• Title/Summary/Keyword: 응답변화

Search Result 1,931, Processing Time 0.026 seconds

The Outlet Temperature Prediction of In-Situ Thermal Response Test using CFD Analysis (CFD 해석을 이용한 현장 열응답 시험의 출구온도 예측)

  • Sim, Yong-Sub;Lee, Hee-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.28-35
    • /
    • 2016
  • The in-situ thermal response test for the design of a ground heat exchanger of geothermal heat pumps have difficulty in predicting the outlet temperature according to the variation of conditions due to the expense and time. This paper suggests a 3-D CFD analysis method to predict the heat transfer performance of vertical type ground heat exchanger, which is mostly used in national, and the outlet temperature and the slope of two in-situ thermal response tests were compared to test the proposed CFD reliability. The results of CFD analysis showed that the outlet temperature was predicted to within $0.5^{\circ}C$ of the actual value and the slope was predicted to within 1.6%. The reliability of the CFD analysis method was confirmed using this process, and the outlet temperature prediction of the two in-situ thermal response tests was obtained by changing ${\pm}20%$ of the flow rate and the effective thermal conductivity conditions, respectively. The results of CFD analysis showed that the outlet temperature of Case 1 was 28.0 (-20%) and $29.6^{\circ}C$ (+20%) for the flow rate variation and $29.6^{\circ}C$ (-20%) and $28.0^{\circ}C$ (+20%) for the effective thermal conductivity variation, and the outlet temperature of Case 2 was 28.4 (-20%) and $29.8^{\circ}C$ (+20%) for the flow rate variation and $29.7^{\circ}C$(-20%) and $28.4^{\circ}C$(+20%) for the effective thermal conductivity variation.

A Study on Response Characteristics of ionization Smoke Detector Influenced by Air Stream (이온화식 연기감지기의 기류응답특성 연구)

  • 이복영;정길순;이병곤
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.6-9
    • /
    • 2003
  • Recently, forced ventilating air conditioning system has been widely used in modern buildings. However, It is obvious that this kind of system may affect on the response of fire detectors at real fire incidents, especially, on the ionization smoke detector, which is critically influenced by air stream. Therefore we studied to verify the response characteristics of air stream by ionization smoke detector for the design of facilities in practice. In this study, experiments were executed to examine the correlation between air velocity and the ionization detector's responses with var-ious air velocity and smoke densities in the simulated test room. As a result of experiments, ionization detector's operating time is in reverse proportion to air velocity. And the detector shows more sensitive reaction when the velocity of smoke stream increase over 60 cm/s. In addition, it was shown that ionization smoke detector is more sensitive to smoldering fires in paper than that in petro-chemicals.

Understanding for Classical Control System by Analysis of Program-based Time Response (프로그램 기반의 시간응답 해석에 의한 고전제어 시스템 이해)

  • Min, Yong-Ki;Wi, Young-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.9
    • /
    • pp.893-900
    • /
    • 2016
  • Output response for prototype system is analyzed according to the pole locations and the damping ratio changes. The system modeling is constructed for RLC-circuit and the output response is analyzed for both a unit-step and a sinusoidal input. The survey is conducted to estimate the understanding ability on the automatic control. A high understanding ability is shown up in analysing the transfer functions of control system. And improvement is manifest in the ability to understand the output response according to the parameter changes. But some difficulty is revealed in acquiring the output responses in time domain.

