
    • /
    • 2005
  • This study was conducted to test the efficiency of water quality improvement using the dissolved air flotation (DAF) technique in a shallow eutrophic reservoir. The application of DAF was followed by the addition of a chemical coagulant (poly aluminum chloride; PAC). The experiment was conducted in the mesocosm scale (wide ${\times}$ length ${\times}$ depth: 6 m ${\times}$ 6 m ${\times}$ 3 m). Suspended solids (SS) and volatile SS (VSS) concentration decreased by 54 ${\sim}$ 71% and 57 ${\sim}$ 79% of the initial concentrations, respectively. Total phosphorus and Chl- a concentration also decreased by 74 ${\sim}$ 92% and 54 ${\sim}$ 98%, respectively. BOD decreased by>86% while COD decrease ranged 29 ${\sim}$ 63%. Dissolved inorganic P (DIP) and dissolved total P (DTP) concentration decreased by 34 ${\sim}$ 88% and 62 ${\sim}$ 88%, respectively. After DAF application further onto the sediment, DIP-release rates from the sediment decreased by 17% (0.82 ${\to}$ 0.68 mg $m^{-2}$$day^{-1}$ in the oxic condition and 23% (2.27 ${\to}$ 1.76 mg $m^{-2}$$day^{-1}$) in the anoxic condition, compared to the release rate from the untreated sediment. DTP-release rate from both the oxic and anoxic sediments also decreased by 33% (5.62 ${\to}$ 3.78 mg $m^{-2}$$day^{-1}$) and 20% (6.23 ${\to}$ 4.99 mg $m^{-2}$$day^{-1}$), respectively. These results suggest that the DAF application both to the water column and onto the sediment be effective to improve water quality by removing particulate matters in the water column as well as reducing P-release from the sediment.

A Practical Study on the Solid-Liquid Separation of the Swine Wastewater from Slurry Feedlot (슬러리 양돈분뇨의 최적 고액분리 방안 연구)

  • Park, Seung-Kyun;Choi, Jae-Gil;Chung, Yoon-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.60-70
    • /
    • 2000
  • The swine wastewater from slurry feedlot has been a social problem in Korea since the proper treatment is very difficult. Therefore, a practical study on the Solid-Liquid separation of swine wastewater from slurry feedlot was carried out as a pan of pretreatment for the successful biological treatment. The appropriate type of coagulant and optimum dosage were proposed for the most efficient Solid-Liquid separation and the best Solid-Liquid separation methods for different size of feedlot were determined through the tests with field-scaled Solid-Liquid separation equipment. The appropriate coagulant for the conditioning of dewatering property was E-851, which is a cationic polyelectrolyte made of polyacrylamide, and the optimum dosage was 0.24~0.6% of unit solids weight. Mesh Screen, Drum Screen, Cyclone Drum Filter, Screw Press, High-speed Screw Decanter, Low-speed Screw Decanter, and Dissolved Air Flotation Process had been investigated in this study. According to the results, the Screw Press was the best dewatering equipment for the small & medium size for feedlot and low-speed Screw Decanter was the best for the large size feedlot & public owned treatment facilities for the primary Solid-Liquid separation, and the most suitable secondary treatment process was DAF. On the other hand, reductions for the requirement of bulking agent and organic loading by Solid-Liquid separation process were 94.8% and 84.7%, respectively Therefore, the Solid-Liquid separation process must be required for the successful treatment of swine wastewater from slurry feedlot.

  • PDF

The Effects of Residual Al on Plankton Community after Dissolved Air Flotation (DAF) Application (가압부상 후 잔류 응집제가 플랑크톤 군집에 미치는 영향)

  • Kim, Ho-Sub;Gong, Dong-Su;Lee, Hyung-Jin;Shin, Jong-Kyu;Kang, Tae-Gu
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.837-842
    • /
    • 2007
  • This study was conducted to test the effect of residual Al on plankton community after dissolved air flotation (DAF) application. Growth rate of phytoplankton after DAF application ($0.37day^{-1}$) was about 2 times lower than that before DAF application ($0.70day^{-1}$). Under the condition of addition of nitrogen and phosphorus without light, growth rate phytoplankton in treatment without residual Al increased in difference with showing the negative growth rate in treatment with residual Al. Under the condition of light without addition of nutrient, growth rate of phytoplankton was no noticeable difference between the before and after DAF application. The relatively high settling rate (0.47 m/day) was observed in treatment after DAF application. Although the abundance of rotifer decreased, the abundance of copepod and cladoceran such as Daphnia galeata, Diaphanosoma sp. and Bosmina longirostris with relative higher grazing was no noticeable difference between the before and after DAF application. In the treatments before and after DAF application with zooplankton, growth rate of phytoplankton was $0.41{\pm}0.08day^{-1}$, $0.20{\pm}0.03day^{-1}$, respectively. This difference was in treatment after DAF application similar with those in treatments before and after DAF application without zooplankton. Those indicate that the filter-feeding effect of zooplankton on phytoplankton community may be not changed by residual Al after the DAF application. These results suggest that residual Al after DAF application be to improve water quality by inhibition of growth rate as well as increasing settling rate of phytoplankton.

The Practical Study for the Treatment of Fish Processing Saline Wastewater Using Immersed MBR (iMBR 공정을 이용한 수산물가공폐수 처리에 관한 실증적 고찰)

  • Park, Seung Kyun;Lee, Dong Jun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.469-475
    • /
    • 2016
  • The study is the result of an practical operation analysis for the full scale fishery product wastewater treatment plant with immersed MBR (iMBR) process. Since fishery product industries show a wide range of wastewater generation by the season, design and operation of the equalization basin are very important factor. The aeration system for the equalization basin mixing can save the chemical consumption for followed system through the restriction of acid fermentation. The concentrations of wastewater primary DAF process treated were BOD 2,291 mg/L, $COD_{Mn}$ 530 mg/L, SS 256.8 mg/L, T-N 38 mg/L, T-P 13.5 mg/L respectively. It was considered that iMBR is the most efficient biological process for high salinity content wastewater since It is irrelevant to the capability of the sludge precipitation. SADp and SADm were 0.31, $26.5m^3/hr{\cdot}m^3$ respectively. In iMBR process, the critical F/M ratio was derived at 0.08~0.10 gBOD/gMLSS by analysing the correlations between MLSS, normalized TMP and temperature. The effluent concentrations were BOD 1.8 mg/L, $COD_{Mn}$ 12.4 mg/L, SS 1.0 mg/L, T-N 7.85 mg/L, T-P 0.1 mg/L and removal efficiencies were 99.9%, 97.6%, 96.3%, 95.7%, 97.8% respectively.