단층파쇄대를 통과하는 경안대교의 부지효과를 고려한 지진응답해석

  • 조의경;이장석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.646-655
    • /
    • 2002
  • 장대 교량이 위치한 지반에서 지진에 의한 지반 운동은 교량의 길이 방향으로 공간적인 변화를 일으킨다. 지형 변화나 지반 매질의 물성 변화가 있는 비균질한 지반에서 지반 운동의 진폭과 주파수 성분은 변화하고 이 부지 효과(site effect)는 교량의 지진 응답에 지배적인 영향을 미치며 그 영향은 파전파 효과(wave passage effect)에 의한 지반 각 지점의 지진파 도달시간 차이나 비균질성이 큰 지반에서 파의 다중 반사, 굴절에 의한 영향보다 크다[1]. (중략)

  • PDF

Investigation of Impact Factor and Response Factor of Simply Supported Bridges due to Eccentric Moving Loads (이동하중의 편측재하에 따른 단순교의 충격계수 및 응답계수 변화 분석)

  • Hong, Sanghyun;Roh, Hwasung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.105-113
    • /
    • 2018
  • The proposed model to predict the bridge load carrying capacity uses the impact response spectrum. The spectrum is based on Euler-Bernoulli beam and the center of the bridge width for the moving load location. Therefore, it is necessary to investigate the eccentric moving load effects on the impact factor and response factor. For this, this study considers 10 m width and two-lane simply supported slab bridges and performs the moving load analysis to investigate the variations of peak impact factor and corresponding response factor. The numerical results show that the eccentric load increases both the static and dynamic displacements, but the impact factor is decreased since the incremental amount of static displacement is bigger than that of dynamic displacement. However, the difference of the impact factors between the center and eccentric loadings is small showing less than 0.5%p. In the response factor, the eccentric loading increases both the static and dynamic response factors, compared to the center loading. The difference of the response factor is only 0.18%p. It shows that the eccentric loading has very small effects on the response factor, thus the impact factor response spectrum which is generated based on the center moving load can be used to determine the response factor.

화련 대형내진모델시험 구조물의 지진응답해석

  • 현창헌;이성규;윤철호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.471-476
    • /
    • 1997
  • 본 논문에서는 국제공동연구로 수행중인 화련 대형내진모델시험 사업에서 계측지진기록을 이용한 모델구조물의 지진응답해석을 수행한 결과를 기술하였다. 지진응답해석은 3차원 유연체적 부구조법을 사용하는 지반-구조물 상호작용해석 전용 전산프로그램인 SASSI를 이용하여 수행하였으며, 지반 특성은 지반조사 결과 제시된 두 가지 지반모델과 계측지진 지반운동으로부터 직접 유도해 낸 지반모델의 지반 특성값을 사용하였다. 또한 본 연구에서는 지반과 구조물 특성값의 변화에 대한 구조물 지진응답의 민감도 및 지반의 비선형 특성이 구조물의 응답에 미치는 영향을 분석하였다.

  • PDF

지반특성에 따른 면진 및 비면진구조물의 가속도응답 영향평가

  • Yoo, Bong;Lee, Jae-Han;Koo, Kyung-Hoe
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.392-397
    • /
    • 1996
  • 지반특성에 따라 지진발생시 면진구조물과 비면진 구조물의 응답특성이 어떠한가를 평가하기위해, 1940 El Centro 지진을 입력지진으로 하고, 면진구조물로는 가압경수형 원자로격납건물을 이용하여 수평(NS) 및 수직지진입력에 대한 시간이력해석을 수행하였다. 0.5Hz 수평면진 구조물의 경우 수평방향 가속도응답은 지반특성에 무관하게 거의 변화가 없으며, 또 2Hz 이상에서 비면진구조물의 수평지진가속도응답보다 현저히 낮은 가속도응답을 갖는다. 면진베어링의 수직방향 21Hz 고유진동수는 풍화암의 경우 수직방향 가속도응답에 영향을 주지 않으나. 경암의 경우 원자로지지점에서의 수직방향 가속도응답을 전반적으로 증가시킨다. 비면진 구조물의 경우 지반의 강성이 약할수록 가속도응답이 비교적 큰 폴라크레인위치에서 수평 및 수직방향 가속도응답이 감소되는 것으로 나타났으며, 특히 수직방향의 가속도응답이 크게 감소하는 것으로 나타났다.

  • PDF

A Study on the Compensating System for the Acoustic Characteristics Caused by the Variation of Distance from Sound Source to Microphone (음원과 마이크로폰 사이의 거리변화에 의한 음향 특성 보정에 관한 연구)

  • Jeoung, Byung-Chul;Choe, Yoon-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.197-204
    • /
    • 2012
  • In this thesis, studied the method to minimize the changes in frequency response and level due to the variation of the distance from the source to the microphone. selecting three microphones (omni directional, cardioid, super cardioid) which are being used generally, frequency responses were measured in accordance with the distance changes. Gotten the difference from the reference as the result of measurement, changed responses for each frequency range were compensated in comparison of the original human vocal source. In low frequency range, the low frequency boost caused by the proximity effect and decrease in accordance with the distance were compensated. The variation in mid-frequency range is comparatively small, however since the mid-range is the most important part of the human vocal signal, were compensated the mid-frequency range in comparison of the reference. The human vocal signal variation in high frequency range is extremely small and the high frequency is compensated close to the original source without difficulty. Understanding the microphone characteristics and compensations, this study showed that the response can be maintain among the change of the distance from the source to the microphone.

Study on Response of River Geomorphology due to Human-Induced Disturbance (인위적 교란에 의한 하도지형의 응답에 관한 연구)

  • Kim, Ki-Heung;Jung, Hea-Reyn
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1011-1015
    • /
    • 2010
  • 하천의 이용과 관리적 측면에서 가장 빈번하게 발생하는 하도의 직선화, 홍수량의 변화, 하상굴착, 하폭의 확대 축소 및 횡단구조물 등은 중규모 스케일의 하천지형을 인위적으로 교란시키는 대표적인 사례이다. 따라서, 이러한 인위적 교란은 하천생태계의 기반인 하천의 물리적 구조를 크게 변화시키므로 하도지형의 응답방향을 규명할 필요가 있다. 하천 유역의 지형은 여러 가지 스케일의 지형단위가 조직화되어 있는 것이므로 대(大) 중(中) 소(小)의 3가지 스케일 지형단위로서 계(系, system)를 계층화하고, 작은 계층의 계(系)에서는 큰 계층의 계(系)를 고정적인 경계조건으로 하여, 그 내부의 여러 가지 특징이나 변화를 규정하는 주요 인자를 이용하여 분석해야 한다. 또한 대(大) 스케일은 유역스케일의 지형스케일이며, 하도의 수계망이나 하도종단형 형상 등이다. 중(中) 스케일은 segment에서 reach 스케일의 지형이며 사행형상, 하천 폭 등이다. 소(小)스케일은 수심의 10배 정도이하의 지형스케일이며, 소규모 하상파 등의 미지형(微地形)이다. 따라서, 본 연구에서는 남강과 황강을 대상하천으로 유량 조절과 유사공급이 차단되는 댐하류 및 골재채취와 같은 인위적 교란요인에 의한 중규모(segment scale) 하도지형의 변화와 응답방향을 조사, 분석하였다. 연구결과 유량 및 유사공급량의 변동의 크기에 따라 전체적인 하상저하와 더불어 사주와 소가 소멸되면서 여울과 소가 사라지는 현상이 동조하는 것으로 분석되었으며, 하상의 평탄화에 의하여 저수로의 폭이 넓어져 복열사주가 발달하면서 수심 및 유속의 다양성이 감소되는 것으로 분석되었다.

  • PDF

비정상상태에서의 미생물과 과도응답

  • 조영일;김우식
    • Proceedings of the Korean Society for Applied Microbiology Conference
    • /
    • 1975.07a
    • /
    • pp.110.3-110
    • /
    • 1975
  • 환경인자로써 배양액의 희석속도와 기본기질의 농도를 변화시킨 과도상태에서의 yeast의 대사기능의 면화를 고찰하고 과도응답을 해석하였다. 그 결과 기질의 잔존농도가 충분할때는 응답이 늦었으며 또 희석속도가 클수록 새로운 정상상태에 도달하는 시간이 길었다.

  • PDF